854 resultados para Point-of-care


Relevância:

100.00% 100.00%

Publicador:

Resumo:

1st ASPIC International Congress

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes a novel use for the polymeric film, poly(o-aminophenol) (PAP) that was made responsive to a specific protein. This was achieved through templated electropolymerization of aminophenol (AP) in the presence of protein. The procedure involved adsorbing protein on the electrode surface and thereafter electroploymerizing the aminophenol. Proteins embedded at the outer surface of the polymeric film were digested by proteinase K and then washed away thereby creating vacant sites. The capacity of the template film to specifically rebind protein was tested with myoglobin (Myo), a cardiac biomarker for ischemia. The films acted as biomimetic artificial antibodies and were produced on a gold (Au) screen printed electrode (SPE), as a step towards disposable sensors to enable point-of-care applications. Raman spectroscopy was used to follow the surface modification of the Au-SPE. The ability of the material to rebind Myo was measured by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The devices displayed linear responses to Myo in EIS and SWV assays down to 4.0 and 3.5 μg/mL, respectively, with detection limits of 1.5 and 0.8 μg/mL. Good selectivity was observed in the presence of troponin T (TnT) and creatine kinase (CKMB) in SWV assays, and accurate results were obtained in applications to spiked serum. The sensor described in this work is a potential tool for screening Myo in point-of-care due to the simplicity of fabrication, disposability, short time response, low cost, good sensitivity and selectivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For many drugs, finding the balance between efficacy and toxicity requires monitoring their concentrations in the patient's blood. Quantifying drug levels at the bedside or at home would have advantages in terms of therapeutic outcome and convenience, but current techniques require the setting of a diagnostic laboratory. We have developed semisynthetic bioluminescent sensors that permit precise measurements of drug concentrations in patient samples by spotting minimal volumes on paper and recording the signal using a simple point-and-shoot camera. Our sensors have a modular design consisting of a protein-based and a synthetic part and can be engineered to selectively recognize a wide range of drugs, including immunosuppressants, antiepileptics, anticancer agents and antiarrhythmics. This low-cost point-of-care method could make therapies safer, increase the convenience of doctors and patients and make therapeutic drug monitoring available in regions with poor infrastructure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hypoglycemia, if recurrent, may have severe consequences on cognitive and psychomotor development of neonates. Therefore, screening for hypoglycemia is a daily routine in every facility taking care of newborn infants. Point-of-care-testing (POCT) devices are interesting for neonatal use, as their handling is easy, measurements can be performed at bedside, demanded blood volume is small and results are readily available. However, such whole blood measurements are challenged by a wide variation of hematocrit in neonates and a spectrum of normal glucose concentration at the lower end of the test range. We conducted a prospective trial to check precision and accuracy of the best suitable POCT device for neonatal use from three leading companies in Europe. Of the three devices tested (Precision Xceed, Abbott; Elite XL, Bayer; Aviva Nano, Roche), Aviva Nano exhibited the best precision. None completely fulfilled the ISO-accuracy-criteria 15197: 2003 or 2011. Aviva Nano fulfilled these criteria in 92% of cases while the others were <87%. Precision Xceed reached the 95% limit of the 2003 ISO-criteria for values ≤4.2 mmol/L, but not for the higher range (71%). Although validated for adults, new POCT devices need to be specifically evaluated on newborn infants before adopting their routine use in neonatology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les POCT (point of care tests) ont un grand potentiel d'utilisation en médecine infectieuse ambulatoire grâce à leur rapidité d'exécution, leur impact sur l'administration d'antibiotiques et sur le diagnostic de certaines maladies transmissibles. Certains tests sont utilisés depuis plusieurs années (détection de Streptococcus pyogenes lors d'angine, anticorps anti-VIH, antigène urinaire de S. pneumoniae, antigène de Plasmodium falciparum). De nouvelles indications concernent les infections respiratoires, les diarrhées infantiles (rotavirus, E. coli entérohémorragique) et les infections sexuellement transmissibles. Des POCT, basés sur la détection d'acides nucléiques, viennent d'être introduits (streptocoque du groupe B chez la femme enceinte avant l'accouchement et la détection du portage de staphylocoque doré résistant à la méticilline). POCT have a great potential in ambulatory infectious diseases diagnosis, due to their impact on antibiotic administration and on communicable diseases prevention. Some are in use for long (S. pyogenes antigen, HIV antibodies) or short time (S. pneumoniae antigen, P. falciparum). The additional major indications will be community-acquired lower respiratory tract infections, infectious diarrhoea in children (rotavirus, enterotoxigenic E. coli), and hopefully sexually transmitted infections. Easy to use, these tests based on antigen-antibody reaction allow a rapid diagnosis in less than one hour; the new generation of POCT relying on nucleic acid detection are just introduced in practice (detection of GBS in pregnant women, carriage of MRSA), and will be extended to many pathogens

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cardiac troponins (cTn) I and T are the current golden standard biochemical markers in the diagnosis and risk stratification of patients with suspected acute coronary syndrome. During the past few years, novel assays capable of detecting cTn‐concentrations in >50% of apparently healthy individuals have become readily available. With the emerging of these high sensitivity cTn assays, reductions in the assay specificity have caused elevations in the measured cTn levels that do not correlate with the clinical picture of the patient. The increased assay sensitivity may reveal that various analytical interference mechanisms exist. This doctoral thesis focused on developing nanoparticle‐assisted immunometric assays that could possibly be applied to an automated point‐of‐care system. The main objective was to develop minimally interference‐prone assays for cTnI by employing recombinant antibody fragments. Fast 5‐ and 15‐minute assays for cTnI and D‐dimer, a degradation product of fibrin, based on intrinsically fluorescent nanoparticles were introduced, thus highlighting the versatility of nanoparticles as universally applicable labels. The utilization of antibody fragments in different versions of the developed cTnI‐assay enabled decreases in the used antibody amounts without sacrificing assay sensitivity. In addition, the utilization of recombinant antibody fragments was shown to significantly decrease the measured cTnI concentrations in an apparently healthy population, as well as in samples containing known amounts of potentially interfering factors: triglycerides, bilirubin, rheumatoid factors, or human anti‐mouse antibodies. When determining the specificity of four commercially available antibodies for cTnI, two out of the four cross‐reacted with skeletal troponin I, but caused crossreactivity issues in patient samples only when paired together. In conclusion, the results of this thesis emphasize the importance of careful antibody selection when developing cTnI assays. The results with different recombinant antibody fragments suggest that the utilization of antibody fragments should strongly be encouraged in the immunoassay field, especially with analytes such as cTnI that require highly sensitive assay approaches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Point-of-care (POC) –diagnostics is a field with rapidly growing market share. As these applications become more widely used, there is an increasing pressure to improve their performance to match the one of a central laboratory tests. Lanthanide luminescence has been widely utilized in diagnostics because of the numerous advantages gained by the utilization of time-resolved or anti-Stokes detection. So far the use of lanthanide labels in POC has been scarce due to limitations set by the instrumentation required for their detection and the shortcomings, e.g. low brightness, of these labels. Along with the advances in the research of lanthanide luminescence, and in the field of semiconductors, these materials are becoming a feasible alternative for the signal generation also in the future POC assays. The aim of this thesis was to explore ways of utilizing time-resolved detection or anti-Stokes detection in POC applications. The long-lived fluorescence for the time-resolved measurement can be produced with lanthanide chelates. The ultraviolet (UV) excitation required by these chelates is cumbersome to produce with POC compatible fluorescence readers. In this thesis the use of a novel light-harvesting ligand was studied. This molecule can be used to excite Eu(III)-ions at wavelengths extending up to visible part of the spectrum. An enhancement solution based on this ligand showed a good performance in a proof-of-concept -bioaffinity assay and produced a bright signal upon 365 nm excitation thanks to the high molar absorptivity of the chelate. These features are crucial when developing miniaturized readers for the time-resolved detection of fluorescence. Upconverting phosphors (UCPs) were studied as an internal light source in glucose-sensing dry chemistry test strips and ways of utilizing their various emission wavelengths and near-infrared excitation were explored. The use of nanosized NaYF :Yb3+,Tm3+-particles enabled the replacement of an external UV-light source with a NIR-laser and gave an additional degree of freedom in the optical setup of the detector instrument. The new method enabled a blood glucose measurement with results comparable to a current standard method of measuring reflectance. Microsized visible emitting UCPs were used in a similar manner, but with a broad absorbing indicator compound filtering the excitation and emission wavelengths of the UCP. This approach resulted in a novel way of benefitting from the non-linear relationship between the excitation power and emission intensity of the UCPs, and enabled the amplification of the signal response from the indicator dye.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Termiä sepsis käytetään infektion aiheuttamasta yleisestä tulehdusreaktio-oireyhtymästä. Biokemiallinen merkkiaine eli biomarkkeri on aine, joka objektiivisesti mitattuna ja arvioituna toimii indikaattorina erottaen toisistaan normaalit biologiset prosessit ja patogeeniset prosessit. Lisäksi biomarkkeri saattaa osoittaa farmakologisen vasteen lääkehoidolle. Tutkielman kirjallisessa osassa on esitelty ja verrattu toisiinsa jo kliinisessä käytössä olevia sekä lupaavia, vielä tutkimusvaiheessa olevia, sepsiksen biomerkkiaineita. Lisäksi tutkielmassa on tarkasteltu sepsiksen todentamisen, tunnistamisen ja hoidon tulevaisuudennäkymiä. Prokalsitoniini (PCT) on eräs jo kliinisessä käytössä oleva sepsiksen biomerkkiaine. Tutkielman kokeellisessa osassa pystytettiin teho-osastoille suunnattu pikatesti PCT:n mittaamiseen aikaerotteista fluoresenssiteknologiaa hyödyntävälle AQT-järjestelmälle (DHR Finland Oy, Innotrac Diagnostics, Suomi). Järjestelmä mittaa 20–30 minuutissa biomerkkiainepitoisuuden. Tavoitteena oli löytää sopiva vasta-ainepari ja pystyttää kaksipuoleinen immunomääritys, jonka analyyttinen herkkyys on alle 0,02 ng/ml:ssa. Työssä tutkittiin biotinyloidun kokonaisen vasta-aineen ja paikkaspesifisesti biotinyloidun antigeenia sitovan fragmentin (engl. fragment antigen binding, Fab) toimivuutta sitojamolekyylinä. Lisäksi työssä verrattiin kahden eri leimamolekyylin, 9 hampaisen europiumkelaatin sekä Innotracissa kehitetyn tähtikelaatin, toimivuutta PCT-immunomäärityksessä. Vasta-aineiden mahdolliset ristireaktiot testattiin ja määritystä testattiin alustavasti eri näytematriiseissa. Työssä löydettiin 5 vasta-aineparia, joiden analyyttinen herkkyys oli alle 0,02 ng/ml:ssa. Aiemmin testattuja vasta-ainepareja parempi analyyttinen herkkyys johtui todennäköisesti yhden uuden leimavasta-aineen paremmasta affiniteetistä. Tähtikelaatilla leimatulla vasta-aineella analyyttinen herkkyys parani lähes viisinkertaisesti, kun sitä verrattiin 9-hampaisella euroopiumkelaatilla leimatun vasta-aineen määritykseen. Havaittiin myös, että Fab-fragmentilla mitattiin määrityksissä lähes kaksi kertaa suuremmat signaali-taustasuhteet, kun sitä verrattiin kokonaiseen vasta-aineeseen, tietyllä vasta-aineparilla. Tämä johtui luultavasti steeristen esteiden vähenemisestä. Näytematriisilla ei todettu olevan vaikutusta määritykseen, eikä ristireaktioita havaittu. Kehitetyn määrityksen suoriutumista verrattiin markkinoilla olevaan BRAHMS AG:n (Saksa) PCT-määritykseen käyttäen potilasnäytteitä. Korrelaatiokertoimet potilasnäytevertailuissa olivat 0,965–0,989 ja näytteiden mitatuissa pitoisuuksissa oli tasoero.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The full blood cell (FBC) count is the most common indicator of diseases. At present hematology analyzers are used for the blood cell characterization, but, recently, there has been interest in using techniques that take advantage of microscale devices and intrinsic properties of cells for increased automation and decreased cost. Microfluidic technologies offer solutions to handling and processing small volumes of blood (2-50 uL taken by finger prick) for point-of-care(PoC) applications. Several PoC blood analyzers are in use and may have applications in the fields of telemedicine, out patient monitoring and medical care in resource limited settings. They have the advantage to be easy to move and much cheaper than traditional analyzers, which require bulky instruments and consume large amount of reagents. The development of miniaturized point-of-care diagnostic tests may be enabled by chip-based technologies for cell separation and sorting. Many current diagnostic tests depend on fractionated blood components: plasma, red blood cells (RBCs), white blood cells (WBCs), and platelets. Specifically, white blood cell differentiation and counting provide valuable information for diagnostic purposes. For example, a low number of WBCs, called leukopenia, may be an indicator of bone marrow deficiency or failure, collagen- vascular diseases, disease of the liver or spleen. The leukocytosis, a high number of WBCs, may be due to anemia, infectious diseases, leukemia or tissue damage. In the laboratory of hybrid biodevices, at the University of Southampton,it was developed a functioning micro impedance cytometer technology for WBC differentiation and counting. It is capable to classify cells and particles on the base of their dielectric properties, in addition to their size, without the need of labeling, in a flow format similar to that of a traditional flow cytometer. It was demonstrated that the micro impedance cytometer system can detect and differentiate monocytes, neutrophils and lymphocytes, which are the three major human leukocyte populations. The simplicity and portability of the microfluidic impedance chip offer a range of potential applications in cell analysis including point-of-care diagnostic systems. The microfluidic device has been integrated into a sample preparation cartridge that semi-automatically performs erythrocyte lysis before leukocyte analysis. Generally erythrocytes are manually lysed according to a specific chemical lysis protocol, but this process has been automated in the cartridge. In this research work the chemical lysis protocol, defined in the patent US 5155044 A, was optimized in order to improve white blood cell differentiation and count performed by the integrated cartridge.