986 resultados para Pos-processing software


Relevância:

100.00% 100.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Office of Research and Development, Washington, D.C.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Laser speckle contrast imaging (LSCI) has the potential to be a powerful tool in medicine, but more research in the field is required so it can be used properly. To help in the progression of Michigan Tech's research in the field, a graphical user interface (GUI) was designed in Matlab to control the instrumentation of the experiments as well as process the raw speckle images into contrast images while they are being acquired. The design of the system was successful and is currently being used by Michigan Tech's Biomedical Engineering department. This thesis describes the development of the LSCI GUI as well as offering a full introduction into the history, theory and applications of LSCI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A ciência na qual se estuda a deformação de um fluido no qual é aplicada uma tensão de cisalhamento é conhecida como reologia e o equipamento utilizado para a realização dos ensaios é chamado de reômetro. Devido a impraticabilidade de uso de reômetros comerciais, diversos pesquisadores desenvolveram reômetros capazes de analisar suspensões de macropartículas, baseados nos mesmos princípios de funcionamento dos equipamentos já existentes. Em alguns casos, a medição do torque do motor é realizada pela aquisição da tensão, uma vez que esta é proporcional ao torque. Entretanto, para melhor compreensão do resultado e para evitar a possibilidade de conclusões precipitadas, vê-se necessária correta interpretação do sinal elétrico, precisando avaliar qual frequência do sinal é relevante para o ensaio e, também, qual a melhor taxa de amostragem. Além da aquisição, para que o ensaio reológico seja realizado com precisão, é indispensável ótimo controle da taxa ou tensão do motor e uma alternativa é a utilização de um servomotor e um servoconversor. No caso desse ser comercial é essencial saber configurá-lo. Para facilitar o usuário leigo, alguns pesquisadores desenvolveram softwares para controle do equipamento e análise dos dados. Assim, o presente trabalho tem como objetivo propor uma metodologia para compreender o sinal aquisitado de um reômetro servo controlado e desenvolvimento do software de análise para o tratamento dos dados obtidos a partir de ensaios reológicos. Verificou-se a melhor configuração do servocontrolador, a melhor taxa de amostragem, de no mínimo 20 amostras/segundo, e, também, desenvolveu-se um filtro digital passa-baixa do tipo FIR para remover a frequência indesejada. Além disso, foi desenvolvido um software utilizando uma rotina em Matlab e uma interface gráfica do usuário (Graphical User Interface - GUI), para o pós-processamento dos dados para auxiliar o usuário leigo no tratamento e interpretação do resultado, que se mostrou eficaz.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose Physiological respiratory motion of tumors growing in the lung can be corrected with respiratory gating when treated with radiotherapy (RT). The optimal respiratory phase for beam-on may be assessed with a respiratory phase optimizer (RPO), a 4D image processing software developed with this purpose. Methods and Materials Fourteen patients with lung cancer were included in the study. Every patient underwent a 4D-CT providing ten datasets of ten phases of the respiratory cycle (0-100% of the cycle). We defined two morphological parameters for comparison of 4D-CT images in different respiratory phases: tumor-volume to lung-volume ratio and tumor-to-spinal cord distance. The RPO automatized the calculations (200 per patient) of these parameters for each phase of the respiratory cycle allowing to determine the optimal interval for RT. Results Lower lobe lung tumors not attached to the diaphragm presented with the largest motion with breathing. Maximum inspiration was considered the optimal phase for treatment in 4 patients (28.6%). In 7 patients (50%), however, the RPO showed a most favorable volumetric and spatial configuration in phases other than maximum inspiration. In 2 cases (14.4%) the RPO showed no benefit from gating. This tool was not conclusive in only one case. Conclusions The RPO software presented in this study can help to determine the optimal respiratory phase for gated RT based on a few simple morphological parameters. Easy to apply in daily routine, it may be a useful tool for selecting patients who might benefit from breathing adapted RT.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Acoustic resonances are observed in high-pressure discharge lamps operated with ac input modulated power frequencies in the kilohertz range. This paper describes an optical resonance detection method for high-intensity discharge lamps using computer-controlled cameras and image processing software. Experimental results showing acoustic resonances in high-pressure sodium lamps are presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

There is virtually no literature on the effect of correction of syndromal faciocraniosynostosis with monobloc advancement on the palpebral fissure shape. Using image processing software, we measured the effect of monobloc advancement on the position of the upper and lower eyelids as well as the palpebral fissure slant in a series of 18 patients with syndromal faciocraniosynostosis who had undergone surgery for correction of orbital and midface hypoplasia. For both eyed of each patient, 3 variables were measured on the pre- and postoperative photographs: the linear distances between the upper and lower eyelid margins, the pupil center and the angle between the inner and outer canthi. The globe protrusion was also measured on axial computed tomography scans before and after surgery. The results indicate that the exorbitism reduction induced by monobloc advancement is accompanied by a diminution of the distance between both eyelids and the pupil center. However, the downward slant of the palpebral fissure is increased after surgery. The data suggest that the lower and upper eyelid retraction seen preoperatively in the majority of patients with faciocraniosynostosis tend to be corrected when the frontofacial region is advanced by the monobloc. On the other hand, the surgery tends to lower the outer canthus, increasing the negative slant of the fissure. The postoperative changes induced by the frontofacial monobloc advancement need to be taken into account when the surgery is going to be performed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The increasing availability of mobility data and the awareness of its importance and value have been motivating many researchers to the development of models and tools for analyzing movement data. This paper presents a brief survey of significant research works about modeling, processing and visualization of data about moving objects. We identified some key research fields that will provide better features for online analysis of movement data. As result of the literature review, we suggest a generic multi-layer architecture for the development of an online analysis processing software tool, which will be used for the definition of the future work of our team.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A Ressonância Magnética Mamaria (RMM), ao longo da década, tem demonstrado um franco desenvolvimento no diagnóstico e caracterização do Carcinoma Mamário. O objectivo deste trabalho científico é demonstrar, através de uma revisão bibliográfica, os avanços desta modalidade na avaliação das lesões da mama, tendo em conta as características: elasticidade (Elastografia), bioquímicas (Espectroscopia), celularidade (Difusão) e vascularização (Perfusão). A avaliação destas em consonância com as morfológicas e cinéticas (RMM), permitem um aumento da especificidade da RMM, reduzindo assim o número de biopsias desnecessárias. Contudo estas evoluções técnicas devem estar em consonância com a inovação em questões de software de processamento de Imagem e hardware dos equipamentos de Ressonância Magnética.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

25th Conference of the European Cetacean Society. Long-terms datasets on marine mammals: learning from the past to manage the future, Cadiz, Spain, 21-23 March 2011.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Intervenção Sócio-Organizacional na Saúde - Área de especialização: Políticas de Administração e Gestão de Serviços de Saúde

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aquest treball consisteix en l'anàlisi i disseny d'una aplicació per la gestió de reserves d'un complex de 39 apartaments, anomenat AIDA

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aquest projecte ha procurat reflectir les diferents opcions que té la Mútua a l'hora d'actualitzar el seu sistema informàtic. Després d'estudiar la viabilitat de les diferents opcions proposa solucions per a tots els aspectes plantejats.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

En aquest treball de final de carrera es procura resoldre el problema de la seguretat informàtica en les comunicacions entre dues entitats per a poder protegir la informació sensible quan viatgi per la xarxa. Per fer-ho, s?utilitzen una sèrie de tècniques basades en la criptografia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aquest TFC vol fer una presentació del model CMM, presentar un sistema de gestió que cobreixi els seus requeriments a nivell 3, fer una proposta de desplegament i avaluar els costos i els beneficis de l'adopció del nou sistema de gestió per a una empresa dedicada al desenvolupament i el manteniment de programari. El resultat del treball és la memòria en si i els seus annexos.