887 resultados para Percutaneous technique
Resumo:
Experimental models of tricuspid regurgitation (TR) are needed to study the percutaneous placement of prosthetic atrioventricular valves. The purpose of this study was to develop an appropriate simple and reproducible percutaneous experimental model for creation of tricuspid regurgitation. Tricuspid regurgitation was successfully created through papillary muscle avulsion using a guide-wire loop in seven sheep with regurgitation documented on right ventricular angiograms and a significant increase in heart rate and right atrial pressures. Acute onset of tricuspid regurgitation was poorly tolerated in one animal that died. Autopsy examinations showed avulsion of one papillary muscle in four animals and two papillary muscles in three animals.
Resumo:
A good catheter implantation technique is important to allow effective peritoneal access function and long-term technique survival. Studies regarding results obtained by nephrologists in comparison with different techniques have been limited. The aim of this study was to investigate the rate of early catheter-related complications and catheter survival in two Brazilian centers, according to two different percutaneous methods of catheter implantation performed by nephrologist team. Adult incident patients recruited from January 2006 to July 2013 having undergone first peritoneal dialysis (PD) catheter implantation were included in the analysis. Mechanical and infectious early complication rates were defined as time to the first event occurring up to 3 months. Four hundred and forty-five consecutive Tenckhoff catheters were implanted by nephrologist team percutaneously after antibiotic prophylaxis in an operating room: trocar was used in 349 (78.4 %) and Seldinger technique (ST) in 99 (21.6 %). The ST was significantly associated with a lower rate of leak (16.3 vs 3 %, p = 0.03) and outflow failure due to tip catheter migration (22.6 vs 10.1 %, p = 0.04), while early infectious complication rates were similar between the two groups (p = 0.59). Long-term catheter survival was higher in Seldinger group (log-rank, p = 0.031). By Cox multivariate analysis, adjusted for age, sex, and diabetes, the ST remained independently associated with better catheter survival [HR 0.681 (0.462-0.910), p = 0.04]. As conclusion, our experience showed better PD outcomes with the ST than trocar method of catheter implantation by nephrologist.
Resumo:
The treatment of abdominal aortic aneurysm (AAA) has shifted from the exposure of the aorta artery in an open repair technique to a small groin cut in an endovascular repair. Recently, a percutaneous access for endovascular repair has appeared. This new technique aims to minimize the complications of the common femoral artery exposure, the patient discomfort and the length of hospitalizationObjectives: To compare the proportion of discharged patients within the first 48 postoperative hours of two common femoral artery accesses for endovascular repair of AAA: the open exposure technique and the percutaneous technique. Secondary objectives include to evaluate the total procedure time, the femoral access complications, the need for extra analgesia and the patient satisfaction and groin discomfort of the two techniquesDesign: Randomized controlled trial conducted between 2014 and 2017Participants: Patients diagnosed with abdominal aortic aneurysm with elective endovascular repair indication
Resumo:
Several studies have described 'open' approach techniques for cementation of sheep and goat vertebrae; however, no percutaneous technique has been developed so far for use in non-primates. The aim of this study was to develop an animal model for percutaneous vertebroplasty under clinical conditions.
Resumo:
The majority of transcatheter aortic valve implantations, structural heart procedures and the newly developed transcatheter mitral valve repair and replacement are traditionally performed either through a transfemoral or a transapical access site, depending on the presence of severe peripheral vascular disease or anatomic limitations. The transapical approach, which carries specific advantages related to its antegrade nature and the short distance between the introduction site and the cardiac target, is traditionally performed through a left anterolateral mini-thoracotomy and requires rib retractors, soft tissue retractors and reinforced apical sutures to secure, at first, the left ventricular apex for the introduction of the stent-valve delivery systems and then to seal the access site at the end of the procedure. However, despite the advent of low-profile apical sheaths and newly designed delivery systems, the apical approach represents a challenge for the surgeon, as it has the risk of apical tear, life-threatening apical bleeding, myocardial damage, coronary damage and infections. Last but not least, the use of large-calibre stent-valve delivery systems and devices through standard mini-thoracotomies compromises any attempt to perform transapical transcatheter structural heart procedures entirely percutaneously, as happens with the transfemoral access site, or via a thoracoscopic or a miniaturised video-assisted percutaneous technique. During the past few years, prototypes of apical access and closure devices for transapical heart valve procedures have been developed and tested to make this standardised successful procedure easier. Some of them represent an important step towards the development of truly percutaneous transcatheter transapical heart valve procedures in the clinical setting.
Resumo:
As miopatias em equinos são classificadas de acordo com aspectos clínicos, morfológicos e moleculares, em três grandes grupos: não associadas ao exercício, associadas ao exercício e devido alteração da condução elétrica do sarcolema. Apesar dos avanços no diagnóstico, a literatura ainda relata surtos de miopatia em equinos sem etiologia esclarecida em diversos países. O objetivo desse estudo foi descrever as alterações histológicas e histoquímicas de biópsias musculares de equinos acometidos por miopatia. Sete equinos da raça Quarto de Milha, com 18-24 meses de idade, apresentaram sinais clínicos de miopatia. Dentre esses animais, cinco apresentaram sinais subagudos leves a moderados e dois apresentaram sinais hiperagudos severos e decúbito lateral. Foram realizadas biópsias musculares utilizando a técnica percutânea, por agulha tipo Bergström, no músculo glúteo médio em todos os animais acometidos. As amostras foram processadas por meio de técnicas histológicas (HE, Tricrômio de Gomori modificado) e histoquímicas (PAS, NADH, ATPase). Nos quadros clínicos mais leves, a principal alteração encontrada foi a presença de fibras vermelhas rajadas do tipo I e IIA, que estão associadas às alterações do metabolismo oxidativo e das funções mitocondriais, como ocorrem nas miopatias mitocondriais. Também foram observadas fibras atróficas do tipo I e IIA, além da presença de agregados subsarcolemais. Nos quadros mais severos o tecido muscular apresentou infiltrado inflamatório, aumento de colágeno, fagocitose, necrose, calcificação e regeneração muscular. Diante dos achados morfológicos, da resposta à terapia com vitamina E e Se e da baixa mortalidade quando comparado aos relatos de miopatia atípica, conclui-se que esse surto foi desencadeado por lesões mitocondriais, caracterizadas pelas fibras musculares vermelhas rajadas, possivelmente devido uma quebra da homeostase de vitamina E e Se, sendo compatível com o diagnóstico de miopatia nutricional.
Resumo:
Background and study aims In many patients, percutaneous endoscopic gastrostomy (PEG) can be limited by digestive tract stenosis. PEG placement using an introducer is the safest alternative for this group of patients, but the available devices are difficult to implement and require smaller-caliber tubes. The aim of this study was to evaluate the modification of an introducer technique device for PEG placement with regard to the following: procedure feasibility, possibility of using a 20-Fr balloon gastrostomy tube, tube-related function and problems, complications, procedure safety, and mortality. Patients and methods Between March 2007 and February 2008, 30 consecutive patients with head and neck malignancies underwent introducer PEG placement with the modified device and gastropexy. Each patient was evaluated for 60 days after the procedure for the success of the procedure, infection, pain, complications, mortality, and problems with the procedure. Results The procedure was successful in all cases with no perioperative complications. No signs of stomal infection were observed using the combined infection score. The majority of patients experienced mild-to-moderate pain both in the immediate postoperative period and at 72 hours. One major early complication (3.3%) and two minor complications (6.7%) were observed. No procedure-related deaths occurred during the first 60 days after the procedure. Conclusion The device modification for PEG using the introducer technique is feasible, safe, and efficient in outpatients with obstructive head and neck cancer. In this series, it allowed the use of a larger-caliber tube with low complication rates and no procedure-related mortality.
Resumo:
Retained T-tubes are rare complications after biliary surgery. The authors present three cases of retained T-tubes in patients with transplanted liver that could not be removed by a standard manual traction. The authors describe a new simple percutaneous method that allows removal of these T-tubes without complication.
Resumo:
Angioplasty and stenting of the IA have been reported with high technical and clinical success rates, low complication rates and good mid-term patency rates. Different antegrade or retrograde endovascular catheter-based approaches and combinations with surgical exposure of the CCA are used. The purpose of this study was to determine safety, efficacy and mid-term clinical and radiological outcome of the stent-assisted treatment of atherosclerotic stenotic disease of the IA with special focus on the different technical approaches.
Resumo:
Background/Purpose: Central venous catheterization is among the most common procedures performed by pediatric surgeons. Significant morbidity and even mortality can ensue from the widespread approach to the deep veins of the neck and femoral region. The external jugular vein (EJV) is a low-morbidity alternative for percutaneous catheterization in children, but it has yielded a low success rate in previous reports The authors show an improved success rate with this option. Methods: We performed an analysis of 33 patients` charts in which central venous catheterization using Seldinger technique through the EJV was attempted in 2005. Age, diagnosis, maneuvers used for success, fluoroscopy usefulness, and types of inserted catheters were evaluated. Results: The procedure was successful in 26 (78.8%) patients without complications. Diagnosis was neoplasia in almost half of the patients (42%). In half of the successful cases, body maneuvers were used, namely, twisting the head of the patient to the side of the vein and stretching the ipsilateral arm and shoulder. All but one procedure were completed under fluoroscopic guidance. In 6 (23%) patients, a long-term catheter was inserted. Conclusions: The EJV is an excellent option for central venous catheterization in children. The execution of simple maneuvers along with fluoroscopic assistance might allow for an improved success rate not only for short-term but also for long-term catheter insertion. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
The flux of a compound across a membrane from any formulation, whether it contains penetration enhancers or not, is limited by its saturated solubility in the vehicle. Under such conditions the concentration of the permeant in the outer layers of the stratum corneum is also saturated. Consequently, when the permeation of a drug from a supersaturated solution leads to enhanced penetration, the concentration of the drug in the outer layers of the membrane is also supersaturated. Therefore, the stratum corneum may possess antinucleant properties which inhibit or retard the crystallisation process. In this study, the enhanced in vitro permeation of supersaturated solutions of piroxicam across human skin in diffusion cells was demonstrated. The amount of permeant in the stratum corneum was determined using a tape stripping technique. Supersaturated solutions up to four degrees of saturation were investigated which produced a linear relationship between the degree of saturation and the amount of piroxicam in the stratum corneum (R-2 = 0.970). Furthermore, the amount of piroxicam in the viable layers of the skin also increased with increasing degree of saturation. An analysis of the results suggested that enhanced penetration across human skin from supersaturated solutions of piroxicam may occur as a result of the antinucleating ability of the intercellular lipids of the stratum corneum. (C) 1997 Elsevier Science B.V.
Resumo:
PURPOSE: To evaluate retrospectively the midterm and long-term results of percutaneous endovascular treatment of venous outflow obstruction after pediatric liver transplantation. MATERIALS AND METHODS: During a 9-year period, 18 children with obstruction of a hepatic vein (HV) or inferior vena cava (IVC) anastomosis underwent percutaneous transluminal angioplasty (PTA) with balloon dilation or stent placement in case of PTA failure after liver transplantation. Patients` body weights ranged from 7.7 kg to 42.6 kg (mean, 18.8 kg +/- 9). Potential predictors of patency were compared between balloon dilation and stent placement groups. RESULTS: Forty-two procedures were performed (range, 1-11 per patient; mean, 2). Technical and initial clinical success were achieved in all cases. Major complications included one case of pulmonary artery stent embolization and one case of hemothorax. Three children (25%) with HV obstruction were treated with PTA and nine (75%) were treated with stent placement. Three children with IVC obstruction (75%) were treated with PTA and one (25%) was treated with a stent. There were two children with simultaneous obstruction at the HV and IVC; one was treated with PTA and the other with a stent. Cases of isolated HV stenosis have a higher probability of patency with balloon-expandable stent treatment compared with balloon dilation (P < .05). Follow-up time ranged from 7 days to 9 years (mean, 42 months +/- 31), and the primary assisted patency rate was 100% when stent placement was performed among the first three procedures. CONCLUSIONS: In cases of venous outflow obstruction resulting from HV and/or IVC lesions after pediatric liver transplantation, percutaneous endovascular treatment with balloon dilation or stent placement is a safe and effective alternative treatment that results in long-term patency.
Resumo:
Annular pancreas is a rare congenital anomaly, which is only surgically treated in symptomatic cases. Surgical treatment consists of bypassing the duodenal transit by gastrojejunal or duodenal-jejunal anastomosis. In the absolute majority of published cases, laparotomy is the most widely used access technique. The aim of this article is to report a case of an annular pancreas and describe the technical steps involved in carrying out a laparoscopic duodenal-jejunal anastomosis, for correction of the duodenal obstruction. The patient`s recovery was uneventful; she was discharged on the fourth postoperative day and remained asymptomatic for the 2-year, outpatient follow-up period. Laparoscopic duodenal-jejunal bypass is shown to be feasible and safe, and produce less surgical trauma, when carried out by an experienced surgeon who is duly trained and familiar with the laparoscopic technique.
Resumo:
The authors present the first clinical implementation of an endoscopic-assisted percutaneous anterolateral radiofrequency cordotomy. The aim of this article is to demonstrate the intradural endoscopic visualization of the cervical spinal cord via a percutaneous approach to refine the spinal target for anterolateral cordotomy, avoiding undesired trauma to the spinal tissue or injury to blood vessels. Initially, a lateral puncture of the spinal canal in the C1-2 interspace is performed, guided by fluoroscopy. As soon as CSF is reached by the guide cannula (17-gauge needle), the endoscope can be inserted for visualization of the spinal cord and its surrounding structures. The endoscopic visualization provided clear identification of the pial surface of the spinal cord, arachnoid membrane, dentate ligament, dorsal and ventral root entry zone, and blood vessels. The target for electrode insertion into the spinal cord was determined to be the midpoint from the dentate ligament and the ventral root entry zone. The endoscopic guidance shortened the fluoroscopy usage time and no intrathecal contrast administration was needed. Cordotomy was performed by a standard radiofrequency method after refining of the neurophysiological target. Satisfactory analgesia was provided by the procedure with no additional complications or CSF leak. The initial use of this technique suggests that a percutaneous endoscopic procedure may be useful for particular manipulation of the spinal cord, possibly adding a degree of safety to the procedure and improving its effectiveness. (DOI: 10.3171/2010.4.JNS091779)