999 resultados para Penning trap


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The LPT (Lanzhou Penning Trap) is under construction and its task is to perforin direct mass measurement of fusion-evaporation residue, and if possible for heavy isotopes. Detailed simulations have been clone for a good understanding to the ion's movement and mechanics in the trap. The optimizal ion of the LPT is also performed based on the simulation. With a scale of 0.5 mm per grid used in the, simulation and many other limitations a highest mass resolution has been achieved to be 1.9 x 10(-5). An unexpected behavioin in the simulation related to magnetron motion has been found.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Penning trap mass spectrometer SHIPTRAP at GSI Darmstadt allows accurate mass measurements of radionuclides, produced in fusion-evaporation reactions and separated by the velocity filter SHIP from the primary beam. Recently, the masses of the three nobelium isotopes No252-254 were determined. These are the first direct mass measurements of transuranium elements, which provide new anchor points in this region. The heavy nuclides were produced in cold-fusion reactions by irradiating a PbS target with a Ca-48 beam, resulting in production rates of the nuclei of interest of about one atom per second. In combination with data from decay spectroscopy our results are used to perform a new atomic-mass evaluation in this region.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Penning trap system called Lanzhou Penning Trap (LPT) is now being developed for precise mass measurements at the Institute of Modern Physics (IMP). One of the key components is a 7 T actively shielded superconducting magnet with a clear warm bore of 156 mm. The required field homogeneity is 3 x 10(-7) over two 1 cubic centimeter volumes lying 220 mm apart along the magnet axis. We introduce a two-step method which combines linear programming and a nonlinear optimization algorithm for designing the multi-section superconducting magnet. This method is fast and flexible for handling arbitrary shaped homogeneous volumes and coils. With the help of this method an optimal design for the LPT superconducting magnet has been obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A penning trap system called LPT (LANZHOU PENNING TRAP) is now being developed for precise mass measurements in IMP (Institute of Modern Physics). The most key component of LPT is a superconducting magnet. A Phi 156 mm warm bore and two cylinder good field regions with a distance of 220 mm are required for trapping ions and measurements. As the required homogeneity is better than 0.5 ppm, several complicated coaxial coils are used to produce such a magnetic field. The size and position of these coils are optimized by using a method combining linear program with multiobjective optimization. Superconducting shim coils and passive shim pieces are used to eliminate inevitable winding tolerances and environmental influence. The fringe field is decreased to 5 Gs at 2 m line from the center of the magnet by active shielding coils. The designs of the mechanical structure, the quench protection system are also introduced in this paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this thesis I present theoretical and experimental results concern- ing the operation and properties of a new kind of Penning trap, the planar trap. It consists of circular electrodes printed on an isolating surface, with an homogeneous magnetic field pointing perpendicular to that surface. The motivation of such geometry is to be found in the construction of an array of planar traps for quantum informa- tional purposes. The open access to radiation of this geometry, and the long coherence times expected for Penning traps, make the planar trap a good candidate for quantum computation. Several proposals for quantum 2-qubit interactions are studied and estimates for their rates are given. An expression for the electrostatic potential is presented, and its fea- tures exposed. A detailed study of the anharmonicity of the potential is given theoretically and is later demonstrated by experiment and numerical simulations, showing good agreement. Size scalability of this trap has been studied by replacing the original planar trap by a trap twice smaller in the experimental setup. This substitution shows no scale effect apart from those expected for the scaling of the parameters of the trap. A smaller lifetime for trapped electrons is seen for this smaller trap, but is clearly matched to a bigger misalignment of the trap’s surface and the magnetic field, due to its more difficult hand manipulation. I also give a hint that this trap may be of help in studying non-linear dynamics for a sextupolarly perturbed Penning trap.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In der vorgelegten Doktorarbeit werden Experimente vorgestellt, die an einem einzelnen Proton in einer Penningfalle durchgeführt worden sind. Die Eigenbewegung eines isoliert gespeicherten, freien Protons konnte elektronisch durch Kopplung an einen Resonanzschwingkreis nachgewiesen werden. Dies stellt eine nicht-destruktive Messung dar, d. h. das Teilchen geht während der Messung nicht verloren. Die freie Zyklotronfrequenz, die aus den drei gemessenen Eigenfrequenzen hervorgeht, ist eine von zwei zur Bestimmung des magnetischen Moments notwendigen Frequenzen. So wird im Gegensatz zu den existierenden Arbeiten eine direkte Bestimmung des g-Faktors ermöglicht. Planung, Entwicklung und Inbetriebnahme des experimentellen Aufbaus wurden im Rahmen dieser Arbeit durchgeführt, womit eine Messgenauigkeit von 10-7 erreicht wurde. Die dabei zu bewältigenden technischen Herausforderungen zur Bestimmung der zweiten Frequenz (der Larmorfrequenz) ergeben sich aus der Kleinheit des magnetischen Moments. Bei dem für diese Messung benötigten Spinzustand des Teilchens handelt es sich um einen internen Freiheitsgrad, der nur über eine Kopplung des magnetischen Moments an die Eigenbewegung bestimmt werden kann. Eine neuartige, hybride Penningfalle wird in dieser Arbeit vorgestellt, die als Quantensprung-Spektrometer die Spininformation auf die Eigenbewegung abbildet. Damit liegt der aus der magnetischen Kopplung resultierende Frequenzunterschied in den beiden Spinzuständen erstmalig in einem elektronisch detektierbaren Bereich.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Das Penningfallen-Massenspektrometer SHIPTRAP wurde gebaut um HochprÄazi-rnsionsmassenmessungen an schweren Radionukliden durchzufÄuhren, die in Fusions-rnreaktionen produziert und vom Geschwindigkeitsfilter SHIP vom Primärstrahl sepa-rnriert werden. Es besteht aus einer Gaszelle zur Abbremsung der hochenergetis-rnchen Reaktionsprodukte, einem RFQ-Kühler und Buncher zur Kühlung und Akku-rnmulation der Ionen und einem Doppel-Penningfallen-System um Massenmessungenrndurchzuführen. Die Masse wird durch die Messungen der Zyklotronfrequenz desrnentsprechenden Ions in einem starken homogenen Magnetfeld bestimmt. Diese Fre-rnquenz wird mit der Frequenz eines wohlbekannten Referenzions verglichen. Mitrndieser Methode können relative Fehler in der Größenordnung von 10^-8 erreicht werden. Kürzlich konnten die Massen der Nobeliumisotope 252-254No (Z=102) und desrnLawrenciumisotops 255Lr (Z=103) erstmals erfolgreich gemessen werden. Dies warenrndie ersten direkten Massenmessungen an Transuranen. Die Produktionrate dieserrnAtome lag bei etwa eins pro Sekunde und weniger. Die Ergebnisse der Massenmes-rnsungen an Nobelium bestätigen die früheren Massenwerte, die aus Q_alpha-Messungenrnabgeleitet wurden. Im Fall von 255Lr wurde der Massenexzess, der bis dahin nur ausrnsystematischen Trends abgeschätzt wurde, zum ersten Mal direkt bestimmt. DiesernErgebnisse sind ein erster Schritt für die an SHIPTRAP geplante Erforschung derrnRegion der Transurane. Das Hauptziel ist hierbei die Bestimmung der Endpunkternder alpha-Zerfallsketten, die in superschweren Elementen in der Nähe der vorhergesagtenrnStabilitätsinsel ihren Ursprung nehmen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Heutzutage gewähren hochpräzise Massenmessungen mit Penning-Fallen tiefe Einblicke in die fundamentalen Eigenschaften der Kernmaterie. Zu diesem Zweck wird die freie Zyklotronfrequenz eines Ions bestimmt, das in einem starken, homogenen Magnetfeld gespeichert ist. Am ISOLTRAP-Massenspektrometer an ISOLDE / CERN können die Massen von kurzlebigen, radioaktiven Nukliden mit Halbwertszeiten bis zu einigen zehn ms mit einer Unsicherheit in der Größenordnung von 10^-8 bestimmt werden. ISOLTRAP besteht aus einem Radiofrequenz-Quadrupol zum akkumulieren der von ISOLDE gelieferten Ionen, sowie zwei Penning-Fallen zum säubern und zur Massenbestimmung der Ionen. Innerhalb dieser Arbeit wurden die Massen von neutronenreichen Xenon- und Radonisotopen (138-146Xe und 223-229Rn) gemessen. Für elf davon wurde zum ersten Mal die Masse direkt bestimmt; 229Rn wurde im Zuge dieses Experimentes sogar erstmalig beobachtet und seine Halbwertszeit konnte zu ungefähr 12 s bestimmt werden. Da die Masse eines Nuklids alle Wechselwirkungen innerhalb des Kerns widerspiegelt, ist sie einzigartig für jedes Nuklid. Eine dieser Wechselwirkungen, die Wechselwirkung zwischen Protonen und Neutronen, führt zum Beispiel zu Deformationen. Das Ziel dieser Arbeit ist eine Verbindung zwischen kollektiven Effekten, wie Deformationen und Doppeldifferenzen von Bindungsenergien, sogenannten deltaVpn-Werten zu finden. Insbesondere in den hier untersuchten Regionen zeigen deltaVpn-Werte ein sehr ungewöhnliches Verhalten, das sich nicht mit einfachen Argumenten deuten lässt. Eine Erklärung könnte das Auftreten von Oktupoldeformationen in diesen Gebieten sein. Nichtsdestotrotz ist eine quantitative Beschreibung von deltaVpn-Werten, die den Effekt von solchen Deformationen berücksichtigt mit modernen Theorien noch nicht möglich.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nuclear masses are an important quantity to study nuclear structure since they reflect the sum of all nucleonic interactions. Many experimental possibilities exist to precisely measure masses, out of which the Penning trap is the tool to reach the highest precision. Moreover, absolute mass measurements can be performed using carbon, the atomic-mass standard, as a reference. The new double-Penning trap mass spectrometer TRIGA-TRAP has been installed and commissioned within this thesis work, which is the very first experimental setup of this kind located at a nuclear reactor. New technical developments have been carried out such as a reliable non-resonant laser ablation ion source for the production of carbon cluster ions and are still continued, like a non-destructive ion detection technique for single-ion measurements. Neutron-rich fission products will be available by the reactor that are important for nuclear astrophysics, especially the r-process. Prior to the on-line coupling to the reactor, TRIGA-TRAP already performed off-line mass measurements on stable and long-lived isotopes and will continue this program. The main focus within this thesis was on certain rare-earth nuclides in the well-established region of deformation around N~90. Another field of interest are mass measurements on actinoids to test mass models and to provide direct links to the mass standard. Within this thesis, the mass of 241-Am could be measured directly for the first time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ion traps have been established as a powerful tool for ion cooling and laser spectroscopy experiments since a long time ago. SpecTrap, one of the precision experiments associated to the HITRAP facility at GSI, is implementing a Penning trap for studies of large bunches of externally produced highly charged ions. The extremely strong electric and magnetic fields that exist around the nuclei of heavy elements drastically change their electronic properties, such as energy level spacings and radiative lifetimes. The electrons can therefore serve as sensitive probes for nuclear properties such as size, magnetic moment and spatial distribution of charge and magnetization. The energies of forbidden fine and hyperfine structure transitions in such ions strongly depend on the nuclear charge and shift from the microwave domain into the optical domain. Thus, they become accessible for laser spectroscopy and its potentially high accuracy. A number of such measurements has been performed in storage rings and electron beam ion traps and yielded results with relative accuracies in the 10

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Das in dieser Arbeit vorgestellte Experiment zur Messung des magnetischen Moments des Protons basiert auf der Messung des Verhältnisses von Zyklotronfrequenz und Larmorfrequenz eines einzelnen, in einer kryogenen Doppel-Penning Falle gespeicherten Protons. In dieser Arbeit konnten erstmalig zwei der drei Bewegungsfrequenzen des Protons gleichzeitig im thermischen Gleichgewicht mit entsprechenden hochsensitiven Nachweissystemen nicht-destruktiv detektiert werden, wodurch die Messzeit zur Bestimmung der Zyklotronfrequenz halbiert werden konnte. Ferner wurden im Rahmen dieser Arbeit erstmalig einzelne Spin-Übergänge eines einzelnen Protons detektiert, wodurch die Bestimmung der Larmorfrequenz ermöglicht wird. Mithilfe des kontinuierlichen Stern-Gerlach Effekts wird durch eine sogenannte magnetische Flasche das magnetische Moment an die axiale Bewegungsmode des Protons gekoppelt. Eine Änderung des Spinzustands verursacht folglich einen Frequenzsprung der axialen Bewegungsfrequenz, welche nicht-destruktiv gemessen werden kann. Erschwert wird die Detektion des Spinzustands dadurch, dass die axiale Frequenz nicht nur vom Spinmoment, sondern auch vom Bahnmoment abhängt. Die große experimentelle Herausforderung besteht also in der Verhinderung von Energieschwankungen in den radialen Bewegungsmoden, um die Detektierbarkeit von Spin-Übergängen zu gewährleisten. Durch systematische Studien zur Stabilität der axialen Frequenz sowie einer kompletten Überarbeitung des experimentellen Aufbaus, konnte dieses Ziel erreicht werden. Erstmalig kann der Spinzustand eines einzelnen Protons mit hoher Zuverlässigkeit bestimmt werden. Somit stellt diese Arbeit einen entscheidenden Schritt auf dem Weg zu einer hochpräzisen Messung des magnetischen Moments des Protons dar.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ECHo Collaboration (Electron Capture 163Ho aims to investigate the calorimetric spectrum following the electron capture decay of 163Ho to determine the mass of the electron neutrino. The size of the neutrino mass is reflected in the endpoint region of the spectrum, i.e., the last few eV below the transition energy. To check for systematic uncertainties, an independent determination of this transition energy, the Q-value, is mandatory. Using the TRIGA-TRAP setup, we demonstrate the feasibility of performing this measurement by Penning-trap mass spectrometry. With the currently available, purified 163Ho sample and an improved laser ablation mini-RFQ ion source, we were able to perform direct mass measurements of 163Ho and 163Dy with a sample size of less than 1017 atoms. The measurements were carried out by determining the ratio of the cyclotron frequencies of the two isotopes to those of carbon cluster ions using the time-of-flight ion cyclotron resonance method. The obtained mass excess values are ME(163Ho)= −66379.3(9) keV and ME(163Dy)= −66381.7(8) keV. In addition, the Q-value was measured for the first time by Penning-trap mass spectrometry to be Q = 2.5(7) keV.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The g-factor is a constant which connects the magnetic moment $vec{mu}$ of a charged particle, of charge q and mass m, with its angular momentum $vec{J}$. Thus, the magnetic moment can be writen $ vec{mu}_J=g_Jfrac{q}{2m}vec{J}$. The g-factor for a free particle of spin s=1/2 should take the value g=2. But due to quantum electro-dynamical effects it deviates from this value by a small amount, the so called g-factor anomaly $a_e$, which is of the order of $10^{-3}$ for the free electron. This deviation is even bigger if the electron is exposed to high electric fields. Therefore highly charged ions, where electric field strength gets values on the order of $10^{13}-10^{16}$V/cm at the position of the bound electron, are an interesting field of investigations to test QED-calculations. In previous experiments [H"aff00,Ver04] using a single hydrogen-like ion confined in a Penning trap an accuracy of few parts in $10^{-9}$ was obtained. In the present work a new method for precise measurement of magnetic the electronic g-factor of hydrogen-like ions is discussed. Due to the unavoidable magnetic field inhomogeneity in a Penning trap, a very important contribution to the systematic uncertainty in the previous measurements arose from the elevated energy of the ion required for the measurement of its motional frequencies. Then it was necessary to extrapolate the result to vanishing energies. In the new method the energy in the cyclotron degree of freedom is reduced to the minimum attainable energy. This method consist in measuring the reduced cyclotron frequency $nu_{+}$ indirectly by coupling the axial to the reduced cyclotron motion by irradiation of the radio frequency $nu_{coup}=nu_{+}-nu_{ax}+delta$ where $delta$ is, in principle, an unknown detuning that can be obtained from the knowledge of the coupling process. Then the only unknown parameter is the desired value of $nu_+$. As a test, a measurement with, for simplicity, artificially increased axial energy was performed yielding the result $g_{exp}=2.000~047~020~8(24)(44)$. This is in perfect agreement with both the theoretical result $g_{theo}=2.000~047~020~2(6)$ and the previous experimental result $g_{exp1}=2.000~047~025~4(15)(44).$ In the experimental results the second error-bar is due to the uncertainty in the accepted value for the electron's mass. Thus, with the new method a higher accuracy in the g-factor could lead by comparison to the theoretical value to an improved value of the electron's mass. [H"af00] H. H"affner et al., Phys. Rev. Lett. 85 (2000) 5308 [Ver04] J. Verd'u et al., Phys. Rev. Lett. 92 (2004) 093002-1

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In dieser Arbeit wird der Entwurf, der Aufbau, die Inbetriebnahme und die Charakterisierung einer neuartigen Penning-Falle im Rahmen des Experiments zur Bestimmung des g-Faktors des Protons präsentiert. Diese Falle zeichnet sich dadurch aus, dass die Magnetfeldlinien eines äußeren homogenen Magnetfeldes durch eine ferromagnetische Ringelektrode im Zentrum der Falle verzerrt werden. Der inhomogene Anteil des resultierenden Magnetfeldes, die sogenannte magnetische Flasche, lässt sich durch den Koeffizient B2 = 297(10) mT/mm2 des Terms zweiter Ordnung der Ortsabhängigkeit des Feldes quantifizieren. Eine solche ungewöhnlich starke Feldinhomogenität ist Grundvoraussetzung für den Nachweis der Spinausrichtung des Protons mittels des kontinuierlichen Stern-Gerlach-Effektes. Dieser Effekt basiert auf der im inhomogenen Magnetfeld entstehenden Kopplung des Spin-Freiheitsgrades des gefangenen Protons an eine seiner Eigenfrequenzen. Ein Spin-Übergang lässt sich so über einen Frequenzsprung detektieren. Dabei ist die nachzuweisende Änderung der Frequenz proportional zu B2 und zum im Fall des Protons extrem kleinen Verhältnis zwischen seinem magnetischen Moment nund seiner Masse. Die durch die benötigte hohe Inhomogenität des Magnetfeldes bedingten technischen Herausforderungen erfordern eine fundierte Kenntnis und Kontrolle der Eigenschaften der Penning-Falle sowie der experimentellen Bedingungen. Die in der vorliegenden Arbeit entwickelte Penning-Falle ermöglichte den erstmaligen zerstörungsfreien Nachweis von Spin-Quantensprüngen eines einzelnen gefangenen Protons, was einen Durchbruch für das Experiment zur direkten Bestimmung des g-Faktors mit der angestrebten relativen Genauigkeit von 10−9 darstellte. Mithilfe eines statistischen Verfahrens ließen sich die Larmor- und die Zyklotronfrequenz des Protons im inhomogenen Magnetfeld der Falle ermitteln. Daraus wurde der g-Faktor mit einer relativen Genauigkeit von 8,9 × 10−6 bestimmt. Die hier vorgestellten Messverfahren und der experimentelle Aufbau können auf ein äquivalentes Experiment zur Bestimmung des g-Faktors des Antiprotons zum Erreichen der gleichen Messgenauigkeit übertragen werden, womit der erste Schritt auf dem Weg zu einem neuen zwingenden Test der CPT-Symmetrie im baryonischen Sektor gemacht wäre.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents an introduction to the application of ion traps and storage devices for cluster physics. Some experiments involving cluster ions in trapping devices such as Penning traps, Paul traps, quadrupole or multipole linear traps are briefly discussed. Electrostatic ion storage rings and traps which allow for the storage of fast ion beams without mass limitation are presented as well. We also report on the recently developed mini-ring, a compact electrostatic ion storage ring for cluster, molecular and biomolecular ion studies.