931 resultados para Pelvic tilt
Resumo:
In order to gain a competitive edge in the market, automotive manufacturers and automotive seat suppliers have identified seat ergonomics for further development to improve overall vehicle comfort. Adjustable lumbar support devices have been offered since long as comfort systems in either a 2-way or 4-way adjustable configuration, although their effect on lumbar strain is not well documented. The effect of a lumbar support on posture and muscular strain, and therefore the relationship between discomfort and comfort device parameter settings, requires clarification. The aim of this paper is to study the effect of a 4-way lumbar support on lower trunk and pelvis muscle activity, pelvic tilt and spine curvature during a car seating activity. 10 healthy subjects (5 m/f; age 19-39) performed a seating activity in a passenger vehicle with seven different static lumbar support positions. The lumbar support was tested in 3 different height positions in relation to the seatback surface centreline (high, centre, low), each having 2 depths positions (lumbar prominence). An extra depth position was added for the centre position. Posture data were collected using a VICON MX motion capture system and NORAXON DTS goniometers and inclinometer. A rigid-body model of an adjustable car seat with four-way adjustable lumbar support was constructed in UGS Siemens NX and connected to a musculoskeletal model of a seated-human, modelled in AnyBody. Wireless electromyography (EMG) was used to calibrate the musculoskeletal model and assess the relationship between (a) muscular strain and lumbar prominence (normal to seatback surface) respective to the lumbar height (alongside seatback surface), (b) hip joint moment and lumbar prominence (normal to seatback surface) respective to lumbar height (alongside seatback surface) and (c) pelvic tilt and lumbar prominence (normal to seatback surface) respective to the lumbar height (alongside seatback surface). This study was based on the assumption that the musculoskeletal human model was seated at the correct R-Point (SgRP), determined via the occupant packaging toolkit in the JACK digital human model. The effect of the interaction between the driver/car-seat has been investigated for factors resulting from the presence and adjustment of a 4-way lumbar support. The results obtained show that various seat adjustments, and driver’s lumbar supports can have complex influence on the muscle activation, joint forces and moments, all of which can affect the comfort perception of the driver. This study enables the automotive industry to optimise passenger vehicle seat development and design. It further more supports the evaluation of static postural and dynamic seat comfort in normal everyday driving tasks and can be applied for future car design to reduce investment and improve comfort.
Resumo:
Although the ischial spine sign (ISS) has been advocated to detect acetabular retroversion, it is unknown whether the sign is valid on anteroposterior (AP) pelvic radiographs with tilted or rotated pelves. We therefore evaluated reliability of the ISS as a tool for diagnosing acetabular retroversion in the presence of considerable pelvic tilt and/or malrotation. We obtained radiographs of 20 cadaver pelves in 19 different malorientations resulting in 380 pelvis images (760 hips) for evaluation. In addition, 129 clinical radiographs of patients' hips that had varying pelvis orientations were reviewed. We found an overall sensitivity of 81% (90%), specificity of 70% (71%), positive predictive value of 77% (80.7%), and negative predictive value of 75% (85%) in the cadaver (patient) hips. Our data suggest the ISS is a valid tool for diagnosing acetabular retroversion on plain radiographs taken using a standardized technique regardless of the degree of pelvic tilt and rotation.
Resumo:
OBJECTIVE: To compare six different parameters described in literature for estimation of pelvic tilt on an anteroposterior pelvic radiograph and to create a simple nomogram for tilt correction of prosthetic cup version in total hip arthroplasty. DESIGN: Simultaneous anteroposterior and lateral pelvic radiographs are taken routinely in our institution and were analyzed prospectively. The different parameters (including three distances and three ratios) were measured and compared to the actual pelvic tilt on the lateral radiograph using simple linear regression analysis. PATIENTS: One hundred and four consecutive patients (41 men, 63 women with a mean age of 31.7 years, SD 9.2 years, range 15.7-59.1 years) were studied. RESULTS: The strongest correlation between pelvic tilt and one of the six parameters for both men and women was the distance between the upper border of the symphysis and the sacrococcygeal joint. The correlation coefficient was 0.68 for men (P<0.001) and 0.61 for women (P<0.001). Based on this linear correlation, a nomogram was created that enables fast, tilt-corrected cup version measurements in clinical routine use. CONCLUSION: This simple method for correcting variations in pelvic tilt on plain radiographs can potentially improve the radiologist's ability to diagnose and interpret malformations of the acetabulum (particularly acetabular retroversion and excessive acetabular overcoverage) and post-operative orientation of the prosthetic acetabulum.
Resumo:
BACKGROUND While surgical navigation offers the opportunity to accurately place an acetabular component, questions remain as to the best goal for acetabular component positioning in individual patients. Overall functional orientation of the pelvis after surgery is one of the most important variables for the surgeon to consider when determining the proper goal for acetabular component orientation. QUESTIONS/PURPOSES We measured the variation in pelvic tilt in 30 patients before THA and the effect of THA on pelvic tilt in the same patients more than a year after THA. METHODS Each patient had a CT study for CT-based surgical navigation and standing and supine radiographs before and after surgery. Pelvic tilt was calculated for each of the radiographs using a novel and validated two-dimensional/three-dimensional matching technique. RESULTS Mean supine pelvic tilt changed less than 2°, from 4.4° ± 6.4° (range, -7.7° to 20.8°) before THA to 6.3° ± 6.6° (range, -5.7° to 19.6°) after THA. Mean standing pelvic tilt changed less than 1°, from 1.5° ± 7.2° (range, -13.1° to 12.8°) before THA to 2.0° ± 8.3° (range, -12.3° to 16.8°) after THA. Preoperative pelvic tilt correlated with postoperative tilt in both the supine (r(2) = 0.75) and standing (r(2) = 0.87) positions. CONCLUSIONS In this population, pelvic tilt had a small and predictable change after surgery. However, intersubject variability of pelvic tilt was high, suggesting preoperative pelvic tilt should be considered when determining desired acetabular component positioning on a patient-specific basis.
Resumo:
Background Acetabular anatomy on AP pelvic radiographsdepends on pelvic orientation during radiograph acquisition. However, not all parameters may change to a clinically relevant degree with differences in pelvic orientation. This issue may influence the diagnosis of acetabular pathologies and planning of corrective acetabular surgery (reorientation or rim trimming). However, to this point, it has not been well characterized. Questions/purposes We asked (1) which radiographic parameters change in a clinical setting when normalized to neutral pelvic orientation; (2) which parameters do not change in an experimental setting when the pelvis is experimentally rotated/tilted; and (3) which of these changes are ‘‘ultimately’’ relevant based on a prespecified definition of relevance. Methods In a clinical setup, 11 hip parameters were evaluated in 101 patients (126 hips) by two observers and the interobserver difference was calculated. All parameters were normalized to an anatomically defined neutral pelvic orientation with the help of a lateral pelvic radiograph and specific software. Differences between nonnormalized and normalized values were calculated (effect of normalization). In an experimental setup involving 20 cadaver pelves (40 hips), the maximum range for each parameter was computed with the pelvis rotated (range, −12° to 12°) and tilted (range, −24° to 24°). ‘‘Ultimately’’ relevant changes existed if the effect of normalization exceeded the interobserver difference (eg, 37% versus 6% for prevalence of a positive crossover sign) and/or the maximum experimental range exceeded 1 SD of interobserver difference (eg, 27% versus 6% for anterior acetabular coverage). Results In the clinical setup, all parameters except the ACM angle and craniocaudal acetabular coverage changed when being normalized, eg, effect of normalization for lateral center-edge angle, acetabular index, and sharp angle ranged from −5° to 4° (p values < 0.029). In the experimental setup, five parameters showed no major changes, whereas six parameters did change (all p values < 0.001). Ultimately relevant changes were found for anteroposterior acetabular coverage, retroversion index, and prevalence of a positive crossover or posterior wall sign. Conclusions Lateral center-edge angle, ACM angle, Sharp angle, acetabular and extrusion index, and craniocaudal acetabular coverage showed no relevant changes with varying pelvic orientation and can therefore be acquired independent from individual pelvic tilt and rotation in clinical practice. In contrast, anteroposterior acetabular coverage, crossover and posterior wall sign, and retroversion index call for specific efforts that address individual pelvic orientation such as computer-assisted evaluation of radiographs. Level of Evidence Level III, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.
Resumo:
Introdução: Os padrões de movimento podem sofrer alterações por atraso no timing de ativação e/ou modificações na sequência de recrutamento muscular, predispondo o indivíduo a disfunções, nomeadamente a dor lombo-pélvica. Objetivo: Investigar o timing e o padrão de ativação de músculos do core abdominal, durante o movimento de extensão da anca, do membro dominante, em indivíduos com e sem dor lombo- pélvica crónica inespecífica. Pretende-se, também, pesquisar a existência do padrão de ativação considerado “normal“ e verificar a relação entre o padrão de ativação e o tilt pélvico, em ambos os indivíduos. Métodos: Estudo transversal, com 64 estudantes universitários, divididos em dois grupos: 31 sem e 33 com dor lombo-pélvica. Através de eletromiografia de superfície foi recolhida a atividade muscular dos Eretores da Espinha ipsilateral e contralateral, Glúteo Máximo e Bicípite Femoral ipsilaterais. Foi analisado o timing de ativação muscular e as respetivas ordens de ativação. Adicionalmente foi medido o tilt pélvico. Resultados: O grupo com dor lombo-pélvica apresentou um atraso significativo no timing de ativação dos músculos Glúteo Máximo ipsilateral (t=-3,171;p=0,002) e Bicípite Femoral ipsilateral (t=-2,092;p=0,041), em comparação com o grupo sem dor. Verificou-se uma associação significativa entre as 5 ordens de ativação mais frequentes e a presença de dor lombo-pélvica (xf2=11,54;p=0,015). A ordem de ativação "normal" – Glúteo Máximo ipsilateral>Bicípite Femoral ipsilateral>Eretor da Espinha contralateral>Eretor da Espinha ipsilateral – não foi utilizada. Verificou-se que o Bicípite Femoral ipsilateral foi maioritariamente o primeiro a ativar-se e o Glúteo Máximo ipsilateral o último em ambos os grupos. Verificou-se um tilt pélvico significativamente superior nos indivíduos que ativam primeiro o Bicípite Femoral ipsilateral nos grupos com (U=51;p=0,001) e sem dor (U=41p=0,001). Conclusão: Os indivíduos com dor lombo-pélvica apresentaram um atraso no timing de ativação dos músculos do core abdominal. Os resultados parecem refutar a ordem de ativação "normal" que tem sido proposta. Não foi possível apoiar nem contestar a teoria de que um atraso na ativação do Glúteo Máximo está associado com dor lombo-pélvica.
Resumo:
It is usual to find athletes that can perform de curl up test easily, but are unable to maintain the stabilization of the low back during the double straight leg lowering (DSLL). In spite of having strong abdominal muscles, its stabilization role seems not to be effective. Thus, the purpose of this study was to verify the relation among individuals with strong abdominal muscles and the ability in perform posterior pelvic tilt (PPT); the ability to stabilize the low back during the DSLL and the eletromyographic activity of the abdominal muscles. Eighteen male subjects (aged 19.27 ± 3.5), without history of muscle skeletal dysfunction, performed both the PPT and DSLL tests. During these tests electromyographic signals of the rectus abdominis (RA), obliquus internus abdominis (01) and obliquus externus abdominis (OE) were recorded, the angle of the hip and the pressure under the low back were measured The results of analyses of variance (ANOVA) show that most volunteers accomplished the PPT test, actively flattening the low back with regular or good quality. However, none of them was able to stabilize the low back during the DSLL test. During the PPT test all abdominal muscle portions analysed were activated without significant differences. In an attempt of maintaining the lumbo-pelvic region stabilized during the DSLL, it was observed a tendency of higher bilateral activation of OE when compared to RA and 01 muscle portions between 70 and 20 degrees of hip flexion.
Resumo:
Evaluating the ability to rectify and maintain lumbar adjustment can contribute toward the understanding of the behavior of abdominal muscles and their participation in the stability of pelvic muscles in dancers during the posterior pelvic tilt and double straight leg lowering tests. Nine healthy volunteers (male and female ballet dancers; age mean: 25.9 ±7.37 years) underwent maximal isometric voluntary contraction (MIVC), isometric voluntary contraction at 50% of MIVC, posterior pelvic tilt (PPT) and double straight leg lowering (DSLL) tests. The tests were carried out in a single day, with 3 repetitions each. During the tests, electromygraphic signals of the rectus abdominis, obliquus internus and obliquus externus were recorded. The signal acquisition system was made up of bipolar surface electrodes, electrogoniometer and an electromechanic device (pressure sensor), which were connected to a signal conditioner module. Root mean square values of each muscle during the DSLL and PPT were converted into percentage of activation of 50% MIVC. Lower back pressure was submitted to the same process. ANOVA with repeated measures was performed, with the level of significance set at p < 0.05. The results revealed that all dancers were able to maintain posterior pelvic tilt and there was trend toward greater activation of the bilateral obliquus internus muscle. In an attempt to keep the pelvic region stabilized during DSLL, there was a greater contribution from the obliquus externus muscle in relation to other abdominal muscles.
Resumo:
Hamstring strain injuries (HSIs) are common in a number of sports and incidence rates have not declined in recent times. Additionally, the high rate of recurrent injuries suggests that our current understanding of HSI and re-injury risk is incomplete. Whilst the multifactoral nature of HSIs is agreed upon by many, often individual risk factors and/or causes of injury are examined in isolation. This review aims to bring together the causes, risk factors and interventions associated with HSIs to better understand why HSIs are so prevalent. Running is often identified as the primary activity type for HSIs and given the high eccentric forces and moderate muscle strain placed on the hamstrings during running these factors are considered to be part of the aetiology of HSIs. However, the exact causes of HSIs remain unknown and whilst eccentric contraction and muscle strain purportedly play a role, accumulated muscle damage and/or a single injurious event may also contribute. Potentially, all of these factors interact to varying degrees depending on the injurious activity type (i.e. running, kicking). Furthermore, anatomical factors, such as the biarticular organization, the dual innervations of biceps femoris (BF), fibre type distribution, muscle architecture and the degree of anterior pelvic tilt, have all been implicated. Each of these variables impact upon HSI risk via a number of different mechanisms that include increasing hamstring muscle strain and altering the susceptibility of the hamstrings to muscle damage. Reported risk factors for HSIs include age, previous injury, ethnicity, strength imbalances, flexibility and fatigue. Of these, little is known, definitively, about why previous injury increases the risk of future HSIs. Nevertheless, interventions put in place to reduce the incidence of HSIs by addressing modifiable risk factors have focused primarily on increasing eccentric strength, correcting strength imbalances and improving flexibility. The response to these intervention programmes has been mixed with varied levels of success reported. A conceptual framework is presented suggesting that neuromuscular inhibition following HSIs may impede the rehabilitation process and subsequently lead to maladaptation of hamstring muscle structure and function, including preferentially eccentric weakness, atrophy of the previously injured muscles and alterations in the angle of peak knee flexor torque. This remains an area for future research and practitioners need to remain aware of the multifactoral nature of HSIs if injury rates are to decline.
Resumo:
The objective of this study was to explore whether differences in standing and sitting postures of youth with idiopathic scoliosis could be detected from quantitative analysis of digital photographs. Standing and sitting postures of 50 participants aged 10–20-years-old with idiopathic scoliosis (Cobb angle: 15° to 60°) were assessed from digital photographs using a posture evaluation software program. Based on the XY coordinates of markers, 13 angular and linear posture indices were calculated in both positions. Paired t-tests were used to compare values of standing and sitting posture indices. Significant differences between standing and sitting positions (p < 0.05) were found for head protraction, shoulder elevation, scapula asymmetry, trunk list, scoliosis angle, waist angles, and frontal and sagittal plane pelvic tilt. Quantitative analysis of digital photographs is a clinically feasible method to measure standing and sitting postures among youth with scoliosis and to assist in decisions on therapeutic interventions.
Resumo:
O sobrepeso e a obesidade (SO) têm atingido proporções epidêmicas, principalmente, em idade escolar, tornando-se um problema mundial de saúde. Muitas adaptações podem ocorrer na organização postural de crianças com SO, provocando, graves consequências. A avaliação postural pode colaborar para o entendimento destas alterações. O objetivo do presente estudo foi verificar alterações na postura dos membros inferiores de crianças com SO, através de metodologia específica. Vinte e dois indivíduos, sendo distribuídos de acordo com o sexo: 9 do feminino e 13 do masculino, com faixa etária entre 5-9 anos, participaram do estudo. Na avaliação postural, foram utilizados a fotogrametria e o software SAPo. Foram analisados os ângulos articulares dos membros inferiores e a projeção plantar do centro de gravidade. Foi utilizada estatística não-paramétrica descritiva, além dos testes de Kruskal-Wallis e de Mann-Whitney (p<0,05), para comparação entre os sexos. Ambos os sexos apresentaram anteroversão e leve rotação pélvica, à direita para o feminino e à esquerda para o masculino hiperextensão e valgismo de joelhos e valgismo tornozelos. O centro de gravidade apresentou 26,95% de anteriorização. Conclui-se que a avaliação postural nessa população foi congruente aos achados da literatura e a metodologia utilizada possibilitou quantificar os dados para futuras comparações.
Resumo:
Study design: Cross-sectional study. Objectives: To evaluate the efficacy of the Postural Assessment Software PAS/SAPO in the posture analysis of individuals with spinal cord injury (SCI) during sitting position and to analyze if the use of different types of seat cushions-gel and foam, with no cushion-can interfere in the individual's posture during sitting position. Setting: Centre of Rehabilitation at the University Hospital (FMRP-USP), Ribeirao Preto, Brazil. Methods: Eight individuals, four paraplegics and four tetraplegics with SCI and 20 healthy individuals participated in the study. Photos were taken of individuals in the sitting position using foam, gel cushions and with no cushion. They were analyzed using the PAS/SAPO. The alignment of the anterior-superior iliac spine (ASIS) and the posterior pelvic tilt were evaluated from the angle formed between the ASIS and the greater trochanter of the femur. Results: The group of healthy individuals presented the best postural alignment when compared with the group with SCI, both for the ASIS alignment (P < 0.05) and for the degree of posterior pelvic tilt (P < 0.05). No significant differences were found in the variables analyzed when the seat cushions were compared. Conclusion: The different types of cushions did not alter the sitting posture; however, individuals with SCI showed worse postural alignment than the healthy individuals. PAS/SAPO was demonstrated to be useful for postural assessment. Spinal Cord (2012) 50, 627-631; doi:10.1038/sc.2012.7; published online 21 February 2012
Resumo:
The purpose of this study was to validate the accuracy, consistency, and reproducibility/reliability of a new method for correction of pelvic tilt and rotation of radiographic hip parameters for pincer type of femoroacetabular impingement on an anteroposterior pelvic radiograph. Thirty cadaver hips and 100 randomized, blinded AP pelvic radiographs were used for investigation. To detect the software accuracy, the calculated femoral head coverage and classic hip parameters determined with our software were compared to reference measurements based on CT scans or conventional radiographs in a neutral orientation as gold standard. To investigate software consistency, differences among the different parameters for each cadaver pelvis were calculated when reckoned back from a random to the neutral orientation. Intra- and interobserver comparisons were used to analyze the reliability and reproducibility of all parameters. All but two parameters showed a good-to-very good accuracy with the reference measurements. No relevant systematic errors were detected in the Bland-Altman analysis. Software consistency was good-to-very good for all parameters. A good-to-very good reliability and reproducibility was found for a substantial number of the evaluated radiographic acetabular parameters. The software appears to be an accurate, consistent, reliable, and reproducible method for analysis of acetabular pathomorphologies.