1000 resultados para Pelvic Support Defects


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Abdominoperineal resection (APR) following radiotherapy is associated with a high rate of perineal wound complications. The anterolateral thigh (ALT) flap, combined with the vastus lateralis (VL) muscle, can cover complex perineal and pelvic anteroposterior defects. This is used for the first time transabdominally through the pelvis and the perineum (TAPP) in the infero-posterior directions; this technique has been described and illustrated in this study. METHODS: Among over 90 patients who underwent perineal reconstruction between May 2004 and June 2011, six patients presented high-grade tumours invading perineum, pelvis and sacrum, thereby resulting in a continuous anteroposterior defect. ALT + VL TAPP reconstructions were performed after extended APR and, subsequently, sacrectomy. Patients were examined retrospectively to determine demographics, operative time, complications (general and flap-related), time to complete healing and length of hospital stay. Long-term flap coverage, flap volume stability and functional and aesthetic outcomes were assessed. RESULTS: Mean operating time of the reconstruction was 290 min. No deaths occurred. One patient presented partial flap necrosis. Another patient presented a novel wound dehiscence after flap healing, due to secondary skin dissemination of the primary tumour. Following volumetric flap analysis on serial post-operative CT scans, no significant flap atrophy was observed. All flaps fully covered the defects. No late complications such as fistulas or perineal hernias occurred. Donor-site recovery was uneventful with no functional deficits. CONCLUSIONS: The use of the ALT + VL flap transabdominally is an innovative method to reconstruct exceptionally complex perineal and pelvic defects extending up to the lower back. This flap guarantees superior bulk, obliterating all pelvic dead space, with the fascia lata (FL) supporting the pelvic floor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims To compare magnetic resonance imaging (MRI) of the pelvic floor musculature (PFM), bladder neck and urethral sphincter morphology under three conditions (rest, PFM maximal voluntary contraction (MVC), and straining) in older women with symptoms of stress (SUI) or mixed urinary incontinence (MUI) or without incontinence. Methods This 2008–2012 exploratory observational cohort study was conducted with community-dwelling women aged 60 and over. Sixty six women (22 per group), mean age of 67.7 ± 5.2 years, participated in the study. A 3 T MRI examination was conducted under three conditions: rest, PFM MVC, and straining. ANOVA or Kruskal–Wallis tests (data not normally distributed) were conducted, with Bonferroni correction, to compare anatomical measurements between groups. Results Women with MUI symptoms had a lower PFM resting position (M-Line P = 0.010 and PC/H-line angle P = 0.026) and lower pelvic organ support (urethrovesical junction height P = 0.013) than both continent and SUI women. Women with SUI symptoms were more likely to exhibit bladder neck funneling and a larger posterior urethrovesical angle at rest than both continent and MUI women (P = 0.026 and P = 0.008, respectively). There were no significant differences between groups on PFM MVC or straining. Conclusions Women with SUI and MUI symptoms present different morphological defects at rest. These observations emphasize the need to tailor UI interventions to specific pelvic floor defects and UI type in older women.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims To compare magnetic resonance imaging (MRI) of the pelvic floor musculature (PFM), bladder neck and urethral sphincter morphology under three conditions (rest, PFM maximal voluntary contraction (MVC), and straining) in older women with symptoms of stress (SUI) or mixed urinary incontinence (MUI) or without incontinence. Methods This 2008–2012 exploratory observational cohort study was conducted with community-dwelling women aged 60 and over. Sixty six women (22 per group), mean age of 67.7 ± 5.2 years, participated in the study. A 3 T MRI examination was conducted under three conditions: rest, PFM MVC, and straining. ANOVA or Kruskal–Wallis tests (data not normally distributed) were conducted, with Bonferroni correction, to compare anatomical measurements between groups. Results Women with MUI symptoms had a lower PFM resting position (M-Line P = 0.010 and PC/H-line angle P = 0.026) and lower pelvic organ support (urethrovesical junction height P = 0.013) than both continent and SUI women. Women with SUI symptoms were more likely to exhibit bladder neck funneling and a larger posterior urethrovesical angle at rest than both continent and MUI women (P = 0.026 and P = 0.008, respectively). There were no significant differences between groups on PFM MVC or straining. Conclusions Women with SUI and MUI symptoms present different morphological defects at rest. These observations emphasize the need to tailor UI interventions to specific pelvic floor defects and UI type in older women.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

El prolapso del piso pélvico es una entidad frecuente, especialmente en pacientes postmenopáusicas y en su gran mayoría requiere tratamiento quirúrgico. En este estudio comparamos la aparición de complicaciones postoperatorias tempranas entre la colporrafia anterior con técnica clásica (TC) versus la colporrafia anterior con técnica de sitio especifico (CSE). Se realizó un estudio observacional analítico, retrospectivo, de dos cohortes de pacientes que requirieron colporrafia anterior entre agosto de 2009 hasta junio de 2012. Las características de cada grupo fueron homogéneas y comparables. El desenlace de mayor frecuencia fue dehiscencia de la línea de sutura, sin embargo, no se encontraron diferencias estadísticamente significativas entre las dos técnicas. La aparición de reprolapso temprano y el diagnóstico de abscesos o hematomas presentaron frecuencias que carecen de diferencia significativa. No hubo complicaciones tempranas graves tales como sangrado intraoperatoria mayor o lesiones vesicouretrales. Los resultados sugieren que las dos técnicas tienen una incidencia baja de complicaciones postoperatorias tempranas y por lo tanto parecen ser seguros dentro del manejo quirúrgico del prolapso del componente anterior del piso pélvico.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conventional procedures used to assess the integrity of corroded piping systems with axial defects generally employ simplified failure criteria based upon a plastic collapse failure mechanism incorporating the tensile properties of the pipe material. These methods establish acceptance criteria for defects based on limited experimental data for low strength structural steels which do not necessarily address specific requirements for the high grade steels currently used. For these cases, failure assessments may be overly conservative or provide significant scatter in their predictions, which lead to unnecessary repair or replacement of in-service pipelines. Motivated by these observations, this study examines the applicability of a stress-based criterion based upon plastic instability analysis to predict the failure pressure of corroded pipelines with axial defects. A central focus is to gain additional insight into effects of defect geometry and material properties on the attainment of a local limit load to support the development of stress-based burst strength criteria. The work provides an extensive body of results which lend further support to adopt failure criteria for corroded pipelines based upon ligament instability analyses. A verification study conducted on burst testing of large-diameter pipe specimens with different defect length shows the effectiveness of a stress-based criterion using local ligament instability in burst pressure predictions, even though the adopted burst criterion exhibits a potential dependence on defect geometry and possibly on material`s strain hardening capacity. Overall, the results presented here suggests that use of stress-based criteria based upon plastic instability analysis of the defect ligament is a valid engineering tool for integrity assessments of pipelines with axial corroded defects. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Congenital heart disease (CHD) is the most common birth defect and the leading cause of mortality in the first year of life. In fetuses with a heart defect, chromosomal abnormalities are very frequent. Besides aneuploidy, 22q11.2 deletion is one of the most recognizable chromosomal abnormalities causing CHD. The frequency of this abnormality varies in nonselected populations. This study aimed to investigate the incidence of the 22q11.2 deletion and other chromosomal alterations in a Brazilian sample of fetuses with structural cardiac anomalies detected by fetal echocardiography. In a prospective study, 68 fetuses with a heart defect were evaluated. Prenatal detection of cardiac abnormalities led to identification of aneuploidy or structural chromosomal anomaly in 35.3% of these cases. None of the fetuses with apparently normal karyotypes had a 22q11.2 deletion. The heart defects most frequently associated with chromosomal abnormalities were atrioventricular septal defect (AVSD), ventricular septal defect (VSD), and tetralogy of Fallot. Autosomal trisomies 18 and 21 were the most common chromosomal abnormalities. The study results support the strong association of chromosome alterations and cardiac malformation, especially in AVSD and VSD, for which a chromosome investigation is indicated. In fetuses with an isolated conotruncal cardiopathy, fluorescence in situ hybridization (FISH) to investigate a 22q11.2 deletion is not indicated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The 'integral theory of pelvic floor dysfunction', first proposed by Petros and Ulmsten in 1990, claims that anterior vaginal wall relaxation is associated with symptoms of urgency, frequency, nocturia and urge incontinence. A retrospective study was designed to test this hypothesis. Imaging data and urodynamic reports from 272 women suffering from symptoms of lower urinary tract dysfunction were evaluated. Opening of the retrovesical angle, bladder neck descent, urethral rotation and descent of a cystocele during Valsalva were used to quantify anterior vaginal wall laxity None of the tested parameters were associated with symptoms and signs of detrusor overactivity. On the contrary, patients with higher grades of urethral and bladder descent were less likely to suffer from nocturia and urge incontinence and were less likely to leave sensory urgency and detrusor instability diagnosed on urodynamic testing. The findings of this study therefore do not support this hypothesis of the 'integral theory'.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate the low-energy electronic transport across grain boundaries in graphene ribbons and infinite flakes. Using the recursive Green’s function method, we calculate the electronic transmission across different types of grain boundaries in graphene ribbons. We show results for the charge density distribution and the current flow along the ribbon. We study linear defects at various angles with the ribbon direction, as well as overlaps of two monolayer ribbon domains forming a bilayer region. For a class of extended defect lines with periodicity 3, an analytic approach is developed to study transport in infinite flakes. This class of extended grain boundaries is particularly interesting, since the K and K0 Dirac points are superposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: We set out to determine if insertion of a retropubic tension-free vaginal tape (TVT) sling at the time of pelvic organ prolapse surgery improves continence outcomes in women with pre-operative occult stress incontinence (OSI) or asymptomatic urodynamic stress incontinence (USI). METHODS: We conducted a randomised controlled study of prolapse surgery with or without a TVT midurethral sling. The pre- and post-operative assessment at 6 months included history, physical examination and urodynamic testing. Quality of life (QOL) and treatment success was assessed with the UDI-6 SF, IIQ-7 SF and a numerical success score. The primary outcome was symptomatic stress urinary incontinence (SUI) requiring continence surgery (TVT) at 6 months. Long-term follow-up continued to a minimum of 24 months. Secondary outcomes were quality of life parameters. RESULTS: Eighty women received prolapse surgery alone (n = 43) or prolapse surgery with concurrent TVT (n = 37). Six months following prolapse surgery 3 out of 43 (7 %) patients in the no TVT group requested sling surgery compared with 0 out of 37 (0 %) in the TVT group (ARR 7 % [95 %CI: 3 to 19 %], p = 0.11). After 24 months there was one further participant in the no TVT group who received a TVT for treatment of SUI compared with none in the TVT group (4 out of 43, 9.3 % versus 0 out of 37; ARR 9.3 % [95 %CI: -1 to 22 %], p = 0.06). Both groups showed improvement in QOL difference scores for within-group analysis, without difference between groups. CONCLUSION: These results support a policy that routine insertion of a sling in women with OSI at the time of prolapse repair is questionable and should be subject to shared decision-making between clinician and patient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vaginal delivery can cause lesions of the various pelvic structures responsible for the mechanisms of continence. These lesions may perhaps be prevented in the future by measuring pressure generated during childbirth. Tear of the anal sphincter during childbirth is a marker of a global impairment of the urinary, ano-rectal and sexual pelvic functions in the short and medium term. Persistence of a defect of the anal sphincter is frequent in spite of immediate suture. The correlation between these defects and ano-rectal incontinence are not established in our experience. The quality of the contraction of the sphincter complex and pubo-rectal sling seems to play a more important role in ano-rectal continence after a traumatic childbirth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

STUDY QUESTION: What are the long term trends in the total (live births, fetal deaths, and terminations of pregnancy for fetal anomaly) and live birth prevalence of neural tube defects (NTD) in Europe, where many countries have issued recommendations for folic acid supplementation but a policy for mandatory folic acid fortification of food does not exist? METHODS: This was a population based, observational study using data on 11 353 cases of NTD not associated with chromosomal anomalies, including 4162 cases of anencephaly and 5776 cases of spina bifida from 28 EUROCAT (European Surveillance of Congenital Anomalies) registries covering approximately 12.5 million births in 19 countries between 1991 and 2011. The main outcome measures were total and live birth prevalence of NTD, as well as anencephaly and spina bifida, with time trends analysed using random effects Poisson regression models to account for heterogeneities across registries and splines to model non-linear time trends. SUMMARY ANSWER AND LIMITATIONS: Overall, the pooled total prevalence of NTD during the study period was 9.1 per 10 000 births. Prevalence of NTD fluctuated slightly but without an obvious downward trend, with the final estimate of the pooled total prevalence of NTD in 2011 similar to that in 1991. Estimates from Poisson models that took registry heterogeneities into account showed an annual increase of 4% (prevalence ratio 1.04, 95% confidence interval 1.01 to 1.07) in 1995-99 and a decrease of 3% per year in 1999-2003 (0.97, 0.95 to 0.99), with stable rates thereafter. The trend patterns for anencephaly and spina bifida were similar, but neither anomaly decreased substantially over time. The live birth prevalence of NTD generally decreased, especially for anencephaly. Registration problems or other data artefacts cannot be excluded as a partial explanation of the observed trends (or lack thereof) in the prevalence of NTD. WHAT THIS STUDY ADDS: In the absence of mandatory fortification, the prevalence of NTD has not decreased in Europe despite longstanding recommendations aimed at promoting peri-conceptional folic acid supplementation and existence of voluntary folic acid fortification. FUNDING, COMPETING INTERESTS, DATA SHARING: The study was funded by the European Public Health Commission, EUROCAT Joint Action 2011-2013. HD and ML received support from the European Commission DG Sanco during the conduct of this study. No additional data available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rolling element bearings are essential components of rotating machinery. The spherical roller bearing (SRB) is one variant seeing increasing use, because it is self-aligning and can support high loads. It is becoming increasingly important to understand how the SRB responds dynamically under a variety of conditions. This doctoral dissertation introduces a computationally efficient, three-degree-of-freedom, SRB model that was developed to predict the transient dynamic behaviors of a rotor-SRB system. In the model, bearing forces and deflections were calculated as a function of contact deformation and bearing geometry parameters according to nonlinear Hertzian contact theory. The results reveal how some of the more important parameters; such as diametral clearance, the number of rollers, and osculation number; influence ultimate bearing performance. Distributed defects, such as the waviness of the inner and outer ring, and localized defects, such as inner and outer ring defects, are taken into consideration in the proposed model. Simulation results were verified with results obtained by applying the formula for the spherical roller bearing radial deflection and the commercial bearing analysis software. Following model verification, a numerical simulation was carried out successfully for a full rotor-bearing system to demonstrate the application of this newly developed SRB model in a typical real world analysis. Accuracy of the model was verified by comparing measured to predicted behaviors for equivalent systems.