996 resultados para RO MEMBRANES


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Three novel of isomeric tetra-functional biphenyl acid chloride: 3,3',5,5'-biphenyl tetraacyl chloride (mm-BTEC), 2,2',4,4'-biphenyl tetraacyl chloride (om-BTEC), and 2,2',5,5'-biphenyl tetraacyl chloride (op-BTEC) were synthesized, and used as new monomers for the preparation of the thin film composite (TFC) reverse osmosis (RO) membranes through interfacial polymerization with m-phenylenediamine (MPDA). The results of membrane performance test showed that membranes prepared from om-BTEC and op-BTEC had higher flux at the expanse of rejection compared with membranes prepared from mm-BTEC.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Two novel of tri- and tetra-functional biphenyl acid chloride: 3,4',5-biphenyl triacyl chloride (BTRC) and 3,3',5,5'-biphenyl tetraacyl chloride (BTEC), were synthesized, and used as new monomers for the preparations of the thin film composite (TFC) reverse osmosis (RO) membranes. The TFC RO membranes were prepared on a polysulfone supporting film through interfacial polymerization with the two new monomers and m-phenylenediamine (MPD). The membranes were characterized for the permeation properties, chemical composition, d-space between polymer chains, hydrophilicity, membrane morphology including top surface and cross-section. Permeation experiment was employed to evaluate the membranes performance including salt rejection and water flux. The surface structure and chemical composition of membranes were analyzed by attenuated total reflectance infrared (ATR-IR) and X-ray photoelectronic spectroscopy (XPS). The results revealed that the active layer of membranes was composed of highly cross-linked aromatic polyamide with the functional acylamide (-CONH-) bonds. The TFC membranes prepared from biphenyl acid chloride exhibit higher salt rejection compared with that prepared from trimesoyl chloride (TMC) at the expanse of some flux.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The performance of ultrafiltration (UF) membranes with molecular weight cut off (MWCO) of 1000 and 3500 Da in clarifying sugar cane juice was investigated, as well as the performance of a nanofiltration (NF) membrane with MWCO of 200 Da and a reverse osmosis (RO) membrane in concentrating sugar cane juice. For both cases the sugar cane juice had been limed and partially clarified. The UF membranes were found to be effective at clarifying the sugar cane juice in terms of purity rise and reduction in turbidity, colour, starch and protein. A purity rise of approximately 6 was achieved by both UF membranes at trans-membrane pressures (TMP) from 15 to 25 bar. However, Brix reduction in the permeate was between 14.5 and 41.85% and 12.11 and 26.52% for 1000 Da and 3500 Da membranes respectively. For the 200 Da and RO membranes the Brix in the concentrate was increased from 7.65 to 12.3 after 3 hours of operation for the 200 Da membrane at a TMP of 10 bar, whilst the Brix in the concentrate was increased from 15.65 to 27.6 after 3 hours of operation for the RO membrane at a TMP of 35 bar. Overall, UF membranes were found to be unsuitable for clarification of sugar cane juice since significant amount of Brix is reduced in the permeate, whilst RO membranes were found to be effective for concentration of sugar cane juice.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

To study the possibility of producing better water quality from municipal wastewater, a membrane bioreactor (MBR) pilot plant with flat sheet (FS) and hollow fiber (HF) membranes coupled with another pilot plant equipped with nanofiltration (NF)/reverse osmosis (RO) membranes were operated to treat municipal wastewater from the wastewater treatment plant (WWTP) Rincón de León, Alicante (Spain). This study was focused on improving the quality of the permeate obtained from the MBR process when complemented by NF or RO stages with respect to salinity, organic matter and nutrients. Furthermore, the removal efficiencies of 10 EMPs were evaluated, comparing the reductions achieved between the wastewater treatment by MBR (adsorption to sludge and biodegradation) and the later treatment using NF or RO (mainly size exclusion). The results showed that the high quality of water was obtained which is appropriate for reuse with salinity removal efficiencies higher than 97%, 96% for total organic carbon (TOC), 91% for nitrates View the MathML sourceNO3- and 99% for total phosphorous (TP). High removal efficiencies were obtained for the majority of the analyzed EMP compounds.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Integration of renewable energy with desalination technologies has emerged as an attractive solution to augment fresh water supply sustainably. Fouling and scaling are still considered as limiting factors in membrane desalination processes. For brackish water treatment, pre-treatment of reverse osmosis (RO) feed water is a key step in designing RO plants avoiding membrane fouling. This study aims to compare at pilot scale the rejection efficiency of RO membranes with multiple pre-treatment options at different water recoveries (30, 35, 40, 45 and 50%) and TDS concentrations (3500, 4000, and 4500mg/L). Synthetic brackish water was prepared and performance evaluation were carried out using brackish water reverse osmosis (BWRO) membranes (Filmtec LC-LE-4040 and Hydranautics CPA5-LD-4040) preceded by 5 and 1μm cartridge filters, 0.02μm ultra-filtration (UF) membrane, and forward osmosis (FO) membrane using 0.25M NaCl and MgCl2 as draw solutions (DS). It was revealed that FO membrane with 0.25M MgCl2 used as a draw solution (DS) and Ultra-filtration (UF) membrane followed by Filmtec membrane gave overall 98% rejection but UF facing high fouling potential due to high applied pressure. Use of 5 and 1μm cartridge filter prior to Filmtec membrane also showed effective results with 95% salt rejection.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Most commercially available reverse osmosis (RO) and nanofiltration (NF) membranes are based on the thin film composite (TFC) aromatic polyamide membranes. However, they have several disadvantages including low resistance to fouling, low chemical and thermal stabilities and limited chlorine tolerance. To address these problems, advanced RO/NF membranes are being developed from polyimides for water and wastewater treatments. The following three projects have resulted from my research. (1) Positively charged and solvent resistant NF membranes. The use of solvent resistant membranes to facilitate small molecule separations has been a long standing industry goal of the chemical and pharmaceutical industries. We developed a solvent resistant membrane by chemically cross-linking of polyimide membrane using polyethylenimine. This membrane showed excellent stability in almost all organic solvents. In addition, this membrane was positively charged due to the amine groups remaining on the surface. As a result, high efficiency (> 95%) and selectivity for multivalent heavy metal removal was achieved. (2) Fouling resistant NF membranes. Antifouling membranes are highly desired for “all” applications because fouling will lead to higher energy demand, increase of cleaning and corresponding down time and reduced life-time of the membrane elements. For fouling prevention, we designed a new membrane system using a coating technique to modify membrane surface properties to avoid adsorption of foulants like humic acid. A layer of water-soluble polymer such as polyvinyl alcohol (PVA), polyacrylic acid (PAA), polyvinyl sulfate (PVS) or sulfonated poly(ether ether ketone) (SPEEK), was adsorbed onto the surface of a positively charged membrane. The resultant membranes have a smooth and almost neutrally charged surface which showed better fouling resistance than both the positively charged NF membranes and commercially available negatively charged NTR-7450 membrane. In addition, these membranes showed high efficiency for removal of multivalent ions (> 95% for both cations and anions). Therefore, these antifouling surfaces can be potentially used for water softening, water desalination and wastewater treatment in a membrane bioreactor (MBR) process. (3) Thermally stable RO membranes. Commercial RO membranes cannot be used at temperature higher than 45°C due to the use of polysulfone substrate, which often limits their applications in industries. We successfully developed polyimides as the membrane substrate for thermally stable RO membranes due to their high thermal resistance. The polyimide-based composite polyamide membranes showed desalination performance comparable to the commercial TFC membrane. However, the key advantage of the polyimide-based membrane is its high thermal stability. As the feed temperature increased from 25oC to 95oC, the water flux increased 5 - 6 times while the salt rejection almost kept constant. This membrane appears to provide a unique solution for hot water desalination and also a feasible way to improve the water productivity by increasing the operating temperature without any drop in salt rejection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Reverse osmosis (RO) membranes have been used extensively in water desalination plants, waste water treatment in industries, agricultural farms and drinking water production applications. The objective of this work is to impart antibacterial and antifungal activities to commercially available RO membrane used in water purification systems by incorporating biogenic silver nanoparticles (AgNPs) synthesized using Rosa indica wichuriana hybrid leaf extract. The morphology and surface topography of uncoated and AgNPs-coated RO membrane were studied using Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). Elemental composition of the AgNPs-coated RO membrane was analyzed by energy-dispersive X-ray spectroscopy (EDAX). The functional groups were identified by Fourier Transform Infrared spectroscopy (FT-IR). Hydrophilicity of the uncoated and AgNPs-coated RO membrane was analyzed using water contact angle measurements. The thermal properties were studied by thermogravimetric analysis (TGA). The AgNPs incorporated RO membrane exhibited good antibacterial and antifungal activities against pathogenic bacterial strains such as E. coli, S. aureus, M. luteus, K. pneumoniae, and P. aeruginosa and fungal strains such as Candida tropicalis, C. krusei, C. glabrata, and C. albicans.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

For polyamide used in reverse osmosis (RO) membranes, the content of pendant acid groups is critical to its performance. In this work, FTIR was used to analyze the acid contents in the polyamide films prepared via interfacial polymerization of trimesic acid trichloride (TMC) in hexane and 1,3-phenylenediamine (MPDA) in water, and the effects of reaction conditions, including monomer concentrations, time, and temperature, were studied. It was found that more pendant acid groups are present in the polyramide film at higher TMC concentrations or lower MPDA concentrations, and longer reaction times and lower temperatures also favor the formation of the free acids. These results can be explained by the monomer diffusion in the interfacial polymerization process. This work may help the design and fabrication of RO membranes with different hydrophilicity and target performance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Reverse osmosis (RO) is currently one of the most prevalent methods used for seawater desalination. During the past four decades, the research anddevelopment has reduced the energy consumption from about 20 to 4 kWh/m3, while improvements in membrane science has led to a 20-fold increase in the specific membrane flux. Nevertheless, research is still underway to reduce the operation and maintenance problems and thus improve the performance of RO systems. The most important maintenance problem associated with RO operation is the membrane fouling, especially biological fouling (biofouling). This work focuses on the aspects to eliminate biofouling in RO membranes, by adopting a proper pretreatment system. The experimental results revealed that fluidized bed biological granular activated carbon, at 15 min empty bed contact time (with dissolved organic carbon, DOC concentration of 6–8 mg/L) can be utilized effectively to remove nearly 100% biodegradable DOC from seawater. Continuous experiments of membrane bioreactor (MBR) have been conducted concomitantly to gain insight into the long-term effects of MBR on biodegradable organic content removal and biofouling control. The results show that MBR system produced better effluent with 78% DOC removal and quasi-total biodegradable DOC removal. Dissolved oxygen was not a limiting factor for the DOC degradation. Short-term experimental runs were conducted with RO membrane using both pretreated and non-pretreated seawater. The results showed that filtrate from MBR yielded the highest permeate flux improvement, which was approximately 300% compared with non-pretreated seawater.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Seawater desalination has significantly developed towards membrane technology than phase change process during last decade. Seawater reverse osmosis (SWRO) in general is the most familiar process due to higher water recovery and lower energy consumption compared to other available desalination processes. Despite major advancements in SWRO technology, desalination industry is still facing significant amount of practical issues. Therefore, the potentials and problems faced by current SWRO industries and essential study areas are discussed in this review for the benefit of desalination industry. It is important to consider all the following five components in SWRO process i.e. (1) intake (2) pre-treatment (3) high pressure pumping (4) membrane separation (performance of membranes and brine disposal) and (5) product quality. Development of higher corrosion resistant piping materials or coating materials, valves, and pumps is believed to be in higher research demand. Furthermore, brine management, that includes brine disposal and resource recovery need further attention. Pre-treatment sludge management and reduced cleaning in place flush volume will reduce the capital costs associated with evaporation ponds and the maintenance costs associated with disposal and transportation reducing the unit cost of water. © 2013 Springer Science+Business Media Dordrecht.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Desalination of groundwater is essential in arid regions that are remote from both seawater and freshwater resources. Desirable features of a groundwater desalination system include a high recovery ratio, operation from a sustainable energy source such as solar, and high water output per unit of energy and land. Here we propose a new system that uses a solar-Rankine cycle to drive reverse osmosis (RO). The working fluid such as steam is expanded against a power piston that actuates a pump piston which in turn pressurises the saline water thus passing it through RO membranes. A reciprocating crank mechanism is used to equalise the forces between the two pistons. The choice of batch mode in preference to continuous flow permits maximum energy recovery and minimal concentration polarisation in the vicinity of the RO membrane. This study analyses the sizing and efficiency of the crank mechanism, quantifies energy losses in the RO separation and predicts the overall performance. For example, a system using a field of linear Fresnel collectors occupying 1000 m2 of land and raising steam at 200 °C and 15.5 bar could desalinate 350 m3/day from saline water containing 5000 ppm of sodium chloride with a recovery ratio of 0.7.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In brackish groundwater desalination, high recovery ratio (of fresh water from saline feed) is desired to minimise concentrate reject. To this effect, previous studies have developed a batch reverse osmosis (RO) desalination system, DesaLink, which proposed to expand steam in a reciprocating piston cylinder and transmit the driving force through a linkage crank mechanism to pressurise batches of saline water (recirculating) in a water piston cylinder unto RO membranes. However, steam is largely disadvantaged at operation from low temperature (< 150oC) thermal sources; and organic working fluids are more viable, though, the obtainable thermal cycle efficiencies are generally low with low temperatures. Consequently, this thesis proposed to investigate the use of organic working fluid Rankine cycle (ORC) with isothermal expansion, to drive the DesaLink machine, at improved thermal efficiency from low temperature thermal sources. Following a review of the methods of achieving isothermal expansion, ‘liquid flooded expansion’ and ‘expansion chamber surface heating’ were identified as potential alternative methods. Preliminary experimental comparative analysis of variants of the heated expansion chamber technique of effecting isothermal expansion favoured a heated plain wall technique, and as such was adopted for further optimisation and development. Further, an optimised isothermal ORC engine was built and tested at < 95oC heat source temperature, with R245fa working fluid – which was selected from 16 working fluids that were analysed for isothermal operation. Upon satisfactory performance of the test engine, a larger (10 times) version was built and coupled to drive the DesaLink system. Operating the integrated ORC-RO DesaLink system, gave freshwater (approximately 500 ppm) production of about 12 litres per hour (from 4000 ppm feed water) at a recovery ratio of about 0.7 and specific energy consumption of 0.34 kWh/m3; and at a thermal efficiency of 7.7%. Theoretical models characterising the operation and performance of the integrated system was developed and utilised to access the potential field performance of the system, when powered by two different thermal energy sources – solar and industrial bakery waste heat – as case studies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, permeate from a hollow fiber polyethylene (PE) membrane bio-reactor (MBR) system treating synthetic agricultural wastewater was fed into a cellulose acetate brackish water reverse osmosis (BWRO30 2540) membrane system; three different trans-membranes pressures (TMPs) of 1000, 2500, and 4000 kPa were selected to evaluate the system performance in terms of general operating parameters as well as the removal of chosen important potential fouling water quality parameters. The results showed that highest corrected permeate flux rate was at a TMP of 2500 kPa, whereas lowest recorded at a TMP of 4000 kPa. Similar situation prevailed in water recovery rate. But temperature corrected specific fluxes decreased as the applied TMPs increased. In all selected TMPs, more than 96% of salinity was removed. Permeate from MBR as feed to reverse osmosis required frequent chemical cleaning than the microfiltration/ultrafiltration (MF/UF) permeates and granular media filter (GMF) filtered in order to maintain the required rate of product water. One of the reasons for this frequent chemical cleaning is due to higher total organic carbon as well as total nitrogen (TN) in the MBR permeate. This result needs to be further evaluated through field trials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main objectives of this dissertation were: (i) to develop experimental and analytical procedures to quantify different physico-chemical properties of the ultra-thin (~ 100 nm) active layers of reverse osmosis (RO) and nanofiltration (NF) membranes and their interactions with contaminants; (ii) to use such procedures to evaluate the similarities and differences between the active layers of different RO/NF membranes; and (iii) to relate characterization results to membrane performance. Such objectives were motivated by the current limited understanding of the physico-chemical properties of active layers as a result of traditional characterization techniques having limitations associated with the nanometer-scale spatial resolution required to study these ultra-thin films. Functional groups were chosen as the main active layer property of interest. Specific accomplishments of this study include the development of procedures to quantify in active layers as a function of pH: (1) the concentration of both negatively and positively ionized functional groups; (2) the stoichiometry of association between ions (i.e., barium) and ionized functional groups (i.e., carboxylate and sulfonate); and (3) the steric effects experienced by ions (i.e., barium). Conceptual and mathematical models were developed to describe experimental results. The depth heterogeneity of the active layer physico-chemical properties and interactions with contaminants studied in this dissertation was also characterized. Additionally, measured concentrations of ionized functional groups in the polyamide active layers of several commercial RO/NF membranes were used as input in a simplified RO/NF transport model to predict the rejection of a strong electrolyte (i.e., potassium iodide) and a weak acid (i.e., arsenious acid) at different pH values based on rejection results at one pH condition. The good agreement between predicted and experimental results showed that the characterization procedures developed in this study serve as useful tools in the advancement of the understanding of the properties and structure of the active layers of RO/NF membranes, and the mechanisms of contaminant transport through them.