19 resultados para Politetrafluoretileno


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestría en Ciencias Odontológicas con Especialidad en Periodoncia) UANL

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the possibility to obtaining guided bone regeneration utilizing a nonporous PTFE barrier in the osseointegrated implants, protruding from the bone level of the rabbit tíbia. The histologic characteristics of the interface between titanium implants, one group titanium-plasma coated, another group with acid-treated surfaces and the regenerated bone were also studied Twenty Screw-Vent implants were placed in tibias of five rabbits, two at the right side and two at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. ln the experimental side, the implants and adjacent bone were protected with a nonporous PTFE barrier. Histologic analysis after three months showed that all implants were in direct contact with the bane. Histologic measurements showed an average gain in bone height of the 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control defects, in the titanium plasma-spray and acid-treated implant surfaces, respectively. The results suggest that the placement of implants protruding 3 mm from crestal bone defects may result in vertical bone augmentation and the regenerated bone is able to osseointegrate implants. lt seems to be critical the use of the PTFE barrier when acid-treated surface implants are inserted

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os orifícios de acesso aos parafusos de retenção devem ser preenchidos para que o parafuso não seja danificado caso seja necessária a remoção da prótese. Dentre os materiais mais utilizados estão o algodão, a fita de politetrafluoretileno e a guta percha. O objetivo deste estudo é avaliar a formação de biofilme de Candida albicans nos materiais anteriormente descritos, buscando estabelecer um parâmetro que contribua para a escolha do tipo de material mais adequado a ser utilizado clinicamente. Foram utilizados UCLAs, análogos e parafusos sextavados, todos de titânio. Os conjuntos foram montados com torque de 32N. Os materiais foram condensados no interior dos UCLAs e colocados em meio de cultura com uma suspensão de 3x106 células/ml de Candida albicans. O sistema foi armazenado à 37C com agitação, por 15 dias e o meio foi renovado a cada 48 horas. A quantificação de biofilme foi realizada pelo ensaio de MTT e leitura à 490nm, resultando em diferentes valores de densidade óptica. A normalidade (p=0,304 - Kolmogorov-Smirnov) e a igualdade de variâncias (p=0,721 - Scheffe) foram testadas primeiramente. O teste de análise de variância demonstrou diferença significativa entre os grupos (p<0,001) e com o Holm-Sidak foi observada diferença significativa entre os grupos algodão e guta (p<0,05) e algodão e fita de politetrafluoetileno (p<0,05); não houve diferença significativa entre os grupos guta e fita de politatrafluoretileno (p>0,05), apesar dos valores da fita de politetrafluoetileno terem sido maiores. Considerando-se as limitações deste estudo in vitro, podemos concluir que tanto a guta-percha quanto a fita de politetrafluoretileno apresentaram menor formação de biofilme, não havendo diferença estatisticamente significativa entre os materiais. O algodão apresentou um nível de formação de biofilme significativamente maior que a fita de politetrafluoretileno e a guta percha. Diante disso, serão necessários novos estudos para confirmar as limitações que este tipo de material pode apresentar quando usado como material de preenchimento do acesso do parafuso da prótese sobre implante.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O espessamento intimal e a reestenose que ocorrem após os procedimentos de angioplastia transluminal percutânea e/ou o implante de stents representam uma causa freqüente de falência destes procedimentos. O principal achado patológico responsável pela reestenose parece ser a hiperplasia intimal, já que o dispositivo intravascular é resistente ao remodelamento arterial geométrico. O propósito deste estudo é avaliar, através da morfometria digital, o espessamento intimal presente nas regiões da parede arterial imediatamente proximal e distal ao implante de um stent metálico em configuração em “Z “ não recoberto ou recoberto com PTFE. Vinte e cinco suínos de raça mista, com seis a dez semanas de idade, pesando em média 20 kg foram divididos em três grupos. No grupo I, cinco animais foram submetidos à exposição cirúrgica retroperitoneal da aorta abdominal, aortotomia e manipulação com uma bainha introdutora de 12 F. O grupo II incluiu dez animais que foram submetidos ao implante de um stent metálico auto-expansível não recoberto. No grupo III, incluindo também dez animais, foram implantados stents recobertos com PTFE. Após quatro semanas, todos os animais foram sacrificados e o segmento aorto-ilíaco foi removido. Quatro animais foram excluídos do estudo por trombose da aorta (um animal do grupo II e três animais do grupo III). Para a análise morfométrica foram utilizados os testes não paramétricos de Wilcoxon e de Kruskal-Wallis, para as comparações, respectivamente, no mesmo grupo e entre os grupos. Foi adotado o nível de significância de 5% ( p< 0,05). Quando os espécimes da parede arterial, imediatamente proximal e distal aos stents foram comparados, nenhuma diferença estatisticamente significativa foi encontrada entre as áreas luminal, intimal, média ou índice intimal em cada grupo. Na comparação entre os grupos, as áreas intimal, média e o índice intimal não demonstraram variação estatisticamente significativa. Foram identificadas diferenças entre os grupos quanto às áreas luminais proximais (p = 0,036) e distais (p=0,044). Pelo teste de comparações múltiplas para Kruskal-Wallis (Teste de Dunn) identificou-se diferença significativa entre os grupos I e II. Entretanto, quando estas variáveis foram controladas pelo fator peso (relação área luminal/peso) a diferença não foi mais observada. Concluímos que, após quatro semanas, stents recobertos com PTFE induzem um espessamento intimal justa-stent similar ao observado com stents não recobertos ou com a simples manipulação arterial com uma bainha introdutora. Neste modelo experimental suíno, de curto seguimento, o revestimento com PTFE não foi responsável por adicional espessamento intimal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Present work proposed to map and features the wear mechanisms of structural polymers of engineering derived of the sliding contact with a metallic cylindrical spindle submitted to eccentricity due to fluctuations in it is mass and geometric centers. For this it was projected and makes an experimental apparatus from balancing machine where the cylindrical counterbody was supported in two bearings and the polymeric coupon was situated in a holder with freedom of displacement along counterbody. Thus, the experimental tests were standardized using two position of the two bearings (Fixed or Free) and seven different positions along the counterbody, that permit print different conditions to the stiffness from system. Others parameters as applied normal load, sliding velocity and distance were fixed. In this investigation it was used as coupon two structural polymers of wide quotidian use, PTFE (polytetrafluroethylene) and PEEK (poly-ether-ether-ketone) and the AISI 4140 alloy steel as counterbody. Polymeric materials were characterized by thermal analysis (thermogravimetric, differential scanning calorimetry and dynamic-mechanical), hardness and rays-X diffractometry. While the metallic material was submitted at hardness, mechanical resistance tests and metallographic analysis. During the tribological tests were recorded the heating response with thermometers, yonder overall velocity vibration (VGV) and the acceleration using accelerometers. After tests the wear surface of the coupons were analyzed using a Scanning Electronic Microscopy (SEM) to morphological analysis and spectroscopy EDS to microanalysis. Moreover the roughness of the counterbody was characterized before and after the tribological tests. It was observed that the tribological response of the polymers were different in function of their distinct molecular structure. It were identified the predominant wear mechanisms in each polymer. The VGV of the PTFE was smaller than PEEK, in the condition of minimum stiffness, in function of the higher loss coefficient of that polymer. Wear rate of the PTFE was more of a magnitude order higher than PEEK. With the results was possible developed a correlation between the wear rate and parameter (E/ρ)1/2 (Young modulus, E, density, ρ), proportional at longitudinal elastic wave velocity in the material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A regeneração periodontal e do rebordo ósseo utilizando barreiras físicas são procedimentos bem estabelecidos em cirurgias reconstrutivas. As características do biomaterial e o desenho da membrana empregados na regeneração tecidual guiada desempenham um papel importante na obtenção de bons resultados. O objetivo deste estudo experimental histológico foi comparar o uso de dois tipos de barreiras físicas na regeneração óssea guiada em defeitos criados na tíbia de ratos. Quinze animais foram divididos em três grupos: grupo I (barreira não-porosa de politetrafluoretileno), grupo II (blocos de hidroxiapatita de coral) e grupo III (controle que não recebeu nenhuma barreira). A análise histológica demonstrou várias quantidades de osso neoformado com ambos os tipos de barreiras. A barreira de politetrafluoretileno mostrou melhores resultados do que a hidroxiapatita. Os resultados deste estudo sugerem que a regeneração óssea pode ser conseguida com a técnica de submersão da barreira física.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Biopatologia Bucal - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este estudo comparou a resistência à compressão de uma resina composta e de um compômero, fotoativados com luz halógena convencional de quarto-tungstênio (QTH) (XL 300, 3M/SPE) e LED azul (SmartLite PS; Dentsply/De Trey). Foram confeccionados 40 espécimes em forma de disco usando uma matriz bipartida de politetrafluoretileno (4,0 mm de diâmetro x 8,0 mm de altura) em que o material foi inserido incrementalmente. O tempo de polimerização de cada incremento foi de 40 s para a luz halógena convencional e de 10 s para o LED. Os espécimes foram aleatoriamente alocados em 4 grupos (n=10), de acordo com a fonte de luz e com o material restaurador. Depois de armazenadas em água destilada a 37°C ± 2°C por 24 h, a resistência à compressão dos espécimes foi testada em uma máquina universal de ensaios com célula de carga de 500 kgf a uma velocidade de carregamento de 0,5 mm/min. Os dados (em MPa) foram analisados estatisticamente por ANOVA e teste de Student-Newman-Keuls (p<0,05). Para a resina composta, a fotopolimerização com luz halógena não produziu diferença estatisticamente significante (p>0,05) em sua resistência à compressão quando comparada à fotopolimerização com LED. Contudo, a fotopolimerização do compômero com a luz halógena resultou em uma resistência à compressão significativamente maior que a feita o LED (p>0,05). A resina composta apresentou resistência à compressão significativamente maior que a do compômero, independente da fonte de luz. Concluiu-se que a resistência à compressão dos materiais fotopolimerizados com luz halógena e LED foi influenciada pela densidade de energia empregada e pela composição química dos materiais restauradores estéticos.