900 resultados para Polymers -- Effect of radiation on


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of radiation on the Peierls transition in a one-dimensional metal is investigated. It is pointed out that an external radiation field satisfying appropriate frequency conditions reduces the width of the Peierls gap.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The possible occurrence of a generalized (1-wave) nonequilibrium superconducting state in a multiband system under certain conditions is studied. In the model the radiation field causes interband mixing, and phonons of an appropriate mode (branch) are involved in the interband scattering of electrons of two conduction bands of the system. The strength of the generalized 1-wave pairing interaction between quasiparticles belonging to new radiation admixed states depends on the density (n o/V) of quanta in the system. The coupling constant has the form Xl= AiB(n o/V)/[C + B(no/V)], where A1, B, and C are parameters. For C > B(n0/V), the transition temperature T1* increases with (no/V) in the initial stages. It levels off with higher power. With further increase of power, the transition temperature is expected to drop sharply due to heating effects which cause pair breaking. Estimates show that p-wave (triplet state) pairing may be possible under radiation-induced nonequilibrium situations in appropriate systems. Estimates for lifetimes of various processes quasiparticle, phonon, pair relaxation, and photon-induced mixing) show that the coherence required for the mixing and pairing effects will be maintained for the temperature range and photon density considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Increases in pediatric thyroid cancer incidence could be partly due to previous clinical intervention. This retrospective cohort study used 1973-2012 data from the Surveillance Epidemiology and End Results program to assess the association between previous radiation therapy exposure in development of second primary thyroid cancer (SPTC) among 0-19-year-old children. Statistical analysis included the calculation of summary statistics and univariable and multivariable logistic regression analysis. Relative to no previous radiation therapy exposure, cases exposed to radiation had 2.46 times the odds of developing SPTC (95% CI: 1.39-4.34). After adjustment for sex and age at diagnosis, Hispanic children who received radiation therapy for a first primary malignancy had 3.51 times the odds of developing SPTC compared to Hispanic children who had not received radiation therapy, [AOR=3.51, 99% CI: 0.69-17.70, p=0.04]. These findings support the development of age-specific guidelines for the use of radiation based interventions among children with and without cancer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For recycling of waste polymers, the degradation behavior of PP was studied with a combination of radiolysis and thermolysis methods. The results revealed that thermal degradation temperature of PP was significantly reduced when PP was irradiated in the presence of a zeolite. The irradiation-induced temperature reduction depended on the zeolite structure and composition, as well as on the morphology of the mixture. Identification of pyrolysis products indicated that, in the absence of zeolite, irradiation resulted only in a change of the product distribution but no formation of new compounds. In the presence of zeolite, however, a series of oxidized products were formed. In addition, the pyrolysis could be performed at a much lower temperature. (C) 1996 Elsevier Science Limited

Relevância:

100.00% 100.00%

Publicador:

Resumo:

New push-pull copolymers based on thiophene (donor) and benzothiadiazole (acceptor) units, poly[4,7-bis(3-dodecylthiophene-2-yl) benzothiadiazole-co- thiophene] (PT3B1) and poly[4,7-bis(3-dodecylthiophene-2-yl) benzothiadiazole-co-benzothiadiazole] (PT2B2), are designed and synthesized via Stille and Suzuki coupling routes respectively. Gel permeation chromatography shows the number average molecular weights are 31100 and 8400 g mol-1 for the two polymers, respectively. Both polymers have shown absorption throughout a wide range of the UV-vis region, from 300 to 650 nm. A significant red shift of the absorption edge is observed in thin films compared to solution of the copolymers; the optical band gap is in the range of 1.7 to 1.8 eV. Cyclic voltammetry indicates reversible oxidation and reduction processes with HOMO energy levels calculated to be in the range of 5.2 to 5.4 eV. Upon testing both materials for organic field-effect transistors (OFETs), PT3B1 showed a hole mobility of 6.1 × 10-4 cm2 V-1 s -1, while PT2B2 did not show any field effect transport. Both copolymers displayed a photovoltaic response when combined with a methanofullerene as an electron acceptor. The best performance was achieved when the copolymer PT3B1 was blended with [70]PCBM in a 1:4 ratio, exhibiting a short-circuit current of 7.27 mA cm-2, an open circuit voltage of 0.85 V, and a fill factor of 41% yielding a power conversion efficiency of 2.54% under simulated air mass (AM) 1.5 global (1.5 G) illumination conditions (100 mW cm-2). Similar devices utilizing PT2B2 in place of PT3B1 demonstrated reduced performance with a short-circuit current of 4.8 mA cm -2, an open circuit voltage of 0.73 V, and a fill factor of 30% resulting in a power conversion efficiency of roughly 1.06%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Shrinkage, retractive stress, and infrared dichroism of the drawn low-density polyethylene (LDPE) as-drawn and irradiated by Co-60-ray have been measured under different annealing conditions. The shrinkage and the disorientation of the irradiated sample was undergone more rapidly than that of unirradiated one as the temperature was continuously increased, surpassing a certain value, and a higher degree of shrinkage and disorientation was achieved finally for the irradiated sample when the samples were annealed with free ends. For the samples heated isothermally with fixed ends, the retractive stress went through a maximum and then attenuated to a limited value, and the degree of such a stress attenuation for the unirradiated sample was much more than that for the irradiated sample. These results show that the taut tie molecules (TTMs) in drawn PE can relax by the pulling of chain segments out of crystal blocks that they anchored in at elevated temperatures higher than the a transition and also by the displacing of microfibrils if the samples were annealed with free ends. The cross-links produced by irradiation prohibit the former process. It was further observed that the dependence of the average extinction coefficient of the band at 2016 cm-1 on that of the band at 1894 cm-1 is related to irradiation and annealing conditions, which has also been explained by the relaxation of TTMs and the function of irradiation-induced cross-linking on the relaxation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The goal of this project was to see if using IMRT to deliver elective pelvic nodal irradiation (EPNI) for prostate cancer reduced acute treatment toxicity.

Methods: Two hundred and thirty patients were enrolled into prospective trials delivering EPNI with a concomitant hypofractionated IMRT boost to the prostate. During accrual, the method of EPNI delivery changed as new literature emerged. Three methods were used (1) 4FB, (2) IMRT with 2 cm CTV margins around the pelvic vessels as suggested by Shih et al. (2005) [7] (IMRT-Shih), and (3) IMRT with nodal volumes suggested by the RTOG (IMRT-RTOG). Initially patients were treated with an empty bladder, with the remainder treated with bladder full.

Results: Patients in the 4FB group had higher rates of grade 2 acute GI toxicities compared to the IMRT-Shih and IMRT-RTOG groups (31.9% vs 20.8% vs 7.2%, p = 0.0009). Patients in the 4FB group had higher rates of grade 3 urinary frequency compared to the two IMRT groups (8.5% vs 0% vs 0%, p = 0.027). However, multivariate analysis suggested the factor that most influenced toxicity was bladder filling followed by IMRT.

Conclusions: Bladder filling appeared to be the dominant factor which predicted for acute toxicity, followed by the use of IMRT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cylinders (3.5 x 5.0 mm) of the reline resins Kooliner (K), New Truliner (N), Tokuso Rebase Fast (T), and Ufi Gel Hard (U) were bonded to cylinders (20 x 20 mm) of the denture base resin Lucitone 550 (L), and samples were divided into two controls and four test groups (n = 8). Shear tests (0.5 mm/min) were performed after polymerization or immersion in water (37 degrees C) for 7 days (controls); two or seven cycles of disinfection by immersion in sodium perborate (50 degrees C/10 min) or microwave irradiation (650 W/6 min). Statistical analyses (alpha = 0.05) revealed that two cycles of microwave and chemical disinfection increased the mean bond strengths of materials T (9.08 to 12.93 MPa) and L (18.89 to 23.02 MPa). For resin L, seven cycles of chemical (15.72 MPa) and microwave (17.82 MPa) disinfection decreased the shear bond strength compared with the respective control (21.74 MPa). Resins U (13.12 MPa), K (8.44 MPa), and N (7.98 MPa) remained unaffected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of radiotherapy on the radiopacity and flexural strength of composite resin. Forty Z250 composite resin specimens were polymerized using a halogen light-curing unit and divided into 5 groups, in accordance with the radiotherapy dose: G1- without irradiation, G2- 30 Gy, G3- 40 Gy, G4- 50 Gy and GS- 60 Gy Digital images were obtained using a GE 100 X-ray. Radiopacity values were obtained with the Digora digital imaging system and the flexural strength was evaluated with an EMIC universal testing machine. Data were submitted to ANOVA and Tukey 's test. G1 presented the highest radiopacity value, followed by G3, G5, G4 and G2. For flexural strength, G1 presented the lowest value, followed by G2, G5, G3 and G4. Differences were no significant (p>0.05). The commonly used dosage of radiotherapy treatment, did not cause alteration in the radiopacity and flexural strength of resin-based composites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

At head of title: The University of Michigan, College of Engineering, Dept. of Chemical and Metallurgical Engineering. Final report.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Category No. UC-4 ; Chemistry ; TID-4500."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two reactive comonomers, divinyl benzene (DVB) and trimethylolpropane triacrylate (TRIS), were evaluated for their role in effecting the melt free radical grafting reaction of the monomer glycidyl methacrylate (GMA) onto polypropylene (PP). The characteristics of the GMA-grafting systems in the presence and absence of DVB or TRIS were examined and compared in terms of the yield of the grafting reaction and the extent of the main side reactions, namely homopolymerisation of GMA (poly-GMA) and polymer degradation, using different chemical compositions of the reactive systems and processing conditions. In the absence of the comonomers, i.e. in a conventional system, high initiator concentrations of peroxides were typically required to achieve the highest possible GMA grafting levels which were found to be generally low. Concomitantly, both poly-GMA and degradation of the polymer by chain scission takes place with increasing initiator amounts. On the other hand, the presence of a small amount of the comonomers, DVB or Tris, in the GMA-grafting system, was shown to bring about a significant increase in the grafting level paralleled by a large reduction in poly-GMA and PP degradation. In the presence of these highly reactive comonomers, the optimum grafting system requires a much lower concentration of the peroxide initiator and, consequently, would lead to the much lower degree of polymer degradation observed in these systems. The differences in the effects of the presence of DVB and that of TRIS in the grafting systems on the rate of the GMA-grafting and homopolymerisation reactions, and the extent of PP degradation (through melt flow changes), were compared and contrasted with a conventional GMA-grafting system.