979 resultados para Power profile


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Managers are central to any fuction in a complex and developed society. Their talents are reckoned to be cardinal in developed economies and a basic yearning of all developing economies.In order to survive and produce results in a turbulent and transient environment, the task is to understand the nature of factors contributing to managerial effectiveness. This study is an attempt towards this core issue of the present from a different perspective. This study tries to focus attention on a group of managers functioning in the field of banking, a core sector in the country's economy. The gamut of economic activities in Kerala being predominantly service-oriented, importance of commercial banking is almost indisputable. Though economists would argue that the disproportionate development of service sector is anomalous when viewed against the hazy scenarios in the primary and secondary sectors of the state’s economy, the extent and pace of growth in the banking sector has had its dole meted out by ambitious and productive managers fiinctioning in the field. Researcher’s attempt here is to thresh the grain and chaff among bank managers in terms of their effectiveness and to account for the variations in the light of their ability to affect the thoughts and actions of their subordinates. To put it succinctly, the attempt herein is to explain the effectiveness of bank managers in the light of their ‘Power Profile’ taken to be comprising Power Differentials, Power Bases, their Visibility and Credibility in the organisation and, the Power Styles typically used by them for influencing subordinates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Iterative multiuser joint decoding based on exact Belief Propagation (BP) is analyzed in the large system limit by means of the replica method. It is shown that performance can be improved by appropriate power assignment to the users. The optimum power assignment can be found by linear programming in most technically relevant cases. The performance of BP iterative multiuser joint decoding is compared to suboptimum approximations based on Interference Cancellation (IC). While IC receivers show a significant loss for equal-power users, they yield performance close to BP under optimum power assignment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is a paucity of evidence-based support for the allocation of rest interval duration between incremental loads in the assessment of the load-power profile. We examined the effect of rest interval duration on muscular power production in the load-power profile and sought to determine if greater rest is required with increasing load (i.e., variable rest interval). Ten physically trained men completed 4 experimental conditions in a crossover balanced design. Participants performed jump squats across incremental loads (0-60 kg) on 4 occasions, with an allocated recovery interval of 1, 2, 3, or 4 minutes. The mean log-transformed power output at each load was used for comparison between conditions (rest intervals). Unloaded jump squats (0 kg) maximized power output at each condition. The maximal mechanical power output was 66.6 ± 6.5 W·kg (1 minute), 66.2 ± 5.2 W·kg (2 minutes), 67.1 ± 5.9 W·kg (3 minutes), and 66.2 ± 6.5 W·kg (4 minutes). Trivial or unclear differences in power output were observed between rest intervals at each incremental load. As expected, power declined per 10 kg increment in load, the magnitude of decrease was 13.9-14.5% (confidence limits [CL]: ±1.3-2.0%) and 13.4-14.6% (CL: ±2.4-3.9%) for relative peak and mean power, respectively, yet differences in power output between conditions were likely insubstantial. The prescription of rest intervals between loads that are longer than 1 minute have a likely negligible effect on muscular power production in the jump squat incremental load-power profile. Practitioners should select either a 1- to 4-minute rest interval to best accommodate the logistical constraints of their monitoring sessions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Training at the load that maximizes peak mechanical power (Pmax) is considered superior for the development of power. We aimed to identify the Pmax load ('optimal load') in the jump squat and to quantify small, moderate, large, and very large substantial differences in power output across a spectrum of loads to identify loads that are substantially different to the optimal, and lastly, to investigate the nature of power production (load-force-velocity profiles). Professional Australian Rules Football (ARF; n = 16) and highly trained Rugby Union (RU; n = 20) players (subdivided into stronger [SP] vs. weaker [WP] players) performed jump squats across incremental loads (0-60 kg). Substantial differences in peak power (W·kg(-1)) were quantified as 0.2-2.0 of the log transformed between-athlete SD at each load, backtransformed and expressed as a percent with 90% confidence limits (CL). A 0-kg jump squat maximized peak power (ARF: 57.7 ± 10.8 W·kg(-1); RU: 61.4 ± 8.5 W·kg(-1); SP: 64.4 ± 7.5 W·kg(-1); WP: 54.8 ± 9.5 W·kg(-1)). The range for small to very large substantial differences in power output was 4.5-55.9% (CL: ×/÷1.36) and 2.8-32.4% (CL: ×/÷1.31) in ARF and RU players, whereas in SP and WP, it was 3.7-43.1% (CL: ×/÷1.32) and 4.3-51.7% (CL: ×/÷1.36). Power declined per 10-kg increment in load, 14.1% (CL: ±1.6) and 10.5% (CL: ±1.5) in ARF and RU players and 12.8% (CL: ±1.9) and 11.3% (CL: ±1.7) in SP and WP. The use of a 0-kg load is superior for the development of jump squat maximal power, with moderate to very large declines in power output observed at 10- to 60-kg loads. Yet, performance of heavier load jump squats that are substantially different to the optimal load are important in the development of sport-specific force-velocity qualities and should not be excluded.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The power consumption of wireless sensor networks (WSN) module is an important practical concern in building energy management (BEM) system deployments. A set of metrics are created to assess the power profiles of WSN in real world condition. The aim of this work is to understand and eventually eliminate the uncertainties in WSN power consumption during long term deployments and the compatibility with existing and emerging energy harvesting technologies. This paper investigates the key metrics in data processing, wireless data transmission, data sensing and duty cycle parameter to understand the system power profile from a practical deployment prospective. Based on the proposed analysis, the impacts of individual metric on power consumption in a typical BEM application are presented and the subsequent low power solutions are investigated.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents evaluations among the most usual MPPT techniques, doing meaningful comparisons with respect to the amount of energy extracted from the photovoltaic panel (PV) (Tracking Factor - TF) in relation to the available power, PV voltage ripple, dynamic response and use of sensors. Using MatLab/Simulink® and DSpace platforms, a digitally controlled boost DC-DC converter was implemented and connected to an Agilent Solar Array E4350B simulator in order to verify the analytical procedures. The main experimental results are presented and a contribution in the implementation of the IC algorithm is performed and called IC based on PI. Moreover, the dynamic response and the tracking factor are also evaluated using a Friendly User Interface, which is capable of online program power curves and compute the TF. Finally, a typical daily insulation is used in order to verify the experimental results for the main PV MPPT methods. © 2011 IEEE.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We report the impact of longitudinal signal power profile on the transmission performance of coherently-detected 112 Gb/s m-ary polarization multiplexed quadrature amplitude modulation system after compensation of deterministic nonlinear fibre impairments. Performance improvements up to 0.6 dB (Q(eff)) are reported for a non-uniform transmission link power profile. Further investigation reveals that the evolution of the transmission performance with power profile management is fully consistent with the parametric amplification of the amplified spontaneous emission by the signal through four-wave mixing. In particular, for a non-dispersion managed system, a single-step increment of 4 dB in the amplifier gain, with respect to a uniform gain profile, at similar to 2/3(rd) of the total reach considerably improves the transmission performance for all the formats studied. In contrary a negative-step profile, emulating a failure (gain decrease or loss increase), significantly degrades the bit-error rate.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We report an efficient power tapping device working in near infra-red (800 nm) wavelength region based on UV-in- scribed 45° tilted fiber grating (45°-TFG) structure. Five 45°-TFGs were UV-inscribed in hydrogenated PS750 fiber using a custom-designed phase mask with different grating lengths of 3 mm, 5 mm, 9 mm, 12 mm and 15 mm, showing polarization dependent losses (PDLs) of 1 dB, 3 dB, 7 dB, 10 dB and 13 dB, respectively. The power side-tapping efficiency is clearly depending on the grating strength. It has been identified that the power tapping efficiency increases with the grating strength and deceases along the grating length. The side-tapped power profile has also been examined in azimuthal direction, showing a near-Gaussian distribution. These experimental results clearly demonstrated that 45°- TFGs may be used as in-fiber power tapping devices for applications requiring in-line signal monitoring.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We report the impact of longitudinal signal power profile on the transmission performance of coherently-detected 112 Gb/s m-ary polarization multiplexed quadrature amplitude modulation system after compensation of deterministic nonlinear fibre impairments. Performance improvements up to 0.6 dB (Q(eff)) are reported for a non-uniform transmission link power profile. Further investigation reveals that the evolution of the transmission performance with power profile management is fully consistent with the parametric amplification of the amplified spontaneous emission by the signal through four-wave mixing. In particular, for a non-dispersion managed system, a single-step increment of 4 dB in the amplifier gain, with respect to a uniform gain profile, at similar to 2/3(rd) of the total reach considerably improves the transmission performance for all the formats studied. In contrary a negative-step profile, emulating a failure (gain decrease or loss increase), significantly degrades the bit-error rate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There has been an increased use of the Doubly-Fed Induction Machine (DFIM) in ac drive applications in recent times, particularly in the field of renewable energy systems and other high power variable-speed drives. The DFIM is widely regarded as the optimal generation system for both onshore and offshore wind turbines and has also been considered in wave power applications. Wind power generation is the most mature renewable technology. However, wave energy has attracted a large interest recently as the potential for power extraction is very significant. Various wave energy converter (WEC) technologies currently exist with the oscillating water column (OWC) type converter being one of the most advanced. There are fundemental differences in the power profile of the pneumatic power supplied by the OWC WEC and that of a wind turbine and this causes significant challenges in the selection and rating of electrical generators for the OWC devises. The thesis initially aims to provide an accurate per-phase equivalent circuit model of the DFIM by investigating various characterisation testing procedures. Novel testing methodologies based on the series-coupling tests is employed and is found to provide a more accurate representation of the DFIM than the standard IEEE testing methods because the series-coupling tests provide a direct method of determining the equivalent-circuit resistances and inductances of the machine. A second novel method known as the extended short-circuit test is also presented and investigated as an alternative characterisation method. Experimental results on a 1.1 kW DFIM and a 30 kW DFIM utilising the various characterisation procedures are presented in the thesis. The various test methods are analysed and validated through comparison of model predictions and torque-versus-speed curves for each induction machine. Sensitivity analysis is also used as a means of quantifying the effect of experimental error on the results taken from each of the testing procedures and is used to determine the suitability of the test procedures for characterising each of the devices. The series-coupling differential test is demonstrated to be the optimum test. The research then focuses on the OWC WEC and the modelling of this device. A software model is implemented based on data obtained from a scaled prototype device situated at the Irish test site. Test data from the electrical system of the device is analysed and this data is used to develop a performance curve for the air turbine utilised in the WEC. This performance curve was applied in a software model to represent the turbine in the electro-mechanical system and the software results are validated by the measured electrical output data from the prototype test device. Finally, once both the DFIM and OWC WEC power take-off system have been modeled succesfully, an investigation of the application of the DFIM to the OWC WEC model is carried out to determine the electrical machine rating required for the pulsating power derived from OWC WEC device. Thermal analysis of a 30 kW induction machine is carried out using a first-order thermal model. The simulations quantify the limits of operation of the machine and enable thedevelopment of rating requirements for the electrical generation system of the OWC WEC. The thesis can be considered to have three sections. The first section of the thesis contains Chapters 2 and 3 and focuses on the accurate characterisation of the doubly-fed induction machine using various testing procedures. The second section, containing Chapter 4, concentrates on the modelling of the OWC WEC power-takeoff with particular focus on the Wells turbine. Validation of this model is carried out through comparision of simulations and experimental measurements. The third section of the thesis utilises the OWC WEC model from Chapter 4 with a 30 kW induction machine model to determine the optimum device rating for the specified machine. Simulations are carried out to perform thermal analysis of the machine to give a general insight into electrical machine rating for an OWC WEC device.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La constante crisis que ha atravesado la república Islámica de Afganistán, durante más de dos décadas, tiene sus cimientos en el choque entre las diferentes etnias y grupos religiosos que conforman la sociedad afgana, los cuales han conformado una larga lucha por hacerse al poder y a la dirigencia de esta nación. Pashtunes, tayikos y hazaras, son parte de la composición étnica, mientras que sunitas y chiítas por parte del Islám, y minorías budistas, hinduistas y sijs, conforman la variedad de religiones que se encuentran en este país. La mayoría de población es pashtun y sunnita, y por lo mismo la mayoría de gobiernos que han encabezado la nación afgana han sido igualmente de esta etnia y religión. A pesar de ello, se encuentran hasta hoy diferencias entre este mismo grupo que se expresan en cuán estricta debe ser regida la vida de un musulmán por el Corán y la Sharia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents evaluations among the most usual maximum power point tracking (MPPT) techniques, doing meaningful comparisons with respect to the amount of energy extracted from the photovoltaic (PV) panel [tracking factor (TF)] in relation to the available power, PV voltage ripple, dynamic response, and use of sensors. Using MatLab/Simulink and dSPACE platforms, a digitally controlled boost dc-dc converter was implemented and connected to an Agilent Solar Array E4350B simulator in order to verify the analytical procedures. The main experimental results are presented for conventional MPPT algorithms and improved MPPT algorithms named IC based on proportional-integral (PI) and perturb and observe based on PI. Moreover, the dynamic response and the TF are also evaluated using a user-friendly interface, which is capable of online program power profiles and computes the TF. Finally, a typical daily insulation is used in order to verify the experimental results for the main PV MPPT methods. © 2012 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: To investigate the test-retest reliability of mechanical parameters derived from a 3-min isokinetic all-out test, performed at 60 and 100 rpm. Reliability and validity of the peak oxygen uptake derived from 3-min isokinetic all-out test were also tested. Design: 14 healthy male subjects completed an incremental ramp testing and four randomized 3-min isokinetic all-out test (two at 60 rpm and two at 100 rpm). Methods: The absolute and relative reliability of the following parameters were analyzed: peak power, mean power, end power, fatigue index, work performed above end power and peak oxygen uptake. Results: No difference was found between each two sets of data, although there were between-cadence differences for peak power, mean power, end power, and fatigue index. Higher intra-class correlation (ICC) and lower coefficient of variation (CV) were found for end power (ICC = 0.91 and 0.95; CV = 5.6 and 5.7%) and mean power (ICC = 0.97 and 0.98; CV = 2.4 and 3.1%), than for peak power (ICC = 0.81 and 0.84; CV = 8.7 and 10%) and work performed above end power (ICC = 0.79 and 0.84; CV = 7.9 and 10.6%; values reported for 60 rpm and 100 rpm, respectively). High reliability scores were also observed for peak oxygen uptake at both cadences (60 rpm, CV = 3.2%; 100 rpm, CV = 2.3%,) with no difference with the incremental ramp testing peak oxygen uptake. Conclusions: The power profile and peak oxygen uptake of a 3-min isokinetic all-out test are both highly reliable, whether the test is performed at 60 or 100 rpm. Besides, peak oxygen uptake and work performed above end power were not affected by the change in cadence while peak power, mean power, end power, and fatigue index were. © 2013.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En este estudio se ha realizado el diseño de un receptor de una central de Torre Central de energía solar para generación directa de vapor, mediante el uso de métodos numéricos, con un perfil de potencia incidente variable longitudinal y transversalmente. Para ello se ha dividido la geometría del receptor según el método de diferencias finitas, y se ha procedido a resolver las ecuaciones del balance de energía. Una vez resuelto el sistema de ecuaciones se dispone de la distribución de temperaturas en el receptor y se puede proceder a analizar los resultados así como a calcular otros datos de interés. ABSTRACT In this study it has been made a Central Receiver Solar Thermal Power Plant’s Receiver design for direct steam production, by using numerical methods, with a variable longitudinally and transversely income solar power profile. With this propose, the receiver’s geometry has been divided using the finite difference method, and the energy balance equations have been solved. Once the equations system has been solved, the receiver´s temperature distribution is known, and you can analyze the results as well as calculate other interesting data.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ocean energy is a promising resource for renewable electricity generation that presents many advantages, such as being more predictable than wind energy, but also some disadvantages such as large and slow amplitude variations in the generated power. This paper presents a hardware-in-the-loop prototype that allows the study of the electric power profile generated by a wave power plant based on the oscillating water column (OWC) principle. In particular, it facilitates the development of new solutions to improve the intermittent profile of the power fed into the grid or the test of the OWC behavior when facing a voltage dip. Also, to obtain a more realistic model behavior, statistical models of real waves have been implemented.