969 resultados para Precise Surveying
Resumo:
OBJECTIVE: The aim of the present study was to verify the torque precision of metallic brackets with MBT prescription using the canine brackets as the representative sample of six commercial brands. MATERIAL AND METHODS: Twenty maxillary and 20 mandibular canine brackets of one of the following commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP Orthodontics, Morelli and Ortho Organizers. The torque angle, established by reference points and lines, was measured by an operator using an optical microscope coupled to a computer. The values were compared to those established by the MBT prescription. RESULTS: The results showed that for the maxillary canine brackets, only the Morelli torque (-3.33º) presented statistically significant difference from the proposed values (-7º). For the mandibular canines, American Orthodontics (-6.34º) and Ortho Organizers (-6.25º) presented statistically significant differences from the standards (-6º). Comparing the brands, Morelli presented statistically significant differences in comparison with all the other brands for maxillary canine brackets. For the mandibular canine brackets, there was no statistically significant difference between the brands. CONCLUSIONS: There are significant variations in torque values of some of the brackets assessed, which would clinically compromise the buccolingual positioning of the tooth at the end of orthodontic treatment.
Resumo:
We present a new set of oscillator strengths for 142 Fe II lines in the wavelength range 4000-8000 angstrom. Our gf-values are both accurate and precise, because each multiplet was globally normalized using laboratory data ( accuracy), while the relative gf-values of individual lines within a given multiplet were obtained from theoretical calculations ( precision). Our line list was tested with the Sun and high-resolution (R approximate to 10(5)), high-S/N (approximate to 700-900) Keck+HIRES spectra of the metal-poor stars HD 148816 and HD 140283, for which line-to-line scatter (sigma) in the iron abundances from Fe II lines as low as 0.03, 0.04, and 0.05 dex are found, respectively. For these three stars the standard error in the mean iron abundance from Fe II lines is negligible (sigma(mean) <= 0.01 dex). The mean solar iron abundance obtained using our gf-values and different model atmospheres is A(Fe) = 7.45(sigma = 0.02).
Resumo:
We present precise tests of CP and CPT symmetry based on the full data set of K -> pi pi decays collected by the KTeV experiment at Fermi National Accelerator Laboratory during 1996, 1997, and 1999. This data set contains 16 x 10(6) K -> pi(0)pi(0) and 69 x 10(6) K -> pi(+)pi(-) decays. We measure the direct CP violation parameter Re(epsilon'/epsilon) = (19.2 +/- 2.1) x 10(-4). We find the K(L) -> K(S) mass difference Delta m = (5270 +/- 12) x 10(6) (h) over tilde s(-1) and the K(S) lifetime tau(S) = (89.62 +/- 0.05) x 10(-12) s. We also measure several parameters that test CPT invariance. We find the difference between the phase of the indirect CP violation parameter epsilon and the superweak phase: phi(epsilon) - phi(SW) =(0.40 +/- 0.56)degrees. We measure the difference of the relative phases between the CP violating and CP conserving decay amplitudes for K -> pi(+)pi(-) (phi(+-)) and for K -> pi(0)pi(0) (phi(00)): Delta phi = (0.30 +/- 0.35)degrees. From these phase measurements, we place a limit on the mass difference between K(0) and (K) over bar (0): Delta M < 4.8 x 10(-19) GeV/c(2) at 95% C.L. These results are consistent with those of other experiments, our own earlier measurements, and CPT symmetry.
Resumo:
Finite-size scaling analysis turns out to be a powerful tool to calculate the phase diagram as well as the critical properties of two-dimensional classical statistical mechanics models and quantum Hamiltonians in one dimension. The most used method to locate quantum critical points is the so-called crossing method, where the estimates are obtained by comparing the mass gaps of two distinct lattice sizes. The success of this method is due to its simplicity and the ability to provide accurate results even considering relatively small lattice sizes. In this paper, we introduce an estimator that locates quantum critical points by exploring the known distinct behavior of the entanglement entropy in critical and noncritical systems. As a benchmark test, we use this new estimator to locate the critical point of the quantum Ising chain and the critical line of the spin-1 Blume-Capel quantum chain. The tricritical point of this last model is also obtained. Comparison with the standard crossing method is also presented. The method we propose is simple to implement in practice, particularly in density matrix renormalization group calculations, and provides us, like the crossing method, amazingly accurate results for quite small lattice sizes. Our applications show that the proposed method has several advantages, as compared with the standard crossing method, and we believe it will become popular in future numerical studies.
Resumo:
An investigation was undertaken to test the effectiveness of two procedures for recording boundaries and plot positions for scientific studies on farms on Leyte Island, the Philippines. The accuracy of a Garmin 76 Global Positioning System (GPS) unit and a compass and chain was checked under the same conditions. Tree canopies interfered with the ability of the satellite signal to reach the GPS and therefore the GPS survey was less accurate than the compass and chain survey. Where a high degree of accuracy is required, a compass and chain survey remains the most effective method of surveying land underneath tree canopies, providing operator error is minimised. For a large number of surveys and thus large amounts of data, a GPS is more appropriate than a compass and chain survey because data are easily up-loaded into a Geographic Information System (GIS). However, under dense canopies where satellite signals cannot reach the GPS, it may be necessary to revert to a compass survey or a combination of both methods.
Resumo:
A precise, reproducible deletion made during in vitro reverse transcription of RNA2 from the icosahedral positive-stranded Helicoverpa armigera stunt virus (Tetraviridae) is described. The deletion, located between two hexamer repeats, is a 50-base sequence that includes one copy of the hexamer repeat. Only the Moloney murine leukemia virus reverse transcriptase and its derivative Superscript I, carrying a deletion of the carboxy-terminal RNase H region, showed this response, indicating a template-switching mechanism different from one proposed that involves a RNase H-dependent strand transfer, Superscript II, however, which carries point mutations to reduce RNase H activity, does not cause a deletion. A possible mechanism involves the enzyme pausing at the 3' side of a stem-loop structure and the 3' end of the nascent DNA strand separating from the template and reannealing to the upstream hexamer repeat.
Resumo:
Objective: To evaluate the impact of systematic use of intraoperative Doppler ultrasound during microsurgical subinguinal varicocele repair. Design: Prospective clinical study. Setting: Andrology laboratory and male infertility section of the urology department of a tertiary care hospital. Patient(s): Two hundred and thirteen men with clinical varicocele. Intervention(s): Subinguinal microsurgical varicocele ligation using an intraoperative vascular Doppler flow detector. Main Outcome Measure(s): Number of veins ligated, lymphatic spared, arteries identified or accidentally ligated. Result(s): A statistically significant greater number of arteries were identified and preserved when intraoperative vascular Doppler was used. In addition, the average number of internal spermatic veins ligated was statistically significantly greater in the same group. Accidental artery ligation occurred in two cases (1.1%) in which the Doppler was not applied. There was no statistically significant difference in number of lymphatics spared between groups. Conclusion(s): Our findings showed that concomitant use of intraoperative vascular Doppler during microsurgical varicocelectomy allows more arterial branches to be preserved, and more internal spermatic veins are likely to be ligated. This device should be considered an attractive tool to improve surgical outcomes and safety. (Fertil Steril (R) 2010; 93: 2396-9. (C)2010 by American Society for Reproductive Medicine.)
Resumo:
The Drosophila roughest (rst) locus encodes an immunoglobulin superfamily transmembrane glycoprotein implicated in a variety of embryonic and postembryonic developmental processes. Here we demonstrate a previously unnoticed role for this gene in the autophagic elimination of larval salivary glands during early pupal stages by showing that overexpression of the Rst protein ectodomain in early pupa leads to persistence of salivary glands up to at least 12 hours after head eversion, although with variable penetrance. The same phenotype is observed in individuals carrying the dominant regulatory allele rst(D), but not in loss of function alleles. Analysis of persistent glands at the ultrastructural level showed that programmed cell death starts at the right time but is arrested at an early stage of the process. Finally we describe the expression pattern and intracellular distribution of Rst in wild type and rstD mutants, showing that its downregulation in salivary glands at the beginning of pupal stage is an important factor in the correct implementation of the autophagic program of this tissue in space and time. genesis 47:492-504, 2009. (C) 2009 Wiley-Liss, Inc.
Resumo:
Purpose: Orthodontic miniscrews are commonly used to achieve absolute anchorage during tooth movement. One of the most frequent complications is screw loss as a result of root contact. Increased precision during the process of miniscrew insertion would help prevent screw loss and potential root damage, improving treatment outcomes. Stereo lithographic surgical guides have been commonly used for prosthetic implants to increase the precision of insertion. The objective of this paper was to describe the use of a stereolithographic surgical guide suitable for one-component orthodontic miniscrews based on cone beam computed tomography (CBCT) data and to evaluate implant placement accuracy. Materials and Methods: Acrylic splints were adapted to the dental arches of four patients, and six radiopaque reference points were filled with gutta-percha. The patients were submitted to CBCT while they wore the occlusal splint. Another series of images was captured with the splint alone. After superimposition and segmentation, miniscrew insertion was simulated using planning software that allowed the user to check the implant position in all planes and in three dimensions. In a rapid-prototyping machine, a stereolithographic guide was fabricated with metallic sleeves located at the insertion points to allow for three-dimensional control of the pilot bur. The surgical guide was worn during surgery. After implant insertion, each patient was submitted to CBCT a second time to verify the implant position and the accuracy of the placement of the miniscrews. Results: The average differences between the planned and inserted positions for the ten miniscrews were 0.86 mm at the coronal end, 0.71 mm at the center, and 0.87 mm at the apical tip. The average angular discrepancy was 1.76 degrees. Conclusions: The use of stereolithographic surgical guides based on CBCT data allows for accurate orthodontic mini screw insertion without damaging neighboring anatomic structures. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:860-865
Resumo:
A combined procedure for separating Lu, Hf, Sm, Nd, and rare earth elements (REEs) from a single sample digest is presented. The procedure consists of the following five steps: (1) sample dissolution via sodium peroxide sintering; (2) separation of the high field strength elements from the REEs and other matrix elements by a HF-free anion-exchange column procedure; (3) purification of Hf on a cation-exchange resin; (4) separation of REEs from other matrix elements by cation exchange; (5) Lu, Sm, and Nd separation from the other REEs by reversed-phase ion chromatography. Analytical reproducibilities of Sm-Nd and Lu-Hf isotope systematics are demonstrated for standard solutions and international rock reference materials. Results show overall good reproducibilities for Sm-Nd systematics independent of the rock type analyzed. For the Lu-Hf systematics, the reproducibility of the parent/daughter ratio is much better for JB-1 (basalt) than for two analyzed felsic crustal rocks (DR-N and an Archaean granitoid). It is demonstrated that this poorer reproducibility of the Lu/Hf ratio is truly caused by sample heterogeneity; thus, results are geologically reasonable.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
CISTI'2015 - 10ª Conferência Ibérica de Sistemas e Tecnologias de Informação, 17 a 20 de junho de 2015, Águeda, Aveiro, Portugal.
Resumo:
The goal of the work presented in this paper is to provide mobile platforms within our campus with a GPS based data service capable of supporting precise outdoor navigation. This can be achieved by providing campus-wide access to real time Differential GPS (DGPS) data. As a result, we designed and implemented a three-tier distributed system that provides Internet data links between remote DGPS sources and the campus and a campus-wide DGPS data dissemination service. The Internet data link service is a two-tier client/server where the server-side is connected to the DGPS station and the client-side is located at the campus. The campus-wide DGPS data provider disseminates the DGPS data received at the campus via the campus Intranet and via a wireless data link. The wireless broadcast is intended for portable receivers equipped with a DGPS wireless interface and the Intranet link is provided for receivers with a DGPS serial interface. The application is expected to provide adequate support for accurate outdoor campus navigation tasks.
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2015
Resumo:
Report for the scientific sojourn at the German Aerospace Center (DLR) , Germany, during June and July 2006. The main objective of the two months stay has been to apply the techniques of LEO (Low Earth Orbiters) satellites GPS navigation which DLR currently uses in real time navigation. These techniques comprise the use of a dynamical model which takes into account the precise earth gravity field and models to account for the effects which perturb the LEO’s motion (such as drag forces due to earth’s atmosphere, solar pressure, due to the solar radiation impacting on the spacecraft, luni-solar gravity, due to the perturbation of the gravity field for the sun and moon attraction, and tidal forces, due to the ocean and solid tides). A high parameterized software was produced in the first part of work, which has been used to asses which accuracy could be reached exploring different models and complexities. The objective was to study the accuracy vs complexity, taking into account that LEOs at different heights have different behaviors. In this frame, several LEOs have been selected in a wide range of altitudes, and several approaches with different complexity have been chosen. Complexity is a very important issue, because processors onboard spacecrafts have very limited computing and memory resources, so it is mandatory to keep the algorithms simple enough to let the satellite process it by itself.