302 resultados para RELAYS
Resumo:
A microgrid provides economical and reliable power to customers by integrating distributed resources more effectively. Islanded operation enables a continuous power supply for loads during a major grid disturbance. Reliability of a microgrid can be further increased by forming a mesh configuration. However, the protection of mesh microgrids is a challenging task. In this paper, protection schemes are discussed using current differential protection of a microgrid. The protection challenges associated with bi-directional power flow, meshed configuration, changing fault current level due to intermittent nature of DGs and reduced fault current level in an islanded mode are considered in proposing the protection solutions. Relay setting criterion and current transformer (CT) selection guidelines are also discussed. The results are verified using MATLAB calculations and PSCAD simulations.
Resumo:
Distributed generators (DGs) are defined as generators that are connected to a distribution network. The direction of the power flow and short-circuit current in a network could be changed compared with one without DGs. The conventional protective relay scheme does not meet the requirement in this emerging situation. As the number and capacity of DGs in the distribution network increase, the problem of coordinating protective relays becomes more challenging. Given this background, the protective relay coordination problem in distribution systems is investigated, with directional overcurrent relays taken as an example, and formulated as a mixed integer nonlinear programming problem. A mathematical model describing this problem is first developed, and the well-developed differential evolution algorithm is then used to solve it. Finally, a sample system is used to demonstrate the feasiblity and efficiency of the developed method.
Resumo:
Abstract—In this paper we investigate the capacity of a general class of the slotted amplify and forward (SAF) relaying protocol where multiple, though a finite number of relays may transmit in a given cooperative slot and the relay terminals being half-duplex have a finite slot memory capacity. We derive an expression for the capacity per channel use of this generalized SAF channel assuming all source to relay, relay to destination and source to destination channel gains are independent and modeled as complex Gaussian. We show through the analysis of eigenvalue distributions that the increase in limiting capacity per channel use is marginal with the increase of relay terminals.
Resumo:
In recent years, some models have been proposed for the fault section estimation and state identification of unobserved protective relays (FSE-SIUPR) under the condition of incomplete state information of protective relays. In these models, the temporal alarm information from a faulted power system is not well explored although it is very helpful in compensating the incomplete state information of protective relays, quickly achieving definite fault diagnosis results and evaluating the operating status of protective relays and circuit breakers in complicated fault scenarios. In order to solve this problem, an integrated optimization mathematical model for the FSE-SIUPR, which takes full advantage of the temporal characteristics of alarm messages, is developed in the framework of the well-established temporal constraint network. With this model, the fault evolution procedure can be explained and some states of unobserved protective relays identified. The model is then solved by means of the Tabu search (TS) and finally verified by test results of fault scenarios in a practical power system.
Resumo:
Background Few studies have examined acute injuries in track and field in both elite and sub-elite athletes. Purpose To observe the absolute and relative rates of injury in track and field athletes across a wide range of competition levels and ages during three years of the Penn Relays Carnival to assist with future medical coverage planning and injury prevention strategies. Study design: Descriptive epidemiology study. Methods Over a 3-year period all injuries treated by the medical staff were recorded on a standardised injury report form. Absolute injury rates (absolute number of injuries) and relative injury rates (number of injuries per 1000 participants) were determined and odds ratios (OR) of injury rates were calculated between sexes, competition levels and events. Injuries were also broken down into major or minor medical or orthopedic injuries. Results Throughout the study period 48,473 competing athletes participated in the Penn Relays Carnival, and 436 injuries were sustained. For medical coverage purposes, the relative rate of injury subtypes was greatest for minor orthopedic injuries (5.71 injuries per 1000 participants), followed by minor medical injuries (3.42 injuries per 1000 participants), major medical injuries (0.69 injuries per 1000 participants) and major orthopedic injuries (0.18 injuries per 1000 participants). College/elite level athletes displayed the lowest relative injury rate (7.99 injuries per 1000 participants), which was significantly less than high school (9.87 injuries per 1000 participants) and masters level athletes (16.33 injuries per 1000 participants). Males displayed a greater likelihood of suffering a minor orthopedic injury compared to females (OR = 1.36, 95% CI = 1.06 to 1.75; χ2 = 5.73, p = 0.017) but were less likely to sustain a major medical injury (OR = 0.33, 95% CI = 0.15 to 0.75; χ2 = 7.75, p = 0.005). Of the three most heavily participated in events, the 4 x 400m relay displayed the greatest relative injury rate (13.6 injuries per 1000 participants) compared to the 4 x 100 and 4 x 200m relay. Conclusions Medical coverage teams for future large scale track and field events need to plan for at least two major orthopedic and seven major medical injuries per 1000 participants. Male track and field athletes, particularly masters level male athletes, are at greater risk of injury compared to other genders and competition levels.
Resumo:
While the implementation of the IEC 61850 standard has significantly enhanced the performance of communications in electrical substations, it has also increased the complexity of the system. Subsequently, these added elaborations have introduced new challenges in relation to the skills and tools required for the design, test and maintenance of 61850-compatible substations. This paper describes a practical experience of testing a protection relay using a non-conventional test equipment; in addition, it proposes a third party software technique to reveal the contents of the packets transferred on the substation network. Using this approach, the standard objects can be linked and interpreted to what the end-users normally see in the IED and test equipment proprietary software programs.
Resumo:
Distributed space time coding for wireless relay networks when the source, the destination and the relays have multiple antennas have been studied by Jing and Hassibi. In this set-up, the transmit and the receive signals at different antennas of the same relay are processed and designed independently, even though the antennas are colocated. In this paper, a wireless relay network with single antenna at the source and the destination and two antennas at each of the R relays is considered. A new class of distributed space time block codes called Co-ordinate Interleaved Distributed Space-Time Codes (CIDSTC) are introduced where, in the first phase, the source transmits a T-length complex vector to all the relays;and in the second phase, at each relay, the in-phase and quadrature component vectors of the received complex vectors at the two antennas are interleaved and processed before forwarding them to the destination. Compared to the scheme proposed by Jing-Hassibi, for T >= 4R, while providing the same asymptotic diversity order of 2R, CIDSTC scheme is shown to provide asymptotic coding gain with the cost of negligible increase in the processing complexity at the relays. However, for moderate and large values of P, CIDSTC scheme is shown to provide more diversity than that of the scheme proposed by Jing-Hassibi. CIDSTCs are shown to be fully diverse provided the information symbols take value from an appropriate multidimensional signal set.
Resumo:
This letter presents the development of simplified algorithms based on Haar functions for signal extraction in relaying signals. These algorithms, being computationally simple, are better suited for microprocessor-based power system protection relaying. They provide accurate estimates of the signal amplitude and phase.
Resumo:
This paper presents a general hardware scheme for testing protective relays using microprocessor based systems. The microprocessor simulates the relaying signals for test purpose and monitors the relay performance. Based on the proposed hardware, a teat procedure for directional overcurrent relays is presented in detail. Typical test results of various routine tests conducted on a commercial single phase directional over-current relay clearly demonstrate the efficacy of the proposed technique for conducting tests on commercial relays.
Resumo:
The use of energy harvesting (EH) nodes as cooperative relays is a promising and emerging solution in wireless systems such as wireless sensor networks. It harnesses the spatial diversity of a multi-relay network and addresses the vexing problem of a relay's batteries getting drained in forwarding information to the destination. We consider a cooperative system in which EH nodes volunteer to serve as amplify-and-forward relays whenever they have sufficient energy for transmission. For a general class of stationary and ergodic EH processes, we introduce the notion of energy constrained and energy unconstrained relays and analytically characterize the symbol error rate of the system. Further insight is gained by an asymptotic analysis that considers the cases where the signal-to-noise-ratio or the number of relays is large. Our analysis quantifies how the energy usage at an EH relay and, consequently, its availability for relaying, depends not only on the relay's energy harvesting process, but also on its transmit power setting and the other relays in the system. The optimal static transmit power setting at the EH relays is also determined. Altogether, our results demonstrate how a system that uses EH relays differs in significant ways from one that uses conventional cooperative relays.
Resumo:
In this paper, the performance of distance relays when applied to transmission system equipped with shunt FACTS device, Static Synchronous Compensator (STATCOM) is described. The aim of the proposed study is to evaluate the performance of distance relays when STATCOM is incorporated at the mid point of transmission lines for voltage control. A detailed model of STATCOM and its control strategy is presented. The presence of these devices significantly affects apparent impedance seen by the distance relays due to their rapid response to different power system configurations. The distance relay is evaluated for different loading conditions and for different fault locations. The faults are created during various pre-fault loading conditions. The studies are performed on 400KV and 132KV systems and the results are presented. Simulation studies are carried out using transient simulation software, PSCAD/EMTDC.
Resumo:
Fixed and mobile relays are used, among other applications, in the downlink of cellular communications systems. Cooperation between relays can greatly increase their benefits in terms of extended coverage, increased reliability, and improved spectral efficiency. In this paper, we introduce the fundamental notion of asymmetric cooperation. For this, we consider a two-phase transmission protocol where, in the first phase, the base station (BS) sends several available messages to the relays over wireless links. But, depending on the channel state and the duration of the BS transmission, not all relays decode all messages. In a second phase, the relays, which may now have asymmetric message knowledge, use cooperative linear precoding for the transmission to the mobile stations. We show that for many channel configurations, asymmetric cooperation, although (slighlty) sub-optimum for the second phase, is optimum from a total-throughput point of view, as it requires less time and energy in the first phase. We give analytical formulations for the optimum operating parameters and the achievable throughput, and show that under typical circumstances, 20-30% throughput enhancement can be achieved over conventional systems.