980 resultados para QA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study used automated data processing techniques to calculate a set of novel treatment plan accuracy metrics, and investigate their usefulness as predictors of quality assurance (QA) success and failure. 151 beams from 23 prostate and cranial IMRT treatment plans were used in this study. These plans had been evaluated before treatment using measurements with a diode array system. The TADA software suite was adapted to allow automatic batch calculation of several proposed plan accuracy metrics, including mean field area, small-aperture, off-axis and closed-leaf factors. All of these results were compared the gamma pass rates from the QA measurements and correlations were investigated. The mean field area factor provided a threshold field size (5 cm2, equivalent to a 2.2 x 2.2 cm2 square field), below which all beams failed the QA tests. The small aperture score provided a useful predictor of plan failure, when averaged over all beams, despite being weakly correlated with gamma pass rates for individual beams. By contrast, the closed leaf and off-axis factors provided information about the geometric arrangement of the beam segments but were not useful for distinguishing between plans that passed and failed QA. This study has provided some simple tests for plan accuracy, which may help minimise time spent on QA assessments of treatments that are unlikely to pass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the objectives of this study was to evaluate soil testing equipment based on its capability of measuring in-place stiffness or modulus values. As design criteria transition from empirical to mechanistic-empirical, soil test methods and equipment that measure properties such as stiffness and modulus and how they relate to Florida materials are needed. Requirements for the selected equipment are that they be portable, cost effective, reliable, a ccurate, and repeatable. A second objective is that the selected equipment measures soil properties without the use of nuclear materials.The current device used to measure soil compaction is the nuclear density gauge (NDG). Equipment evaluated in this research included lightweight deflectometers (LWD) from different manufacturers, a dynamic cone penetrometer (DCP), a GeoGauge, a Clegg impact soil tester (CIST), a Briaud compaction device (BCD), and a seismic pavement analyzer (SPA). Evaluations were conducted over ranges of measured densities and moistures.Testing (Phases I and II) was conducted in a test box and test pits. Phase III testing was conducted on materials found on five construction projects located in the Jacksonville, Florida, area. Phase I analyses determined that the GeoGauge had the lowest overall coefficient of variance (COV). In ascending order of COV were the accelerometer-type LWD, the geophone-type LWD, the DCP, the BCD, and the SPA which had the highest overall COV. As a result, the BCD and the SPA were excluded from Phase II testing.In Phase II, measurements obtained from the selected equipment were compared to the modulus values obtained by the static plate load test (PLT), the resilient modulus (MR) from laboratory testing, and the NDG measurements. To minimize soil and moisture content variability, the single spot testing sequence was developed. At each location, test results obtained from the portable equipment under evaluation were compared to the values from adjacent NDG, PLT, and laboratory MR measurements. Correlations were developed through statistical analysis. Target values were developed for various soils for verification on similar soils that were field tested in Phase III. The single spot testing sequence also was employed in Phase III, field testing performed on A-3 and A-2-4 embankments, limerock-stabilized subgrade, limerock base, and graded aggregate base found on Florida Department of Transportation construction projects. The Phase II and Phase III results provided potential trend information for future research—specifically, data collection for in-depth statistical analysis for correlations with the laboratory MR for specific soil types under specific moisture conditions. With the collection of enough data, stronger relationships could be expected between measurements from the portable equipment and the MR values. Based on the statistical analyses and the experience gained from extensive use of the equipment, the combination of the DCP and the LWD was selected for in-place soil testing for compaction control acceptance. Test methods and developmental specifications were written for the DCP and the LWD. The developmental specifications include target values for the compaction control of embankment, subgrade, and base materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The motivation for this study was to reduce physics workload relating to patient- specific quality assurance (QA). VMAT plan delivery accuracy was determined from analysis of pre- and on-treatment trajectory log files and phantom-based ionization chamber array measurements. The correlation in this combination of measurements for patient-specific QA was investigated. The relationship between delivery errors and plan complexity was investigated as a potential method to further reduce patient-specific QA workload. Thirty VMAT plans from three treatment sites - prostate only, prostate and pelvic node (PPN), and head and neck (H&N) - were retrospectively analyzed in this work. The 2D fluence delivery reconstructed from pretreatment and on-treatment trajectory log files was compared with the planned fluence using gamma analysis. Pretreatment dose delivery verification was also car- ried out using gamma analysis of ionization chamber array measurements compared with calculated doses. Pearson correlations were used to explore any relationship between trajectory log file (pretreatment and on-treatment) and ionization chamber array gamma results (pretreatment). Plan complexity was assessed using the MU/ arc and the modulation complexity score (MCS), with Pearson correlations used to examine any relationships between complexity metrics and plan delivery accu- racy. Trajectory log files were also used to further explore the accuracy of MLC and gantry positions. Pretreatment 1%/1 mm gamma passing rates for trajectory log file analysis were 99.1% (98.7%-99.2%), 99.3% (99.1%-99.5%), and 98.4% (97.3%-98.8%) (median (IQR)) for prostate, PPN, and H&N, respectively, and were significantly correlated to on-treatment trajectory log file gamma results (R = 0.989, p < 0.001). Pretreatment ionization chamber array (2%/2 mm) gamma results were also significantly correlated with on-treatment trajectory log file gamma results (R = 0.623, p < 0.001). Furthermore, all gamma results displayed a significant correlation with MCS (R > 0.57, p < 0.001), but not with MU/arc. Average MLC position and gantry angle errors were 0.001 ± 0.002 mm and 0.025° ± 0.008° over all treatment sites and were not found to affect delivery accuracy. However, vari- ability in MLC speed was found to be directly related to MLC position accuracy. The accuracy of VMAT plan delivery assessed using pretreatment trajectory log file fluence delivery and ionization chamber array measurements were strongly correlated with on-treatment trajectory log file fluence delivery. The strong corre- lation between trajectory log file and phantom-based gamma results demonstrates potential to reduce our current patient-specific QA. Additionally, insight into MLC and gantry position accuracy through trajectory log file analysis and the strong cor- relation between gamma analysis results and the MCS could also provide further methodologies to both optimize the VMAT planning and QA process. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Improving European education and training system quality has been set as a key target in Europe’s strategy to become a smart, sustainable and inclusive economy by 2020 (European Commission, 2010). These objectives are more specifically defined in the so called Modernisation Agenda (European Commission, 2011). More specifically it sets a goal to improve the quality and relevance of higher education. In this process external evaluation and
Proceedings of the 11th International CDIO Conference, Chengdu University of Information Technology,
Chengdu, Sichuan, P.R. China, June 8-11, 2015.
self-assessment are seen in a key role! In the CDIO approach the 12 CDIO standards provide a framework for continuous improvement. Each institution/institutional department are encouraged to regularly do the self-evaluation using the CDIO Standards. Eight European universities identified a need for further enhancement of the self-evaluations and creation of processes with peers to reduce the inertia of heavy accreditations/evaluations in HEIs. In September 2014 these universities started an Erasmus+ project (QAEMarketPlace4HEI) aiming at
1. Developing a collaborative, comprehensive and accessible evaluation process model, methods and tools for HEIs to complement the accreditation systems.
2. Promoting, increasing and exploiting further the European collaboration in the evaluation processes and the exchange of best practices.
3. Disseminating the model, best practices and widen the cooperation to new HEIs in Europe through the partner networks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The arid regions are dominated to a much larger degree than humid regions by major catastrophic events. Although most of Egypt lies within the great hot desert belt; it experiences especially in the north some torrential rainfall, which causes flash floods all over Sinai Peninsula. Flash floods in hot deserts are characterized by high velocity and low duration with a sharp discharge peak. Large sediment loads may be carried by floods threatening fields and settlements in the wadis and even people who are living there. The extreme spottiness of rare heavy rainfall, well known to desert people everywhere, precludes any efficient forecasting. Thus, although the limitation of data still reflects pre-satellite methods, chances of developing a warning system for floods in the desert seem remote. The relatively short flood-to-peak interval, a characteristic of desert floods, presents an additional impediment to the efficient use of warning systems. The present thesis contains introduction and five chapters, chapter one points out the physical settings of the study area. There are the geological settings such as outcrop lithology of the study area and the deposits. The alluvial deposits of Wadi Moreikh had been analyzed using OSL dating to know deposits and palaeoclimatic conditions. The chapter points out as well the stratigraphy and the structure geology containing main faults and folds. In addition, it manifests the pesent climate conditions such as temperature, humidity, wind and evaporation. Besides, it presents type of soils and natural vegetation cover of the study area using unsupervised classification for ETM+ images. Chapter two points out the morphometric analysis of the main basins and their drainage network in the study area. It is divided into three parts: The first part manifests the morphometric analysis of the drainage networks which had been extracted from two main sources, topographic maps and DEM images. Basins and drainage networks are considered as major influencing factors on the flash floods; Most of elements were studied which affect the network such as stream order, bifurcation ratio, stream lengths, stream frequency, drainage density, and drainage patterns. The second part of this chapter shows the morphometric analysis of basins such as area, dimensions, shape and surface. Whereas, the third part points the morphometric analysis of alluvial fans which form most of El-Qaá plain. Chapter three manifests the surface runoff through rainfall and losses analysis. The main subject in this chapter is rainfall which has been studied in detail; it is the main reason for runoff. Therefore, all rainfall characteristics are regarded here such as rainfall types, distribution, rainfall intensity, duration, frequency, and the relationship between rainfall and runoff. While the second part of this chapter concerns with water losses estimation by evaporation and infiltration which are together the main losses with direct effect on the high of runoff. Finally, chapter three points out the factors influencing desert runoff and runoff generation mechanism. Chapter four is concerned with assessment of flood hazard, it is important to estimate runoff and tocreate a map of affected areas. Therefore, the chapter consists of four main parts; first part manifests the runoff estimation, the different methods to estimate runoff and its variables such as runoff coefficient lag time, time of concentration, runoff volume, and frequency analysis of flash flood. While the second part points out the extreme event analysis. The third part shows the map of affected areas for every basin and the flash floods degrees. In this point, it has been depending on the DEM to extract the drainage networks and to determine the main streams which are normally more dangerous than others. Finally, part four presets the risk zone map of total study area which is of high inerest for planning activities. Chapter five as the last chapter concerns with flash flood Hazard mitigation. It consists of three main parts. First flood prediction and the method which can be used to predict and forecast the flood. The second part aims to determine the best methods which can be helpful to mitigate flood hazard in the arid zone and especially the study area. Whereas, the third part points out the development perspective for the study area indicating the suitable places in El-Qaá plain for using in economic activities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adjuvant chemotherapy decisions in breast cancer are increasingly based on the pathologist's assessment of tumor proliferation. The Swiss Working Group of Gyneco- and Breast Pathologists has surveyed inter- and intraobserver consistency of Ki-67-based proliferative fraction in breast carcinomas. Methods Five pathologists evaluated MIB-1-labeling index (LI) in ten breast carcinomas (G1, G2, G3) by counting and eyeballing. In the same way, 15 pathologists all over Switzerland then assessed MIB-1-LI on three G2 carcinomas, in self-selected or pre-defined areas of the tumors, comparing centrally immunostained slides with slides immunostained in the different laboratoires. To study intra-observer variability, the same tumors were re-examined 4 months later. Results The Kappa values for the first series of ten carcinomas of various degrees of differentiation showed good to very good agreement for MIB-1-LI (Kappa 0.56–0.72). However, we found very high inter-observer variabilities (Kappa 0.04–0.14) in the read-outs of the G2 carcinomas. It was not possible to explain the inconsistencies exclusively by any of the following factors: (i) pathologists' divergent definitions of what counts as a positive nucleus (ii) the mode of assessment (counting vs. eyeballing), (iii) immunostaining technique, and (iv) the selection of the tumor area in which to count. Despite intensive confrontation of all participating pathologists with the problem, inter-observer agreement did not improve when the same slides were re-examined 4 months later (Kappa 0.01–0.04) and intra-observer agreement was likewise poor (Kappa 0.00–0.35). Conclusion Assessment of mid-range Ki-67-LI suffers from high inter- and intra-observer variability. Oncologists should be aware of this caveat when using Ki-67-LI as a basis for treatment decisions in moderately differentiated breast carcinomas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Traditional patient-specific IMRT QA measurements are labor intensive and consume machine time. Calculation-based IMRT QA methods typically are not comprehensive. We have developed a comprehensive calculation-based IMRT QA method to detect uncertainties introduced by the initial dose calculation, the data transfer through the Record-and-Verify (R&V) system, and various aspects of the physical delivery. Methods: We recomputed the treatment plans in the patient geometry for 48 cases using data from the R&V, and from the delivery unit to calculate the “as-transferred” and “as-delivered” doses respectively. These data were sent to the original TPS to verify transfer and delivery or to a second TPS to verify the original calculation. For each dataset we examined the dose computed from the R&V record (RV) and from the delivery records (Tx), and the dose computed with a second verification TPS (vTPS). Each verification dose was compared to the clinical dose distribution using 3D gamma analysis and by comparison of mean dose and ROI-specific dose levels to target volumes. Plans were also compared to IMRT QA absolute and relative dose measurements. Results: The average 3D gamma passing percentages using 3%-3mm, 2%-2mm, and 1%-1mm criteria for the RV plan were 100.0 (σ=0.0), 100.0 (σ=0.0), and 100.0 (σ=0.1); for the Tx plan they were 100.0 (σ=0.0), 100.0 (σ=0.0), and 99.0 (σ=1.4); and for the vTPS plan they were 99.3 (σ=0.6), 97.2 (σ=1.5), and 79.0 (σ=8.6). When comparing target volume doses in the RV, Tx, and vTPS plans to the clinical plans, the average ratios of ROI mean doses were 0.999 (σ=0.001), 1.001 (σ=0.002), and 0.990 (σ=0.009) and ROI-specific dose levels were 0.999 (σ=0.001), 1.001 (σ=0.002), and 0.980 (σ=0.043), respectively. Comparing the clinical, RV, TR, and vTPS calculated doses to the IMRT QA measurements for all 48 patients, the average ratios for absolute doses were 0.999 (σ=0.013), 0.998 (σ=0.013), 0.999 σ=0.015), and 0.990 (σ=0.012), respectively, and the average 2D gamma(5%-3mm) passing percentages for relative doses for 9 patients was were 99.36 (σ=0.68), 99.50 (σ=0.49), 99.13 (σ=0.84), and 98.76 (σ=1.66), respectively. Conclusions: Together with mechanical and dosimetric QA, our calculation-based IMRT QA method promises to minimize the need for patient-specific QA measurements by identifying outliers in need of further review.