989 resultados para Pulmonary artery catheter knot formation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A particular event concerning a Swan-Ganz catheter complication is reported. A 41-year-old woman was admitted at the emergency room of our hospital with massive gastrointestinal bleeding. A total gastrectomy was performed. During the postoperative period in the intensive care unit , the patient maintained hemodynamic instability. Invasive hemodynamic monitoring with a pulmonary artery catheter was then indicated. During the maneuvers to insert the catheter, a true knot formation was identified at the level of the superior vena cava. Several maneuvers by radiological endovascular invasive techniques allowed removal of the catheter. The authors describe the details of this procedure and provide comments regarding the various techniques that were employed in overcoming this event. A comprehensive review of evidence regarding the benefits and risks of pulmonary artery catheterization was performed. The consensus statement regarding the indications, utilization, and management of the pulmonary artery catheterization that were issued by a consensus conference held in 1996 are also discussed in detail.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The pulmonary artery catheter (PAC) is a powerful tool that has been used extensively in the assessment and monitoring of cardiovascular physiology. Gross misinterpretation of data gathered by the PAC is common, and its routine use without any specific interventions has not been shown to influence outcome. However, there currently is no evidence from randomized, controlled trials that any diagnostic or monitoring tool used in intensive care patients improves outcome. Studies evaluating the use of the PAC have included numerous potential confounding factors, and should be interpreted with caution. The information obtained with the PAC should be used to find better treatment strategies, and these strategies, instead of the tool itself, should be tested in clinical trials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To clarify the role of the pulmonary artery catheter in the intensive care unit. DATA SOURCES: Recent and relevant literature from MEDLINE and authors' personal databases. STUDY SELECTION: Studies on pulmonary artery catheter use and use of other monitoring devices in critically ill patients. DATA EXTRACTION: Based largely on clinical experience and assessment of the relevant published literature and in response to recent articles attacking the pulmonary artery catheter, we propose that the pulmonary artery catheter is still a valuable tool for the hemodynamic monitoring of patients with complex disease processes in whom the information obtained from the pulmonary artery catheter may influence management. We suggest that there is a need to revisit the basics of hemodynamic management and reassess the way in which the pulmonary artery catheter is used, applying three key principles: correct measurement, correct data interpretation, and correct application. CONCLUSION: The pulmonary artery catheter is still a valuable tool for hemodynamic monitoring when used in selected patients and by physicians adequately trained to correctly interpret and apply the data provided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This case report describes removal of a knotted, subclavian, pulmonary artery catheter using a tracheostomy dilator. With this simple method an invasive procedure might be averted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In 2003 there was an increase in the use of pulmonary artery catheters in Australia from 12, 000 to 16, 000 units in intensive care and peri-operative care. This survey of intensive care nurses in five intensive care units in Queensland addressed knowledge of use, safety and complications of the pulmonary artery catheter, using a previously validated 31 question multiple choice survey. One hundred and thirty-nine questionnaires were completed, a response rate of 46%. The mean score was 13.3, standard deviation +/-4.2 out of a total of 31 (42.8% correct). The range was 4 to 25. Scores were significantly higher in those participants with more ICU experience, higher nursing grade, a higher self-assessed level of knowledge and greater frequency of PAC supervision. There was no significant correlation between total score and hospital- or university-based education, or total score and public or private hospital participants. Fifty-one per cent were unable to correctly identify the significant pressure change as the catheter is advanced from the right ventricle to the pulmonary artery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In spontaneously breathing cardiac patients, pulmonary artery pressure (PAP) can be accurately estimated from the transthoracic Doppler study of pulmonary artery and tricuspid regurgitation blood flows. In critically ill patients on mechanical ventilation for acute lung injury, the interposition of gas between the probe and the heart renders the transthoracic approach problematic. This study was aimed at determining whether the transesophageal approach could offer an alternative. METHODS: Fifty-one consecutive sedated and ventilated patients with severe hypoxemia (arterial oxygen tension/fraction of inspired oxygen < 300) were prospectively studied. Mean PAP measured from the pulmonary artery catheter was compared with several indices characterizing pulmonary artery blood flow assessed using transesophageal echocardiography: preejection time, acceleration time, ejection duration, preejection time on ejection duration ratio, and acceleration time on ejection duration ratio. In a subgroup of 20 patients, systolic PAP measured from the pulmonary artery catheter immediately before withdrawal was compared with Doppler study of regurgitation tricuspid flow performed immediately after pulmonary artery catheter withdrawal using either the transthoracic or the transesophageal approach. RESULTS: Weak and clinically irrelevant correlations were found between mean PAP and indices of pulmonary artery flow. A statistically significant and clinically relevant correlation was found between systolic PAP and regurgitation tricuspid flow. In 3 patients (14%), pulmonary artery pressure could not be assessed echocardiographically. CONCLUSIONS: In hypoxemic patients on mechanical ventilation, mean PAP cannot be reliably estimated from indices characterizing pulmonary artery blood flow. Systolic PAP can be estimated from regurgitation tricuspid flow using either transthoracic or transesophageal approach. © 2008 American Society of Anesthesiologists, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Physiological data obtained with the pulmonary artery catheter (PAC) are susceptible to errors in measurement and interpretation. Little attention has been paid to the relevance of errors in hemodynamic measurements performed in the intensive care unit (ICU). The aim of this study was to assess the errors related to the technical aspects (zeroing and reference level) and actual measurement (curve interpretation) of the pulmonary artery occlusion pressure (PAOP). METHODS: Forty-seven participants in a special ICU training program and 22 ICU nurses were tested without pre-announcement. All participants had previously been exposed to the clinical use of the method. The first task was to set up a pressure measurement system for PAC (zeroing and reference level) and the second to measure the PAOP. RESULTS: The median difference from the reference mid-axillary zero level was - 3 cm (-8 to + 9 cm) for physicians and -1 cm (-5 to + 1 cm) for nurses. The median difference from the reference PAOP was 0 mmHg (-3 to 5 mmHg) for physicians and 1 mmHg (-1 to 15 mmHg) for nurses. When PAOP values were adjusted for the differences from the reference transducer level, the median differences from the reference PAOP values were 2 mmHg (-6 to 9 mmHg) for physicians and 2 mmHg (-6 to 16 mmHg) for nurses. CONCLUSIONS: Measurement of the PAOP is susceptible to substantial error as a result of practical mistakes. Comparison of results between ICUs or practitioners is therefore not possible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Catheter-induced pulmonary artery rupture is an infrequent complication that may occur during invasive cardiopulmonary monitoring. Fatal cases are uncommon and result from hemoptysis and flooding of the opposite lung with resulting hypoyxia. Alpha-1-antitrypsin deficiency is a rare genetic disorder characterised by low serum levels of alpha-1-antitrypsin, critical in maintaining connective tissue integrity. Besides pulmonary emphysema, recent observations suggest that alpha-1-antitrypsin deficiency may also be involved in vascular wall weakening, thereby predisposing arteries to dissection and aneurysm formation. In this article, we describe an autopsy case of pulmonary artery iatrogenic rupture due to insertion of a Swan-Ganz catheter in an 82-year-old woman suffering from pulmonary hypertension and alpha-1-antitrypsin deficiency. The exact source of bleeding could not be precisely identified during autopsy due to the extent of tissue hemorrhage, though postmortem angiography revealed a contrast medium extravasation from a branch of the left pulmonary lower lobar artery. The case herein emphasises the importance of postmortem angiography in facilitating the detection of vascular injuries, the importance of familiarity with intensive care techniques and procedures on behalf of forensic pathologists as well as in-depth knowledge of all possible contributing conditions and predisposing disorders in the pathogenesis of death.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the case of a patient in whom successful radiofrequency catheter ablation of an idiopathic ventricular tachycardia (VT) originating in the main stem of the pulmonary artery was performed. After successful ablation of the index arrhythmia, which was an idiopathic right ventricular outflow tract VT, a second VT with a different QRS morphology was reproducibly induced. Mapping of the second VT revealed the presence of myocardium approximately 2 cm above the pulmonary valve. Application of radiofrequency energy at this site resulted in termination and noninducibility of this VT. After 6-month follow-up, the patient remained free from VT recurrences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to investigate whether β-adrenoceptor (β-AR) overstimulation induced by in vivo treatment with isoproterenol (ISO) alters vascular reactivity and nitric oxide (NO) production and signaling in pulmonary arteries. Vehicle or ISO (0.3mgkg(-1)day(-1)) was administered daily to male Wistar rats. After 7days, the jugular vein was cannulated to assess right ventricular (RV) systolic pressure (SP) and end diastolic pressure (EDP). The extralobar pulmonary arteries were isolated to evaluate the relaxation responses, protein expression (Western blot), NO production (diaminofluorescein-2 fluorescence), and cyclic guanosine 3',5'-monophosphate (cGMP) levels (enzyme immunoassay kit). ISO treatment induced RV hypertrophy; however, no differences in RV-SP and EDP were observed. The pulmonary arteries from the ISO-treated group showed enhanced relaxation to acetylcholine that was abolished by the NO synthase (NOS) inhibitor N(ω)-nitro-l-arginine methyl ester (l-NAME); whereas relaxation elicited by sodium nitroprusside, ISO, metaproterenol, mirabegron, or KCl was not affected by ISO treatment. ISO-treated rats displayed enhanced endothelial NOS (eNOS) and vasodilator-stimulated phosphoprotein (VASP) expression in the pulmonary arteries, while phosphodiesterase-5 protein expression decreased. ISO treatment increased NO and cGMP levels and did not induce eNOS uncoupling. The present data indicate that β-AR overactivation enhances the endothelium-dependent relaxation of pulmonary arteries. This effect was linked to an increase in eNOS-derived NO production, cGMP formation and VASP content and to a decrease in phosphodiesterase-5 expression. Therefore, elevated NO bioactivity through cGMP/VASP signaling could represent a protective mechanism of β-AR overactivation on pulmonary circulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 50-year-old man developed recurrent angina 1 year after coronary artery bypass surgery. The patient was found to have a large fistula involving branches of the internal mammary artery graft and the left pulmonary artery. In the absence of another clear cause for the patient's symptoms, we speculated that our patient's angina and abnormal stress nuclear study were due to coronary steal. In patients with a history of coronary bypass grafting, fistula formation between graft and native vessels should be considered as a possible cause of early recurrent angina.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Congenital diaphragmatic hernia (CDH) is associated with pulmonary hypertension which is often difficult to manage, and a significant cause of morbidity and mortality. In this study, we have used a rabbit model of CDH to evaluate the effects of BAY 60-2770 on the in vitro reactivity of left pulmonary artery. CDH was performed in New Zealand rabbit fetuses (n = 10 per group) and compared to controls. Measurements of body, total and left lung weights (BW, TLW, LLW) were done. Pulmonary artery rings were pre-contracted with phenylephrine (10 μM), after which cumulative concentration-response curves to glyceryl trinitrate (GTN; NO donor), tadalafil (PDE5 inhibitor) and BAY 60-2770 (sGC activator) were obtained as well as the levels of NO (NO3/NO2). LLW, TLW and LBR were decreased in CDH (p < 0.05). In left pulmonary artery, the potency (pEC50) for GTN was markedly lower in CDH (8.25 ± 0.02 versus 9.27 ± 0.03; p < 0.01). In contrast, the potency for BAY 60-2770 was markedly greater in CDH (11.7 ± 0.03 versus 10.5 ± 0.06; p < 0.01). The NO2/NO3 levels were 62 % higher in CDH (p < 0.05). BAY 60-2770 exhibits a greater potency to relax the pulmonary artery in CDH, indicating a potential use for pulmonary hypertension in this disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulmonary artery sarcoma is a rare and highly lethal disease whose clinical findings are often indistinguishable from those of chronic thromboembolic pulmonary hypertension. Partial improvement after thrombolytic therapy has suggested that thromboembolic phenomena may be superimposed on the tumor, but, to date, a well-documented statement of these events has not been provided. (C) 2007 Elsevier GmbH. All rights reserved.