990 resultados para Pulse Amplitude Modulation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Notes on AM, DSBSC, QAM, BPSK, 4QAM, 8PSK, 16QAM

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Spectrally modulated Airy-based pulses peak amplitude modulation (PAM) in linear dispersive media is investigated, designed, and numerically simulated. As it is shown here, it is possible to design the spectral modulation of the initial Airy-based pulses to obtain a pre-defined PAM profile as the pulse propagates. Although optical pulses self-amplitude modulation is a well-known effect under non-linear propagation, the designed Airy-based pulses exhibit PAM under linear dispersive propagation. This extraordinary linear propagation property can be applied in many kinds of dispersive media, enabling its use in a broad range of experiments and applications. © 2013 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Au cours des dernières années, la photonique intégrée sur silicium a progressé rapidement. Les modulateurs issus de cette technologie présentent des caractéristiques potentiellement intéressantes pour les systèmes de communication à courte portée. En effet, il est prévu que ces modulateurs pourront être opérés à des vitesses de transmission élevées, tout en limitant le coût de fabrication et la consommation de puissance. Parallèlement, la modulation d’amplitude multi-niveau (PAM) est prometteuse pour ce type de systèmes. Ainsi, ce travail porte sur le développement de modulateurs de silicium pour la transmission de signaux PAM. Dans le premier chapitre, les concepts théoriques nécessaires à la conception de modulateurs de silicium sont présentés. Les modulateurs Mach-Zehnder et les modulateurs à base de réseau de Bragg sont principalement abordés. De plus, les effets électro-optiques dans le silicium, la modulation PAM, les différents types d’électrodes intégrées et la compensation des distorsions par traitement du signal sont détaillés.Dans le deuxième chapitre, un modulateur Mach-Zehnder aux électrodes segmentées est présenté. La segmentation des électrodes permet la génération de signaux optiques PAM à partir de séquences binaires. Cette approche permet d’éliminer l’utilisation de convertisseur numérique-analogique en intégrant cette fonction dans le domaine optique, ce qui vise à réduire le coût du système de communication. Ce chapitre contient la description détaillée du modulateur, les résultats de caractérisation optique et de la caractérisation électrique, ainsi que les tests systèmes. De plus, les tests systèmes incluent l’utilisation de pré-compensation ou de post-compensation du signal sous la forme d’égalisation de la réponse en fréquence pour les formats de modulation PAM-4 et PAM-8 à différents taux binaires. Une vitesse de transmission de 30 Gb/s est démontrée dans les deux cas et ce malgré une limitation importante de la réponse en fréquence suite à l’ajout d’un assemblage des circuits radiofréquences (largeur de bande 3 dB de 8 GHz). Il s’agit de la première démonstration de modulation PAM-8 à l’aide d’un modulateur Mach-Zehnder aux électrodes segmentées. Finalement, les conclusions tirées de ce travail ont mené à la conception d’un deuxième modulateur Mach-Zehnder aux électrodes segmentées présentement en phase de test, dont les performances montrent un très grand potentiel. Dans le troisième chapitre, un modulateur à réseau de Bragg à deux sauts de phase est présenté. L’utilisation de réseaux de Bragg est une approche encore peu développée pour la modulation. En effet, la réponse spectrale de ces structures peut être contrôlée précisément, une caractéristique intéressante pour la conception de modulateurs. Dans ces travaux, nous proposons l’ajout de deux sauts de phase à un réseau de Bragg uniforme pour obtenir un pic de transmission dans la bande de réflexion de celui-ci. Ainsi, il est possible d’altérer l’amplitude du pic de transmission à l’aide d’une jonction pn. Comme pour le deuxième chapitre, ce chapitre inclut la description détaillée du modulateur, les résultats des caractérisations optique et électrique, ainsi que les tests systèmes. De plus, la caractérisation de jonctions pn à l’aide du modulateur à réseau de Bragg est expliquée. Des vitesses de transmission PAM-4 de 60 Gb/s et OOK de 55 Gb/s sont démontrées après la compensation des distorsions des signaux. À notre connaissance, il s’agit du modulateur à réseau de Bragg le plus rapide à ce jour. De plus, pour la première fois, les performances d’un tel modulateur s’approchent de celles des modulateurs de silicium les plus rapides utilisant des microrésonateurs en anneau ou des interféromètres Mach-Zehnder.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To determine the correlation between ocular blood flow velocities and ocular pulse amplitude (OPA) in glaucoma patients using colour Doppler imaging (CDI) waveform analysis. METHOD: A prospective, observer-masked, case-control study was performed. OPA and blood flow variables from central retinal artery and vein (CRA, CRV), nasal and temporal short posterior ciliary arteries (NPCA, TPCA) and ophthalmic artery (OA) were obtained through dynamic contour tonometry and CDI, respectively. Univariate and multiple regression analyses were performed to explore the correlations between OPA and retrobulbar CDI waveform and systemic cardiovascular parameters (blood pressure, blood pressure amplitude, mean ocular perfusion pressure and peripheral pulse). RESULTS: One hundred and ninety-two patients were included [healthy controls: 55; primary open-angle glaucoma (POAG): 74; normal-tension glaucoma (NTG): 63]. OPA was statistically different between groups (Healthy: 3.17 ± 1.2 mmHg; NTG: 2.58 ± 1.2 mmHg; POAG: 2.60 ± 1.1 mmHg; p < 0.01), but not between the glaucoma groups (p = 0.60). Multiple regression models to explain OPA variance were made for each cohort (healthy: p < 0.001, r = 0.605; NTG: p = 0.003, r = 0.372; POAG: p < 0.001, r = 0.412). OPA was independently associated with retrobulbar CDI parameters in the healthy subjects and POAG patients (healthy CRV resistance index: β = 3.37, CI: 0.16-6.59; healthy NPCA mean systolic/diastolic velocity ratio: β = 1.34, CI: 0.52-2.15; POAG TPCA mean systolic velocity: β = 0.14, CI 0.05-0.23). OPA in the NTG group was associated with diastolic blood pressure and pulse rate (β = -0.04, CI: -0.06 to -0.01; β = -0.04, CI: -0.06 to -0.001, respectively). CONCLUSIONS: Vascular-related models provide a better explanation to OPA variance in healthy individuals than in glaucoma patients. The variables that influence OPA seem to be different in healthy, POAG and NTG patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Considers Sampling, Pulse Amplitude Modulation, Multiple Access, Quantisation, Pulse Coded Modulation, Manchester Line Coding, Amplitude Modulation, Double SideBand Suppressed Carrier Modulation, Quadrature Amplitude Modulation and M-ary Shift Keying.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Metal pollution in rivers is in great concern with human activities in the fluvial watershed. This thesis aims to investigate the potential use of chl-a fluorescence parameters as biomarkers of metal toxicity, and to find cause-effect relationships between metal exposures, other environmental factor (i.e. light), and functional and structural biofilm responses. This thesis demonstrates that the use of chl-a fluorescence parameters allows detect early effects on biofilms caused by zinc toxicity, both in the laboratory as in polluted rivers. In microcosm experiments, the use of chl-a fluorescence parameters allows evaluates structural changes on photosynthetic apparatus and in algal groups’ composition of biofilms long-term exposed to zinc. In order to evaluate the effects of chronic metal pollution in rivers, it is recommended the use of biofilm translocation experiments and the use of a multi-biomarker approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple constant-current electrocutaneous stimulator for high-impedance loads using low-cost, standard high-voltage components is presented. A voltage-regulator powers an oscillator built across the primary of a transformer whose secondary delivers, after rectification, the high-voltage supply to switched current-mirrors in the driving stage. Since the compliance high-voltage is proportional to the stimulation current, overall power consumption is minimized. By adjusting the regulated voltage, control of the pulsed-current amplitude is achieved. A prototype with readily available components features stimulation currents of amplitude and pulsewidth in the range 0≤Iskin≤20mA and 50μs ≤Tpulse≤1ms, respectively. Pulse-repetition spans from 1 Hz to 10Hz. Worst-case ripple is 3.7% @Iskin=1mA. Measured pulse fall-time is shorter than 32μs. Overall consumption is 4.4W @Iskin=20mA. Subject isolation from line is 4KV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent experimental evidence has suggested a neuromodulatory deficit in Alzheimer's disease (AD). In this paper, we present a new electroencephalogram (EEG) based metric to quantitatively characterize neuromodulatory activity. More specifically, the short-term EEG amplitude modulation rate-of-change (i.e., modulation frequency) is computed for five EEG subband signals. To test the performance of the proposed metric, a classification task was performed on a database of 32 participants partitioned into three groups of approximately equal size: healthy controls, patients diagnosed with mild AD, and those with moderate-to-severe AD. To gauge the benefits of the proposed metric, performance results were compared with those obtained using EEG spectral peak parameters which were recently shown to outperform other conventional EEG measures. Using a simple feature selection algorithm based on area-under-the-curve maximization and a support vector machine classifier, the proposed parameters resulted in accuracy gains, relative to spectral peak parameters, of 21.3% when discriminating between the three groups and by 50% when mild and moderate-to-severe groups were merged into one. The preliminary findings reported herein provide promising insights that automated tools may be developed to assist physicians in very early diagnosis of AD as well as provide researchers with a tool to automatically characterize cross-frequency interactions and their changes with disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During short-term postural changes, the factors determining the amplitude of intracranial pulse pressure (ICPPA) remain constant, except for cerebrovascular resistance (CVR). Therefore, it may be possible to draw conclusions from the ICPPA onto the cerebrovascular resistance (CVR) and thus the relative change in cerebral perfusion pressure (CPP).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To investigate changes in ocular pulse amplitude (OPA) during a short-term increase in intraocular pressure (IOP) and to assess possible influences of biometrical properties of the eye, including central corneal thickness (CCT) and axial length.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To test whether dynamic contour tonometry yields ocular pulse amplitude (OPA) measurements that are independent of corneal thickness and curvature, and to assess variables of observer agreement. METHODS: In a multivariate cluster analysis on 223 eyes, the relationship between central corneal thickness, corneal curvature, axial length, anterior chamber depth, intraocular pressure, sex, age, and OPA measurements was assessed. Intraobserver and interobserver variabilities were calculated from repeated measurements obtained from 8 volunteers by 4 observers. RESULTS: The OPA readings were not affected by central corneal thickness (P = .08), corneal curvature (P = .47), anterior chamber depth (P = .80), age (P = .60), or sex (P = .73). There was a positive correlation between OPA and intraocular pressure (0.12 mm Hg/1 mm Hg of intraocular pressure; P<.001) and a negative correlation between OPA and axial length (0.27 mm Hg/1 mm of length; P<.001). Intraobserver and interobserver variabilities were 0.08 and 0.02 mm Hg, respectively, and the intraclass correlation coefficient was 0.89. CONCLUSIONS: The OPA readings obtained with dynamic contour tonometry in healthy subjects are not influenced by the structure of the anterior segment of the eye but are affected by intraocular pressure and axial length. We found a high amount of agreement within and between observers.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mathematical underpinning of the pulse width modulation (PWM) technique lies in the attempt to represent “accurately” harmonic waveforms using only square forms of a fixed height. The accuracy can be measured using many norms, but the quality of the approximation of the analog signal (a harmonic form) by a digital one (simple pulses of a fixed high voltage level) requires the elimination of high order harmonics in the error term. The most important practical problem is in “accurate” reproduction of sine-wave using the same number of pulses as the number of high harmonics eliminated. We describe in this paper a complete solution of the PWM problem using Padé approximations, orthogonal polynomials, and solitons. The main result of the paper is the characterization of discrete pulses answering the general PWM problem in terms of the manifold of all rational solutions to Korteweg-de Vries equations.