994 resultados para Power Doppler


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evaluate the distribution and variation of placental vascular indices according to gestational age and placental volume. From March to November 2007, three-dimensional (3D)-power Doppler ultrasound was performed in 295 normal pregnancies from 12 to 40 weeks of gestation. Using the same preestablished settings for all patients, power Doppler was applied to the placenta and placental Volume was obtained by the rotational technique (VOCAL(TM)). The 3D-power histogram was used to determine the placental vascular indices: vascularization index (VI), flow index (FI) and vascularization-flow index (VFI). The placental vascular indices were then plotted against gestational age and placental volume. All placental vascular indices showed constant distribution throughout gestation. A tendency for a reduction in placental vascular indices with increased placental volume was observed, but was only statistically significant when placental FI was considered (p < 0.05). All placental vascular indices estimated by 3D-power Doppler ultrasonography presented constant distribution throughout gestation, despite the increase in placental volume according to gestational age. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

No safe ultrasound (US) parameters have been established to differentiate the causes of graft dysfunction.To define US parameters and identify the predictors of normal graft evolution, delayed graft function (DGF), and rejection at the early period after kidney transplantation.Between June 2012 and August 2013, 79 renal transplant recipients underwent US examination 1-3 days posttransplantation. Resistive index (RI), power Doppler (PD), and RI + PD (quantified PD) were assessed. Patients were allocated into three groups: normal graft evolution, DGF, and rejection.Resistive index of upper and middle segments and PD were higher in the DGF group than in the normal group. ROC curve analysis revealed that RI + PD was the index that best correlated with DGF (cutoff = 0.84). In the high RI + PD group, time to renal function recovery (6.33 +/- A 6.5 days) and number of dialysis sessions (2.81 +/- A 2.8) were greater than in the low RI + PD group (2.11 +/- A 5.3 days and 0.69 +/- A 1.5 sessions, respectively), p = 0.0001. Multivariate analysis showed that high donor final creatinine with a relative risk (RR) of 19.7 (2.01-184.7, p = 0.009) and older donor age (RR = 1.17 (1.04-1.32), p = 0.007) correlated with risk DGF.Quantified PD (RI + PD) was the best DGF predictor. PD quantification has not been previously reported .

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tendinous lesions are very common in athlete horses. The process of tendon healing is slow and the quality of the new tissue is often inferior to the original, leading in many cases to recurrence of the lesion. One of the main reasons for the limited healing capacity of tendons is its poor vascularization. At present, cell therapy is used in equine practice for the treatment of several disorders including tendinitis, desmitis and joint disease. However, there is little information regarding the mechanisms of action of these cells during tissue repair. It is known that Mesenchymal Stem Cells (MSCs) release several growth factors at the site of implantation, some of which promote angiogenesis. Comparison of blood flow using power Doppler ultrasonography was performed after the induction superficial digital flexor tendon tendinitis and implantation of adipose tissue-derived MSCs in order to analyze the effect of cell therapy on tendon neovascularization. For quantification of blood vessel histopathological examinations were conducted. Increased blood flow and number of vessels was observed in treated tendons up to 30 days after cell implantation, suggesting promotion of angiogenesis by the cell therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduzione: Negli ultimi anni, il color-power Doppler si è dimostrato un utile strumento per valutare le alterazioni della vascolarizzazione della parete intestinale nelle patologie del tratto gastro-enterico. Più di recente, i mezzi di contrasto ecografici di II generazione associati all’ecografia real-time con basso indice meccanico (CEUS) hanno permesso di valutare ecograficamente il microcircolo, consentendo la valutazione della vascolarizzazione di parete nelle patologie associate a flogosi e neoangiogenesi. Studi recenti hanno documentato i pattern Doppler e CEUS nella malattia infiammatoria intestinale. Le alterazioni della vascolarizzazione di parete nella patologia neoplastica, invece, sono state finora valutate con sola tecnica Doppler. Recenti studi basati sull’impiego di tale metodica hanno in effetti dimostrato che l’intensità del segnale vascolare di parete correla con la variante istologica della neoplasia e con il suo grado di invasione vascolare costituendo così un parametro di neoangiogenesi tumorale. Pertanto, ottenere mediante CEUS una più accurata definizione del microcircolo di parete potrebbe aiutare nella diagnosi differenziale tra patologia infiammatoria e neoplastica dello stomaco e fornire utili informazioni per valutare l’ aggressività del cancro gastrico.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess the intra-reader and inter-reader reliabilities of interpreting ultrasonography by several experts using video clips. METHOD: 99 video clips of healthy and rheumatic joints were recorded and delivered to 17 physician sonographers in two rounds. The intra-reader and inter-reader reliabilities of interpreting the ultrasound results were calculated using a dichotomous system (normal/abnormal) and a graded semiquantitative scoring system. RESULTS: The video reading method worked well. 70% of the readers could classify at least 70% of the cases correctly as normal or abnormal. The distribution of readers answering correctly was wide. The most difficult joints to assess were the elbow, wrist, metacarpophalangeal (MCP) and knee joints. The intra-reader and inter-reader agreements on interpreting dynamic ultrasound images as normal or abnormal, as well as detecting and scoring a Doppler signal were moderate to good (kappa = 0.52-0.82). CONCLUSIONS: Dynamic image assessment (video clips) can be used as an alternative method in ultrasonography reliability studies. The intra-reader and inter-reader reliabilities of ultrasonography in dynamic image reading are acceptable, but more definitions and training are needed to improve sonographic reproducibility.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Enthesitis is the hallmark of spondyloarthritis and is observed in all subtypes. Namely, a wide information on spondyloarthritis abnormalities, including synovitis, bursitis, tendinitis, enthesitis and cortical bone abnormalities (erosions and enthesophytes), can be efficiently perceived by ultrasound power Doppler. Furthermore, several studies on imaging of enthesis showed that imaging techniques are better than clinical examination to detect pathology at asymptomatic enthesis. Vascularized enthesitis detected by ultrasound power Doppler appears to be a valuable diagnostic tool to confirm spondyloarthritis diagnosis. This article focuses on the validity and reliability of ultrasound enthesitis assessment in the management of spondyloarthritis patients.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The Doppler ultrasound allows the assessment of blood flow and the differentiate vessels according to each spectral pattern, location and organ that irrigate, helping the examinations and disease diagnosis. The main methods used are Pulsed Doppler, Color Doppler and Power Doppler. In Brazil veterinary medicine, it shows progress since 1990, but its use is limited by the equipment high cost, the need for operator experience and patient cooperation. There are studies in obstetrics and reproduction of dogs and cats, such as evaluation of the testicular vasculature, including the use of contrast material, and attempts to evaluate prostate in healthy dogs or pathological conditions (cancer and testicular torsion , orchitis and benign prostatic hyperplasia; estrous cycle monitoring, evaluation of irrigation in follicles and corpus luteum, uterus and breasts (mammary tumors) in bitches; monitoring pregnancy from the assessment of maternal, fetal and placental hemodynamics, both in dogs as in cats, and aspirations for early detection of pregnancy in dogs. However, new studies are still required, given the lack of these species, especially cats

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Doppler ultrasonography is a new technology that has been study by researchers to improve the physiologic and pathologic knowledge about reproduction. This technology is based on Doppler-shifts frequencies or ultrasonic, these frequencies can be increase or decrease according to the movements of the red cells in the vessel. Color Doppler and power Doppler are the two possibilities to use the Doppler ultrasonography. Color Doppler is based in more the one color that show the direction of the blood f low and power Doppler is based in one color that change according of the flow intensity. Doppler ultrasonography can be demonstrated with the spectral mode to verify blood flow in large vessels, because of this, it is not use in equine reproduction. Studies in equine reproduction have been doing to verify uterus blood flow in cyclic mares and to observe the vascular perfusion in mares with cists, uterine vascular perfusion post breeding and verify the affects of drugs to decrease the uterus fluid in mares with problems in uterus perfusion. The ovarian irrigation during the estrus cycle was analyze with the measurement of the principal hormones during the estrus cycle in mares, the integrity of the corpus luteus, the irrigation of the future dominant follicle and the consequences in the ovarian irrigation after luteolyse induction also were study. Nevertheless, more than the knowledge that existed about Doppler ultrasonography, new studies have been doing to improve the forms to use Doppler ultrasonography in equine reproduction

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective To evaluate the intra- and interobserver reliability of assessment of three-dimensional power Doppler (3D-PD) indices from single spherical samples of the placenta. Methods Women with singleton pregnancies at 2440 weeks' gestation were included. Three scans were independently performed by two observers; Observer 1 performed the first and third scan, intercalated by the scan of Observer 2. The observers independently analyzed the 3D-PD datasets that they had previously acquired using four different methods, each using a spherical sample: random sample extending from basal to chorionic plate; random sample with 2 cm3 of volume; directed sample to the region subjectively determined as containing more color Doppler signals extending from basal to chorionic plate; or directed sample with 2 cm3 of volume. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were evaluated in each case. The observers were blinded to their own and each other's results. Additional evaluation was performed according to placental location: anterior, posterior and fundal or lateral. Intra- and interobserver reliability was assessed by intraclass correlation coefficients (ICC). Results Ninety-five pregnancies were included in the analysis. All three placental 3D-PD indices showed only weak to moderate reliability (ICC < 0.66 and ICC < 0.48, intra- and interobserver, respectively). The highest values of ICC were observed when using directed spherical samples from basal to chorionic plate. When analyzed by placental location, we found lower ICCs for lateral and fundal placentae compared to anterior and posterior ones. Conclusion Intra- and interobserver reliability of assessment of placental 3D-PD indices from single spherical samples in pregnant women greater than 24 weeks' gestation is poor to moderate, and clinical usefulness of these indices is likely to be limited. Copyright (c) 2012 ISUOG. Published by John Wiley & Sons, Ltd.