885 resultados para Próteses parciais removíveis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The non-adaptation of the removable partial prosthesis (RPP) base to fibromucosal tissue is caused by resorption of residual ridges (RRR). The onset of bone resorption, which occurs after tooth extraction and continues throughout life, is accelerated by local or systemic factors. Aim: Assess the degree of non-adaptation of removable partial prosthesis saddles and the factors that influence it. Methodology: A sectional study was conducted with 81 patients using RPP who had their prostheses installed between 2003 and 2007 (1 to 5 years of use) at the Faculty of Dentistry of the Universidade Federal do Rio Grande do Norte (UFRN). After anamnese and clinical examination, a cast was made with polyether-based material, using the base of the prosthesis to make the impression. The base of the saddle was loaded with the casting material and positioned in the mouth, applying pressure on the supports. After polymerization, the material was removed from the saddle and measurements were taken at 3 different points using a pachymeter. Results: The non-adaptation of the saddle increased significantly with years of use (p = 0.005). The tooth-tissue supported prostheses obtained higher mean non-adaptation values than those of tooth supported prostheses (p < 0.001). Flaccid mucosa showed the worst non-adaptation results, which were statistically different from resilient mucosa (p < 0.001). The greater the extension of the saddle, the greater the non-adaptation (p < 0.001). The natural tooth antagonistic arch yielded better results than did RPP and total prosthesis (p < 0.001). Saddle non-adaptation at the free end was less near the pillar tooth and greater in the more posterior region (p < 0.001). When adaptation of the supports to the niches was poor, greater saddle non-adaptation occurred than when it was good or fair (p < 0.001). Saddles located in the posterior region of the arch had greater non-adaptation than those in the anterior region (p = 0.023). Conclusion: The mean non-adaptation of the saddle to the residual ridges was 0.27 mm. It can be concluded that, even with the use of RPP, bone height reduction was slight within the 1-5-year period of use. The following are factors that influence adaptation of the RPP saddle base: years of use, age, force transmission path to the alveolar bone, location of the toothless area, antagonistic arch, type of mucosa, adaptation of supports to the niche and extension of the saddle

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The literature has shown a relation between periodontics and the removable partial denture (RPD), with progressive destruction observed in the support structures. The aim of this study was to clinically assess periodontal condition in users of removal partial denture (RPD), and compare right abutments teeth, indirect abutments and controls before installation and after 1 year, in addition to comparing tooth-supported and tooth mucosa-supported abutments. A total of 50 patients, 32 women and 18 men, mean age of 45 years, took part in the study. The patients were examined by a single examiner at prosthesis installation and after 3, 6, 9 and 12 months. The following were verified at each examination: Probe Depth (PD), Plaque Index (PI), Gingival Index (GI), the amount of Keratinized Mucosa (KM), Gingival Recession (GR) and Dental Mobility (DM); in addition patients received oral hygiene orientation, accompanied by prophylaxis, periodontal scaling and root planing (PSRP), when necessary. Analysis of Variance (ANOVA) with Tukey-Kramer post test was used to assess the dependent variables (PD, PI, KM, GR) of the three groups over time while Friedman s test was used for GI. To assess the outcomes of prosthesis type in the right abutment group, a confidence interval-based analysis was performed. The results showed that the control group was the least compromised in all the variables studied. With respect to development of the groups over time, it was verified that the measures for GR, PD, GI and KM increased from initial examination to 1 year of use in all the groups, but only PI showed a significant increase. There was a non-discriminatory low prevalence of dental mobility. The tooth mucosa-supported prosthesis had significantly higher values for GR, GI and PI and significantly lower ones for KM when compared to tooth-supported. Over time, both types of prostheses showed no significant differences from initial to final examination for the variables GR, PD, KM and GI, with PI significant only for tooth-supported. The results showed that the teeth most involved in RPD design had greater potential of periodontal damage, probably because of greater dental biofilm accumulation. Abutments elements adjacent to the free extremities had less favorable periodontal condition than those adjacent to interpolated spaces, but the use of RPD did not worsen the initial condition

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A pesquisa teve como objetivo determinar as forças de mordida de 73 indivíduos, por meio de um gnatodinamômetro. Os pacientes eram portadores de próteses parciais removíveis inferiores classes I, II ou III. A arcada antagonista era prótese, parcial removível ou fixa, ou total. Os resultados permitiram concluir que: as selas de extremidade livre, principalmente em suas posições extremas, conduziram a forças de mordida muito baixas; o envolvimento de prótese total, também, conduziu a forças de mordida baixas; o sexo masculino alcançou valores maiores que o feminino; com prótese parcial removível classe III, os dentes naturais molares e pré-molares desenvolveram valores maiores do que com classes I e II.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Unilateral or bilateral distal-extension removable partial dentures present complex biomechanics. The movements in different directions, associated with the alveolar ridge shape and soft tissue resilience can lead to damaging forces on the supporting structures. The association between implants / removable partial denture aims to provide better mechanical and biological properties to the stomatognathic system. OBJECTIVE: The aim of this paper was to review the articles about the effect of implant support on distal extension removable partial dentures. LITERATURE REVIEW AND CONCLUSION: Studies have shown that this combination provides greater support, retention and stability to the prosthesis, thus limiting their approach movement toward supporting tissues and providing functional and psychological comfort to patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Unilateral or bilateral distal-extension removable partial dentures present complex biomechanics. The movements in different directions, associated with the alveolar ridge shape and soft tissue resilience can lead to damaging forces on the supporting structures. The association between implants / removable partial denture aims to provide better mechanical and biological properties to the stomatognathic system. Objective: The aim of this paper was to review the articles about the effect of implant support on distal extension removable partial dentures. Literature review and conclusion: Studies have shown that this combination provides greater support, retention and stability to the prosthesis, thus limiting their approach movement toward supporting tissues and providing functional and psychological comfort to patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays, the fixed partial dentures and/or dental implants is the most requested treatmentby the majority of partially edentulous patients. However, depending on the periodontal condition of the remaining teeth, as well as the bone condition of the prosthetic space, the oral rehabilitation with these treatments may be limited or even contraindicated. In such cases, the use of removable partial dentures associated to attachments becomes an important alternative for aesthetic and functional rehabilitation. Attachments are mechanical devices consisted of two parts (patrix-matrix), one placed inside another, which act as direct retainer, providing retention, support and stability to the dentures. These devices can be classified as intra or extracoronal attachments, considering their position in relation to the abutment tooth. However, regardless the type of attachment, the association between fixed and removable partial dentures should be performed respecting the biomechanical principles of both. Therefore, the purpose of this study was to review and discuss the literature about the clinical and laboratory implications of the association between fixed and removable partial dentures by means of attachments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect in the gingival tissue of four distinctive types of relationships between the major conector and the gingival margin was investigated in eight subjects in association with the experimental gingivitis model. The subjects wore appliances constructed in acrylic resin (retained by means of embrasure hooks) throughout the day an night, except during meals. After the appliances had been placed, the subjects were abstained from any oral hygiene for twenty-one days. Records of the Plaque Index, Gingival Index and probing deplh were taken at baseline and at each week. Data showed that there was a small increase in the Plaque Index and Gingival Index for the four areas and that the degree of inflammation of the covered areas was higher in the area without relief

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The free-end removable partial dentures (RPD) shows a complicated and peculiar biomechanical behavior that impose high occlusion forces to the abutment teeth. By this way, the aim of this study was to evaluate the several factors that influence the clasps indication to free-end RPD. It was analysed 84 designed and planned study models of 71 patients, involving 130 clasps near-by a free-end; followed by clinical and radiographical informations. It was observed that bar clasps (“T”, “Tmod”, “i”) were used in 88.46% of abutment teeth. In the others (11.55%), it was used simple, combinated or ring circumferential clasps, and MDL. In abutment teeth with high equator line the “i” clasps were predominant (48.48%). The “Tmod” clasps were predominant in abutment teeth with low equator line (50%) or in middle third (51.35%) and “T” clasps were predominant in inclined equators with mesio-buccal (56.52%) or disto-buccal (66.66%) retention. In the posterior abutment teeth, it was prevalent the distal rest (63.52%) and embracing to the adjacent tooth. Some others factors like long clinical crown (5.38%), wrong position of abutment teeth (4.61%), aesthetics (3.07%), retention in alveolar ridge (2.3%), fragility of abutment teeth (1.53%), short clinical crown (0.76%) and short space to the clasp (0.76%) influenced directly during the clasps selection. Factors like mobility of abutment teeth, height of muscular insertions, depth of buccal fornix and antagonist arch acted like secondary factors. After the informations analysis it may be concluded that the bar clasps with distal rest and embracing to the adjacent tooth were the most indicated to free-end RPD

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To perform a long-term clinical evaluation of the periodontium of removable parti al denture (RPD) wearers, comparing the direct pillar teeth of tooth-supported and toothtissue supported RPDs. Method: Fifty patients with mean age of 45 years were enrolled in the study. The individuals were examined by a single examiner at the moment of denture installation and after 3, 6, 9 and 12 months. In each exam, the following parameters were verified: gingival recession (GR), probing depth (PD), plaque index (PI), gingival index (GI) e amount kerati nized mucosa (KM). All patients received oral hygiene instructions and prophylaxis and, when necessary, scaling and root planing. An analysis from the confidence interval was done to evaluate the endpoints regarding the type of denture in the direct pillar group. Results: The tooth-tissue supported dentures showed significantly higher GR, GI and PI values, and significantly lower KM values. Over time, neither of the types of denture presented statistically significant difference from the initial to the final examination for the parameters GR, PD, KM and GI, while the PI was significant only for the tooth-supported dentures. Conclusion: Pillar teeth adjacent to free ends presented a less favorable periodontal conditi on than the pillar teeth adjacent to intercalated spaces. However, the use of RPD did not aggravate the initial condition, after a follow-up period of 12 months. The findings of the study indicate that, within 1 year, there were no significant differences between the direct pillars of the toothsupported and tooth-ti ssue supported dentures, and suggest the need of professional follow up for a longer period.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To perform a long-term clinical evaluation of the periodontium of removable parti al denture (RPD) wearers, comparing the direct pillar teeth of tooth-supported and toothtissue supported RPDs. Method: Fifty patients with mean age of 45 years were enrolled in the study. The individuals were examined by a single examiner at the moment of denture installation and after 3, 6, 9 and 12 months. In each exam, the following parameters were verified: gingival recession (GR), probing depth (PD), plaque index (PI), gingival index (GI) e amount kerati nized mucosa (KM). All patients received oral hygiene instructions and prophylaxis and, when necessary, scaling and root planing. An analysis from the confidence interval was done to evaluate the endpoints regarding the type of denture in the direct pillar group. Results: The tooth-tissue supported dentures showed significantly higher GR, GI and PI values, and significantly lower KM values. Over time, neither of the types of denture presented statistically significant difference from the initial to the final examination for the parameters GR, PD, KM and GI, while the PI was significant only for the tooth-supported dentures. Conclusion: Pillar teeth adjacent to free ends presented a less favorable periodontal conditi on than the pillar teeth adjacent to intercalated spaces. However, the use of RPD did not aggravate the initial condition, after a follow-up period of 12 months. The findings of the study indicate that, within 1 year, there were no significant differences between the direct pillars of the toothsupported and tooth-ti ssue supported dentures, and suggest the need of professional follow up for a longer period.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este protocolo objetiva esclarecer dúvidas existentes a respeito dos passos necessários para a reabilitação com próteses totais e parciais removíveis convencionais. Essas alternativas de tratamento são modalidades terapêuticas consagradas na literatura e podem devolver função mastigatória, estética, fonação e conforto ao paciente quando confeccionadas de maneira satisfatória. Elas representam também uma ótima opção para aqueles pacientes que não podem se submeter ao tratamento com implantes, por apresentarem limitações biológicas ou financeiras. A abordagem do protocolo clínico está dividida em duas partes. A primeira parte ilustra a reabilitação com próteses totais convencionais e a segunda, a reabilitação com próteses parciais removíveis convencionais em arcos inferiores com extremidade livre bilateral. Por meio da demonstração do passo a passo com fotos, dicas clínicas e resumos sistemáticos do conteúdo teórico contido nesse material, o aluno de Odontologia e o cirurgião-dentista poderão conhecer os passos necessários para executar estes tipos de reabilitações, desde o momento clínico de diagnóstico até o de controle e manutenção. Esperamos que essa obra desperte o interesse dos cirurgiões-dentistas por executar esses tipos de próteses e que os ajude a desenvolverem práticas e habilidades que melhorem o desempenho clínico dessas alternativas de tratamento.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este protocolo objetiva esclarecer dúvidas existentes a respeito dos passos necessários para a reabilitação com próteses totais e parciais removíveis convencionais. Essas alternativas de tratamento são modalidades terapêuticas consagradas na literatura e podem devolver função mastigatória, estética, fonação e conforto ao paciente quando confeccionadas de maneira satisfatória. Elas representam também uma ótima opção para aqueles pacientes que não podem se submeter ao tratamento com implantes, por apresentarem limitações biológicas ou financeiras. A abordagem do protocolo clínico está dividida em duas partes. A primeira parte ilustra a reabilitação com próteses totais convencionais e a segunda, a reabilitação com próteses parciais removíveis convencionais em arcos inferiores com extremidade livre bilateral. Por meio da demonstração do passo a passo com fotos, dicas clínicas e resumos sistemáticos do conteúdo teórico contido nesse material, o aluno de Odontologia e o cirurgião-dentista poderão conhecer os passos necessários para executar estes tipos de reabilitações, desde o momento clínico de diagnóstico até o de controle e manutenção. Esperamos que essa obra desperte o interesse dos cirurgiões-dentistas por executar esses tipos de próteses e que os ajude a desenvolverem práticas e habilidades que melhorem o desempenho clínico dessas alternativas de tratamento.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Para reabilitar a ausência de um elemento dentário posterior, as próteses parciais fixas (PPF) com retentores intracoronários são uma alternativa aos implantes osseointegrados. O objetivo deste estudo foi avaliar a distribuição de tensões nessas próteses com três combinações de materiais: cerâmica de zircônia parcialmente estabilizada por ítria (ZPEI) revestida por cerâmica de fluorapatita (α), cerâmica de dissilicato de lítio (β) ou compósito fibrorreforçado (γ). Na composição α, foram analisadas a presença ou ausência da cerâmica de revestimento na parede cervical das caixas proximais e três variações na área total da seção transversal dos conectores (4 mm de largura x 3,2, 4,2 ou 5,2 mm de altura). Em 8 modelos bidimensionais de elementos finitos, uma carga vertical de 500 N foi aplicada na fossa central do pôntico e as tensões principais máximas (tração) e mínimas (compressão) foram apontadas em MPa. Inicialmente foram avaliados os 6 modelos com PPF de ZPEI e suas variações. Os maiores valores das tensões de tração foram encontrados no terço cervical dos conectores. Quando presente nestas regiões, a cerâmica de revestimento recebeu tensões acima do limite de sua resistência à flexão. Na comparação entre os modelos sem cerâmica de revestimento na parede cervical das caixas proximais, mesmo aquele com conectores de 3,2 x 4 mm, cuja infraestrutura apresentava 2,5 x 3 mm, poderia ser recomendado para uso clínico. Altos valores de tensões de compressão foram registrados entre o terço oclusal e médio dos conectores, correspondente à união entre as cerâmicas, o que poderia ocasionar, devido à flexão, falhas adesivas. Posteriormente, o modelo de ZPEI com a cerâmica de fluorapatita ausente da parede cervical das caixas proximais e área total dos conectores de 4,2 x 4 mm foi comparado aos dois outros materiais com conectores de mesma área. Na PPF de dissilicato de lítio, os valores representaram uma provável violação do limite de sua resistência à flexão. A PPF de compósito fibrorreforçado apresentou tensões bem abaixo do limite de resistência à flexão de sua infraestrutura, mas, como no modelo de ZPEI, tensões compressivas se concentraram com alto valor entre o terço oclusal e médio dos conectores, local de união entre a resina composta e a infraestrutura de fibras. Os resultados mostraram que a cerâmica de dissilicato de lítio e a presença da cerâmica de fluorapatita na parede cervical das caixas proximais deveriam ser contraindicadas para a condição proposta. Parece viável uma área de conectores na infraestrutura de ZPEI com no mínimo 2,5 x 3 mm. A PPF de compósito fibrorreforçado apresenta resistência estrutural para a situação estudada, mas, como também aquelas compostas de ZPEI, aparenta ter como pontos fracos a adesão entre a infraestrutura e o material de cobertura e a própria resistência deste último.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Edentulous patients with complaint about mandibular conventional denture might experience poor masticatory function and negative impact of oral health on quality of life. The aim of this controlled clinical trial was to evaluate the effect of mandibular overdenture on oral health-related quality of life and masticatory efficacy in patients wearing mandibular complete dentures. The edentulous patients (n=16) were rehabilitated with new maxillary and mandibular complete dentures and, after 3 months, mandibular overdentures retained by 2 implants (bar-clip system) were fabricated. The Brazilian version of OHIP-Edent questionnaire was used to assess the oral healthrelated quality of life. Masticatory efficacy was evaluated through a colorimetric method with chewing capsules. The mean OHIP-Edent score was 8.5 with conventional dentures and 2.0 with mandibular overdenture, which means a positive impact of oral health on quality of life with overdentures (p=0.001). The mean absorbance for masticatory efficacy was 0.025 for conventional dentures and 0.073 for overdentures. There was statistically significant difference for masticatory efficacy before and after implants rehabilitation (p=0.003). However, there was no correlation between masticatory efficacy and OHIP (p>0.05). So, mandibular overdenture retained by 2 implants improved the quality of life and masticatory efficacy of edentulous patients with complaint about mandibular conventional complete dentures