997 resultados para R-134A


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article examines, through a molecular perspective, the 'ozone-friendly' refrigerants R-134a and R-123 vis-à-vis R-12 and R-11, which are targeted to be phased out under the Montreal Protocol on Substances that Deplete the Ozone Layer, Final Act (1987). It appears that the molecular weight, size parameter, and dipole moment, of R-134a and R-123, may induce a pronounced effect on the chemical equilibrium of ice particles in the polar stratospheric clouds and subsequently influence the photochemical reactions therein. Non-polar, high-molecular-weight perfluoropropane (R-218), could be a better substitute for R-12, while R-134, which is a non-polar HFC of the ethane family, could also be a candidate although its molecular weight is lower than that of R-12. The search for a good substitute for R-11, however, must continue.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A comparative study has been carried out of R-12, 22, 125, 134a, 152a, 218, 245, 500, 502, 507 and 717 as working fluids in a vapour-compression refrigeration system. Two performance parameters were defined, which are expressed in reduced quantities for a corresponding-states comparison of these refrigerants in the temperature range -20 to 50-degrees-C. One is based on the product of temperature drop to pressure penalty ratio and the available volumetric heat of vaporisation at the evaporator; the other considers the effect of isentropic compression in the ideal gas state. It was shown that R-125, 507 and 218 could be better alternatives to R-12 than R-134a. Among these, R-218 has a lower maximum cycle pressure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Capillary pumped loop (CPL) and loop heat pipe (LHP) are passive two-phase heat transport devices. They have been gaining importance as a part of the thermal control system of spacecraft. The evaporation heat transfer coefficient at the tooth-wick interface of an LHP or CPL has a significant impact on the evaporator temperature. It is also the main parameter in sizing of a CPL or LHP. Experimentally determined evaporation heat transfer coefficients from a three-port CPL with tubular axially grooved (TAG) evaporator and a TAG LHP with acetone, R-134A, and ammonia as working fluids are presented in this paper. The influences of working fluid, hydrodynamic blocks in the core, evaporator configuration (LHP or CPL), and adverse elevation (evaporator above condenser) on the heat transfer coefficient are presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The heat of adsorption of methane, ethane, carbon dioxide, R-507a and R-134a on several specimens of microporous activated carbons is derived from experimental adsorption data fitted to the Dubinin-Astakhov equation. These adsorption results are compared with literature data obtained from calorimetric measurements and from the pressure-temperature relation during isosteric heating/cooling. Because the adsorbed phase volume plays an important role, its dependence on temperature and pressure needs to be correctly assessed. In addition, for super-critical gas adsorption, the evaluation of the pseudo-saturation pressure also needs a judicious treatment. Based on the evaluation of carbon dioxide adsorption, it can be seen that sub-critical and super-critical adsorption show different temperature dependences of the isosteric heat of adsorption. The temperature and loading dependence of this property needs to be taken into account while designing practical systems. Some practical implications of these findings are enumerated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper reports an experimental investigation of oscillating temperature field beneath a single isolated nucleation site using a non-invasive TLC (thermochromic liquid crystal) based thermography technique. Empirical correlations are presented to demonstrate the influence of system pressure and wall heat flux on different ebullition characteristics in the nucleate pool boiling regime of refrigerant R-134a. TLC transient response and two-phase flow structure are captured using synchronized, high resolution imaging. It is observed that the area of influence of nucleation site exhibits a two-part distinct transient behavior during the bubble growth period and broadens to a maximum of 1.57 times the bubble diameter at the instant of bubble departure. This is accompanied by a sharp fall of 2.5 degrees C in the local excess temperature at the nucleation site, which results in momentary augmentation (similar to 40%) in the local heat transfer coefficient at the nucleation origin. The enhanced heat transfer rate observed during the bubble peel-off event is primarily due to transient micro-convection in the wake of the retreating bubble. Further, the results indicate that a slight increase in system pressure from 813.6 to 882.5 kPa has no considerable effect on either the wall superheat or the overall heat transfer coefficient and ebullition frequency. In addition, correlations have been obtained for bubble Reynolds number, Jackob number and the dimensionless bubble generation frequency in terms of modified boiling number.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

From what was stated in the Montreal Protocol, the researchers and refrigeration industry seek substitutes for synthetic refrigerants -chlorofluorocarbons (CFCs) and HCFCs (HCFC) - that contribute to the depletion of the ozone layer. The phase-out of these substances was started using as one of the replacement alternatives the synthetic fluids based on hydro fluorocarbons (HFCs) that have zero potential depletion of the ozone layer. However, contribute to the process of global warming. HFC refrigerants are greenhouse gases and are part of the group of gases whose emissions must be reduced as the Kyoto Protocol says. The hydrocarbons (HC's), for not contribute to the depletion of the ozone layer, because they have very low global warming potential, and are found abundantly in nature, has been presented as an alternative, and therefore, are being used in new home refrigeration equipment in several countries. In Brazil, due to incipient production of domestic refrigerators using HC's, the transition refrigerants remain on the scene for some years. This dissertation deals with an experimental evaluation of the conduct of a drinking fountain designed to work with HFC (R-134a), operating with a mixture of HC's or isobutane (R-600a) without any modification to the system or the lubricating oil. In the refrigeration laboratory of Federal University of Rio Grande do Norte were installed, in a drinking fountain, temperature and pressure sensors at strategic points in the refrigeration cycle, connected to an acquisition system of computerized data, to enable the mapping and thermodynamics analysis of the device operating with R-134a or with a mixture of HC's or with R-600a. The refrigerator-test operating with the natural fluids (mixture of HC's or R-600a) had a coefficient of performance (COP) lower than the R-134a

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work presents a numerical model to simulate refrigerant flow through capillary tubes, commonly used as expansion devices in refrigeration systems. The flow is divided in a single-phase region, where the refrigerant is in the subcooled liquid state, and a region of two-phase flow. The capillary tube is considered straight and horizontal. The flow is taken as one-dimensional and adiabatic. Steady-state condition is also assumed and the metastable flow phenomena are neglected. The two-fluid model, considering the hydrodynamic and thermal non-equilibrium between the liquid and vapor phases, is applied to the two-phase flow region. Comparisons are made with experimental measurements of the mass flow rate and pressure distribution along two capillary tubes working with refrigerant R-134a in different operating conditions. The results indicate that the present model provides a better estimation than the commonly employed homogeneous model. Some computational results referring to the quality, void fraction, velocities, and temperatures of each phase are presented and discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents experimental results for flow boiling heat transfer coefficient and critical heat flux (CHF) in small flattened tubes. The tested flattened tubes have the same equivalent internal diameter of 2.2 mm, but different aspect height/width ratios (H/W) of 1/4, 1/2, 2 and 4. The experimental data were compared against results for circular tubes using R134a and R245fa as working fluids at a nominal saturation temperature of 31 degrees C. For mass velocities higher than 200 kg/m(2)s, the flattened and circular tubes presented similar heat transfer coefficients. Such a behavior is related to the fact that stratification effects are negligible under conditions of higher mass velocities. Heat transfer correlations from the literature, usually developed using only circular-channel experimental data, predicted the flattened tube results for mass velocities higher than 200 kg/m(2)s with mean absolute error lower than 20% using the equivalent diameter to account for the geometry effect. Similarly, the critical heat flux results were found to be independent of the tube aspect ratio when the same equivalent length was kept. Equivalent length is a new parameter which takes into account the channel heat transfer area. The CHF correlations for round tubes predicted the flattened tube data relatively well when using the equivalent diameter and length. Furthermore, a new proposed CHF correlation predicted the present flattened tube data with a mean absolute error of 5%. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The reduction in energy consumption is the main requirement to be satisfied in refrigeration and air conditioning by mechanical vapor compression system. In automotive system isn´t different. Thermal analyses in these systems are crucial for a better performance in automotive air conditioner. This work aims to evaluate the conditions of use of R134A refrigerant (used in vehicles) and compare with R437A (alternative refrigerant), varying the speed of the electric fan in the evaporator. All tests were performed in automotive air conditioning unit ATR600, simulating the thermal conditions of the system. The equipment is instrumented for data acquisition temperature, condensation and evaporation pressures and electrical power consumed to determine the coefficient of performance of the cycle. The system was tested under rotations of 800, 1600 and 2400 rpm with constant load of R- 134a. It occurred with the same conditions with R437A. Both recommended by the manufacturer. The results show that the best system performance occurs in the rotation of 800 RPM for both refrigerants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hoje em dia a preocupação ambiental e a economia são fatores de sustentabilidade que são tidos em conta em países desenvolvidos, especialmente no seio da União Europeia. Reduzir os consumos de energia é, portanto, um ponto-chave para a redução das emissões de gases com efeito de estufa e aumentar a dependência das energias renováveis. Consequentemente surge então a necessidade de aumentar a eficiência dos equipamentos, em particular no presente caso, equipamentos de refrigeração. Para isso foi adotado pela Comissão Europeia uma rotulagem nos produtos consumidores de energia, em particular na refrigeração, os frigoríficos e congeladores domésticos permitindo informar o consumidor para os equipamentos mais eficientes. Mais recentemente, frigoríficos comerciais e profissionais também terão obrigatoriedade de incluir um rótulo energético na parte externa dos mesmos. Nesses rótulos estão incluídas várias informações técnicas do aparelho representadas de uma forma compreensível e lúdica aos olhos do consumidor mais leigo, entre as quais as classes de eficiência energética. As classes de eficiência energética caracterizam-se pela componente tecnológica dos frigoríficos. Perceber quais os componentes e materiais em particular que promovem uma melhor eficiência, quantificar a sua influência e avaliar os seus custos de integração torna-se assim essencial para toda a cadeia envolvida na produção destes equipamentos. Os fluídos frigorigénios e compressores aparentam ser os que mais exercem influência na eficiência de frigoríficos de baixa potência. Tubos capilares com trocador de calor são uma escolha mais eficiente comparado com o tubo capilar padrão que é utilizado nestes frigoríficos. Por forma a obter informação adicional e relevante do ponto de vista da análise energética realizaram-se simulações para determinação do consumo elétrico anual com recurso ao software Pack Calculation Pro. Entre os fluídos frigorigénios R-134a, R-22 e R-410a, os compressores scroll apresentaram consumos mais reduzidos (no máximo de 16%) do que os compressores alternativos. No caso do amoníaco (R-717) os compressores alternativos consumiram em média 14% menos do que os compressores parafuso. O recurso a velocidade variável em compressores permite reduzir o consumo na ordem dos 25%. Válvulas de expansão eletrónicas trazem reduções no consumo de 1,5% quando comparadas com válvulas de expansão termostáticas em compressores de velocidade variável. O propano (R-290) é um gás que mostra ter um melhor desempenho do que o R-134a e R404a em vários compressores, consumindo 16% menos do que o R-404a. Em função da temperatura exterior, o R-290 também apresentou um bom desempenho consumindo em climas quentes (Belém, Brasil) 24% menos do que o R-404a.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

HFC-134a (CF3CH2F) is the most rapidly growing hydrofluorocarbon in terms of atmospheric abundance. It is currently used in a large number of household refrigerators and air-conditioning systems and its concentration in the atmosphere is forecast to increase substantially over the next 50–100 years. Previous estimates of its radiative forcing per unit concentration have differed significantly 25%. This paper uses a two-step approach to resolve this discrepancy. In the first step six independent absorption cross section datasets are analysed. We find that, for the integrated cross section in the spectral bands that contribute most to the radiative forcing, the differences between the various datasets are typically smaller than 5% and that the dependence on pressure and temperature is not significant. A “recommended'' HFC-134a infrared absorption spectrum was obtained based on the average band intensities of the strongest bands. In the second step, the “recommended'' HFC-134a spectrum was used in six different radiative transfer models to calculate the HFC-134a radiative forcing efficiency. The clear-sky instantaneous radiative forcing, using a single global and annual mean profile, differed by 8%, between the 6 models, and the latitudinally-resolved adjusted cloudy sky radiative forcing estimates differed by a similar amount.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Industrial employment growth has been one of the most dynamic areas of expansion in Asia; however, current trends in industrialised working environments have resulted in greater employee stress. Despite research showing that cultural values affect the way people cope with stress, there is a dearth of psychometrically established tools for use in non-Western countries to measure these constructs. Studies of the "Way of Coping Checklist-Revised" (WCCL-R) in the West suggest that the WCCL-R has good psychometric properties, but its applicability in the East is still understudied. A confirmatory factor analysis (CFA) is used to validate the WCCL-R constructs in an Asian population. This study used 1,314 participants from Indonesia, Sri Lanka, Singapore, and Thailand. An initial exploratory factor analysis revealed that original structures were not confirmed; however, a subsequent EFA and CFA showed that a 38-item, five-factor structure model was confirmed. The revised WCCL-R in the Asian sample was also found to have good reliability and sound construct and concurrent validity. The 38-item structure of the WCCL-R has considerable potential in future occupational stress-related research in Asian countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study aims to investigate the non-linear relationship between the JD-R model and work engagement. Previous research has identified linear relationships between these constructs; however there are strong theoretical arguments for testing curvilinear relationships (e.g., Warr, 1987). Data were collected via a self-report online survey from officers of one Australian police service (N = 2,626). Results demonstrated a curvilinear relationship between job demands and job resources and engagement. Gender (as a control variable) was also found to be a significant predictor of work engagement. The results indicated that male police officers experienced significantly higher job demands and colleague support than female officers. However, female police officers reported significantly higher levels of work engagement than male officers. This study emphasises the need to test curvilinear relationships, as well as simple linear associations, when measuring psychological health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Significant sums of money are invested in developing technological innovations that have low levels and rates of adoption. Several approaches have been put forward in an effort to improve rates of adoption. This paper presents the results of study that examined the innovation fit of key technological innovations in the beef industry. Findings indicate that be assessing the innovation fit throughout the R&D process researchers and end users can collaborate to improve the innovation fit and the rate of adoption. The paper also put forward a model that demonstrates the linkages between R&D, adoption and innovation fit.