873 resultados para Portable audio device


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The coagulation of milk is the fundamental process in cheese-making, based on a gel formation as consequence of physicochemical changes taking place in the casein micelles, the monitoring the whole process of milk curd formation is a constant preoccupation for dairy researchers and cheese companies (Lagaude et al., 2004). In addition to advances in composition-based applications of near infrared spectroscopy (NIRS), innovative uses of this technology are pursuing dynamic applications that show promise, especially in regard to tracking a sample in situ during food processing (Bock and Connelly, 2008). In this way the literature describes cheese making process applications of NIRS for curd cutting time determination, which conclude that NIRS would be a suitable method of monitoring milk coagulation, as shown i.e. the works published by Fagan et al. (Fagan et al., 2008; Fagan et al., 2007), based in the use of the commercial CoAguLite probe (with a LED at 880nm and a photodetector for light reflectance detection).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Akkuteknologia on kehittynyt viime vuosina erityyppisten litium-ioniakkujen hallitessa markkinoita. Uutta teknologiaa kaupallisissa litium-pohjaisissa akuissa edustavat litium-polymeeri- ja litium-rautafosfaattiakut. Työn tarkoituksena oli selvittää soveltuvatko litium-polymeeri- ja litium-rautafosfaattiakut kannettavaan audiolaitteeseen ja verrata näitä Ni-Cd- ja Ni-Mh-akkuihin sekä LiCoO2- ja LiMnO4-kemian litium-ioniakkuihin. Kyseisten akkutyyppien soveltuvuutta kannettavaan audiolaitteeseen ei kirjallisuudessa ole juuri tutkittu. Työ toteutettiin kirjallisuustutkimuksena.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Any transportation infrastructure system is inherently concerned with durability and performance issues. The proportioning and uniformity control of concrete mixtures are critical factors that directly affect the longevity and performance of the portland cement concrete pavement systems. At present, the only means available to monitor mix proportions of any given batch are to track batch tickets created at the batch plant. However, this does not take into account potential errors in loading materials into storage silos, calibration errors, and addition of water after dispatch. Therefore, there is a need for a rapid, cost-effective, and reliable field test that estimates the proportions of as-delivered concrete mixtures. In addition, performance based specifications will be more easily implemented if there is a way to readily demonstrate whether any given batch is similar to the proportions already accepted based on laboratory performance testing. The goal of the present research project is to investigate the potential use of a portable x-ray fluorescence (XRF) technique to assess the proportions of concrete mixtures as they are delivered. Tests were conducted on the raw materials, paste and mortar samples using a portable XRF device. There is a reasonable correlation between the actual and calculated mix proportions of the paste samples, but data on mortar samples was less reliable.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Audiovahvistimet pohjautuvat yhä useammin D-luokan vahvistimiin niiden korkean hyötysuhteen takia. Tämä mahdollistaa pidemmän käyttöajan tai vastaavasti tehon lisäämisen kannettavissa audiolaitteissa. Kuitenkin, jotta akkukäyttöisestä audiolaitteesta saataisiin suurempaa tehoa, se vaatii yleensä korkeamman jännitteen kuin yksittäisen akun lähtöjännite on. Korkeampi jännite voidaan saavuttaa lisäämällä akkuja tai käyttämällä jännitettä nostavaa hakkuria. Hakkureissa syntyy kuitenkin kytkennästä johtuvaa värettä, mille D-luokan vahvistimet ovat alttiita. Tässä työssä tutkitaan boost- ja Čuk-hakkurin soveltuvuutta jännitteen nostoon akkukäyttöisessä audiolaitteessa. Käytännön sovelluksena toimii Porsas, josta halutaan saada 500 W teho. Työssä tutkitaan audiolaitteen asettamia ehtoja jännitelähteelle sekä hakkurien mitoittamista ehtojen mukaisesti. Työn tutkimustapana on kirjallisuustutkimus ja simulointi. Audiolaitteen jännitelähteeltä vaatima teho vaihtelee suuresti. Tämä tulee ottaa huomioon hakkurin komponenttien mitoituksessa. Lisäksi hakkurin lähtöjännitteen väre pyritään minimoimaan, koska sillä on suuri vaikutus vahvistimen toimintaan. Tulovirran väreen minimoinnilla on pidentävä vaikutus akun purkusykliin. Hakkurien laskennalliset komponenttien arvot sekä simuloinnit osoittavat, että hakkurit olisivat myös mahdollista tehdä käytännössä. Simulointien perusteella boost-hakkurin komponenttien arvot ovat pienempiä kuin Čuk-hakkurin. Boost-hakkurille löytyy myös valmiita ohjainpiirejä enemmän. Toisaalta Čuk-hakkurilla on mahdollista tehdä myös energiansäästötila. Hakkurien ohjaus ja jäähdytys vaatisivat jatkotutkimusta.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The widespread of low cost embedded electronics makes it easier to implement the smart devices that can understand either the environment or the user behaviors. The main object of this project is to design and implement home use portable smart electronics, including the portable monitoring device for home and office security and the portable 3D mouse for convenient use. Both devices in this project use the MPU6050 which contains a 3 axis accelerometer and a 3 axis gyroscope to sense the inertial motion of the door or the human hands movement. For the portable monitoring device for home and office security, MPU6050 is used to sense the door (either home front door or cabinet door) movement through the gyroscope, and Raspberry Pi is then used to process the data it receives from MPU6050, if the data value exceeds the preset threshold, Raspberry Pi would control the USB Webcam to take a picture and then send out an alert email with the picture to the user. The advantage of this device is that it is a small size portable stand-alone device with its own power source, it is easy to implement, really cheap for residential use, and energy efficient with instantaneous alert. For the 3D mouse, the MPU6050 would use both the accelerometer and gyroscope to sense user hands movement, the data are processed by MSP430G2553 through a digital smooth filter and a complementary filter, and then the filtered data will pass to the personal computer through the serial COM port. By applying the cursor movement equation in the PC driver, this device can work great as a mouse with acceptable accuracy. Compared to the normal optical mouse we are using, this mouse does not need any working surface, with the use of the smooth and complementary filter, it has certain accuracy for normal use, and it is easy to be extended to a portable mouse as small as a finger ring.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Overactive bladder (OAB) is a prevalent condition with 16% of adults having one or more symptoms that significantly affect quality of life. Transcutaneous electrical nerve stimulation and neuromodulators have had success in treating OAB but are expensive, invasive, and sometimes cumbersome. We developed an alternative neuromodulatory technique that involves electromagnetic stimulation of the sacral nerve roots with a portable electromagnetic device to produce trans-sacral stimulation of the S3 and S4 sacral nerve roots. The aim of this study was to evaluate the impact of this device on OAB symptoms in women with a prospectively randomised double-blind controlled study. Following a power analysis, women with symptoms of OAB were prospectively recruited with ethical approval for randomisation to an active treatment (n = 33) or placebo group (n = 30) in a double-blind trial. The patient, at home, used the belt device daily for 20 min over 12 weeks. Outcome measures included a 3-day voiding diary, 1 h pad test, visual analogue score (VAS) for symptom impact (0-100%), Kings Health Questionnaire (KHQ) and Australian Quality of Life questionnaire (AQOL) at baseline, 6 and 12 weeks. Overall, no difference was found between groups for any of the research questions. Specifically, we were unable to demonstrate any difference between the active and sham device groups in frequency, nocturia, urinary leakage, or quality of life, nor was there any evidence of a placebo effect. The quality of the data was high with the number of missing observations (especially for disease specific KHQ and general AQOL) being few. This attempt to promote trans-sacral electromagnetic neuromodulation with a specially created device was ineffective on the symptoms of OAB.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Body accelerations during human walking were recorded by a portable measuring device. A new method for parameterizing body accelerations and finding the pattern of walking is outlined. Two neural networks were designed to recognize each pattern and estimate the speed and incline of walking. Six subjects performed treadmill walking followed by self-paced walking on an outdoor test circuit involving roads of various inclines. The neural networks were first "trained" by known patterns of treadmill walking. Then the inclines, the speeds, and the distance covered during overground walking (outdoor circuit) were estimated. The results show a good agreement between actual and predicted variables. The standard deviation of estimated incline was less than 2.6% and the maximum of the coefficient of variation of speed estimation is 6%. To the best of our knowledge, these results constitute the first assessment of speed, incline and distance covered during level and slope walking and offer investigators a new tool for assessing levels of outdoor physical activity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to investigate the follicular dynamics during estrous cycle in Gir breed (Bos indicus) cows. Follicular growth and atresia during estrous cycle were evaluated using a portable ultrasound device. Luteal activity was evaluated by serum progesterone levels. Cycles with two (6.67%), three (60.00%), four (26.67%) and five (6.67%) follicular waves were observed. There was no difference (P>0.05) in dominant or subordinate follicles growth or atresia rates among follicular waves. The maximum diameter of the ovulatory follicle was higher than the diameter of the other dominant follicles in cycles with four waves, and higher than the diameter of the second dominant follicle in cycles with three waves (P<0.05). There was no difference (P>0.05) in estrous cycle length (21.11±1.76 and 22.25±1.71 days) or progesterone levels during diestrous (4.48±1.45 and 5.08±1.40 ng/mL) between cycles with three or four waves. Follicular dynamics in Gir cattle is characterized by a higher incidence of cycles with three or four waves, associated with a low persistence of the dominant follicle.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

IMPORTANCE: Glioblastoma is the most devastating primary malignancy of the central nervous system in adults. Most patients die within 1 to 2 years of diagnosis. Tumor-treating fields (TTFields) are a locoregionally delivered antimitotic treatment that interferes with cell division and organelle assembly. OBJECTIVE: To evaluate the efficacy and safety of TTFields used in combination with temozolomide maintenance treatment after chemoradiation therapy for patients with glioblastoma. DESIGN, SETTING, AND PARTICIPANTS: After completion of chemoradiotherapy, patients with glioblastoma were randomized (2:1) to receive maintenance treatment with either TTFields plus temozolomide (n = 466) or temozolomide alone (n = 229) (median time from diagnosis to randomization, 3.8 months in both groups). The study enrolled 695 of the planned 700 patients between July 2009 and November 2014 at 83 centers in the United States, Canada, Europe, Israel, and South Korea. The trial was terminated based on the results of this planned interim analysis. INTERVENTIONS: Treatment with TTFields was delivered continuously (>18 hours/day) via 4 transducer arrays placed on the shaved scalp and connected to a portable medical device. Temozolomide (150-200 mg/m2/d) was given for 5 days of each 28-day cycle. MAIN OUTCOMES AND MEASURES: The primary end point was progression-free survival in the intent-to-treat population (significance threshold of .01) with overall survival in the per-protocol population (n = 280) as a powered secondary end point (significance threshold of .006). This prespecified interim analysis was to be conducted on the first 315 patients after at least 18 months of follow-up. RESULTS: The interim analysis included 210 patients randomized to TTFields plus temozolomide and 105 randomized to temozolomide alone, and was conducted at a median follow-up of 38 months (range, 18-60 months). Median progression-free survival in the intent-to-treat population was 7.1 months (95% CI, 5.9-8.2 months) in the TTFields plus temozolomide group and 4.0 months (95% CI, 3.3-5.2 months) in the temozolomide alone group (hazard ratio [HR], 0.62 [98.7% CI, 0.43-0.89]; P = .001). Median overall survival in the per-protocol population was 20.5 months (95% CI, 16.7-25.0 months) in the TTFields plus temozolomide group (n = 196) and 15.6 months (95% CI, 13.3-19.1 months) in the temozolomide alone group (n = 84) (HR, 0.64 [99.4% CI, 0.42-0.98]; P = .004). CONCLUSIONS AND RELEVANCE: In this interim analysis of 315 patients with glioblastoma who had completed standard chemoradiation therapy, adding TTFields to maintenance temozolomide chemotherapy significantly prolonged progression-free and overall survival. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00916409.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cette thèse porte sur le développement de biocapteurs basés sur la technique de résonance des plasmons de surface (SPR) pour effectuer des analyses directement dans un fluide sanguin n’ayant subi aucune purification ou dilution. L’ensemble des biocapteurs discutés exploiteront un instrument SPR portable développé dans le groupe du professeur Masson. Le premier volet de la thèse portera sur le processus d’interférence lié à l’adsorption non spécifique du sérum à la surface du capteur. L’analyse des biomolécules adsorbées sera effectuée en combinant la SPR à la spectrométrie de masse. Les informations obtenues seront exploitées pour la construction de biocapteurs adaptés à l’analyse en milieu sanguin. Un premier biocapteur développé ciblera la protéine antigène prostatique spécifique (APS) contenue dans le sérum servant de biomarqueur pour dépister le cancer de la prostate. Pour détecter les faibles concentrations de cette protéine directement dans le sérum, un matériel plasmonique microstructuré sera utilisé pour amplifier les signaux obtenus et sera recouvert d’une monocouche peptidique minimisant l’adsorption non spécifique du sérum. L’instrument SPR aura été adapté pour permettre également la détection simultanée de fluorescence. Un test ELISA sera ainsi effectué en parallèle du test SPR. Chacune des techniques fournira un contrôle pour la deuxième, tout en permettant de détecter le biomarqueur au niveau requis pour dépister la maladie. La combinaison des deux méthodes permettra aussi d’élargir la gamme dynamique du test de dépistage. Pour terminer, l’instrument SPR portable sera utilisé dans le cadre de détection de petites biomolécules ayant un potentiel thérapeutique directement dans un échantillon de sang. Des peptides ayant une activité anti-athérosclérotique pourront ainsi être détectés à même un échantillon de sang ni purifié ni dilué, et ce à des concentrations de l’ordre du micromolaire. Une modification de la microfluidique via l’introduction d’une membrane poreuse au cœur de celle-ci sera la clé permettant d’effectuer de telles analyses. La présente thèse met de l’avant de nouvelles stratégies et des modifications instrumentales permettant d’analyser des protéines et des petites molécules directement dans un échantillon non purifié de sérum ou de sang. Les modifications apportées au système fluidique, à l’instrument SPR et au niveau du biocapteur employé permettront d’effectuer des biodétections dans des matrices aussi complexes que les fluides sanguins. Les présents travaux mettent en lumière la capacité d’un instrument SPR/fluorescence portable à faire en 12 minutes la biodétection d’un marqueur du cancer de la prostate directement dans un échantillon de sérum. Finalement, on rapporte ici un des premiers articles où un biocapteur SPR est utilisé à même un échantillon de sang non-purifié pour faire des biodétections.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The problems encountered by individuals with disabilities when accessing large public buildings is described and a solution based on the generation of virtual models of the built environment is proposed. These models are superimposed on a control network infrastructure, currently utilised in intelligent building applications such as lighting, heating and access control. The use of control network architectures facilitates the creation of distributed models that closely mirror both the physical and control properties of the environment. The model of the environment is kept local to the installation which allows the virtual representation of a large building to be decomposed into an interconnecting series of smaller models. This paper describes two methods of interacting with the virtual model, firstly a two dimensional aural representation that can be used as the basis of a portable navigational device. Secondly an augmented reality called DAMOCLES that overlays additional information on a user’s normal field of view. The provision of virtual environments offers new possibilities in the man-machine interface so that intuitive access to network based services and control functions can be given to a user.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Enfermagem (mestrado profissional) - FMB

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)