976 resultados para Post-occupancy vvaluation (P.O.E.)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This dissertation of master degree was presented to Post-Graduation Program in Architecture and Planning at UFRN, Brazil. It evaluates 45 one-family housings in the Metropolitan Area of Recife, whose architects consider them to be in conformity with the recommendations contained in Armando de Holanda's book: A Guide to build in the Brazilian Northeast: Architecture as a pleasant place in the sunny tropics , published in 1976 by UFPE. For a long time, it used to be reference in many Architecture and Planning Schools of the Northern Region of Brazil. The research s methodological procedures are based on the Post- Occupancy Evaluation (P.O.E.) with emphasis on the users' thermal comfort of the houses that make part of the sample. Therefore, it has been done technical analyses of the projects, when possible; interviews with the architects; building s inspections; and form applications to the users. The collected data analysis was based on the project recommendations of Holanda s book, they can be synthesized in the principle of Building Leafy". It can not be affirmed that all the houses present the recommendations contained in the guide, but, in many different ways, they exist, sometimes more intensely and sometimes more shyly. However, it can be noticed that in the 45 projects, that the architects perceived the importance of "Building Leafy" on the climatic reality of the Metropolitan Region of Recife

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This dissertation of master degree was presented to Post-Graduation Program in Architecture and Planning at UFRN, Brazil. It evaluates 45 one-family housings in the Metropolitan Area of Recife, whose architects consider them to be in conformity with the recommendations contained in Armando de Holanda's book: A Guide to build in the Brazilian Northeast: Architecture as a pleasant place in the sunny tropics , published in 1976 by UFPE. For a long time, it used to be reference in many Architecture and Planning Schools of the Northern Region of Brazil. The research s methodological procedures are based on the Post- Occupancy Evaluation (P.O.E.) with emphasis on the users' thermal comfort of the houses that make part of the sample. Therefore, it has been done technical analyses of the projects, when possible; interviews with the architects; building s inspections; and form applications to the users. The collected data analysis was based on the project recommendations of Holanda s book, they can be synthesized in the principle of Building Leafy". It can not be affirmed that all the houses present the recommendations contained in the guide, but, in many different ways, they exist, sometimes more intensely and sometimes more shyly. However, it can be noticed that in the 45 projects, that the architects perceived the importance of "Building Leafy" on the climatic reality of the Metropolitan Region of Recife

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This dissertation of master degree was presented to Post-Graduation Program in Architecture and Planning at UFRN, Brazil. It evaluates 45 one-family housings in the Metropolitan Area of Recife, whose architects consider them to be in conformity with the recommendations contained in Armando de Holanda's book: A Guide to build in the Brazilian Northeast: Architecture as a pleasant place in the sunny tropics , published in 1976 by UFPE. For a long time, it used to be reference in many Architecture and Planning Schools of the Northern Region of Brazil. The research s methodological procedures are based on the Post- Occupancy Evaluation (P.O.E.) with emphasis on the users' thermal comfort of the houses that make part of the sample. Therefore, it has been done technical analyses of the projects, when possible; interviews with the architects; building s inspections; and form applications to the users. The collected data analysis was based on the project recommendations of Holanda s book, they can be synthesized in the principle of Building Leafy". It can not be affirmed that all the houses present the recommendations contained in the guide, but, in many different ways, they exist, sometimes more intensely and sometimes more shyly. However, it can be noticed that in the 45 projects, that the architects perceived the importance of "Building Leafy" on the climatic reality of the Metropolitan Region of Recife

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The international focus on embracing daylighting for energy efficient lighting purposes and the corporate sector’s indulgence in the perception of workplace and work practice “transparency” has spurned an increase in highly glazed commercial buildings. This in turn has renewed issues of visual comfort and daylight-derived glare for occupants. In order to ascertain evidence, or predict risk, of these events; appraisals of these complex visual environments require detailed information on the luminances present in an occupant’s field of view. Conventional luminance meters are an expensive and time consuming method of achieving these results. To create a luminance map of an occupant’s visual field using such a meter requires too many individual measurements to be a practical measurement technique. The application of digital cameras as luminance measurement devices has solved this problem. With high dynamic range imaging, a single digital image can be created to provide luminances on a pixel-by-pixel level within the broad field of view afforded by a fish-eye lens: virtually replicating an occupant’s visual field and providing rapid yet detailed luminance information for the entire scene. With proper calibration, relatively inexpensive digital cameras can be successfully applied to the task of luminance measurements, placing them in the realm of tools that any lighting professional should own. This paper discusses how a digital camera can become a luminance measurement device and then presents an analysis of results obtained from post occupancy measurements from building assessments conducted by the Mobile Architecture Built Environment Laboratory (MABEL) project. This discussion leads to the important realisation that the placement of such tools in the hands of lighting professionals internationally will provide new opportunities for the lighting community in terms of research on critical issues in lighting such as daylight glare and visual quality and comfort.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Zero energy buildings (ZEB) and zero energy homes (ZEH) are a current hot topic globally for policy makers (what are the benefits and costs), designers (how do we design them), the construction industry (can we build them), marketing (will consumers buy them) and researchers (do they work and what are the implications). This paper presents initial findings from actual measured data from a 9 star (as built), off-ground detached family home constructed in south-east Queensland in 2008. The integrated systems approach to the design of the house is analysed in each of its three main goals: maximising the thermal performance of the building envelope, minimising energy demand whilst maintaining energy service levels, and implementing a multi-pronged low carbon approach to energy supply. The performance outcomes of each of these stages are evaluated against definitions of Net Zero Carbon / Net Zero Emissions (Site and Source) and Net Zero Energy (onsite generation v primary energy imports). The paper will conclude with a summary of the multiple benefits of combining very high efficiency building envelopes with diverse energy management strategies: a robustness, resilience, affordability and autonomy not generally seen in housing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Glare indices have yet to be extensively tested in daylit open plan offices, as such there is no effective method to predict discomfort glare within these spaces. This study into discomfort glare in open plan green buildings targeted full-time employees, working under their everyday lighting conditions. Three green buildings in Brisbane were used for data collection, two were Green Star accredited and the other contained innovative daylighting strategies. Data were collected on full-time employees, mostly aged between 30 and 50 years, who broadly reflect the demographics of the wider working population in Australia. It was discovered 36 of the 64 respondents experienced discomfort from both electric and daylight sources at their workspace. The study used a specially tailored post-occupancy evaluation (POE) survey to help assess discomfort glare. Luminance maps extracted from High Dynamic Range (HDR) images were used to capture the luminous environment of the occupants. These were analysed using participant data and the program Evalglare. The physical results indicated no correlation with other developed glare metrics for daylight within these open plan green buildings, including the recently developed Daylight Glare Probability (DGP) Index. The strong influence of vertical illuminance, Ev in the DGP precludes the mostly contrast-based glare from windows observed in this investigation from forming a significant part of this index. Furthermore, critical assessment of the survey techniques used are considered. These will provide insight for further research into discomfort glare in the endeavour to fully develop a suitable glare metric.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research was commissioned by Metecno Pty Ltd, trading as Bondor®. The InsulLiving house was designed and constructed by Bondor®. The house instrumentation (electricity circuits, indoor environment, weather station) was provided by Bondor and supplied and installed by independent contractors. This report contains analysis of data collected from the InsulLiving house at Burpengary during 1 year of occupancy by a family of four for the period 1 April 2012 – 31 March 2013. The data shows a daily average electricity consumption 48% less than the regional average. The analysis confirms that the 9 star house performed thermally slightly better than the simulated performance. The home was 'near zero energy', with its modest 2.1kW solar power system meeting all of the needs for space heating and cooling, lighting and most water heating.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper explores the historical development of POE in order to provide a contextual backdrop to current discussions. This review provides a much needed discussion on the benefits and barriers facing POE which should enable designers, facility managers and building users to appreciate the value and purpose of this important building evaluation process. The paper will encourage architects and building owners to conduct POEs to benefit all stakeholders and future designs. This is an international peer reviewed journal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A combined windcatcher and light pipe (SunCatcher) was installed in the seminar room at the University of Reading, UK. Monitoring of indoor environment in real weather conditions was conducted to evaluate the application of windcatchers for natural ventilation. In addition, a subjective occupancy survey was undertaken. External weather conditions and internal indoor air quality indicators were recorded. The “tracer-gas decay” method using SF6 was used to establish air change rate for various conditions. The results indicated that the ventilation rate achieved through the windcatcher depends on the difference between internal and external air temperatures, and on wind speed and direction, in agreement with other published work in the area. The indoor air quality parameters were found to be within acceptable levels when the windcatcher was in operation. The measured air change rate was between 1.5ac/h and 6.8ac/h. Occupants’ questionnaires showed 75 per cent satisfaction with the internal conditions and welcomed the installation of the systems in UK buildings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper considers the relationship between value management and facilities management. The findings are particularly relevant to large client organisations which procure new buildings on a regular basis. It is argued that the maximum effectiveness of value management can only be achieved if it is used in conjunction with an ongoing commitment to post-occupancy evaluation. SMART value management is seen to provide the means of ensuring that an individual building design is in alignment with the client’s strategic property needs. However, it is also necessary to recognise that an organisation’s strategic property needs will continually be in a state of change. Consequentially, economic and functional under-performance can only be avoided by a regular performance audit of existing property stock in accordance with changing requirements. Such a policy will ensure ongoing competitiveness through organisational learning. While post-occupancy evaluation represents an obvious additional service to be provided by value management consultants, it is vital that the necessary additional skills are acquired. Process management skills and social science research techniques are clearly important. However, there is also a need to improve mechanisms for data manipulation. Success can only be achieved if equal attention is given to issues of process, structure and content.