863 resultados para Prótese parcial removível


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Even nowadays there is in Brasil a large number of edentulous and a precarious financial condition of most of the population. In addition, World Health Organization aims for oral health, which consists on the maintenance of a natural dentition, functional and aesthetic composed of at least 20 teeth, without need of prosthetic intervention throughout life. From this and considering the lack of researches about the permanence of edentulous spaces in the oral cavity, and also avoiding overtreatment, this research has been proposed. Thus, the aim was to evaluate the effect of different lengths of the shortened lower dental arch in the presence or absence of a removable partial denture (RPD) on masticatory function, quality of life and occurrence of temporomandibular dysfunction. To achieve this goal, we compared the masticatory efficiency (colorimetric test), the oral comfort through the analysis of the impact of oral health in quality of life (OHIP-14), the presence of temporomandibular dysfunction (RDC/TMD) and the general quality of life (WHOQOL) of patients with shortened dental arches (SDA) (n=60), which is an arch with a reduction of teeth starting posteriorly, and patients with complete dental arch (Complete DA) (n = 34). The group of patients whit SDA was divided among PPR wears (PPD + SDA) (n = 17) and non-wears (n = 43). The population of this study consisted on patients who received or looked for treatment at the clinics of the Department of Dentistry of UFRN, from clinical analysis and records. The sample was chosen by convenience. For statistical analysis, it was a database in SPSS 17.0, followed by descriptive analysis with frequencies, absolute values, tests of central tendency and variability. The statistical tests used were chi-squared and analysis of variance as well as Tukey s post test, when applicable, all with a 95% confidence level. The results shown a prevalence of TMD of 47,1% among patients using PRP and 69,8% among those who didn t, but this result wasn t statistically significant. The mean of the results of masticatory efficiency, WHOQOL and OHIP didn t show association to the presence or absence of PPR and to the lower number of occlusal units of the patients (0, 1, 2 or more occlusal). The association only occurred among the different groups of SDA and the patients with complete dental arch. Taking into account the results, it could be observed that studied patients with low posterior support using lower PRP didn t have better masticatory efficiency, general quality of life, less impacts of their oral conditions in quality of life or not even less temporomandibular dysfunction or better masticatory efficiency when compared to those who didn t use the prosthesis

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To determine the frequency and type of complications related to removable partial denture (RPD) less, Kennedy Class I, over time . Materials and Methods: This observational study consisted of a sample of 65 users PPR lower arches in Kennedy Class I and dentures, rehabilitated in the Department of Dentistry, Federal University of Rio Grande do Norte (UFRN). Patients were followed through periodic controls during periods of 60 days, 6 months and 1 year from installation. After the first year of control had other returns annually. The occurrence of complications or prosthetic failure was observed and recorded in a specific clinical record over 39 months. The patterns of failures observed were classified in the following situations: occurrence of traumatic ulcers after 2 months of installation, lack of retention, fracture or caries in the rest, fracture or dislocation of the artificial teeth, the larger connector fracture, fracture clip fracture support, poor support (need to reline the denture) and prosthesis fracture. Results: The incidence of complications was low frequency, being higher in the second year of use of the prosthesis. Among the complications that occurred more is the loss of retention (31.57%). Failures more severe and difficult to solve as the fracture elements of the metal structure of the PPR had low occurrence and were represented by only one case of the larger connector (5.3%) fractures. Conclusion: Removable partial dentures mandibular free end opposing of the conventional dentures have a low complication rate after 39 months of use when subjected to periodic controls

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors looked for the verification of the fatigue of retentive clasps utilized on the removable partial denture. According to this, it was idealized and built on assay machine, that through movements, simulate the insertion and removal of the clasp for a pattern tooth, manufactured on cobalt-chromium which has all the preparation normally utilized to the correct confection of this type of prosthesis. It was utilized three different commercial alloys based on cobalt-chromium: L1-Biosil; L2-Steldent; L3-Duracron. It was utilized the T clasp of Roach, with was tested upon three different proportions among width and thickness: E1-1.7;E2-2.0 and E3-2.3 and was casted through two casting techniques: F1-oxygen-gas and F2-oxygen-acetylene. The clasps were tested on the machine, which allowed the reading of the number of insertion and removal cycles made until fatigue appeared. The obtained results were submitted to the statistic analysis and the authors concluded that: a) L3 (Duracrom) obtained the best results followed by L1 (Biosil) and finally L3 (Steldent); b) among the analyzed thickness, the best results were obtained by E3, followed by E2 and after this E1; c) form the casting techniques, F2 gave us the best results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors tested the T clasp of Roach in three differents proportions among width and thickness: E1-1.7; E2-2.0 and E3-2.3, with a constant length of 15 mm. These clasps were casted with three cobalt-chromium alloys (L1-Biosil; L2-Steldent and L3-Duracrom), through two casting techniques (F1-oxygen-gas and F2-oxygen-acetylene). The fatigue of the clasps were verified by using and assay machine, that through movements, simulate the insertion and removal of the clasps for a pattern which were obtained from a premolar, prepared in a surveyor. This machine detect the fatigue of the clasps and count the number of cycles of insertion and removal realized. The obtained results of the interaction between the analysed factors, were submitted to the statistic analysis and the authors concluded that: a) the interaction of factors, Alloy x Thickness, Alloy x Casting Technique and Thickness x Casting Technique did not change the order of effects that the factors showed separately but gave rise to effects of different magnitude for any observed sense; b) the simultaneous interaction of the factors Alloy x Thickness x Casting Technique confirmed the superiority of the L3 alloy, the thickness E3 and the F2 casting technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Removable partial denture improve functional and aesthetic failures caused by partial loss of teeth, however specific characteristics of each patients can determine the success of treatment, especially with regard to the support of the prosthesis, which may depend on teeth, the combination of teehe and mucosa and currently associated with the dental implants. The aim of this study is report a case in which there was the need of the association, to enable better aesthetics and self-esteem to the patients. After implant placement and fabrication of prosthetic patient reported satisfaction with the rehabilitation treatment, improving their quality of life.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Maxillofacial deformities may cause awkward and embarrassing bearer. These patients present serious psychological, family and social issues becoming traumatized and complexed. These deformities can have congenital origin, malformations and developmental disorders, or can be caused by pathological mutilation such as necrotizing diseases and surgical oncology, or traumas such as traffic and work accidents.