962 resultados para Pharmaceutical Equivalence


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pharmaceutical equivalence is an important step towards the confirmation of similarity and Interchangeability among pharmaceutical products, particularly regarding those that win not be tested for bioequivalence. The aim of this paper is to compare traditional difference testing to two one-side equivalence tests in the assessment of pharmaceutical equivalence, by means of equivalence studies between similar, generic and reference products of acyclovir cream, atropine sulfate injection, meropenem for injection, and metronidazole injection. All tests were performed in accordance with the Brazilian Pharmacopeia or the United States Pharmacopeia. All four possible combinations of results arise in these comparisons of difference testing and equivalence testing. Most of the former did not show significant difference, whereas the latter presented similarity. We concluded that equivalence testing is more appropriate than difference testing, what can make it a useful tool to assess pharmaceutical equivalence in products that will not be tested for bioequivalence.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Brazilian generic drugs policy was implemented in 1999 with the aim of stimulating competition in the market, improve the quality of drugs and improve the access of the population to drug treatment. The process of implementing this policy allowed the introduction and discussion of concepts that had never before been used in the context of drug registration in Brazil: bioavailability, bioequivalence, pharmaceutical equivalence, generic drugs, biopharmaceutical classification system, biowaiver. The present article provides definitions for these concepts in the context of Brazilian legislation as well as a historical and chronological description of the implementation of the generic drugs policy in Brazil, including a list of current generic drug legislation. This article contributes to the understanding of the Brazilian generic drugs policy and facilitates the search for information concerning the legal requirements for registration of drugs in Brazil.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the present study dissolution tests and thermoanalytical (TA) techniques were applied to metronidazole tablets from five laboratories (R, G, SA, SB, SC) available on the Brazilian market. The TA profiles indicated that in some formulations interactions between components led to eutectic products with lower melting points than metronidazole. The formulations SB and SC showed dissolution profiles that did not agree with published standards, confirming the TA results. All dissolution data were mathematically compared with kinetic models of release, demonstrating the main release mechanism was first order in all the tablets. The formulations were statistically compared by ANOVA and post-hoc tests (Tukey and Newman-Keuls), reveling significant differences in dissolution efficiency (DE).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In spite of the stated Brazilian policy on medicines that their quality, effectiveness and safety should be ensured at reasonable cost, hospitals in the ANVISA Surveillance Network have been receiving notifications of technical complaints, adverse reactions and suspected therapeutic ineffectiveness (STI) of medicines. The purpose of this study was to identify the medicines notified for suspicion of therapeutic ineffectiveness, at a university hospital participating in the national Surveillance Network, and to investigate the existence of polymorphs of any of the drugs involved, by examining the literature. There were 31 notifications of STI in a period of 18 months, concerning 11 different drugs, all of which were 'similar' drugs (neither original nor licensed by originator); five of these could contain polymorphs, according to the literature. However, this does not mean that the other drugs could not contain some unknown polymorphs, more studies being needed on polymorphism, especially in the cases of reported therapeutic ineffectiveness. Therefore, tests of polymorphism should be made part of the routine quality control of the raw materials during the development of medicines and in the studies of pharmaceutical equivalence to 'reference' medicines (innovative brands). The stability test should also involve a study of polymorphism, in order to confirm the solid state stability of the drug. All these measures will assure the effectiveness of medicines, since the reproducibility in the quality of pharmaceutical products could be monitored, as well as the equivalence of each production batch with the batch selected to determine the bioequivalence with the reference brand.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Gastrotoxicity is a major problem for long-term therapy with non-steroidal anti-inflammatory drugs (NSAIDs). DICCIC (1-(2,6-dichlorophenyl)indolin-2-one) is a new diclofenac prodrug, which has proven anti-inflammatory activity without gastroulcerogenic effect. The aim of this work was to compare the pharmacokinetic profiles of diclofenac from DICCIC (7.6 mg/kg equivalent to 8.1 mg/kg diclofenac) and diclofenac (8.1 mg/kg) administration in Wistar rats weighing 250-300 g (n=20). The doses were calculated by interspecific allometric scaling based on the 2 mg/kg from diary human dose of diclofenac. Blood samples were collected in heparinized tubes via the femoral artery through the implanted catheter. The plasma was separated and quantitation was made in a HPLC system with a UV-Vis detector. The confidence limits of the bioanalytical method were appropriate for its application in a preclinical pharmacokinetic study. The AUC of diclofenac from DICCIC (53.7± 5.8 ug/mL.min) was significantly less (Mann Whitney test, p<0.05) than that of diclofenac from diclofenac administration (885.9 ± 124,8 ug/mL.min). Terminal half-life of diclofenac from DICCIC (50.1 ± 17.2 min) was significantly less (Mann Whitney test, p<0.05) than that of diclofenac from diclofenac administration (247.4 ± 100.9 min). Still the parameters clearance and distribution volume were calculated for diclofenac from diclofenac, whose results were 9.2 ±1.2 mL/min.kg and 3.3 ±1.2 L/kg, respectively. The results of DICCIC from DICCIC administration were 108.9 ± 19.6 mL/min.kg and 7.8 ± 2.4 L/kg for clearance and distribution volume, respectively. The pharmacokinetic profile demonstrated that there was an increase in diclofenac elimination and a lower exposure to diclofenac with administration of DICCIC compared to diclofenac. © 2013 Bentham Science Publishers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Furosemide (40mg) was administered to 20 street dogs, 10 males and 10 females, in two different pharmaceutical forms: (1) compressed furosemide 40mg formulated at the Federal University of Pernambuco (UFPE-tablet), and (2) a commercial formulation with equal bioequivalence produced by the Laboratory for Pharmaceutical Technology of Pernambuco State (LAFEPE), the LAFEPE-furosemide. The study aimed to evaluate the kinetics of dissolution of the UFPE-tablet in order to analyze the behavior of bioavailability of the best formulation for veterinary use. The plasmatic concentrations of furosemide for the determination of parameters of pharmacological kinetics were analyzed by high-performance liquid chromatographic method (HPLC). The in vitro study accomplished through physiochemical analyses demonstrated that the formulas of the furosemide tablets attained the pharmaceutical requirements in agreement with USP 23 and the Brazilian Pharmacopoeia. The evaluation accomplished in dogs with UFPE-tablets given in only dose demonstrated uniformity in blood levels indicating stability in maintenance of the pharmaceutical formulation and efficiency in absorption of the active compound. These values are not significantly different in relation to the 5% confidence limit. Regarding maximum concentration (Tmax) time and global bioavaibility assessed by AUC means, there were no considerable differences as well. UFPE-furosemide displayed 743.492µg/mL.h as AUC average value whereas LAFEPE-furosemide had an average of 537.284µg/mL.h.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compared in vitro dissolution characteristics and other quality measures of different amoxicillin, metronidazole, and zidovudine products purchased in the Americas to a comparator pharmaceutical product (CPP). These three drugs are classified as Biopharmaceutics Classification System Class I drugs with the possibility that dissolution findings might be used to document bioequivalence. All investigated zidovudine products were found to be in vitro equivalent to the CPP. Only 3 of 12 tested amoxicillin products were found to be in vitro equivalent to the CPP. None of the tested metronidazole products were in vitro equivalent to the CPP. These findings suggest but do not confirm bioinequivalence where in vitro comparisons failed, given that an in vivo blood level study might have confirmed bioequivalence. At times, identifying a CPP in one of the selected markets proved difficult. The study demonstrates that products sold across national markets may not be bioequivalent. When coupled with the challenge of identifying a CPP in different countries, the results of this study suggest the value of an international CPP as well as increased use of BCS approaches as means of either documenting bioequivalence or signaling the need for further in vivo studies. Because of increased movement of medicines across national borders, practitioners and patients would benefit from these approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper describes a novel, simple and reliable differential pulse voltammetric method for determining amitriptyline (AMT) in pharmaceutical formulations. It has been described for many authors that this antidepressant is electrochemically inactive at carbon electrodes. However, the procedure proposed herein consisted in electrochemically oxidizing AMT at an unmodified carbon nanotube paste electrode in the presence of 0.1 mol L(-1) sulfuric acid used as electrolyte. At such concentration, the acid facilitated the AMT electroxidation through one-electron transfer at 1.33 V vs. Ag/AgCl, as observed by the augmentation of peak current. Concerning optimized conditions (modulation time 5 ms, scan rate 90 mV s(-1), and pulse amplitude 120 mV) a linear calibration curve was constructed in the range of 0.0-30.0 μmol L(-1), with a correlation coefficient of 0.9991 and a limit of detection of 1.61 μmol L(-1). The procedure was successfully validated for intra- and inter-day precision and accuracy. Moreover, its feasibility was assessed through analysis of commercial pharmaceutical formulations and it has been compared to the UV-vis spectrophotometric method used as standard analytical technique recommended by the Brazilian Pharmacopoeia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An HPLC-PAD method using a gold working electrode and a triple-potential waveform was developed for the simultaneous determination of streptomycin and dihydrostreptomycin in veterinary drugs. Glucose was used as the internal standard, and the triple-potential waveform was optimized using a factorial and a central composite design. The optimum potentials were as follows: amperometric detection, E1=-0.15V; cleaning potential, E2=+0.85V; and reactivation of the electrode surface, E3=-0.65V. For the separation of the aminoglycosides and the internal standard of glucose, a CarboPac™ PA1 anion exchange column was used together with a mobile phase consisting of a 0.070 mol L(-1) sodium hydroxide solution in the isocratic elution mode with a flow rate of 0.8 mL min(-1). The method was validated and applied to the determination of streptomycin and dihydrostreptomycin in veterinary formulations (injection, suspension and ointment) without any previous sample pretreatment, except for the ointments, for which a liquid-liquid extraction was required before HPLC-PAD analysis. The method showed adequate selectivity, with an accuracy of 98-107% and a precision of less than 3.9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work encompasses a direct and coherent strategy to synthesise a molecularly imprinted polymer (MIP) capable of extracting fluconazole from its sample. The MIP was successfully prepared from methacrylic acid (functional monomer), ethyleneglycoldimethacrylate (crosslinker) and acetonitrile (porogenic solvent) in the presence of fluconazole as the template molecule through a non-covalent approach. The non-imprinted polymer (NIP) was prepared following the same synthetic scheme, but in the absence of the template. The data obtained from scanning electronic microscopy, infrared spectroscopy, thermogravimetric and nitrogen Brunauer-Emmett-Teller plot helped to elucidate the structural as well as the morphological characteristics of the MIP and NIP. The application of MIP as a sorbent was demonstrated by packing it in solid phase extraction cartridges to extract fluconazole from commercial capsule samples through an offline analytical procedure. The quantification of fluconazole was accomplished through UPLC-MS, which resulted in LOD≤1.63×10(-10) mM. Furthermore, a high percentage recovery of 91±10% (n=9) was obtained. The ability of the MIP for selective recognition of fluconazole was evaluated by comparison with the structural analogues, miconazole, tioconazole and secnidazole, resulting in percentage recoveries of 51, 35 and 32%, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection method for the quantitative analysis of ketoconazole in tablets, based on the reaction with iron (III) ions, is presented. Ketoconazole forms a red complex with iron ions in an acid medium, with maximum absorbance at 495 nm. The detection limit was estimated to be 1×10--4 mol L-1; the quantitation limit is about 3×10--4 mol L-1 and approximately 30 determinations can be performed in an hour. The results were compared with those obtained with a reference HPLC method. Statistical comparisons were done using the Student's t procedure and the F test. Complete agreement was found at the 0.95 significance level between the proposed flow injection and the HPLC procedures. The two methods present similar precision, i.e., for HPLC the mean relative standard deviation was ca. 1.2% and for FIA ca. 1.6%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear concentration range from 9.78 × 10-7 to 7.25 × 10-5 mol L-1 resulting in a limit of detection of 2.12 ± 0.05 x 10-8 mol L-1. Statistical tests showed that the concentrations of 5-ASA in commercial tablets and enemas obtained with the proposed voltammetric method agreed with HPLC values at a 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The possibility of using a graphite silicone-rubber composite electrode (GSR) in a differential pulse voltammetric(DPV) procedure for rutin (vitamin P) determination is described. Cyclic voltammograms of rutin presented a reversible pair of oxidation/reduction peaks respectively at 0.411 and 0.390 V (vs. SCE) at the GSR surface in Britton-Robinson(B-R) buffer solution pH 4.0. In DPV after optimization of conditions, an oxidation peak at 0.370 V (vs. SCE) was used to quantitative determination of rutin in B-R buffer solution pH 4.0. In this case a linear dynamic range of 5.0×10-8 to 50.0×10-8 mol L-1 was observed with a detection limit of 1.8×10-8 mol L-1 for the analyte. Recoveries from 94 to 113% were observed. The electrode surface was renewed by polishing after each determination, with a repeatability of 1.09 ± 0.06 µA (n = 10) peak current. Rutin was determined in a pharmaceutical formulation using the proposed electrode and the results agreed with those from an official method within 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A potentiometric titration method for the determination of minoxidil based on its redox reaction with K2Cr2O7 is described. The best results were observed using 1.00 x 10-3 mol L-1 K2Cr2O7 and 1.00 x 10-2 mol L-1 minoxidil solutions, and the minoxidil as titrant in 2.00 mol L-1 H2SO4 medium. The method was applied to commercial samples and compared with the results from a chromatographic procedure. Recoveries from 97.4 to 98.7 % were observed depending on the sample. Comparison with the chromatographic procedure reveled agreement within 90% confidence level.