1000 resultados para Pollard, R.


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Vacc-4x is a peptide-based HIV therapeutic vaccine to conserved domains on p24Gag. Recently conserved 'sectors' on HIV p24, critical for virus viability and thereby immunologically vulnerable have been identified. Elite controllers target immune responses to such regions. The Vacc-4x peptides lie within a number of these conserved sectors of HIV p24. The co-primary endpoints of this study were to compare changes in CD4 counts and return to ART between treatmentand placebo groups during a 24 week treatment interruption. Secondary endpoints included safety, viral load and immunogenicity.Methods: This prospective, randomized, double blind phase IIB clinical study (NCT00659789) was carried out in 13 European and 5 US centers recruiting 135 patients on ART. After 6 immunizations on ART over 28 weeks, treatment was interrupted for up to 24 weeks (to week 52) (Vacc-4x n = 88; placebo n = 38). Immunological analyses (ELISPOT, proliferation, intracellular cytokine staining) were carried out at central laboratories.Results: There were no Vacc-4x-related serious adverse events. Of the 135 patients recruited (male n = 92; female n = 43), 126 patients completed the study. Median prestudy CD4 count was 712 (Vacc-4x) and 619 cells/mm3 (placebo), and median CD4 nadir 300 (Vacc-4x) and 285 cells/mm3 (placebo). There was no statistically significant difference between the two groups regarding change in CD4 counts (p = 0.12) or ART resumption (p = 0.89) during treatment interruption. A statistically significant treatment difference between Vacc-4x and placebo groupsfor viral load (VL) was found for patients who achieved a 6 month ART-free period (p = 0.0022). There was a positive correlation between ELISPOT responses and lower viral load in the Vacc-4x group compared to placebo (p = 0.02). Long-term follow-up of patients up t o week 104 was completed in June 2011.Conclusion: Vacc-4x was found to be safe and well tolerated. TheVacc-4x group experienced a significant reduction in viral load compared to placebo.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Present combination antiretroviral therapy (cART) alone does not cure HIV infection and requires lifelong drug treatment. The potential role of HIV therapeutic vaccines as part of an HIV cure is under consideration. Our aim was to assess the efficacy, safety, and immunogenicity of Vacc-4x, a peptide-based HIV-1 therapeutic vaccine targeting conserved domains on p24(Gag), in adults infected with HIV-1. METHODS: Between July, 2008, and June, 2010, we did a multinational double-blind, randomised, phase 2 study comparing Vacc-4x with placebo. Participants were adults infected with HIV-1 who were aged 18-55 years and virologically suppressed on cART (viral load <50 copies per mL) with CD4 cell counts of 400 × 10(6) cells per L or greater. The trial was done at 18 sites in Germany, Italy, Spain, the UK, and the USA. Participants were randomly assigned (2:1) to Vacc-4x or placebo. Group allocation was masked from participants and investigators. Four primary immunisations, weekly for 4 weeks, containing Vacc-4x (or placebo) were given intradermally after administration of adjuvant. Booster immunisations were given at weeks 16 and 18. At week 28, cART was interrupted for up to 24 weeks. The coprimary endpoints were cART resumption and changes in CD4 counts during treatment interruption. Analyses were by modified intention to treat: all participants who received one intervention. Furthermore, safety, viral load, and immunogenicity (as measured by ELISPOT and proliferation assays) were assessed. The 52 week follow-up period was completed in June, 2011. For the coprimary endpoints the proportion of participants who met the criteria for cART resumption was analysed with a logistic regression model with the treatment effect being assessed in a model including country as a covariate. This study is registered with ClinicalTrials.gov, number NCT00659789. FINDINGS: 174 individuals were screened; because of slow recruitment, enrolment stopped with 136 of a planned 345 participants and 93 were randomly assigned to receive Vacc-4x and 43 to receive placebo. There were no differences between the two groups for the primary efficacy endpoints in those participants who stopped cART at week 28. Of the participants who resumed cART, 30 (34%) were in the Vacc-4x group and 11 (29%) in the placebo group, and percentage changes in CD4 counts were not significant (mean treatment difference -5·71, 95% CI -13·01 to 1·59). However, a significant difference in viral load was noted for the Vacc-4x group both at week 48 (median 23 100 copies per mL Vacc-4x vs 71 800 copies per mL placebo; p=0·025) and week 52 (median 19 550 copies per mL vs 51 000 copies per mL; p=0·041). One serious adverse event, exacerbation of multiple sclerosis, was reported as possibly related to study treatment. Vacc-4x was immunogenic, inducing proliferative responses in both CD4 and CD8 T-cell populations. INTERPRETATION: The proportion of participants resuming cART before end of study and change in CD4 counts during the treatment interruption showed no benefit of vaccination. Vacc-4x was safe, well tolerated, immunogenic, seemed to contribute to a viral-load setpoint reduction after cART interruption, and might be worth consideration in future HIV-cure investigative strategies. FUNDING: Norwegian Research Council GLOBVAC Program and Bionor Pharma ASA.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Englantilaisen tutkimusmatkaajan E. D. Clarken Ahvenanmeren ylitys joulukuussa 1799. - Digitoitu valokuvasta, joka julkaistu kirjassa: R. Knapas & P. Koistinen, Historiallisia kuvia, 1993.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

E. D. Clarken retkikunta lennätti kuumailmapalloa Enontekiöllä heinäkuussa 1799. - Digitoitu valokuvasta, joka julkaistu kirjassa: R. Knapas & P. Koistinen: Historiallisia kuvia, 1993.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new type of horn antenna for operation at 1.6 THz, that can be fabricated monolithically with 1/4-height micromachined waveguide, is described. Height, limitations imposed by the micromachining process are overcome by removing a tapered slot in the upper surface of a scalar horn, allowing the E-plane fields to extend outside the confines of the metallic structure before radiation, with a consequent reduction in E-plane beamwidth. 1.6 THz radiation pattern measurements for different designs show that, while there is scope for further optimisation, 3 dB beamwidths of 24 degrees and 17.5 degrees in the E- and H-planes, respectively, can be achieved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The fabrication and characterization of micromachined reduced-height air-filled rectangular waveguide components suitable for integration is reported in this paper. The lithographic technique used permits structures with heights of up to 100 μm to be successfully constructed in a repeatable manner. Waveguide S-parameter measurements at frequencies between 75-110 GHz using a vector network analyzer demonstrate low loss propagation in the TE10 mode reaching 0.2 dB per wavelength. Scanning electron microscope photographs of conventional and micromachined waveguides show that the fabrication technique can provide a superior surface finish than possible with commercially available components. In order to circumvent problems in efficiently coupling free-space propagating beams to the reduced-height G-band waveguides, as well as to characterize them using quasi-optical techniques, a novel integrated micromachined slotted horn antenna has been designed and fabricated, E-, H-, and D-plane far-field antenna pattern measurements at different frequencies using a quasi-optical setup show that the fabricated structures are optimized for 180-GHz operation with an E-plane half-power beamwidth of 32° elevated 35° above the substrate, a symmetrical H-plane pattern with a half-power beamwidth of 23° and a maximum D-plane cross-polar level of -33 dB. Far-field pattern simulations using HFSS show good agreement with experimental results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Schottky barrier diodes have been integrated into on-chip rectangular waveguides. Two novel techniques have been developed to fabricate diodes with posts suitable for integration into waveguides. One technique produces diodes with anode diameters of the order of microns with post heights from 90 to 125 microns and the second technique produces sub-micron anodes with post heights around 20 microns. A method has been developed to incorporate these structures into a rectangular waveguide and provide a top contact onto the anode which could be used as an I.F. output in a mixer circuit. Devices have been fabricated and D.C. characterized.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The first measurement of the relative permittivity (εr) and loss tangent (tan δ) of EPON™ SU-8 advanced thick film ultraviolet photoresist is reported at frequencies between 75–110 GHz (W-band). The problems associated with such a measurement are discussed, an error analysis given, and values of εr=1.725±0.08 and tanδ =0.02±0.001 are determined.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new technique is reported for micro-machining millimetre-wave rectangular waveguide components. S-parameter measurements on these structures show that they achieve lower loss than those produced using any other on-chip fabrication technique, have highly accurate dimensions, are physically robust, and are cheap and easy to manufacture.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel technique for micro-machining millimeter and submillimeter-wave rectangular waveguide components is reported. These are fabricated in two halves which simply snap together, utilizing locating pins and holes, and are physically robust, and cheap, and easy to manufacture. In addition, S-parameter measurements on these structures are reported for the first time and display lower loss than previously reported micro-machined rectangular waveguides.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este trabajo rastrea el tratamiento dado a las catego­as Actividad Física e Imagen Corporal en una selección de textos científicos del área de la salud; revisa la relación entre catego­as y examina si en dichos textos son abordadas desde el enfoque de los Determinantes Sociales de la Salud o desde el enfoque de la Determinación Social de la Salud, usando la catego­a de equidad como pa¡metro y explorando las implicaciones de ello. Su paradigma epistemológico es la construcción social del conocimiento y el eje metodológico el análisis de contenido. Los resultados muestran una construcción insipiente de las catego­as, una relación diversa entre ellas y un privilegio del enfoque de los determinantes sociales de la salud en los textos académicos. Finalmente, el trabajo indaga sobre las implicaciones p¡cticas mediante un análisis de contenido de dos documentos de la OMS. Se concluye que en la p¡ctica sí se reflejan las diferencias de enfoque.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most butterfly monitoring protocols rely on counts along transects (Pollard walks) to generate species abundance indices and track population trends. It is still too often ignored that a population count results from two processes: the biological process (true abundance) and the statistical process (our ability to properly quantify abundance). Because individual detectability tends to vary in space (e.g., among sites) and time (e.g., among years), it remains unclear whether index counts truly reflect population sizes and trends. This study compares capture-mark-recapture (absolute abundance) and count-index (relative abundance) monitoring methods in three species (Maculinea nausithous and Iolana iolas: Lycaenidae; Minois dryas: Satyridae) in contrasted habitat types. We demonstrate that intraspecific variability in individual detectability under standard monitoring conditions is probably the rule rather than the exception, which questions the reliability of count-based indices to estimate and compare specific population abundance. Our results suggest that the accuracy of count-based methods depends heavily on the ecology and behavior of the target species, as well as on the type of habitat in which surveys take place. Monitoring programs designed to assess the abundance and trends in butterfly populations should incorporate a measure of detectability. We discuss the relative advantages and inconveniences of current monitoring methods and analytical approaches with respect to the characteristics of the species under scrutiny and resources availability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The variation in the proportion of reproductive branches, fruit, and seed production of Ipomoea pes-caprae (L.) R. Br. (Convolvulaceae) were evaluated at ten beaches on Santa Catarina Island, state of Santa Catarina, Brazil. Three patches per beach of Ipomoea pes-caprae were monitored, involving two reproductive cycles. Ipomoea pes-caprae presented initially an average length of patches of 14 m, with 9.6 branches/m² and 39% of reproductive branches. The proportion of reproductive branches varied between the cycles, but there was not noticed an alternation of reproductive effort between the subsequent cycles. There was a reduction in the percentage of reproductive branches at six localities. In four beaches where Ipomoea pes-caprae populations declined, occurred reduction in the reproductive vigor, and in the seed production, being these declines associated to strong sea erosion. In another hand, in one beach with population increase, there were little reproductive branches due to the occurrence of young stolons. Four patches never maturated fruits, being three of these located at small beaches. The fruit and seed productions in the patches showed values up to 40 fruits/m² and up to 140 seeds/m², respectively. Populations with great seed production were localized in areas adjacent to great coastal plains, which may represent potential seed sources for areas with small seed production in the island.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uma análise da distribuição geog¡fica de Schefflera no Brasil extra-amazônico foi realizada com base em mapas atualizados plotando as ocorrências conhecidas das 26 espécies do gênero encontradas nessa grande área: S. angustissima (Marchal) Frodin, S. aurata Fiaschi, S. botumirimensis Fiaschi & Pirani, S. burchellii (Seem.) Frodin & Fiaschi, S. calva (Cham.) Frodin & Fiaschi, S. capixaba Fiaschi, S. cephalantha (Harms) Frodin, S. cordata (Taub.) Frodin & Fiaschi, S. distractiflora (Harms) Frodin, S. fruticosa Fiaschi & Pirani, S. gardneri (Seem.) Frodin & Fiaschi, S. glaziovii (Taub.) Frodin & Fiaschi, S. grandigemma Fiaschi, S. kollmannii Fiaschi, S. longipetiolata (Pohl ex DC.) Frodin & Fiaschi, S. lucumoides (Decne. & Planch. ex Marchal) Frodin & Fiaschi, S. macrocarpa (Cham. & Schltdl.) Frodin, S. malmei (Harms) Frodin, S. morototoni (Aubl.) Maguire, Steyermark & Frodin, S. racemifera Fiaschi & Frodin, S. ruschiana Fiaschi & Pirani, S. selloi (Marchal) Frodin & Fiaschi, S. succinea Frodin & Fiaschi, S. villosissima Fiaschi & Pirani, S. vinosa (Cham. & Schltdl.) Frodin & Fiaschi e S. aff. varisiana Frodin. Dois centros de endemismo associados com áreas de altitude elevada foram reconhecidos: Cadeia do Espinhaço em Minas Gerais e florestas montanas do Estado do Espírito Santo. Os padµes de distribuição geog¡fica ilustrados são discutidos com base em dados obtidos para outros grupos de angiospermas e em estudos fitogeog¡ficos das principais fitocórias do Brasil extra-amazônico. São apresentadas também hipóteses acerca de prováveis relações filogenéticas entre alguns táxons, visando à busca de possíveis correlações entre estas e a biogeografia do grupo.