954 resultados para Protesi totali di ginocchio, Videofluoroscopia, Guide di taglio, Custom made
Resumo:
The goal of this thesis was the study of the cement-bone interface in the tibial component of a cemented total knee prosthesis. One of the things you can see in specimens after in vivo service is that resorption of bone occurs in the interdigitated region between bone and cement. A stress shielding effect was investigated as a cause to explain bone resorption. Stress shielding occurs when bone is loaded less than physiological and therefore it starts remodeling according to the new loading conditions. µCT images were used to obtain 3D models of the bone and cement structure and a Finite Element Analysis was used to simulate different kind of loads. Resorption was also simulated by performing erosion operations in the interdigitated bone region. Finally, 4 models were simulated: bone (trabecular), bone with cement, and two models of bone with cement after progressive erosions of the bone. Compression, tension and shear test were simulated for each model in displacement-control until 2% of strain. The results show how the principal strain and Von Mises stress decrease after adding the cement on the structure and after the erosion operations. These results show that a stress shielding effect does occur and rises after resorption starts.
Resumo:
La necessità di sviluppare questo progetto è nata dal fatto che quando due aziende desiderano collaborare in maniera costruttiva con rapporti di fornitura di materiali o lavorazioni, bisogna evitare che si verifichino scostamenti nei rapporti a discapito di uno dei due contraenti. La coscienza dell'inefficienza di un rapporto squilibrato ha portato le due aziende a intavolare un progetto migliorativo basato sulla massima trasparenza e propositività. Quando G.D ha deciso di avvalersi della fornitura da parte di Transmec per quanto riguarda il servizio di taglio del materiale, l'ha fatto per andare a cercare un miglior livello di efficacia ed efficienza. Il raggiungimento degli attuali livelli di performance non sarebbe stato possibile se entrambe le aziende non avessero collaborato attivamente nell'ottenimento degli standard desiderati. Questo studio è nato dal fatto che il modello interno adottato precedentemente da G.D per la ripartizione dei costi delle Business Unit non era più efficace se utilizzato come strumento di pagamento. Si rendeva quindi necessaria un'analisi accurata della situazione produttiva utilizzando gli approcci analitici resi disponibili nel corso degli anni come lo strumento per l'allocazione dei costi secondo le attività (Activity Based Costing) e la mappatura dei processi utilizzata nei casi di re-ingegnerizzazione dei reparti.
Resumo:
L’attività della tesi riguarda le protesi mioelettriche, gli arti protesici maggiormente diffusi, le quali sono descrivibili come arti robotici in cui i segmenti artificiali sono attuati da giunti elettromeccanici alimentati da batterie ricaricabili ed attivati mediante segnali elettromiografici (segnali elettrici generati dalla contrazione dei muscoli). Tali protesi di arto superiore attualmente disponibili in commercio potrebbero essere inadeguate per una riabilitazione soddisfacente di alcuni pazienti con una amputazione di alto livello che richiedono una elevata funzionalità nella vita quotidiana. In questo contesto si inserisce l’attività di ricerca del Centro Protesi INAIL di Budrio di Vigorso, Bologna, e dell’Università di Bologna i quali stanno sviluppando nuovi arti protesici con il progetto a lungo termine di rendere disponibili svariate soluzioni di protesi di arto superiore in grado di soddisfare la maggior parte delle richieste degli amputati. Lo scopo di questa tesi è l’introduzione di un nuovo rotatore omerale attivo da integrare alla protesi di arto superiore disponibile presso i nostri laboratori. Per ottenere questo risultato è stata utilizzata una procedura di progettazione già consolidata in attività precedenti per lo sviluppo di una protesi di spalla a due gradi di libertà. Differenti modelli cinematici sono stati studiati tramite analisi cinematiche per determinare l’incremento delle prestazioni a seguito dell’introduzione del nuovo rotatore omerale attivo. Sono state inoltre condotte analisi cinetostatiche per definire le specifiche tecniche di riferimento (in termini di carichi agenti sul rotatore omerale) e per guidare il dimensionamento della catena di trasmissione di potenza del nuovo dispositivo protesico. Ulteriori specifiche tecniche sono state considerate per garantire l’irreversibilità spontanea del moto sotto carichi esterni (quando i giunti attivi della protesi non sono alimentati), per salvaguardare l’incolumità del paziente in caso di caduta, per misurare la posizione angolare del rotatore omerale (in modo da implementare strategie di controllo in retroazione) e per limitare i consumi e la rumorosità del dispositivo. Uno studio di fattibilità ha permesso la selezione della architettura ottimale della catena di trasmissione di potenza per il nuovo rotatore omerale. I criteri di scelta sono stati principalmente la limitazione del peso e dell’ingombro del nuovo dispositivo protesico. Si è quindi proceduto con la progettazione di dettaglio alla quale è seguita la costruzione di un prototipo del nuovo rotatore omerale presso i nostri laboratori. La tesi tratta infine una attività preliminare di sperimentazione che ha permesso di fare considerazioni sulle prestazioni del prototipo ed osservazioni importanti per le successive attività di revisione ed ottimizzazione del progetto del rotatore omerale.
Resumo:
Con il passare degli anni le tecnologie nel campo delle protesi mioelettriche di arto superiore stanno compiendo sempre più passi in avanti. In questo elaborato di tesi si darà un iniziale introduzione sulla protesica di arto superiore cercando di coprire tutte le possibili tipologie di protesi, prestando particolare attenzione agli arti artificiali mioelettrici. Gli scopi di questo studio sono in prima analisi una miglioria dell'unità di controllo di una protesi comandata da segnali elettromiografici di superficie, tramite l'utilizzo del nuovo IDE della Microchip (MPLAB X). In seconda analisi, invece, si attuerà un confronto prestazionale a livello di consumo in corrente di un prototipo di protesi mioelettrica nata dalla sinergia tra l'azienda "Selex ES" e il "Centro Protesi INAIL di Vigorso di Budrio". Per questo studio ci si è serviti di stereofotogrammetrica per la determinazione delle grandezze meccaniche, mentre tramite un sistema PAC si è riusciti ad ottenere specifiche grandezze elettriche. Lo studio ha portato, a livello di Firmware, l'inserimento del giusto comando di attuazione di un servofreno comandato in corrente e l'introduzione di una particolare modalità a basso consumo che consente un risparmio energetico di circa il 60% rispetto alla vecchia modalità. Discorso diverso per i risultati del confronto prestazionale che non ha portato ai risultati sperati in fase di progetto.
Resumo:
The aim of this work is to evaluate the emissions of the main pollutants of a pellet stove, by trying to simulate the real use in domestic operations. All the operating phases of this system were considered: ignition, partial load, increase in power, and nominal load. In each phase, quantity and type of some pollutants in emissions were determined: the main pollutant gases (CO, NOx, SO2, H2S and volatile organic compounds (VOCs)), total dust (PM) and its content of polycyclic aromatic hydrocarbons (PAHs), regulated heavy metals (Ni, Cd, As and Pb), main soluble ions and Total Carbon (TC). Results show that emission factors of TSP, CO, and of the main determined pollutants (TC, Cd and PAHs) are higher during ignition phase. In particular, this phase prevalently contributes to PAHs emissions. During increase in power phase, gas and particulate emissions do not appreciably differ from nominal load ones; nevertheless, PAH emission factors are higher than steady state ones, but lower than ignition phase. Moreover, during not-steady state phases, PAH mixture is more toxic than during steady state phases. In conclusion, this study allowed to go deeper in pellet stove environmental impact, by pointing out how the different operating conditions can modify the emissions. These are different from certificated data, which are based exclusively on measurements in steady state conditions.
Resumo:
Restoring a correct implant kinematics and providing a good ligament balance and patellar tracking is mandatory to improve clinical and functional outcome after a Total Knee Replacement. Surgical navigation systems are a reliable and accurate tool to help the surgeon in achieving these goals. The aim of the present study was to use navigation system with an intra-operative surgical protocol to evaluate and determine an optimal implant kinematics during a Total Knee Replacement.
Resumo:
L’elaborato propone un’analisi dettagliata della configurazione del discorso pubblicitario, inteso come il risultato di una duplice operazione: quella di produzione del messaggio, a opera del pubblicitario, utente di precise strategie discorsive, e quella di interpretazione, da parte del destinatario che completa il significato dell’enunciato attribuendogli le proprie peculiari connotazioni. Il corpus utilizzato consiste in una raccolta di spot pubblicitari prodotti dall’azienda Barilla per i telespettatori francofoni, ed è stato reperito presso l’Archivio Storico di Barilla nella sede di Parma. L’illustrazione e la descrizione di alcune pubblicità scelte come modelli forniscono la base per l’approfondimento di alcune problematiche linguistiche e traduttologiche; in particolare, viene posto l’accento sulla nozione di ethos discorsivo, collocabile nell'ambito dell’analisi del discorso, e su quella di stereotipo linguistico, considerato come veicolo culturale e strumento dotato di straordinaria forza assertiva e pertanto prediletto dalla comunicazione pubblicitaria. Tale forma di linguaggio merita di essere analizzata e studiata nella sua ricca complessità, dal momento che è da considerarsi come il più efficace e moderno mezzo di diffusione, incorporazione e assimilazione di valori e comportamenti culturalmente orientati.
Resumo:
Il mondo dei materiali compositi è in continua espansione, e sono sempre di più le aziende che richiedono componenti prodotti con questi materiali, uno dei quali è la fibra di carbonio. Tali aziende producono inevitabilmente scarti di lavorazione derivanti dal taglio di sagome dai fogli di fibra di carbonio; questi ritagli rappresentano ancora una buona materia prima, che, se ben conservata, può essere utilizzata per la fabbricazione di prodotti secondari. Così facendo sarà possibile ridurre il costo di smaltimento della fibra, e, al contempo, ottenere manufatti in fibra di carbonio a basso costo. È in questo contesto che rientra il lavoro e la ricerca di questo elaborato il cui obbiettivo è riutilizzare gli sfridi di lavorazione per realizzare protesi di piede a basso costo in fibra di carbonio. Un ulteriore attenzione è stata posta al metodo di fabbricazione della protesi, il quale deve risultare semplice da realizzare. Per questa ragione si è deciso che la pressione durante la cottura fosse da applicare per via meccanica, attraverso la presenza di uno stampo e di un controstampo, serrati tramite collegamenti bullonati. Nell’elaborato sarà descritto il lavoro svolto per l’ottenimento della forma e della disposizione degli strati di fibra di carbonio, basato su simulazione di modelli ad elementi finiti, che ha condotto alle migliori sagome e al miglior orientamento delle fibre negli strati di materiale composito. Sarà inoltre illustrato il metodo utilizzato per ottenere lo stampo, e le procedure da seguire per la realizzazione del prototipo di protesi. Saranno infine illustrati i risultati ottenuti dalle prove di caratterizzazione di due prototipi differenti, uno ottenuto con fibre intere, e uno realizzato con fibre corte.
Resumo:
Lo scopo del lavoro è quello di verificare tramite software CAD l’influenza dei principali parametri chirurgici e anatomici sul Range Of Motion (ROM). Sono stati costruiti 5 modelli, uno di articolazione sana(Senza Protesi), uno di protesi Convenzionale e tre di protesi Conservative o a Conservazione (Totale, Media e Bassa Conservazione). Per tutti i modelli sono state simulate le rotazioni di base e i cosiddetti movimenti critici, ovvero quei movimenti a rischio di lussazione. Le prove sono state eseguite per teste da 28-,32-,36-,40mm di diametro, e con la coppa orientata di 45° in abduzione e 15° gradi in antiversione prima e successivamente di 45° e 0°. Inoltre, per verificare l’influenza dell’offset sul ROM, sono stati costruiti e simulati i movimenti per altri 5 modelli che non conservassero il vincolo del mantenere l’offset anatomico. Variando il diametro della testa si registrano differenze apprezzabili in termini di ROM solo per i movimenti di Estensione e Abduzione per il modello di Protesi Convenzionale e di Abduzione per il modello a Bassa Conservazione. Variando il livello di resezione del collo si è visto come per i modelli di protesi a Media Conservazione, Bassa Conservazione e Convenzionale si misurano angoli superiori a quello del riferimento tratto dalla Letteratura. Diversamente per il modello di Protesi a Totale Conservazione i valori ottenuti per alcuni movimenti sono inferiori, poiché limitati da un contatto di tipo c-b. Le simulazioni dei movimenti critici confermano la tendenza di un ROM accettabile per i modelli di protesi a Bassa Conservazione e di protesi Convenzionale, i quali forniscono escursioni angolari sempre superiori a quelle prese come riferimento dalla Letteratura. Invece, le protesi a Totale e Media Conservazione forniscono valori inferiori al riferimento per i movimenti di Pivot e Roll, essendo limitati dall’antiversione della coppa (movimenti di ExtraRotazione e contatto c-b). Variando la posizione della coppa a 45°/0° i due movimenti Critici Pivot e Roll migliorano per i modelli a Totale e Media Conservazione, tornando in linea con il riferimento. Riguardo l’offset si nota come più si avvicina a quello anatomico che misura 46,2mm (da 37 a 44mm), più si riscontra un aumento in termini di ROM.
Resumo:
Questo studio ha valutato l'efficacia di un approccio rigenerativo utilizzando cellule staminali mesenchimali (MSC) e uno scaffold di idrossiapatite pura e porosa (HA) progettata con tecnologia CAD-CAM per sostituire il condilo dell'articolazione temporomandibolare (ATM). Metodi.Uno scaffolds di HA con porosità totale del 70% è stato prototipato per sostituire i due condili temporomandibolari (sinistro e destro) dello stesso animale. MSC sono state ottenute dalla cresta iliaca ed espanse in coltura. Guide chirurgiche su misura sono state create e utilizzate per esportare la pianificazione virtuale delle linee di taglio dell'osso nell'ambiente chirurgico. Sei pecore sono state sacrificate a 4 mesi dopo l'intervento.Gli scaffold sono stati espiantati, campioni istologici sono stati preparati, ed è stata eseguota l'analisi istomorfometrica. Risultati.L'analisi della riduzione di porosità per apposizione di osso neoformato mostrata una differenza statisticamente significativa tra la formazione ossea nei condili carichi di MSC rispetto ai condili senza (
Resumo:
Una tracciato anormale della rotula può provocare dolore anteriore al ginocchio dopo un’artroplastica e può condurre al fallimento dell’intervento stesso. È importante quindi valutare questo tracciato sia intra che post-operatoriamente, anche per validare disegni protesici innovativi e supportare il chirurgo per le più critiche decisioni chirurgiche al momento dell’impianto. Ad oggi però le valutazioni in-vivo della cinematica femoro-rotulea sono poche e poco attendibili; è per questi motivi che abbiamo deciso di analizzare l’articolazione con la tecnica video-fluoroscopica, appositamente adattata allo scopo di tale studio, a sei mesi di follow-up dall’intervento. Per lo studio abbiamo esaminato, tramite video-fluoroscopia 3D, sette pazienti che hanno subito l’impianto di una protesi totale al ginocchio con ricopertura della rotula. Successivamente le immagini sono state elaborate con un apposito software per ricostruire la cinematica 3D, e sono stati ottenuti i grafici per ogni grado di libertà dell’articolazione. Dall’analisi dei risultati, la tecnica utilizzata è risultata fattibile ed affidabile, infatti dai grafici si nota come la normale cinematica delle articolazioni studiate sia stata ripristinata. Questo studio, oltre a validare l’applicazione della tecnica video-fluoroscopica all’articolazione femoro-rotulea oltre che a quella tibio-femorale, dopo un confronto con i dati derivanti dalla navigazione chirurgica, ha consentito di validare anche questa tecnica intra-operatoria. Questo risultato potrà condurre ad una maggiore precisione nell’allineamento delle componenti protesiche da parte del chirurgo, con conseguente riduzione del rischio di fallimento dell’impianto.