968 resultados para Processo oxidativo avançado
Resumo:
The oil and petrochemical industry is responsable to generate a large amount of waste and wastewater. Among some efluents, is possible find the benzene, toluene, ethilbenze and isomers of xilenes compounds, known as BTEX. These compounds are very volatily, toxic for environment and potencially cancerigenous in man. Oxidative advanced processes, OAP, are unconventional waste treatment, wich may be apply on treatment and remotion this compounds. Fenton is a type of OAPs, wich uses the Fenton s reactant, hydrogen peroxide and ferrous salt, to promove the organic degradation. While the Photo-Fenton type uses the Fenton s reactant plus UV radiation (ultraviolet). These two types of OAP, according to literature, may be apply on BTEX complex system. This project consists on the consideration of the utilization of technologies Fenton and Photo-Fenton in aqueous solution in concentration of 100 ppm of BTEX, each, on simulation of condition near of petrochemical effluents. Different reactors were used for each type of OAP. For the analyticals results of amount of remotion were used the SPME technique (solid phase microextraction) for extraction in gaseous phase of these analytes and the gas chromatography/mass espectrometry The arrangement mechanical of Photo-Fenton system has been shown big loss by volatilization of these compounds. The Fenton system has been shown capable of degradate benzene and toluene compounds, with massic percentage of remotion near the 99%.
Resumo:
The soil contamination with petroleum is one of the major concern of industries operating in the field and also of environmental agencies. The petroleum consists mainly of alkanes and aromatic hydrocarbons. The most common examples of hydrocarbons polyaromatic are: naphthalene, anthracene, phenanthrene, benzopyrene and their various isomers. These substances cause adverse effects on human and the environment. Thus, the main objective of this work is to study the advanced oxidation process using the oxidant potassium permanganate (KMnO4) for remediation of soils contaminated with two polyaromatic hydrocarbons (PAHs): anthracene and phenanthrene. This study was conducted at bench scale, where the first stage was at batch experiment, using the variables: the time and oxidant dosage in the soil. The second stage was the remediation conducted in continous by a fix column, to this stage, the only variable was remediation time. The concentration of oxidant in this stage was based on the best result obtained in the tests at batch, 2,464 mg / L. The results of degradation these contaminants were satisfactory, at the following dosages and time: (a) 5g of oxidant per kg soil for 48 hours, it was obtained residual contaminants 28 mg phenanthrene and 1.25 mg anthracene per kg of soil and (b) for 7g of oxidant per kg soil in 48 hours remaining 24 mg phenanthrene and anthracene 0.77 mg per kg soil, and therefore below the intervention limit residential and industrial proposed by the State Company of Environmental Sao Paulo (CETESB)
Remediação de solos e lençóis freáticos em postos de gasolina via processo de fenton: estudo de caso
Resumo:
Alguns cientistas ambientais prevêem que a poluição dos solos será um dos maiores legados com grandes impactos para as gerações futuras, pois atualmente ainda existe desconhecimento das fontes poluidoras e da sua extensão. O Brasil, devido a sua extensão territorial, suas bacias hidrográficas, número de postos de abastecimentos e controles ambientais ainda ineficazes, está muito exposto a esse tipo de poluição. Atualmente, há no Brasil mais de 34.300 postos de combustíveis, com volume de 65.000.000 m3 de gasolina e diesel consumidos anualmente, conforme dados da Agência Nacional do Petróleo Gás Natural e Biocombustíveis , ANP, em 2008. Sendo assim, a exposição e contaminação dos solos e dos lençóis freáticos com constituintes aromáticos do diesel e gasolina torna-se um sério problema ambiental. Dentro deste grupo, encontram-se o benzeno, tolueno, xileno, conhecido como BTEX e os hidrocarbonetos policíclicos aromáticos, conhecido como PAH. Este trabalho tem como objetivo estudar a remediação in-situ de um posto de combustíveis na região do ABC Paulista, no Estado de São Paulo. Aplicando-se a técnica de Processo Oxidativo Avançado via reagente de Fenton (H2O2 + Fe2+ → Fe3+ + OH- + OH . ), o radical hidroxila gerado mineraliza compostos aromáticos, decompondo-os definitivamente. Amostras de água do posto em estudo apresentavam elevados teores de BTEX e PAH, 2,58 mg.L-1 e 0,298 mg.L-1 respectivamente, estando em níveis não tolerados pelo órgão ambiental paulista CETESB sendo necessária a intervenção para tratamento da área. Com os níveis de poluentes e o perfil hidrogeológico identificados, a remediação foi iniciada com injeções no solo de peróxido de hidrogênio a 8%v.v, FeSO4 a 0,40 mg.L-1 e solução à base de NPK (nitrogênio, fósforo e nitrogênio) a 100 mg.L-1 como nutrientes para os microorganismos do solo. Estes valores são provenientes de experimentos anteriores e tratamentos já realizados. Foram conduzidas campanhas de injeção trimestrais com 100 litros desta solução completa como reagente , e medições trimestrais de BTEX, PAH e outros parâmetros de controle, que foram indicando o sucesso do tratamento. Após 18 meses o local foi considerado tratado pelo órgão ambiental, onde monitoramentos semestrais estão em continuidade para garantir o resultado do tratamento e das ações corretivas. Assim, o estudo real da remediação de solos contaminados com os poluentes orgânicos via processo de Fenton, com concentração de H2O2 a 8%v/v, e FeSO4 a 0,40 mg.L-1 demonstrou-se uma técnica de sucesso. O entendimento dos resultados da remediação, mesmo sujeitos aos fenômenos naturais, como intempéries e chuvas, é uma experiência grande, pois por mais reais que simulações em laboratório possam ser, é muito difícil incluir nestes sistemas, as variações que um tratamento real está exposto
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
At the cashew nut processing industry it is often the generation of wastewaters containing high content of toxic organic compounds. The presence of these compounds is due mainly to the so called liquid of the cashew nut (CNSL). CNSL, as it is commercially known in Brazil, is the liquid of the cashew nut. It looks like an oil with dark brown color, viscous and presents a high toxicity index due to the chemical composition, i.e. phenol compounds, such as anacardic acid, cardol, 2-methyl cardol and monophenol (cardanol). These compounds are bio resistant to the conventional treatments. Furthermore, the corresponding wastewaters present high content of TOC (total organic carbon). Therefore due to the high degree of toxicity it is very important to study and develop treatments of these wastewaters before discharge to the environmental. This research aims to decompose these compounds using advanced oxidative processes (AOP) based on the photo-Fenton system. The advantage of this system is the fast and non-selective oxidation promoted by the hydroxyl radicals (●OH), that is under determined conditions can totally convert the organic pollutants to CO2 and H2O. In order to evaluate the decomposition of the organic charge system samples of the real wastewater od a processing cashew nut industry were taken. This industry was located at the country of the state of Rio Grande do Norte. The experiments were carried out with a photochemical annular reactor equipped with UV (ultra violet) lamp. Based on preliminary experiments, a Doehlert experimental design was defined to optimize the concentrations of H2O2 and Fe(II) with a total of 13 runs. The experimental conditions were set to pH equal to 3 and temperature of 30°C. The power of the lamps applied was 80W, 125W and 250W. To evaluate the decomposition rate measures of the TOC were accomplished during 4 hours of experiment. According to the results, the organic removal obtained in terms of TOC was 80% minimum and 95% maximum. Furthermore, it was gotten a minimum time of 49 minutes for the removal of 30% of the initial TOC. Based on the obtained experimental results, the photo-Fenton system presents a very satisfactory performance as a complementary treatment of the wastewater studied
Resumo:
One of the main impacts to the environment is the water pollution, where the industrial sector is one of the main sources of this problem. In order to search for a solution, the industrial sector is looking forward to new technologies to treat its wastewaters with the goal to reuse the water in the own process. In this mode, the treatment presents a reduction in its costs with the water suply. One of these technologies that are getting more and more applications is the advanced oxidative processes (AOP´s). In this work two industrial wastewaters have been studied, i.e., containing polymers and pharmacus. In the case of the wastewaters with polymers the UV/H2O2 process has been applied with a systematic series of experiments, using irradiation from a mercury lamp and also solar. The following variables of the UV/H2O2 process for the polymers wastewaters have been studied systematically with the lamp reactor: mode of addition of hydrogen peroxide, temperature, time of reaction, hydrogen peroxide concentration and power of the lamp (80, 125, 250 and 400W). The results demonstrated to be satisfactory, obtaining rates of organic charge removal of 100% in 120 minutes of reaction. The studied variables for the experiments with solar irradiation using polymers wastewaters were only the time of reaction, the mode of addition and concentration of the hydrogen peroxide. The results with the solar irradiation demonstrated to be not satisfactory, reaching maximum of 22% of TOC removal in 240 minutes of reaction. This is in accordance with the fact that the solar source has only 5% of low UV irradiation. With respect to the photodegradation of the pharmacus wastewaters, the process UV/H2O2 and photo-Fenton have been applied. As a source of photons, in this case, a mercury UV lamp of 80 W has been used. The studied variables for the experiments with artificial irradiation with the pharmacus wastewaters were: initial concentration of the pollutant, concentration of Fe2+ and time of reaction. The results demonstrated a degree of degradation fairly satisfactory, showing a maximum conversion value of 46% in 120 minutes
Resumo:
The aim of the present study was to extract vegetable oil from brown linseed (Linum usitatissimum L.), determine fatty acid levels, the antioxidant capacity of the extracted oil and perform a rapid economic assessment of the SFE process in the manufacture of oil. The experiments were conducted in a test bench extractor capable of operating with carbon dioxide and co-solvents, obeying 23 factorial planning with central point in triplicate, and having process yield as response variable and pressure, temperature and percentage of cosolvent as independent variables. The yield (mass of extracted oil/mass of raw material used) ranged from 2.2% to 28.8%, with the best results obtained at 250 bar and 50ºC, using 5% (v/v) ethanol co-solvent. The influence of the variables on extraction kinetics and on the composition of the linseed oil obtained was investigated. The extraction kinetic curves obtained were based on different mathematical models available in the literature. The Martínez et al. (2003) model and the Simple Single Plate (SSP) model discussed by Gaspar et al. (2003) represented the experimental data with the lowest mean square errors (MSE). A manufacturing cost of US$17.85/kgoil was estimated for the production of linseed oil using TECANALYSIS software and the Rosa and Meireles method (2005). To establish comparisons with SFE, conventional extraction tests were conducted with a Soxhlet device using petroleum ether. These tests obtained mean yields of 35.2% for an extraction time of 5h. All the oil samples were sterilized and characterized in terms of their composition in fatty acids (FA) using gas chromatography. The main fatty acids detected were: palmitic (C16:0), stearic (C18:0), oleic (C18:1), linoleic (C18:2n-6) and α-linolenic (C18:3n-3). The FA contents obtained with Soxhlet dif ered from those obtained with SFE, with higher percentages of saturated and monounsaturated FA with the Soxhlet technique using petroleum ether. With respect to α-linolenic content (main component of linseed oil) in the samples, SFE performed better than Soxhlet extraction, obtaining percentages between 51.18% and 52.71%, whereas with Soxhlet extraction it was 47.84%. The antioxidant activity of the oil was assessed in the β-carotene/linoleic acid system. The percentages of inhibition of the oxidative process reached 22.11% for the SFE oil, but only 6.09% for commercial oil (cold pressing), suggesting that the SFE technique better preserves the phenolic compounds present in the seed, which are likely responsible for the antioxidant nature of the oil. In vitro tests with the sample displaying the best antioxidant response were conducted in rat liver homogenate to investigate the inhibition of spontaneous lipid peroxidation or autooxidation of biological tissue. Linseed oil proved to be more efficient than fish oil (used as standard) in decreasing lipid peroxidation in the liver tissue of Wistar rats, yielding similar results to those obtained with the use of BHT (synthetic antioxidant). Inhibitory capacity may be explained by the presence of phenolic compounds with antioxidant activity in the linseed oil. The results obtained indicate the need for more detailed studies, given the importance of linseed oil as one of the greatest sources of ω3 among vegetable oils
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A amônia é considerada uma substância poluente em água. A legislação permite uma concentração máxima de 5,0 mg/L de amônia em efluentes industriais. Como vários processos industriais geram rejeitos com concentrações bem mais elevadas de amônia do que este limite, este trabalho visa estudar a utilização do ácido de caro na degradação da amônia nesses efluentes. O ácido sulfúrico em presença de peróxido de hidrogênio apresenta alto poder oxidativo. Sob determinadas condições, este ácido pode oxidar a amônia a nitrato. O trabalho teve como objetivo principal o estudo das variáveis dessa reação tais como tempo, concentração de reagentes, catalisadores, a fim de aperfeiçoar o processo de degradação. Utilizou-se amostra de efluente sintético contendo amônia na faixa de 20-40 mg/L e no processo de degradação foram variados parâmetros tais como o metal utilizado como catalisador (Cu2+, Fe2+, Co2+ e Mo6+), a concentração desses catalisadores, a temperatura do processo de degradação e razão molar H2SO5:NH3. No trabalho, foi observado que a degradação de amônia com ácido de caro catalisado com cobalto (II) foi a que apresentou melhores resultados. O ácido de caro mostrou ser mais eficiente nas seguintes condições: [Co2+] = 2 mg/L, pH = 9, H2SO5:NH3 = 6,25:1, temperatura = 40 C, o que levou a valores de amônia abaixo de 0,1 mg/L em apenas 60 minutos de um efluente sintético com amônia aproximadamente 25 mg/L. A utilização de cobalto como catalisador diminui a quantidade de ácido de caro necessário no processo oxidativo além de não ter limite para descarte de cobalto em efluentes industriais
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)