962 resultados para Pluma de contaminação


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among the potentially polluting economic activities that compromise the quality of groundwater are the gas stations. The city of Natal has about 120 gas stations, of which only has an environmental license for operation. Discontinuities in the offices were notified by the Public Ministry of Rio Grande do Norte to carry out the environmental adaptations, among which is the investigation of environmental liabilities. The preliminary and confirmatory stages of this investigation consisted in the evaluation of soil gas surveys with two confirmatory chemical analysis of BTEX, PAH and TPH. To get a good evaluation and interpretation of results obtained in the field, it became necessary three-dimensional representation of them. We used a CAD software to graph the equipment installed in a retail service station fuel in Natal, as well as the plumes of contamination by volatile organic compounds. The tool was concluded that contamination is not located in the current system of underground storage of fuel development, but reflects the historical past in which tanks were removed not tight gasoline and diesel

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work is the application of geophysical methods, using the Ground Penetrating Radar (GPR), with the objective of survey in a subsurface plume of contamination caused by a disabled gas station. The gas station is located on the Búzios beach in southern coast of the state to Rio Grande do Norte in an Area of Environmental Protection called Bonfim-Guaraíra. The interest to develop this work was the presence of contaminants (hydrocarbons) in a well located on the desktop, previously used for the abstraction of groundwater for residents living near the site. Were raised 15 geophysical survey lines totaling 775,48 lifting and installed 4 piezometer, to confirm the contamination and prepare a pluviometric map that helped in indicating the direction of local groundwater flow, thus showing the direction of movement of the probably plume of contamination. From the processing of the GPR lines was possible to identify two likely phases of contamination according to the classification proposed by Azambuja et al 2000, which are called phase absorbed and dissolved phase

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O monitoramento da atenuação natural em áreas contaminadas tem se mostrado uma técnica alternativa e de baixo custo para a remediação de áreas contaminadas. A degradação por microorganismos é um dos processos mais importantes na atenuação natural de contaminantes, especialmente compostos de fase líquida não aquosa (NAPL). em muitos casos, a ação efetiva deste processo resulta na geração de ácidos orgânicos, que sob elevadas concentrações ocasionam a dissolução de minerais presentes em subsuperfície onde se encontra a contaminação, com conseqüente liberação de íons. O aumento na quantidade de íons colabora para o aumento da condutividade elétrica do meio. O princípio físico da técnica de Radar de Penetração no Solo (GPR) é a emissão de ondas eletromagnéticas de alta freqüência. A propagação da onda eletromagnética é condicionada à freqüência de sinal emitido e as propriedades elétricas do meio. O aumento da condutividade elétrica do meio resulta na atenuação do sinal e, por conseqüência, na diminuição da profundidade de penetração da onda eletromagnética. Este fator permite o monitoramento de áreas contaminadas sob atenuação natural a partir de análises temporais com o GPR. Este trabalho apresenta um estudo comparativo entre perfis de GPR adquiridos em 1998 e 2003 em uma área contaminada por compostos de fase líquida leve não aquosa (LNAPL), sob atenuação natural. Os resultados indicam um aumento da condutividade elétrica do meio, a partir da atenuação acentuada do sinal GPR observada nas seções de 2003. Este aumento pode estar associado à liberação de íons por dissolução de minerais, pelo ataque de ácidos orgânicos resultantes do processo de biodegradação.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several factors have contributed to the increase the world production of urban solid waste, resulting in difficulties to the correct management and the final environmentally appropriate disposal, in addition to causing serious socio-economic, environmental, and public health troubles. The soil and groundwater contamination by leachate in waste disposal sites is almost always present, leveraging the emergence and/or adaptation of methodologies for environmental assessment of these areas. The geophysical methods, especially the electrical resistivity method, are fast, reliable and low-cost alternative for this purpose. This paper reports the methodology adopted for the temporal monitoring of the plume of contamination of controlled landfill in the municipality of Rio Claro (SP). Electrical resistivity data were obtained in 1999 and 2008, by the resistivity method, using the techniques of vertical electrical sounding and electrical profile. In both years, similar tests were carried out in the same locations within the disposal area. The results indicated that the plume of contamination has resistivity values less than or equal to 50 ohm.m and moves guided by 2 flows: the main, to the southeast, and the secondary, to the west. Relatively to the first series of tests in 1999, the plume of contamination was higher and deeper in 2008, contrary to what was expected for a landfill deactivated for at least 10 years.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho consistiu na investigação geofísica da possível contaminação de um posto de combustíveis em Belém-PA, bem como no desenvolvimento de um simulador geofísico para fins educativos. A investigação consistiu no levantamento de 13 perfis com o método geofísico eletromagnético Ground Penetrating Radar (GPR). Os radargramas obtidos, conjuntamente com os dados pré-existentes de sondagens mecânicas, Volatile Organics Compounds (VOC) e Benzeno-Tolueno-Etil-benzeno-Xileno (BTEX), permitiram identificar zonas de baixa reflexão do sinal eletromagnético (zonas atenuadas) em áreas com predominância de areia, o que indicaria contaminação. Como as medidas de GPR foram repetidas no período chuvoso, foi possível observar a redução da atenuação em perfil rico em areia, indicando a lixiviação dos ácidos graxos oriundos da biodegradação dos hidrocarbonetos, bem como o aumento da atenuação provocada pela argila, devido a sua elevada porosidade, e também, possivelmente, pelo aumento da biodegradação dos hidrocarbonetos que ficam retidos na argila. Este resultado constitui o primeiro caso inserido no simulador geofísico, experimento que permite mostrar o uso de diferentes métodos geofísicos. O simulador possui duas telas computacionais, a debaixo para simulação do modelo de subsuperfície escolhido e, a tela de cima, para representação da resposta geofísica obtida com o auxílio de uma unidade ótica que percorre o perfil representado na tela debaixo. Trata-se de uma modelagem analógica com recursos computacionais ainda não reportada na literatura, que permitirá mostrar diversos casos investigados constantes em dissertações e teses. O simulador poderá ser deslocado para empresas, universidades e secretarias, que fazem ou podem fazer uso da Geofísica, além de praças, escolas, etc., contribuindo de forma incisiva para a difusão da Geofísica como ferramenta na gestão de áreas contaminadas bem como para chamar a atenção da população para diferentes tipos de problemas, de modo a instruí-la sobre os mesmos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among the potentially polluting economic activities that compromise the quality of groundwater are the gas stations. The city of Natal has about 120 gas stations, of which only has an environmental license for operation. Discontinuities in the offices were notified by the Public Ministry of Rio Grande do Norte to carry out the environmental adaptations, among which is the investigation of environmental liabilities. The preliminary and confirmatory stages of this investigation consisted in the evaluation of soil gas surveys with two confirmatory chemical analysis of BTEX, PAH and TPH. To get a good evaluation and interpretation of results obtained in the field, it became necessary three-dimensional representation of them. We used a CAD software to graph the equipment installed in a retail service station fuel in Natal, as well as the plumes of contamination by volatile organic compounds. The tool was concluded that contamination is not located in the current system of underground storage of fuel development, but reflects the historical past in which tanks were removed not tight gasoline and diesel

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Pós-graduação em Geociências e Meio Ambiente - IGCE

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O descarte indevido de resíduos industriais no solo tem causado danos ao meio ambiente e à saúde humana. A identificação e o diagnóstico de áreas contaminadas é um procedimento necessário afim de que seja possível tomar medidas de contenção da fonte poluidora e posterior remediação. As técnicas geofísicas podem auxiliar na caracterização do meio geológico, definição das dimensões da pluma de contaminação, seleção de pontos para locação de poços de monitoramento e de bombeamento. Este trabalho apresenta os resultados da aplicação do método Eletromagnético Indutivo em uma área industrial contaminada por benzeno, tolueno, xileno (BTX) e dicloroetano. Os resultados indicam dois padrões de migração dos contaminantes em subsuperfície. Uma tendência de migração no plano horizontal até o nível de 15 m de profundidade e uma tendência de migração no plano vertical entre 15 e 60 m de profundidade. As tendências de migração divergentes estão condicionadas a densidade dos compostos que constituem a pluma de contaminação, ou seja, um intervalo LNAPL sobrenadante (BTX), sobreposto a um intervalo DNAPL (1,2 dicloroetano).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O uso combinado de poços de amostragem e técnicas geofísicas constitui a maneira mais adequada para identificação e o monitoramento de áreas contaminadas. Este procedimento permite a locação de poços de amostragem e de monitoramento em pontos estratégicos, otimizando resultados e minimizando gastos. O método geofísico Eletromagnético Indutivo (EM) apresenta amplas possibilidades de aplicação em estudos ambientais devido à facilidade na aquisição de dados, versatilidade do equipamento em campo e a possibilidade de varredura de grandes áreas num curto espaço de tempo. Este trabalho realiza uma análise comparativa de dados em obtidos no ano de 1992 e em 2003. O local estudado é uma área industrial que apresenta contaminação do solo e água subterrânea por Benzeno, Tolueno, Xileno, 1,2 dicloroetano, Sódio e Cloreto, produto da infiltração de efluentes químicos diretamente do solo. Os resultados indicam uma acentuada atenuação da pluma contaminante, com provável redução no grau de contaminação. Os compostos de fase leve (LNAPLs) apresentaram maior tendência de migração horizontal, concomitante ao movimento da água subterrânea. Os compostos de fase densa (DNAPLs) apresentaram uma tendência mais acentuada de migração no sentido vertical, possivelmente devido à ausência de superfícies impermeáveis. Os compostos inorgânicos acompanharam o fluxo dos compostos de fase líquida não aquosa (NAPLs), o que por sua vez permitiu a caracterização da pluma de contaminação como um corpo condutivo em relação às áreas adjacentes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Foi desenvolvido um estudo da subsuperfície rasa para investigar a possibilidade de contaminação do subsolo por líquidos usados no tratamento de couros. O estudo foi realizado na área da indústria Couro do Norte, Bairro de Maracacuera, no Distrito Industrial de Icoaraci em Belém-PA. As metodologias geofísicas utilizadas foram: eletrorresistividade (na forma de imageamento e através de sondagens verticais), potencial espontâneo, eletromagnético (slingram) e radar de penetração no solo (GPR). A interpretação conjunta dos dados geofísicos indicou a direção do fluxo subterrâneo e uma pluma de contaminação rasa na área do estudo causada provavelmente pelo despejo dos efluentes do curtume Couro do Norte.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Foi desenvolvido um estudo da subsuperfície rasa para investigar a possibilidade de contaminação do subsolo por líquidos usados no tratamento de couros em área industrial. O estudo foi realizado na área da indústria Couro do Norte, Bairro de Maracacuera, no Distrito Industrial de Icoaraci (município de Belém-Pará). Durante o estudo foram feitas medidas para a determinação do fluxo de água do primeiro aqüífero e aplicada metodologia geofísica com a finalidade de detectar a possível contaminação do subsolo por poluentes liberados pelo curtume. As metodologias geofísicas utilizadas foram: eletrorresistividade (na forma de imageamento e través de sondagens verticais), potencial espontâneo, eletromagnético (Slingram) e radar de penetração no solo (GPR). A interpretação dos dados eletromagnéticos permitiu identificar a presença de zonas mais condutivas (provável pluma de contaminação) e zonas mais resistivas (blocos lateríticos). A distribuição dos potenciais medidos através do Método do Potencial Espontâneo indicou o sentido do fluxo subterrâneo local. Com as Sondagens Elétricas Verticais determinaram-se os valores de resistividade em subsuperfície para os diferentes horizontes correlacionando-os sempre com as informações obtidas no Caminhamento Elétrico. Através dos dados de GPR identificou-se a presença de blocos lateríticos, tubulações de metal e zonas com elevada atenuação (zona de sombra) que indicam a presença de contaminação.