255 resultados para Piezocone de resistividade
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
A site investigation program was carried out to detect salt-water intrusions in a shallow sedimentary aquifer based on electrical resistivity measurements. The site is located close to Paranaguá harbor, in the Paraná State, Brasil. At this site, high chloride concentration contaminated shallow water wells used to supply water for local industries. The site investigation program included a fieldwork, dipole-dipole electrical profiling, resistivity piezocone tests, physical-chemical analysis of sampled water and interpretation of borehole logs. The resistivity piezocone tests provided two simultaneous information; the soil stratigraphy at a very detailed level and a quasi-continuous resistivity profile. Both information adequately complemented dipole-dipole electrical profiling test data. The integration of all test data allowed identifying the contaminated areas as well as guided the location of new water wells to be installed in this area.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Dissertação apresentada à Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Geológica(Georrecursos)
Resumo:
A resistividade elétrica é uma propriedade associada tanto a características físicas como químicas do betão, permitindo avaliar a maior ou menor dificuldade de penetração dos agentes agressivos no seu interior antes de iniciado o processo de despassivação e consequente corrosão das armaduras. Este trabalho aborda as propriedades de permeabilidade, correlacionando-as com a resistividade elétrica, de betão auto-compactável (BAC) com diferentes tipos e quantidades de adições. Para esse efeito, foram produzidas misturas binárias e ternárias de BAC com recurso a cinzas volantes (CV) e fíler calcário (FC). Produziu-se um total de 11 misturas auto-compactáveis: uma só com cimento (C); três com C+CV em 30, 60 e 70% de substituição; três com C+FC em 30, 60 e 70% de substituição; quatro com C+CV+FC em combinações de 10-20, 20-10, 20-40 e 40-20% de substituição respetivamente; e, por fim, quatro misturas de acordo com as especificações LNEC E 464 em referência à norma NP EN 206-1. A avaliação da permeabilidade dos betões produzidos foi feita através do ensaio de determinação da absorção de água por capilaridade de acordo com a especificação LNEC E 393. A resistividade elétrica foi avaliada recorrendo à proposta de norma europeia apresentada pelo EU-Project CHLORTEST (EU funded research Project under 5FP GROWTH programme) e com base na recomendação técnica RILEM TC-154 EMC. Os resultados obtidos indicam que as propriedades de permeabilidade do BAC são fortemente condicionadas pelo tipo e pela quantidade de adições utilizadas, constatando-se que a adição de CV melhora significativamente algumas das propriedades estudadas principalmente em idades mais avançadas.
Resumo:
FUNDAMENTO: A estenose arterial renal (EAR) é uma causa potencialmente reversível de hipertensão arterial sistêmica (HAS) e nefropatia isquêmica. Apesar da revascularização bem sucedida, nem todos os pacientes (pt) apresentam melhora clínica e alguns podem piorar. OBJETIVO: O presente estudo se destina a avaliar o valor do índice de resistividade renal (IR) como preditor dos efeitos da revascularização renal. MÉTODOS: Entre janeiro de 1998 e fevereiro de 2001, 2.933 pacientes foram submetidos ao duplex ultrassom renal. 106 desses pacientes apresentaram EAR significativa e foram submetidos a angiografia e revascularização renal. A pressão arterial (PA) foi medida antes e depois da intervenção, em intervalos de até 2 anos e as medicações prescritas foram registradas. Antes da revascularização, o IR foi medido em 3 locais do rim, sendo obtida uma média dessas medições. RESULTADOS: Dos 106 pacientes, 81 tiveram IR<80 e 25 RI>80. A EAR foi corrigida somente por angioplastia (PTA) em 25 pts, PTA + stent em 56 pts e cirurgicamente em 25 pts. Dos pacientes que se beneficiaram da revascularização renal; 57 dos 81 pacientes com IR <80 apresentaram melhora em comparação a 5 de 25 com IR > 80. Usando um modelo de regressão logística múltipla, o IR esteve significativamente associado à evolução da PA (p = 0,001), ajustado de acordo com os efeitos da idade, sexo, PAS, PAD, duração da hipertensão, o tipo de revascularização, número de fármacos em uso, nível de creatinina, presença de diabete melito, hipercolesterolemia, volume sistólico, doença arterial periférica e coronariana e tamanho renal (OR 99,6-95%CI para OR 6,1-1.621,2). CONCLUSÃO: A resistividade intrarrenal arterial, medida por duplex ultrassom, desempenha um papel importante na predição dos efeitos pós revascularização renal para EAR.
Resumo:
This paper deals with the most common methods for determining the dc electrical resistivity in solid materials. A brief overview of the fundamental concepts related to the electrical resistivity on materials is introduced. Undoubtedly, the most common and useful procedure to determine the electrical resistivity (rho) is the fourpoint probe method. Some crucial mistakes regarding the experimental procedure and the appropriated correction factors are found in the literature. Thus, the correction factor for the most common sample geometries were gathered and revised in order to provide an easy way to use and apply them.
Resumo:
Estudou-se a influência de adições de 2, 6 e 8% Ag, em peso, na resistividade elétrica da liga Cu-5%Al, utilizando-se o método dos quatro pontos e um sistema de registro contínuo de variação da resistividade elétrica com a temperatura. Os resultados obtidos indicaram que a resistividade elétrica da liga aumenta com o aumento da concentração de prata e que as inflexões observadas nas curvas de variação da resistividade com a temperatura de aquecimento podem ser atribuídas à solubilização da prata na matriz de Cu-Al. Observou-se também que a velocidade de aquecimento da amostra é um fator importante na intensidade e forma dos eventos observados.
Resumo:
Uma vez que a armadura se encontre despassivada, o processo de corrosão vai depender basicamente de dois fatores, que são a resistividade elétrica do concreto e do acesso de oxigênio à armadura. A resistividade elétrica do concreto pode atuar como acelerador ou retardador do processo corrosivo, dado que baixos valores de resistividade significam fácil mobilidade iônica, enquanto que altos valores de resistividade implicam numa baixa mobilidade iônica. De acordo com sua composição e características, o concreto pode ter diferentes valores de resistividade elétrica. Assim, este trabalho objetiva comparar o efeito de diferentes tipos de adição e cimentos na resistividade elétrica aparente de concretos convencionais. São pesquisados concretos com adição de sílica ativa e cinzas de casca de arroz (0, 6 e 12%) cimento CP V -ARI e cimento CP IV 32 e relação água/aglomerante a 0,5, 0,65 e 0,8. Os valores de resistividade elétrica foram obtidos pelo método de Wenner (Método dos 4 eletrodos), em tres situações distintas de exposição do concreto (câmara úmida, câmara climatizada e submerso). Paralelamente foram realizados ensaios de resistência à compressão axial, índice de vazios, grau de saturação dos poros e perda de massa pela evaporação da água. Os resultados obtidos permitiram concluir que, dependendo do tipo de adição ou tipo de cimento, existe um incremento significativo na resistividade elétrica. Foi observado que, de acordo com o ambiente de exposição, o fator mais significativo para a resistividade elétrica foi o tipo de adição ou o tipo de cimento. Também foi possível observar que a influência do ambiente é significativa, evidenciando a importância do grau de saturação dos poros do concreto para a propriedade pesquisada.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Este trabalho descreve os resultados obtidos com o método da eletrorresistividade usando a técnica da sondagem elétrica vertical (arranjo Schlumberger) aplicada em estudos ambientais envolvendo as águas subterrâneas. A vulnerabilidade natural de aqüíferos, importante ferramenta em estudos ambientais, pode ser estimada a partir de métodos geoelétricos, cujos parâmetros resistividade e condutância longitudinal, aliados ao tipo de ocorrência dos aqüíferos (livre a confinado) e profundidade do nível d'água, permitiram obter um índice de vulnerabilidade natural correspondente ao normalmente utilizado. Os resultados, aplicados em uma fase preliminar de estudos, são bons, permitindo um melhor direcionamento e programação das fases posteriores.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)