24 resultados para Prodigy
Resumo:
The trabecular bone score (TBS, Med-Imaps, Pessac, France) is an index of bone microarchitecture texture extracted from anteroposterior dual-energy X-ray absorptiometry images of the spine. Previous studies have documented the ability of TBS of the spine to differentiate between women with and without fractures among age- and areal bone mineral density (aBMD)-matched controls, as well as to predict future fractures. In this cross-sectional analysis of data collected from 3 geographically dispersed facilities in the United States, we investigated age-related changes in the microarchitecture of lumbar vertebrae as assessed by TBS in a cohort of non-Hispanic US white American women. All subjects were 30 yr of age and older and had an L1-L4aBMDZ-score within ±2 SD of the population mean. Individuals were excluded if they had fractures, were on any osteoporosis treatment, or had any illness that would be expected to impact bone metabolism. All data were extracted from Prodigy dual-energy X-ray absorptiometry devices (GE-Lunar, Madison, WI). Cross-calibrations between the 3 participating centers were performed for TBS and aBMD. aBMD and TBS were evaluated for spine L1-L4 but also for all other possible vertebral combinations. To validate the cohort, a comparison between the aBMD normative data of our cohort and US non-Hispanic white Lunar data provided by the manufacturer was performed. A database of 619 non-Hispanic US white women, ages 30-90 yr, was created. aBMD normative data obtained from this cohort were not statistically different from the non-Hispanic US white Lunar normative data provided by the manufacturer (p = 0.30). This outcome thereby indirectly validates our cohort. TBS values at L1-L4 were weakly inversely correlated with body mass index (r = -0.17) and weight (r = -0.16) and not correlated with height. TBS values for all lumbar vertebral combinations decreased significantly with age. There was a linear decrease of 16.0% (-2.47 T-score) in TBS at L1-L4 between 45 and 90 yr of age (vs. -2.34 for aBMD). Microarchitectural loss rate increased after age 65 by 50% (-0.004 to -0.006). Similar results were obtained for other combinations of lumbar vertebra. TBS, an index of bone microarchitectural texture, decreases with advancing age in non-Hispanic US white women. Little change in TBS is observed between ages 30 and 45. Thereafter, a progressive decrease is observed with advancing age. The changes we observed in these American women are similar to that previously reported for a French population of white women (r(2) > 0.99). This reference database will facilitate the use of TBS to assess bone microarchitectural deterioration in clinical practice.
Resumo:
Objectives: Trabecular Bone Score (TBS, Med-Imaps, France) is an index of bone microarchitecture calculated from antero-posterior spine DXA scan and reported to be associated with fracture in prior case-control studies and in a large prospective study with the Prodigy DXA device. Our aim was to assess the ability of TBS to predict incident fracture and improve the classification of fracture prospectively in the OFELY study.Materials/Methods: TBS was assessed in 564 postmenopausal women (66±8 years old) from the OFELY cohort, who had a spine DXA scan (QDR 4500A, Hologic, USA) between year 2000 and 2001. During a mean follow up of 7.8±1.3 years, 94 women sustained a fragility fracture.Results: At the time of baseline DXA scan, women with incident fracture were significantly older (70±9 vs. 65± 8 years), had a lower spine BMD (T-score: −1.9±1.2 vs. −1.3±1.3, p<0.001) and spine TBS (−3.1%, p<0.001) than women without incident fracture. After adjustment for age, BMI and the presence of prevalent fracture, the magnitude of fracture prediction was similar for spine BMD (OR=1.42 [1.11;1.82] per SD decrease [95% CI]) and TBS (OR=1.34 [1.04;1.74]) but the combination of TBS and spine BMD did not improve fracture prediction. Spine BMD and TBS were both correlated with age (respectively r=−0.17 and −0.49, p<0.001) and correlated together with 39% of TBS explained by spine BMD (r=0.63, p<0.001). When using the WHO classification, 38% of the fractures occurred in osteoporotic (fracture rate=29%), 47% in osteopenic (fracture rate=16%) and 15% in women with T-score >−1 (fracture rate=9%). By classifying our population in tertiles of TBS, we found that 47% of the fractures occurred in the lowest tertile of TBS (fracture rate=23%) and 39% of the fracture that occurred in osteopenic women were in the lowest tertile of TBS.Conclusions: Spine BMD and TBS predicted fractures equally well. The addition of TBS to spine BMD added only limited information on fracture risk prediction in our cohort when considering the all range of BMD. Nevertheless combining the osteopenic T-score and the lowest TBS helped defining a subset of osteopenic women at higher risk of fracture.Disclosure of Interest: None declared.
Resumo:
INTRODUCTION: Although osteoporosis is considered a disease of women, 25% of the individuals with osteoporosis are men. BMD measurement by DXA is the gold standard used to diagnose osteoporosis and assess fracture risk. Nevertheless, BMD does not take into account alterations of microarchitecture. TBS is an index of bone microarchitecture extracted from the spine DXA. Previous studies have reported the ability of the spine TBS to predict osteoporotic fractures in women. This is the first case-controlled study in men to evaluate the potential diagnostic value of TBS as a complement to bone mineral density (BMD), by comparing men with and without fractures. METHODS: To be eligible for this study, subjects had to be non-Hispanic US white men aged 40 and older. Furthermore, subjects were excluded if they have or have had previously any treatment or illness that may influence bone metabolism. Fractured subjects were included if the presence of at least one fracture was confirmed. Cases were matched for age (±3 years) and BMD (±0.04 g/cm(2)) with three controls. BMD and TBS were first retrospectively evaluated at AP spine (L1-L4) with a Prodigy densitometer (GE-Lunar, Madison, USA) and TBS iNsight® (Med-Imaps, France) in Lausanne University Hospital blinded from clinical outcome. Inter-group comparisons were undertaken using Student's t-tests or Wilcoxon signed rank tests. Odds ratios were calculated per one standard deviation decrease as well as areas under the receiver operating curve (AUC). RESULTS: After applying inclusion/exclusion criteria, a group of 180 male subjects was obtained. This group consists of 45 fractured subjects (age=63.3±12.6 years, BMI=27.1±4.2 kg/m(2)) and 135 control subjects (age=62.9±11.9 years, BMI=26.7±3.9 kg/m(2)) matched for age (p=0.86) and BMD (p=0.20). A weak correlation was obtained between TBS and BMD and between TBS and BMI (r=0.27 and r=-0.28, respectively, p<0.01). Subjects with fracture have a significant lower TBS compared to control subjects (p=0.013), whereas no differences were obtained for BMI, height and weight (p>0.10). TBS OR per standard deviation is 1.55 [1.09-2.20] for all fracture type. When considering vertebral fracture only TBS OR reached 2.07 [1.14-3.74]. CONCLUSION: This study showed the potential use of TBS in men. TBS revealed a significant difference between fractured and age- and spine BMD-matched nonfractured subjects. These results are consistent with those previously reported on for men of other nationalities.
Resumo:
Developing a novel technique for the efficient, noninvasive clinical evaluation of bone microarchitecture remains both crucial and challenging. The trabecular bone score (TBS) is a new gray-level texture measurement that is applicable to dual-energy X-ray absorptiometry (DXA) images. Significant correlations between TBS and standard 3-dimensional (3D) parameters of bone microarchitecture have been obtained using a numerical simulation approach. The main objective of this study was to empirically evaluate such correlations in anteroposterior spine DXA images. Thirty dried human cadaver vertebrae were evaluated. Micro-computed tomography acquisitions of the bone pieces were obtained at an isotropic resolution of 93μm. Standard parameters of bone microarchitecture were evaluated in a defined region within the vertebral body, excluding cortical bone. The bone pieces were measured on a Prodigy DXA system (GE Medical-Lunar, Madison, WI), using a custom-made positioning device and experimental setup. Significant correlations were detected between TBS and 3D parameters of bone microarchitecture, mostly independent of any correlation between TBS and bone mineral density (BMD). The greatest correlation was between TBS and connectivity density, with TBS explaining roughly 67.2% of the variance. Based on multivariate linear regression modeling, we have established a model to allow for the interpretation of the relationship between TBS and 3D bone microarchitecture parameters. This model indicates that TBS adds greater value and power of differentiation between samples with similar BMDs but different bone microarchitectures. It has been shown that it is possible to estimate bone microarchitecture status derived from DXA imaging using TBS.
Resumo:
Age-related changes in lumbar vertebral microarchitecture are evaluated, as assessed by trabecular bone score (TBS), in a cohort of 5,942 French women. The magnitude of TBS decline between 45 and 85 years of age is piecewise linear in the spine and averaged 14.5 %. TBS decline rate increases after 65 years by 50 %. INTRODUCTION: This study aimed to evaluate age-related changes in lumbar vertebral microarchitecture, as assessed by TBS, in a cohort of French women aged 45-85 years. METHODS: An all-comers cohort of French Caucasian women was selected from two clinical centers. Data obtained from these centers were cross-calibrated for TBS and bone mineral density (BMD). BMD and TBS were evaluated at L1-L4 and for all lumbar vertebrae combined using GE-Lunar Prodigy densitometer images. Weight, height, and body mass index (BMI) also were determined. To validate our all-comers cohort, the BMD normative data of our cohort and French Prodigy data were compared. RESULTS: A cohort of 5,942 French women aged 45 to 85 years was created. Dual-energy X-ray absorptiometry normative data obtained for BMD from this cohort were not significantly different from French prodigy normative data (p = 0.15). TBS values at L1-L4 were poorly correlated with BMI (r = -0.17) and weight (r = -0.14) and not correlated with height. TBS values obtained for all lumbar vertebra combined (L1, L2, L3, L4) decreased with age. The magnitude of TBS decline at L1-L4 between 45 and 85 years of age was piecewise linear in the spine and averaged 14.5 %, but this rate increased after 65 years by 50 %. Similar results were obtained for other region of interest in the lumbar spine. As opposed to BMD, TBS was not affected by spinal osteoarthrosis. CONCLUSION: The age-specific reference curve for TBS generated here could therefore be used to help clinicians to improve osteoporosis patient management and to monitor microarchitectural changes related to treatment or other diseases in routine clinical practice.
Resumo:
The aim of the study was to assess the clinical performance of the model combining areal bone mineral density (aBMD) at spine and microarchitecural texture (TBS) for the detection of the osteoporotic fracture. The Eastern European Study is a multicenter study (Serbia, Bulgaria, Romania and Ukraine) evaluating the role of TBS in routine clinical practice as a complement to aBMD. All scans were acquired on Hologic Discovery and GE Prodigy densitometers in a routine clinical manner. The additional clinical values of aBMD and TBS were analyzed using a two steps classification tree approach (aBMD followed by TBS tertiles) for all type of osteoporotic fracture (All-OP Fx). Sensitivity, specificity and accuracy of fracture detection as well as the Net Reclassification Index (NRI) were calculated. This study involves 1031 women subjects aged 45 and older recruited in east European countries. Clinical centers were cross-calibrated in terms of BMD and TBS. As expected, areal BMD (aBMD) at spine and TBS were only moderately correlated (r (2) = 0.19). Prevalence rate for All-OP Fx was 26 %. Subjects with fracture have significant lower TBS and aBMD than subjects without fracture (p < 0.01). TBS remains associated with the fracture even after adjustment for age and aBMD with an OR of 1.27 [1.07-1.51]. When using aBMD T-score of -2.5 and the lowest TBS tertile thresholds, both BMD and TBS were similar in terms of sensitivity (35 vs. 39 %), specificity (78 vs. 80 %) and accuracy (64 vs. 66 %). aBMD and TBS combination, induced a significant improvement in sensitivity (+28 %) and accuracy (+17 %) compared to aBMD alone whereas a moderate improvement was observed in terms of specificity (+9 %). The overall combination gain was 36 % as expressed using the NRI. aBMD and TBS combination decrease significantly the number of subjects needed to diagnose from 7 for aBMD alone to 2. In a multi-centre Eastern European cohort, we have shown that the use of TBS in addition to the aBMD permit to reclassified correctly more than one-third of the overall subjects. Furthermore, the number of subjects needed to diagnose fell to 2 subjects. Economical studies have to be performed to evaluate the gain induced by the use of TBS for the healthcare system.
Resumo:
In a cohort study of 182 consecutive patients with active endogenous Cushing's syndrome, the only predictor of fracture occurrence after adjustment for age, gender bone mineral density (BMD) and trabecular bone score (TBS) was 24-h urinary free cortisol (24hUFC) levels with a threshold of 1472 nmol/24 h (odds ratio, 3.00 (95 % confidence interval (CI), 1.52-5.92); p = 0.002). INTRODUCTION: The aim was to estimate the risk factors for fracture in subjects with endogenous Cushing's syndrome (CS) and to evaluate the value of the TBS in these patients. METHODS: All enrolled patients with CS (n = 182) were interviewed in relation to low-traumatic fractures and underwent lateral X-ray imaging from T4 to L5. BMD measurements were performed using a DXA Prodigy device (GEHC Lunar, Madison, Wisconsin, USA). The TBS was derived retrospectively from existing BMD scans, blinded to clinical outcome, using TBS iNsight software v2.1 (Medimaps, Merignac, France). Urinary free cortisol (24hUFC) was measured by immunochemiluminescence assay (reference range, 60-413 nmol/24 h). RESULTS: Among enrolled patients with CS (149 females; 33 males; mean age, 37.8 years (95 % confidence interval, 34.2-39.1); 24hUFC, 2370 nmol/24 h (2087-2632), fractures were confirmed in 81 (44.5 %) patients, with 70 suffering from vertebral fractures, which were multiple in 53 cases; 24 patients reported non-vertebral fractures. The mean spine TBS was 1.207 (1.187-1.228), and TBS Z-score was -1.86 (-2.07 to -1.65); area under the curve (AUC) was used to predict fracture (mean spine TBS) = 0.548 (95 % CI, 0.454-0.641)). In the final regression model, the only predictor of fracture occurrence was 24hUFC levels (p = 0.001), with an increase of 1.041 (95 % CI, 1.019-1.063), calculated for every 100 nmol/24-h cortisol elevation (AUC (24hUFC) = 0.705 (95 % CI, 0.629-0.782)). CONCLUSIONS: Young patients with CS have a low TBS. However, the only predictor of low traumatic fracture is the severity of the disease itself, indicated by high 24hUFC levels.
Resumo:
Le principal objectif de ce mémoire est l’étude de l’inscription de la maternité dans L’empreinte de l’ange, La virevolte et Prodige de Nancy Huston. Les trois romans précités constituent mon corpus de base. Néanmoins, des allusions à d’autres écrits de l’auteure, notamment à Journal de la création, donneront une plus grande profondeur à l’analyse, car on ne peut ni écarter les traces du thème de la maternité dans ses autres textes ni mésestimer l’influence de l’expérience de l’auteure sur son œuvre. Dans la foulée de la réflexion féministe contemporaine sur la maternité et faisant recours, selon le besoin, à la Nouvelle Histoire et à la psychanalyse, pour éclairer le contexte sociohistorique et le non-dit des textes, nous essaierons de dégager la singularité de l’écriture hustonienne en ce qui concerne ses idées sur la maternité. En effet, Nancy Huston s’inscrit dans la lignée d’écrivaines qui ont contribué à redéfinir l’identité féminine dans la fiction contemporaine en esquissant, à travers ses romans et essais, une multiplicité d’expériences féminines, toutes différentes, bien que plus ou moins soumises aux valeurs sociales dont l’auteure mesure la force. Nous abordons notre analyse par une mise en contexte historique, culturelle et éthique de la maternité. En effet, comme le thème de la maternité est omniprésent dans le discours social passé et contemporain, il est intéressent de voir comment Nancy Huston compose avec les stéréotypes traditionnellement attribués à la mère en suivant les enjeux, les conséquences et les variations de la maternité dans les œuvres à l’étude. Suivront à la mise en contexte historique et théorique les chapitres destinés à l’analyse des œuvres. Le deuxième chapitre portera sur L’empreinte de l’ange dévoilant les perplexités qui naissent d’une maternité non désirée et ombragée par les séquelles d’un passé tragique. Le troisième chapitre, consacré à l’analyse de La virevolte, s’articule autour de la tension entre la création et la procréation. Enfin, le quatrième et dernier chapitre aborde la maternité dans Prodige, roman où il est surtout question du lien entre emprise maternelle et construction de l’identité de la fille. À travers cette analyse, nous verrons comment Nancy Huston déconstruit le lieu commun voulant que la mère soit cet être idéalisé, privé de passions professionnelles et de pulsions artistiques, se dédiant uniquement à la protection et aux soins de l’enfant pour représenter plutôt des mères animées par des sentiments contradictoires, des mères qui se positionnent avant tout comme femmes sans inhiber leurs élans, leurs passions ni leurs tourments.
Resumo:
Objective: the goal of the present study was to evaluate the microleakage on the cementum/dentin and enamel surfaces in Class 11 restorations, using different kinds of resin composite (microhybrid, flowable, and compactable). Method and materials: Forty human caries-free molars were extracted and selected. Eighty Class 11 standardized cavities were made in the cervical wall at the cementoenamel junction (CEJ) and at the mesial and distal surfaces. The teeth were divided into four groups: G1 - adhesive system + microhybrid resin composite Z100; G2 - adhesive system + compactable resin composite Prodigy Condensable; G3 - adhesive system + flowable resin composite Revolution + Z1 00 resin composite; G4 - adhesive system + Revolution fluid resin + compactable resin composite Prodigy Condensable. The adhesive system used in this study was Scotchbond Multi-Purpose Plus. The specimens were thermocycled in baths of 5degreesC and 55degreesC for 1,000 cycles and immersed in 50% silver nitrate solution. The specimens then were sectioned and evaluated on degree of dye penetration. Results: the results were evaluated using the nonparametric Kruskall-Wallis test, which showed a statistically significant difference between groups G1 and G4, G2 and G4, and G3 and G4. Conclusions: None of the materials was able to eliminate the marginal microleakage at the cervical wall; the application of a low-viscosity resin composite combined with a compactable resin composite significantly decreased the microleakage.
Resumo:
Objective: The goal of the present study was to evaluate the microleakage on the cementum/dentin and enamel surfaces in Class II restorations, using different kinds of resin composite (microhybrid, flowable, and compactable). Method and materials: Forty human caries-free molars were extracted and selected. Eighty Class II standardized cavities were made in the cervical wall at the cementoenamel junction (CEJ) and at the mesial and distal surfaces. The teeth were divided into four groups: G1 - adhesive system + microhybrid resin composite Z100; G2 - adhesive system + compactable resin composite Prodigy Condensable; G3 - adhesive system + flowable resin composite Revolution + Z100 resin composite; G4 - adhesive system + Revolution fluid resin + compactable resin composite Prodigy Condensable. The adhesive system used in this study was Scotchbond Multi-Purpose Plus. The specimens were thermocycled in baths of 5°C and 55°C for 1,000 cycles and immersed in 50% silver nitrate solution. The specimens then were sectioned and evaluated on degree of dye penetration. Results: The results were evaluated using the nonparametric Kruskall-Wallis test, which showed a statistically significant difference between groups G1 and G4, G2 and G4, and G3 and G4. Conclusions: None of the materials was able to eliminate the marginal microleakage at the cervical wall; the application of a low-viscosity resin composite combined with a compactable resin composite significantly decreased the microleakage.
Resumo:
Modern restorative dentistry has been playing an outstanding role lately since composite resins, allied to adhesive systems, have been widely applied on anterior and posterior teeth restorations. The evolution of composite resins has mostly been verified due to the improvement of their aesthetic behavior and the increase in their compressive and abrasive strengths. In spite of these developments, the polymerization shrinkage inherent to the material has been a major deficiency that, so far, has been impossible to avoid. Using a gas pycnometry, this research investigated the polymerization shrinkage of three packable composite resins: Filtek P60 (3M), Prodigy Condensable (Kerr), and SureFil (Dentsply/Caulk), varying the distance from the light source to the surface of the resins (2 mm or 10 mm). The pycnometer Accupyc 1330 (Micromeritics, USA) precisely records helium displacement, allowing fast and reliable measurements of the volume of composite resin immediately before and after polymerization, without interference of temperature or humidity. Results were not found to be statistically different for the three tested resins, either for 2 mm or 10 mm-distance from the light source to the composite surface.
Resumo:
Purpose: The aim of this study was to evaluate the surface roughness of four packable composite resins, SureFil™ (Dentsply, Petrópolis, Rio de Janeiro, Brazil), Prodigy Condensable™ (Kerr Co., Orange, CA, USA), Filtek P60™ (3M do Brasil, São Paulo, Brazil), and ALERT® (Jeneric/Pentron, Inc., Wallingford, CT, USA) and one microhybrid composite resin (Filtek Z250™, 3M do Brasil) after polishing with four finishing systems. Materials and Methods: Twenty specimens were made of each material (5 mm in diameter and 4 mm high) and were analyzed with a profilometer (Perthometer® S8P, Perthen, Mahr, Germany) to measure the mean surface roughness (Ra). The specimens were then divided into four groups according to the polishing system: group 1 - Sof-Lex™ (3M do Brasil), group 2 - Enhance™ (Dentsply), group 3 - Composite Finishing Kit (KG Sorensen, Barueri, São Paulo, Brazil), and group 4 - Jiffy Polisher Cups® (Ultradent Products, Inc., South Jordan, UT, USA). The specimens were polished and then evaluated for Ra, and the data were subjected to analysis of variance, analysis of covariance, and Tukey's test (p = .05). Results: The mean Ra of SureFil polished with Sof-Lex was significantly lower than that of KG points. Prodigy Condensable polished with Enhance showed a significantly less rough surface than when polished with Sof-Lex. Filtek P60 did not exhibit a significant difference with the various polishing systems. For ALERT the lowest mean Ra was obtained with Sof-Lex and the highest mean Ra with KG points. Regarding Filtek Z250, polishing with KG and Jiffy points resulted in a significantly lower mean Ra than when polished with Enhance. Conclusions: Packable composite resins display variable roughness depending on the polishing system used; the Sof-Lex disks and Jiffy points resulted in the best Ra values for the majority of the materials tested.
Resumo:
Objective: This study evaluated the effectiveness of proximal contacts in Class II restorations using two types of matrix bands (steel and polyester) with two different restoration techniques (incremental and with prepolymerized particles). Method and materials: Eighty-eight Class II adjacent restorations using Prodigy resin composite were performed: 44 with the incremental technique (22 with steel matrix bands, 22 with polyester matrix bands) and 44 utilizing prepolymerized resin particles (22 steel matrix, 22 polyester matrix). The restorations were clinically evaluated at baseline and at 6, 12, and 18 months. Proximal contacts obtained immediately after restoration procedure in all restorations were satisfactory. Results: No statistically significant alterations were found in 18 months of evaluation. Conclusion: Regardless of the utilized resin composite, there were no differences in the amount of proximal contact variations with respect to tested techniques and matrices.
Resumo:
OBJECTIVE: This study evaluated the efficiency of repolishing, sealing with surface sealant, and the joining of both in decreasing the surface roughness of resin-based composites after a toothbrushing process. METHOD AND MATERIALS: Ten specimens of each composite (Alert, Z100, Definite, and Prodigy Condensable), measuring 2 mm in thickness and 4 mm in diameter, were made and submitted to finishing and polishing processes on both sides of the specimens using the Sof-Lex system. The specimens were then subjected to toothbrushing (30,000 cycles), and surface roughness (Ra) was analyzed with a Surfcorder SE 1700 profilometer. The upper surface of each composite was etched with 37% phosphoric acid, and the surface-penetrating sealant Protect-it was applied on 1 surface. The roughness of these surfaces was again measured. On the other side, the surface of the specimen was repolished, and the efficiency of this procedure was measured using the profilometer. The surface roughness resulting from the joining of the 2 methods was verified by applying, in the final stage, the surface-penetrating sealant on the repolished surface. Data were analyzed with analysis of variance and Tukey test (P <.05). RESULTS: Results showed that the lowest surface roughness values were obtained for Definite, Z100, and Prodigy Condensable after the repolishing process and after the repolishing plus sealing. For Alert, the joining of repolishing plus sealing promoted the lowest values of surface roughness. CONCLUSION: Of the resin-based composites, Alert demonstrated the highest values of surface roughness in all the techniques tested.