969 resultados para Race Track Volunteer Fire Department


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Report on a special investigation of the City of Corning Volunteer Fire Department for the period July 1, 2013 through April 30, 2015

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this issue...Volunteer Fire Departments, Butte, Montana, Coffee Shop, Glee Club, M Club, Pioneer's Club, Columbia Gardens, Gamer's, Dick Siguaw

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we analyze a novel Micro Opto Electro Mechanical Systems (MOEMS) race track resonator based vibration sensor. In this vibration sensor the straight portion of a race track resonator is located at the foot of the cantilever beam with proof mass. As the beam deflects due to vibration, stress induced refractive change in the waveguide located over the beam lead to the wavelength shift providing the measure of vibration. A wavelength shift of 3.19 pm/g in the range of 280 g for a cantilever beam of 1750μm×450m×20μmhas been obtained. The maximum acceleration (breakdown) for these dimensions is 2900g when a safety factor of 2 is taken into account. Since the wavelength of operation is around 1.55μm hybrid integration of source and detector is possible on the same substrate. Also it is less amenable to noise as wavelength shift provides the sensor signal. This type of sensors can be used for aerospace application and other harsh environments with suitable design.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper discusses noise exposure to firefighters on the job and whether this contributes to noise induced hearing loss.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To examine the effect of fast track on emergency department (ED) length of stay (LOS).

Design and setting: Pair-matched case–control design in a public teaching hospital in metropolitan Melbourne, Australia.

Participants: Patients treated by the ED fast track (cases) between 1 January and 31 March 2007 were compared with patients treated by the usual ED processes (controls) from 1 July to 15 November 2006 (n = 822 matched pairs).

Intervention: ED fast track was established in November 2006 and focused on the management of patients with non-urgent complaints.

Main outcome measures: The primary outcome measure was ED LOS for fast-track patients. Secondary outcomes were waiting times and ED LOS for other ED patients.

Results: Median ED LOS for non-admitted patients was 132 minutes (interquartile range (IQR) 83–205.25) for controls and 116 minutes (IQR 75.5–159.0) for cases (p<0.01). Fast-track patients had a significantly higher incidence of discharge within 2 h (53% vs 44%, p<0.01) and 4 h (92% vs 84%, p<0.01).

Conclusions: ED fast track decreased ED LOS for non-admitted patients without compromising waiting times and ED LOS for other ED patients

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The end magnets of the IFUSP race-track microtron booster, second stage of the electron accelerator under construction at the Linear Accelerator Laboratory, are presented. They deflect, focus and return the beam to the accelerating section. Details about the project are discussed, Poisson code was used to give the final geometry of the end magnets. The end magnets incorporate auxiliary pole pieces (clamps) which create a reverse fringe field region that avoids the beam vertical defocusing and reduces the horizontal displacement produced by extended fringe fields (EFF). The small gap height used for the clamps provided reverse field distributions with fringe fields of short extensions, avoiding the traditional use of inactive clamps. Measurements and calculations concerning particle trajectories and reverse field distribution are presented. The floating wire technique, employing an original procedure to register orbits, was used to corroborate the calculated beam trajectories and represents a good experimental option in the lack of the accelerator beam. The experimental results showed agreement of about 0.1% with the calculations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We will present measurements and calculations related to the antisymmetric perturbations, and comparisons with the symmetric ones, of the IFUSP race-track microtron booster accelerator end magnets. These perturbations were measured in planes situated at +/-12 mm of the middle plane, in a gap height of 4 cm, for a field distribution of about 0.1 T. The measurements were done in 1170 points, separated by a distance of 8 mm, using an automated system with a +/-1.5 mu T differential Hall probe. The race-track microtron booster is the second stage of the 30.0 MeV electron accelerator under construction at the Linear Accelerator Laboratory in which the required uniformity for the magnetic field is of about 10(-3). The method of correction employed to homogenize the IFUSP race-track microtron booster accelerator magnets assures uniformity of 10(-5) in an average field of 0.1 T, over an area of 700 cm(2). This method uses the principle of attaching to the pole pieces correction coils produced by etching techniques, with copper leads shaped like the isofield lines of the normal component of the magnetic field measured. The ideal planes, in which these measurements are done, are calculated and depend on the behavior of the magnetic field perturbations: symmetric or antisymmetric with reference to the middle plane of the magnet gap. These calculations are presented in this work and show that for antisymmetric perturbations there is no ideal plane for the correction of the magnetic field; for the symmetric one, these planes are at +/-60% of the half gap height, from the middle plane. So this method of correction is not feasible for antisymmetric perturbations, as will be shown. Besides, the correction of the symmetric portion of the field distribution does not influence the antisymmetric one, which almost does not change, and corroborates the theoretical predictions. We found antisymmetric perturbations of small intensity only in one of the two end magnets. However, they are not detected at +/- 1 mm of the middle plane and will not damage the electron beam.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Rock Hill Fire Department Records consist correspondence from W.H. Wylie, for whom Lake Wylie is named, to prominent Rock Hillian Mr. W.T. Roddey and to the Rock Hill Fire Department. Also included is a program book for the 33rd Annual Convention of South Carolina State Firemen’s Association held in Rock Hill in 1928. The program book lists officers of the Association, committee appointments, fire chiefs, in SC, Rock Hill city officials with brief biographical sketches and sketches of the history of SC State Firemen’s Association, city of Rock Hill and Winthrop College.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study examined both changing call volume and type with resulting effect of TeleHealth Nurse, the Houston Fire Department's (HFD) telephone nurse line, on call burden during Hurricane Ike. On September 13, 2008, Hurricane Ike made landfall in the Galveston area and continued north through Houston resulting in catastrophic damages in infrastructure and posing a public health threat. The overall goal of this study looked at data from Houston Fire Department to obtain a better understanding of the needs of citizens before, during, and after a hurricane. This study looked at four aspects of emergency response from HFD. The first section looked at call volumes surrounding the time of Hurricane Ike in 2008 compared to the same time period in 2007. The data showed a 12% increase in calls surrounding Hurricane Ike compared to previous years with a p value <.001. Next, the study evaluated the types of calls prevalent during Hurricane Ike compared to the same time period in 2007. The data showed a statistically significant increase in chronic health problems such as diabetes and cardiac events, Obstetric calls and an increase in breathing problems, falls, and lacerations during the days following Hurricane Ike. There was also a statistically significant increase in auto med alerts and check patients surrounding Hurricane Ike's landfall. The third section analyzed the change in call volume sent to HFD's Telephone Nurse Line during Hurricane Ike and compares this to earlier time periods while the fourth and final section looks at the types of calls sent to the nurse line during Hurricane Ike. The data showed limited use of the TeleHealth Nurse line before Hurricane Ike, but when the winds were at their strongest and ambulances were unable to leave the station, the nurse line was the only functioning medical help some people were able to receive. These studies bring a better understanding to the number and types of calls that a city might experience during a natural disaster, such as a hurricane. This study also shows the usefulness of an EMS Telephone Nurse Line during a natural disaster.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cover title: Fire department : city of Flint, 1916.