629 resultados para RPM


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A program for calculating low-speed low-power synchronous machine is presented. A permanent-magnet synchronous generator for 1 kW 150 rpm is designed. Optimization of magnet’s and coil’s dimensions was made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alberta Reig Adrover comenzó a dirigir el Real Colegio de la Pureza de Palma a los pocos meses de morir su marido. Unos años después, forma la primera comunidad religiosa y comienzan a abrirse pequeñas escuelas. Hoy en día los Colegios de la Pureza de María están presentes en Europa, América y África y desarrollan su labor educativa en colegios, escuelas universitarias, obras sociales, misiones y residencias universitarias. El estilo pedagógico de Madre Alberta se caracteriza por la prevención por la que el educador se anticipa para dar orientaciones, la excelencia, la presencia de contacto cordial con los alumnos y la atención individualizada. Los indicadores de esta pedagogía son la unidad de criterios, la creatividad y novedad en los métodos de educación y los métodos didácticos para seguir en la vanguardia; el saber conjugar la educación del corazón y de la inteligencia; la previsión y la organización; y la comunicación continua en un ambiente educativo en el que prima el espíritu de familia. Todo ello a través de unos criterios y recursos metodológicos basados en una motivación constante, un refuerzo positivo, la actividad luchando contra la pasividad, el amor a la naturaleza y la practicidad. Adjunta esquemas y una ficha con los datos y direcciones de la congregación.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The radiopacity of esthetic root canal posts may impair the assessment of their fit to the root canal when using radiographic images. This study determined in vitro the radiographic density of esthetic root canal posts using digital images. Thirty-six roots of human maxillary canines were assigned to six groups (N=6 per group): Reforpost (RP); Aestheti-Plus (AP); Reforpost MIX (RPM); D.T. Light Post (LP); Reforpost Radiopaque (RPR); and White Post DC (WP). Standardized digital images of the posts were obtained in different conditions: outside the root canal, inside the canal before and after cementation using luting material, and with a tissue simulator. Analysis of variance was used to compare the radiopacity mean values among the posts outside the root canal and among the posts under the other conditions, and the t unpaired test to compare the radiopacity between the posts and the dentin, and between the posts and the root canal space. There was no statistically significant difference in radiopacity between RP and RPM, and LP and WP. AP posts showed radiopacity values significantly lower than those for dentin. No statistically significant difference was found between posts (RP and AP) and the root canal space. A statistically significant difference was observed between the luted and non-luted posts; additionally, luted posts with and without tissue simulator showed no significant differences. Most of the cement-luted posts analyzed in this study were distinguishable from the density of adjacent dentin surfaces, allowing radiographic confirmation of the fit of the post in the canal. The success of using esthetic root canal posts depends mainly on the fit of the post within the canal.[1] The radiopacity of a post allows for radiographic imaging to be used to determine the fit, an important factor in a clinical perspective.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The biodegradability of animal wastes production was evaluated through a simplified methodology that allowed the verification of the applicability of anaerobic processes. The experiments were performed in bath reactors, with granular sludge of three origins: UASB reactor treating dairy effluent, UASB reactor treating swine effluent and UASB reactor treating effluent of slaughterhouse of poultry. The experiments (1) - dairy effluent and poultry slaughterhouse non-adapted sludge; (2) -swine effluent and poultry slaughterhouse non-adapted sludge; (3) - dairy effluent and poultry slaughterhouse adapted sludge; (4) - swine effluent and poultry slaughterhouse adapted sludge; (5) - dairy effluent and dairy sludge, and (6) - swine effluent and swine sludge were performed in Incubator Shaker, at a temperature of 35 °C, under agitation at a 150 rpm, for 5 minutes, every 1 hour. A substrat:biomass relationship of 0.5 was used. Kinetic models of Monod, Zero Order, First and Second Order were tested and it was verified that the First Order model provided the best adjustment. The apparent First Order kinetic parameter (k1) was estimated for the experiments 1; 2; 3; 4; 5, and 6, as 2.51 x 10-2; 2.49 x 10-2; 1.90 x 10-2; 3.09 x 10-2; 2.54 x 10-2; 4.09 x 10-2 h-1, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Base cutting and feeding into harvesters of plants lying close to the ground surface require an efficient sweeping action of the cutting mechanism. It is not the case of conventional sugarcane harvesters which have rigid blades mounted on discs capable to contaminate the cane with dirt as well as damage the ratoons. The objective of this work was to simulate the sweeping performance of a segmented base cutter. The model was developed using the laws of dynamic. Simulation included two rotational speeds (400 and 600 rpm), two cutting heights (0.12 and 0.13 m) and two disk tilting angles (-10º and -12º). The simulated sweeping angle varied between 56º and 193º, which are very promising as a mean to cutting and feeding cane sticks lying on the ground. Cutting height was the variable that affected sweeping action the most. This behavior indicates the need to have an automatic control of the cutting disk height in order to keep good sweeping performance as the harvester moves forward.