994 resultados para Protective devices


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The optimized allocation of protective devices in strategic points of the circuit improves the quality of the energy supply and the system reliability index. This paper presents a nonlinear integer programming (NLIP) model with binary variables, to deal with the problem of protective device allocation in the main feeder and all branches of an overhead distribution circuit, to improve the reliability index and to provide customers with service of high quality and reliability. The constraints considered in the problem take into account technical and economical limitations, such as coordination problems of serial protective devices, available equipment, the importance of the feeder and the circuit topology. The use of genetic algorithms (GAs) is proposed to solve this problem, using a binary representation that does (1) or does not (0) show allocation of protective devices (reclosers, sectionalizers and fuses) in predefined points of the circuit. Results are presented for a real circuit (134 busses), with the possibility of protective device allocation in 29 points. Also the ability of the algorithm in finding good solutions while improving significantly the indicators of reliability is shown. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Optimised placement of control and protective devices in distribution networks allows for a better operation and improvement of the reliability indices of the system. Control devices (used to reconfigure the feeders) are placed in distribution networks to obtain an optimal operation strategy to facilitate power supply restoration in the case of a contingency. Protective devices (used to isolate faults) are placed in distribution systems to improve the reliability and continuity of the power supply, significantly reducing the impacts that a fault can have in terms of customer outages, and the time needed for fault location and system restoration. This paper presents a novel technique to optimally place both control and protective devices in the same optimisation process on radial distribution feeders. The problem is modelled through mixed integer non-linear programming (MINLP) with real and binary variables. The reactive tabu search algorithm (RTS) is proposed to solve this problem. Results and optimised strategies for placing control and protective devices considering a practical feeder are presented. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, an expert and interactive system for developing protection system for overhead and radial distribution feeders is proposed. In this system the protective devices can be allocated through heuristic and an optimized way. In the latter one, the placement problem is modeled as a mixed integer non-linear programming, which is solved by genetic algorithm (GA). Using information stored in a database as well as a knowledge base, the computational system is able to obtain excellent conditions of selectivity and coordination for improving the feeder reliability indices. Tests for assessment of the algorithm efficiency were carried out using a real-life 660-nodes feeder. © 2006 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The consequences of falls are often dreadful for individuals with lower limb amputation using bone-anchored prosthesis.[1-5] Typically, the impact on the fixation is responsible for bending the intercutaneous piece that could lead to a complete breakage over time. .[3, 5-8] The surgical replacement of this piece is possible but complex and expensive. Clearly, there is a need for solid data enabling an evidence-based design of protective devices limiting impact forces and torsion applied during a fall. The impact on the fixation during an actual fall is obviously difficult to record during a scientific experiment.[6, 8-13] Consequently, Schwartze and colleagues opted for one of the next best options science has to offer: simulation with an able-bodied participant. They recorded body movements and knee impacts on the floor while mimicking several plausible falling scenarios. Then, they calculated the forces and moments that would be applied at four levels along the femur corresponding to amputation heights.[6, 8-11, 14-25] The overall forces applied during the falls were similar regardless of the amputation height indicating that the impact forces were simply translated along the femur. As expected, they showed that overall moments generally increased with amputation height due to changes in lever arm. This work demonstrates that devices preventing only against force overload do not require considering amputation height while those protecting against bending moments should. Another significant contribution is to provide, for the time, the magnitude of the impact load during different falls. This loading range is crucial to the overall design and, more precisely, the triggering threshold of protective devices. Unfortunately, the analysis of only a single able-bodied participant replicating falls limits greatly the generalisation of the findings. Nonetheless, this case study is an important milestone contributing to a better understanding of load impact during a fall. This new knowledge will improve the treatment, the safe ambulation and, ultimately, the quality of life of individuals fitted with bone-anchored prosthesis.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Sports venues are in a position to potentially influence the safety practices of their patrons. This study examined the knowledge, beliefs and attitudes of venue operators that could influence the use of protective eyewear by squash players. A 50% random sample of all private and public squash venues affiliated with the Victorian Squash Federation in metropolitan Melbourne was selected. Face-to-face interviews were conducted with 15 squash venue operators during August 2001. Interviews were transcribed and content and thematic analyses were performed. The content of the interviews covered five topics: (1) overall injury risk perception, (2) eye injury occurrence, (3) knowledge, behaviors, attitudes and beliefs associated with protective eyewear, (4) compulsory protective eyewear and (5) availability of protective eyewear at venues. Venue operators were mainly concerned with the severe nature of eye injuries, rather than the relatively low incidence of these injuries. Some venue operators believed that players should wear any eyewear, rather than none at all, and believed that more players should use protective eyewear. Generally, they did not believe that players with higher levels of experience and expertise needed to wear protective eyewear when playing. Only six venues had at least one type of eyewear available for players to hire or borrow or to purchase. Operators expressed a desire to be informed about correct protective eyewear. Appropriate protective eyewear is not readily available at squash venues. Better-informed venue operators may be more likely to provide suitable protective eyewear.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Isolation of a faulted segment, from either side of a fault, in a radial feeder that has several converter interfaced DGs is a challenging task when current sensing protective devices are employed. The protective device, even if it senses a downstream fault, may not operate if fault current level is low due to the current limiting operation of converters. In this paper, a new inverse type relay is introduced based on line admittance measurement to protect a distribution network, which has several converter interfaced DGs. The basic operation of this relay, its grading and reach settings are explained. Moreover a method is proposed to compensate the fault resistance such that the relay operation under this condition is reliable. Then designed relay performances are evaluated in a radial distribution network. The results are validated through PSCAD/EMTDC simulation and MATLAB calculations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

With the rapid increase in electrical energy demand, power generation in the form of distributed generation is becoming more important. However, the connections of distributed generators (DGs) to a distribution network or a microgrid can create several protection issues. The protection of these networks using protective devices based only on current is a challenging task due to the change in fault current levels and fault current direction. The isolation of a faulted segment from such networks will be difficult if converter interfaced DGs are connected as these DGs limit their output currents during the fault. Furthermore, if DG sources are intermittent, the current sensing protective relays are difficult to set since fault current changes with time depending on the availability of DG sources. The system restoration after a fault occurs is also a challenging protection issue in a converter interfaced DG connected distribution network or a microgrid. Usually, all the DGs will be disconnected immediately after a fault in the network. The safety of personnel and equipment of the distribution network, reclosing with DGs and arc extinction are the major reasons for these DG disconnections. In this thesis, an inverse time admittance (ITA) relay is proposed to protect a distribution network or a microgrid which has several converter interfaced DG connections. The ITA relay is capable of detecting faults and isolating a faulted segment from the network, allowing unfaulted segments to operate either in grid connected or islanded mode operations. The relay does not make the tripping decision based on only the fault current. It also uses the voltage at the relay location. Therefore, the ITA relay can be used effectively in a DG connected network in which fault current level is low or fault current level changes with time. Different case studies are considered to evaluate the performance of the ITA relays in comparison to some of the existing protection schemes. The relay performance is evaluated in different types of distribution networks: radial, the IEEE 34 node test feeder and a mesh network. The results are validated through PSCAD simulations and MATLAB calculations. Several experimental tests are carried out to validate the numerical results in a laboratory test feeder by implementing the ITA relay in LabVIEW. Furthermore, a novel control strategy based on fold back current control is proposed for a converter interfaced DG to overcome the problems associated with the system restoration. The control strategy enables the self extinction of arc if the fault is a temporary arc fault. This also helps in self system restoration if DG capacity is sufficient to supply the load. The coordination with reclosers without disconnecting the DGs from the network is discussed. This results in increased reliability in the network by reduction of customer outages.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents an Artificial Neural Network (ANN) approach for locating faults in distribution systems. Different from the traditional Fault Section Estimation methods, the proposed approach uses only limited measurements. Faults are located according to the impedances of their path using a Feed Forward Neural Networks (FFNN). Various practical situations in distribution systems, such as protective devices placed only at the substation, limited measurements available, various types of faults viz., three-phase, line (a, b, c) to ground, line to line (a-b, b-c, c-a) and line to line to ground (a-b-g, b-c-g, c-a-g) faults and a wide range of varying short circuit levels at substation, are considered for studies. A typical IEEE 34 bus practical distribution system with unbalanced loads and with three- and single- phase laterals and a 69 node test feeder with different configurations are considered for studies. The results presented show that the proposed approach of fault location gives close to accurate results in terms of the estimated fault location.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIMS AND OBJECTIVES: This cross sectional descriptive study was designed to survey patient opinion towards dental clinical attire, name badges and commonly used cross-infection control measures.

METHOD: Patients attending a dental hospital for a consultation appointment were asked to complete a questionnaire accompanied by photographs of models portraying a range of clinical attire. A representative sample of patients completed 188 questionnaires over a four week period.

RESULTS: The study found that the majority of patients felt clinical attire was important and that they preferred dental professionals to wear name badges. The majority of patients also preferred dentists to use both safety glasses and face masks. When asked to indicate which clinical attire was most appropriate for a consultant/specialist to wear, the overwhelming opinion was that of smart dress accompanied with a white coat. In addition, most respondents wished their dentist to wear a traditional white, dental tunic.

CONCLUDING REMARKS: It is hoped that this study will be informative for the dental team and that the results will be taken into consideration when considering appropriate clinical attire in accordance with patient opinions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper discusses a study to determine selection of hearing protective devices to ensure optimum speech discrimination.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Motorcycle crash victims form a high proportion of those killed or injured in road traffic accidents. Injuries to the head, following motorcycle crashes, are a common cause of severe morbidity and mortality. It seems intuitive that helmets should protect against head injuries but it has been argued that motorcycle helmet use decreases rider vision and increases neck injuries. This review will collate the 'current available evidence on helmets and their impact on mortality, and head, face and neck injuries following motorcycle crashes.

Objectives: To quantify the effectiveness of wearing a motorcycle helmet in reducing mortality and head and neck injury following motorcycle crashes.

Search strategy: Databases including the Cochrane Injuries Group Specialised Register, Cochrane Central Register of Controlled Trials (The Cochrane Library issue 1,2003), MEDLINE (January 1966 to February 2003), EMBASE (January 1985 to February 2003), CINAHL (January 1982 to February 2003), IRRD (International Road Research Documentation), TRANSDOC, TRIS (Transport Research Information Service), ATRI (Australian Transport Index) (1976 to Feb 2003), Science Citation Index were searched for relevant articles. Web sites of traffic and road accident research bodies including government agencies were also searched. Reference lists from topic reviews, identified studies and bibliographies were examined for relevant articles.

Selection criteria: We considered for inclusion studies that investigated a population of motorcycle riders who had crashed, examining helmet use as an intervention and with outcomes that included one or more of the following: death, head, neck or facial injury. Studies included any that compared an intervention and control group and, therefore, included any randomised controlled trials, non-randomised controlled trials, cohort, case-control and cross-sectional studies. Ecological and case series studies were excluded.

Data collection and analysis: Two reviewers independently screened reference lists for eligible articles. Two reviewers independently assessed articles for inclusion criteria. Data were abstracted by two independent reviewers using a standard abstraction form.

Main results: Fifty-three observational studies were identified of varying quality. Despite methodological differences there was a remarkable consistency in results, particularly for mortality and head injury outcomes. Motorcycle helmets appear to reduce the risk of mortality although, due to heterogeneity in study design, an overall estimate of effect was not calculated. There was some evidence that the effect of helmets on mortality is modified by speed. Motorcycle helmets were found to reduce the risk of head injury and from five well-conducted studies the risk reduction is estimated to be 72% (OR 0.28, 95%CI 0.23,0.35). Insufficient evidence was found to estimate the effect of motorcycle helmets compared with no helmet on facial or neck injuries. However, studies of poorer quality suggest that helmets have no effect on the risk of neck injuries and are protective for facial injury. There was insufficient evidence to demonstrate whether differences in helmet type confer more or less advantage in injury reduction.

Conclusions:
Motorcycle helmets reduce the risk of mortality and head injury in motorcycle riders who crash, although the former effect may be modified by other crash factors such as speed. Further well-conducted research is required to determine the effects of helmets and different helmet types on mortalIty, head, neck and facial injuries. However, the findings suggest that global efforts to reduce road traffic injuries may be facilitated by increasing helmet use by motorcyclists.