4 resultados para R744


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, one of the current control algorithms for the R744 cycle, which tries tooptimize the performance of the system by two SISO control loops, is compared to acost-effective system with just one actuator. The operation of a key component of thissystem, a two stage orifice expansion valve is examined in a range of typical climateconditions. One alternative control loop for this system, which has been proposed byBehr group, is also scrutinized.The simulation results affirm the preference of using two control-loops instead of oneloop, but refute advantages of the Behr alternate control approach against one-loopcontrol. As far as the economic considerations of the A/C unit are concerned, usinga two-stage orifice expansion valve is desired by the automotive industry, thus basedon the experiment results, an improved logic for control of this system is proposed.In the second part, it is investigated whether the one-actuator control approach isapplicable to a system consisting of two parallel evaporators to allow passengers tocontrol different climate zones. The simulation results show that in the case of usinga two-stage orifice valve for the front evaporator and a fixed expansion valve forthe rear one, a proper distribution of the cooling power between the front and rearcompartment is possible for a broad range of climate conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Almost identical polyglutamine-containing proteins with unknown structures have been found in human, mouse and rat genomes (GenBank AJ277365, AF525300, AY879229). We infer that an identical new gene (RING) finger domain of real interest is located in each C-terminal segment. A three-dimensional (3-D) model was generated by remote homology modeling and the functional implications are discussed. The model consists of 65 residues from terminal position 707 to 772 of the human protein with a total length of 796 residues. The 3-D model predicts a ubiquitin-protein ligase (E3) as a binding site for ubiquitin-conjugating enzyme (E2). Both enzymes are part of the ubiquitin pathway to label unwanted proteins for subsequent enzymatic degradation. The molecular contact specificities are suggested for both the substrate recognition and the residues at the possible E2-binding surface. The predicted structure, of a ubiquitin-protein ligase (E3, enzyme class number 6.3.2.19, CATH code 3.30.40.10.4) may contribute to explain the process of ubiquitination. The 3-D model supports the idea of a C3HC4-RING finger with a partially new pattern. The putative E2-binding site is formed by a shallow hydrophobic groove on the surface adjacent to the helix and one zinc finger (L722, C739, P740, P741, R744). Solvent-exposed hydrophobic amino acids lie around both zinc fingers (I717, L722, F738, or P765, L766, V767, V733, P734). The 3-D structure was deposited in the protein databank theoretical model repository (2B9G, RCSB Protein Data Bank, NJ).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Il seguente lavoro di tesi ha come obiettivo lo studio delle prestazioni energetiche di una pompa di calore elio-assistita, reversibile e multi-sorgente, la quale combina la tecnologia delle pompe di calore aria-acqua con quella dei collettori solari ibridi termo-fotovoltaici. L’impianto oggetto di studio è situato presso il centro di ricerca ENEA Casaccia ed è stato sviluppato con lo scopo di soddisfare la richiesta di riscaldamento/raffrescamento e produzione di acqua calda di un edificio residenziale o commerciale. In questo elaborato si è analizzato il funzionamento invernale della pompa di calore finalizzato alla produzione di acqua calda sanitaria, confrontando due modalità operative differenti con diverse impostazioni di lavoro della frequenza del compressore e della valvola di laminazione. L’elemento distintivo delle due modalità operative è il componente avente la funzione di evaporatore in quanto in una modalità è stata impiegata una batteria alettata con ventilazione forzata, mentre nell’altra un campo di pannelli termo-fotovoltaici. I risultati ottenuti dalle prove sperimentali hanno evidenziato migliori prestazioni della pompa di calore con i collettori ibridi termo-fotovoltaici, in caso di presenza di elevati valori di irraggiamento solare. Elemento di innovazione dell’impianto sperimentale è l’utilizzo del fluido naturale R744 (CO2) come refrigerante il quale viene sfruttato anche per raffreddare le celle fotovoltaiche comportando in questo modo, un doppio effetto utile all’impianto stesso: miglioramento del rendimento elettrico dei collettori solari e contemporaneamente un incremento della temperatura di evaporazione con conseguente beneficio sulle prestazioni della pompa di calore.