909 resultados para Pulmonary Artery Catheter
Resumo:
Background The accurate measurement of Cardiac output (CO) is vital in guiding the treatment of critically ill patients. Invasive or minimally invasive measurement of CO is not without inherent risks to the patient. Skilled Intensive Care Unit (ICU) nursing staff are in an ideal position to assess changes in CO following therapeutic measures. The USCOM (Ultrasonic Cardiac Output Monitor) device is a non-invasive CO monitor whose clinical utility and ease of use requires testing. Objectives To compare cardiac output measurement using a non-invasive ultrasonic device (USCOM) operated by a non-echocardiograhically trained ICU Registered Nurse (RN), with the conventional pulmonary artery catheter (PAC) using both thermodilution and Fick methods. Design Prospective observational study. Setting and participants Between April 2006 and March 2007, we evaluated 30 spontaneously breathing patients requiring PAC for assessment of heart failure and/or pulmonary hypertension at a tertiary level cardiothoracic hospital. Methods SCOM CO was compared with thermodilution measurements via PAC and CO estimated using a modified Fick equation. This catheter was inserted by a medical officer, and all USCOM measurements by a senior ICU nurse. Mean values, bias and precision, and mean percentage difference between measures were determined to compare methods. The Intra-Class Correlation statistic was also used to assess agreement. The USCOM time to measure was recorded to assess the learning curve for USCOM use performed by an ICU RN and a line of best fit demonstrated to describe the operator learning curve. Results In 24 of 30 (80%) patients studied, CO measures were obtained. In 6 of 30 (20%) patients, an adequate USCOM signal was not achieved. The mean difference (±standard deviation) between USCOM and PAC, USCOM and Fick, and Fick and PAC CO were small, −0.34 ± 0.52 L/min, −0.33 ± 0.90 L/min and −0.25 ± 0.63 L/min respectively across a range of outputs from 2.6 L/min to 7.2 L/min. The percent limits of agreement (LOA) for all measures were −34.6% to 17.8% for USCOM and PAC, −49.8% to 34.1% for USCOM and Fick and −36.4% to 23.7% for PAC and Fick. Signal acquisition time reduced on average by 0.6 min per measure to less than 10 min at the end of the study. Conclusions In 80% of our cohort, USCOM, PAC and Fick measures of CO all showed clinically acceptable agreement and the learning curve for operation of the non-invasive USCOM device by an ICU RN was found to be satisfactorily short. Further work is required in patients receiving positive pressure ventilation.
Resumo:
The pulmonary artery catheter (PAC) is a powerful tool that has been used extensively in the assessment and monitoring of cardiovascular physiology. Gross misinterpretation of data gathered by the PAC is common, and its routine use without any specific interventions has not been shown to influence outcome. However, there currently is no evidence from randomized, controlled trials that any diagnostic or monitoring tool used in intensive care patients improves outcome. Studies evaluating the use of the PAC have included numerous potential confounding factors, and should be interpreted with caution. The information obtained with the PAC should be used to find better treatment strategies, and these strategies, instead of the tool itself, should be tested in clinical trials.
Resumo:
OBJECTIVE: To clarify the role of the pulmonary artery catheter in the intensive care unit. DATA SOURCES: Recent and relevant literature from MEDLINE and authors' personal databases. STUDY SELECTION: Studies on pulmonary artery catheter use and use of other monitoring devices in critically ill patients. DATA EXTRACTION: Based largely on clinical experience and assessment of the relevant published literature and in response to recent articles attacking the pulmonary artery catheter, we propose that the pulmonary artery catheter is still a valuable tool for the hemodynamic monitoring of patients with complex disease processes in whom the information obtained from the pulmonary artery catheter may influence management. We suggest that there is a need to revisit the basics of hemodynamic management and reassess the way in which the pulmonary artery catheter is used, applying three key principles: correct measurement, correct data interpretation, and correct application. CONCLUSION: The pulmonary artery catheter is still a valuable tool for hemodynamic monitoring when used in selected patients and by physicians adequately trained to correctly interpret and apply the data provided.
Resumo:
This case report describes removal of a knotted, subclavian, pulmonary artery catheter using a tracheostomy dilator. With this simple method an invasive procedure might be averted.
Resumo:
In 2003 there was an increase in the use of pulmonary artery catheters in Australia from 12, 000 to 16, 000 units in intensive care and peri-operative care. This survey of intensive care nurses in five intensive care units in Queensland addressed knowledge of use, safety and complications of the pulmonary artery catheter, using a previously validated 31 question multiple choice survey. One hundred and thirty-nine questionnaires were completed, a response rate of 46%. The mean score was 13.3, standard deviation +/-4.2 out of a total of 31 (42.8% correct). The range was 4 to 25. Scores were significantly higher in those participants with more ICU experience, higher nursing grade, a higher self-assessed level of knowledge and greater frequency of PAC supervision. There was no significant correlation between total score and hospital- or university-based education, or total score and public or private hospital participants. Fifty-one per cent were unable to correctly identify the significant pressure change as the catheter is advanced from the right ventricle to the pulmonary artery.
Resumo:
BACKGROUND: In spontaneously breathing cardiac patients, pulmonary artery pressure (PAP) can be accurately estimated from the transthoracic Doppler study of pulmonary artery and tricuspid regurgitation blood flows. In critically ill patients on mechanical ventilation for acute lung injury, the interposition of gas between the probe and the heart renders the transthoracic approach problematic. This study was aimed at determining whether the transesophageal approach could offer an alternative. METHODS: Fifty-one consecutive sedated and ventilated patients with severe hypoxemia (arterial oxygen tension/fraction of inspired oxygen < 300) were prospectively studied. Mean PAP measured from the pulmonary artery catheter was compared with several indices characterizing pulmonary artery blood flow assessed using transesophageal echocardiography: preejection time, acceleration time, ejection duration, preejection time on ejection duration ratio, and acceleration time on ejection duration ratio. In a subgroup of 20 patients, systolic PAP measured from the pulmonary artery catheter immediately before withdrawal was compared with Doppler study of regurgitation tricuspid flow performed immediately after pulmonary artery catheter withdrawal using either the transthoracic or the transesophageal approach. RESULTS: Weak and clinically irrelevant correlations were found between mean PAP and indices of pulmonary artery flow. A statistically significant and clinically relevant correlation was found between systolic PAP and regurgitation tricuspid flow. In 3 patients (14%), pulmonary artery pressure could not be assessed echocardiographically. CONCLUSIONS: In hypoxemic patients on mechanical ventilation, mean PAP cannot be reliably estimated from indices characterizing pulmonary artery blood flow. Systolic PAP can be estimated from regurgitation tricuspid flow using either transthoracic or transesophageal approach. © 2008 American Society of Anesthesiologists, Inc.
Resumo:
BACKGROUND: Physiological data obtained with the pulmonary artery catheter (PAC) are susceptible to errors in measurement and interpretation. Little attention has been paid to the relevance of errors in hemodynamic measurements performed in the intensive care unit (ICU). The aim of this study was to assess the errors related to the technical aspects (zeroing and reference level) and actual measurement (curve interpretation) of the pulmonary artery occlusion pressure (PAOP). METHODS: Forty-seven participants in a special ICU training program and 22 ICU nurses were tested without pre-announcement. All participants had previously been exposed to the clinical use of the method. The first task was to set up a pressure measurement system for PAC (zeroing and reference level) and the second to measure the PAOP. RESULTS: The median difference from the reference mid-axillary zero level was - 3 cm (-8 to + 9 cm) for physicians and -1 cm (-5 to + 1 cm) for nurses. The median difference from the reference PAOP was 0 mmHg (-3 to 5 mmHg) for physicians and 1 mmHg (-1 to 15 mmHg) for nurses. When PAOP values were adjusted for the differences from the reference transducer level, the median differences from the reference PAOP values were 2 mmHg (-6 to 9 mmHg) for physicians and 2 mmHg (-6 to 16 mmHg) for nurses. CONCLUSIONS: Measurement of the PAOP is susceptible to substantial error as a result of practical mistakes. Comparison of results between ICUs or practitioners is therefore not possible.
Resumo:
We report the case of a patient in whom successful radiofrequency catheter ablation of an idiopathic ventricular tachycardia (VT) originating in the main stem of the pulmonary artery was performed. After successful ablation of the index arrhythmia, which was an idiopathic right ventricular outflow tract VT, a second VT with a different QRS morphology was reproducibly induced. Mapping of the second VT revealed the presence of myocardium approximately 2 cm above the pulmonary valve. Application of radiofrequency energy at this site resulted in termination and noninducibility of this VT. After 6-month follow-up, the patient remained free from VT recurrences.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of this work was to evaluate the effect of physical preconditioning in the responsiveness of rat pulmonary rings submitted to lung ischemia/reperfusion (IR). Wistar rats were divided into three groups: Sedentary sham-operated (SD/SHAM); sedentary submitted to ischemia/reperfusion (SD/IR) and trained submitted to ischemia/reperfusion (TR/IR) animals. Exercise training consisted in sessions of 60 min/day running sessions, 5 days/week for 8 weeks. Left pulmonary IR was performed by occluding for 90 min and reperfusing for 120 min. After that, pulmonary arteries were isolated and concentration-response curves to acetylcholine (ACh), histamine (HIST), sodium nitroprusside (SNP), phenylephrine and U46619 were obtained. Neither potency (- log EC50) nor maximal responses (Emax) were modified for ACh and HIST in all groups. On the other hand, the potency for SNP was significantly increased in TR/IR group (8.23 ± 0.06) compared to SD/IR group (7.85 ± 0.04). Contractile responses mediated by a-adrenergic receptor were markedly decreased in IR groups (SD/IR: 6.75 ± 0.06 and TR/IR: 6.62 ± 0.04) compared to SD/SHAM (7.33 ± 0.05). No changes were seen for the U46619 in all groups. In conclusion, the present study shows that exercise training has no protective actions in the local blood vessel where the IR process takes place. © 2006 Elsevier Inc. All rights reserved.
Resumo:
Pulmonary artery sarcomas (PAS) are rare and probably incurable tumours. The clinical manifestations are non-specific and very similar to that of patients with thromboembolic disease, resulting in delay of the correct diagnosis and proper treatment. We report the case of a 66-year-old woman with PAS diagnosed by computed tomography guided biopsy. Chemotherapy treatment was initiated but the patient died 11 months after diagnosis.
Resumo:
Clinical evidence has identified the pulmonary circulation as an important target of air pollution. It was previously demonstrated that in vitro exposure to fine particulate matter (aerodynamic diameter <= 2.5 mu m, PM2.5) induces endothelial dysfunction in isolated pulmonary arteries. We aimed to investigate the effects of in vivo exposure to urban concentrated PM2.5 on rat pulmonary artery reactivity and the mechanisms involved. For this, adult Wistar rats were exposed to 2 weeks of concentrated Sao Paulo city air PM2.5 at an accumulated daily dose of approximately 600 mu g/m(3). Pulmonary arteries isolated from PM2.5-exposed animals exhibited impaired endothelium-dependent relaxation to acetylcholine without significant changes in nitric oxide donor response compared to control rats. PM2.5 caused vascular oxidative stress and enhanced protein expression of Cu/Zn- and Mn-superoxide dismutase in the pulmonary artery. Protein expression of endothelial nitric oxide synthase (eNOS) was reduced, while tumor necrosis factor (TNF)-alpha was enhanced by PM2.5 inhalation in pulmonary artery. There was a significant positive correlation between eNOS expression and maximal relaxation response (E-max) to acetylcholine. A negative correlation was found between vascular TNF-alpha expression and E-max to acetylcholine. Plasma cytokine levels, blood cells count and coagulation parameters were similar between control and PM2.5-exposed rats. The present findings showed that in vivo daily exposure to concentrated urban PM2.5 could decrease endothelium-dependent relaxation and eNOS expression on pulmonary arteries associated with local high TNF-alpha level but not systemic pro-inflammatory factors. Taken together, the present results elucidate the mechanisms underlying the trigger of cardiopulmonary diseases induced by urban ambient levels of PM2.5. (C) 2012 Elsevier Ireland Ltd. All rights reserved.