59 resultados para Pcdd
Resumo:
Recent investigations have demonstrated the presence of an unidentified source of polychlorinated dibenzo-p-dioxins (PCDDs) in the coastal zone of Queensland (Australia). The present study provides new information on the possible PCDD sources and their temporal input to this environment. Two estuarine sediment cores were collected in northern Queensland for which radiochemical chronologies were established. Core sections from different depositional ages, up to three centuries, have been analyzed for 2,3,7,8-substituted PCDDs and polychlorinated dibenzofurans (PCDFs). Variations of PCDD concentrations in the sediment cores over several centuries of depositional history were relatively small, and elevated PCDD levels were still present in sediment slices from the early 17th century. PCDD/F isomer patterns and congener profiles in sediments deposited during the last 350 years were almost identical and correlated well to the characteristic profiles observed in surface sediments and soils from the entire Queensland coastline. Profiles were dominated by higher chlorinated PCDDs, in particular octachlorodibenzodioxin (OCDD), whereas PCDF concentrations were below or near the limit of detection. These results indicate the presence of a PCDD source prior to industrialization and production of commercial organochlorine products. Further, the present study demonstrates that PCDD input patterns have been similar along an extensive but localized area over at least several centuries, contributing relatively high concentrations of PCDDs to the coastal system of Queensland.
Resumo:
The concentrations of SOCs in leaves of an evergreen Australian native tree (Melaleuca leucadendra) and grass collected in Brisbane, Australia were determined. The concentrations of PCDD/Fs and PAHs in the leaf tissue were comparable to those reported for urbanised areas in other industrialised countries. A distinct difference in the compound profiles between the leaves of the two species was observed, with higher concentrations of the lower molecular mass PAHs and PCDD/Fs and lower concentrations of the higher molecular mass PAHs and PCDD/Fs in the Melaleuca leaves relative to the grass leaves. The interspecies differences are explained on the basis of the larger size of the lipophilic compartment (for compounds with low K-OA) and the lower ratio of surface area to volume in the Melaleuca leaves. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
Recent studies have demonstrated the occurrence of elevated levels of higher chlorinated PCDDs in the coastal environment of Queensland, Australia. This study presents new data for OCDD contamination and full PCDD/F profile analysis in the environment of Queensland. Marine sediments, irrigation drain sediments and topsoil were collected from sites that were expected to be influenced by specific land-use types. High OCDD concentrations were associated mainly with sediments collected near the mouth of rivers which drain into large catchments in the tropical and subtropical regions. Further, analysis of sediments from irrigation drains could be clearly differentiated on the basis of OCDD contamination, with high concentrations in samples from sugarcane drains collected from coastal regions, and low concentrations in drain sediments from drier inland cotton growing areas. PCDD/F congener-specific analysis demonstrated almost identical congener profiles in all samples collected along the coastline. This indicates the source to be widespread. Profiles were dominated by higher chlorinated PCDDs, in particular OCDD whereas 2,3,7,8-substituted PCDFs were below the limit of quantification in the majority of samples. The full PCDD/F profile analysis of samples strongly resemble those reported for lake sediments from Mississippi and kaolinite samples from Germany, Strong similarities to these samples with respect to congener profiles and isomer patterns may indicate the presence of a similar source and/or formation process that is yet unidentified. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
Recent findings of elevated PCDDs from an unknown source in the coastal marine environment of Queensland, Australia has instigated further investigations into the distribution of, and environments associated with the PCDD contamination. This study presents data for OCDD concentrations in the coastal, mountainous and inland environment of Queensland. Additionally, full 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins and dibenzofuran (PCDD/F) profiles from different land-use types and environments in the coastal region were analysed. Distinct east-west gradients were detected in topsoil collected from various bushland regions with elevated OCDD concentrations confined to the coastal region. However, PCDD/F results from topsoil and river sediments collected in the Queensland coastal region suggest that elevated OCDD concentrations cannot be attributed to any of the environments, land-use or industry types investigated. PCDD/F congener profiles from select samples were remarkably similar to those previously described in marine sediments collected along the entire Queensland coastline. In addition, kaolinite clay samples from Queensland exhibited elevated OCDD concentrations, and PCDD/F profiles in these samples were similar to those detected in kaolinite clays elsewhere. Natural formation processes have been hypothesised as the source of elevated PCDDs in Queensland and other locations, where similar PCDD/F profiles and the general lack of anthropogenic sources are evident. This study presents additional data supporting this hypothesis and provides further information that may assist in the identification of the processes involved in the natural formation of PCDDs. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Forest fires are suggested as a potential and significant source of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs), even though no studies to date provide sufficient evidence to confirm forest fires as a source of PCDD/Fs. Recent investigations in Gueensland, Australia have identified a widespread contamination of PCDDs (in particular OND) in soils and sediments in the coastal region from an unknown source of PCDD/Fs. Queensland is predominately rural; it has few known anthropogenic sources of PCDD/Fs, whereas forest fires are a frequent occurrence. This study was conducted to assess forest fires as a potential source of the unknown PCDD/F contamination in Queensland. A combustion experiment was designed to assess the overall mass of PCDD/Fs before and after a simulated forest fire. The results from this study did not identify an increase in Sigma-PCDD/Fs or OCDD after the combustion process. However, specific non-2,3,7,8 substituted lower chlorinated PCDD/Fs were elevated after the combustion process, suggesting formation from a precursor. The results from this study indicate that forest fires are unlikely to be the source of the unknown PCDD contamination in Gueensland, rather they are a key mechanism for the redistribution of PCDD/Fs from existing sources and precursors.
Resumo:
Potential risks of a secondary formation of polychlorinated dibenzodioxins/furans (PCDD/Fs) were assessed for two cordierite-based, wall-through diesel particulate filters (DPFs) for which soot combustion was either catalyzed with an iron- or a copper-based fuel additive. A heavy duty diesel engine was used as test platform, applying the eight-stage ISO 8178/4 C1 cycle. DPF applications neither affected the engine performance, nor did they increase NO, NO2, CO, and CO2 emissions. The latter is a metric for fuel consumption. THC emissions decreased by about 40% when deploying DPFs. PCDD/F emissions, with a focus on tetra- to octachlorinated congeners, were compared under standard and worst case conditions (enhanced chlorine uptake). The iron-catalyzed DPF neither increased PCDD/F emissions, nor did it change the congener pattern, even when traces of chlorine became available. In case of copper, PCDD/F emissions increased by up to 3 orders of magnitude from 22 to 200 to 12 700 pg I-TEQ/L with fuels of < 2, 14, and 110 microg/g chlorine, respectively. Mainly lower chlorinated DD/Fs were formed. Based on these substantial effects on PCDD/F emissions, the copper-catalyzed DPF system was not approved for workplace applications, whereas the iron system fulfilled all the specifications of the Swiss procedures for DPF approval (VERT).
Resumo:
Occurrence of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) was evaluated in sepiolite as a widely employed binder and anti-caking agent for animal feed. Also, naturally contaminated kaolinitic clay was used for comparative purposes. Since sepiolite shows remarkable adsorption properties, particular interest was paid to the extraction steps as they become critical for the final determination of these pollutants in such matrixes. Furthermore, classical Soxhlet extraction using different extracting strategies as well as acid treatment were carried out with simultaneous liquid-liquid extraction. Results obtained depended on the extraction procedure applied. Acid treatment or Soxhlet extraction using a mixture of toluene:ethanol as solvent allowed to reach the minimum requirements of recovery rates. However, Soxhlet extraction using a mixture cyclohexane:toluene as extracting solvent did not allow to comply with minimum specifications for recovery. Significant differences were obtained in TEQ units when acid treatment was applied in comparison to Soxhlet extraction. This fact can be explained because the use of drastic acid conditions allows removing strongly adsorbed analytes which can be uniquely extracted after a total destruction of the crystalline structure of sepiolite. On the contrary, Soxhlet extraction was not able to destroy the structure of sepiolite and as a consequence the PCDDs/Fs were strongly adsorbed in the internal structure of the mineral. From biological point of view the availability of these toxicants constitutes a critical aspect playing an important role in the final decision choosing particular analytical procedures. Then, acid conditions in the digestive tract should be taken into account. In this scenario, a bioaccumulation study was conducted to evaluate the transference of PCDDs/PCDFs from the sepiolite into the animal tissues when fed with feed containing sepiolite. To this end, chickens were used as a model to examine the bioavailability of PCDDs/PCDFs. Four groups of chickens were exposed through their diet to a control feed, feed with 3% w/w sepiolite as additive, feed contaminated with PCDDs/PCDFs at concentration around 2.8 pg WHO-TEQ/g and feed with 2% of a contaminated kaolinitic clay (460 pg TEQ/g mineral). Livers of the four studied groups were analyzed throughout the exposure period. Results of this trial showed that the performance of broilers was not affected by the presence of dioxins at levels tested, and chickens did not show any abnormal behaviour. Dioxins intentionally added to the diet were absorbed and accumulated in the liver in a significant manner, whereas the PCDDs/Fs from sepiolite were not available for chickens since livers from broilers fed 3% sepiolite presented similar WHO-TEQ values than those from broilers fed control diet.
Resumo:
Polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofuranes (PCDF) and polychlorinated biphenyls (PCB) are types of persistent and bioaccumulating organic pollutants with enhanced chronic toxicity and carcinogenic properties and can be considered as environmental indicators of anthropogenic activities since their occurrence in the environment can always be linked to anthropogenic activities. The present paper reviews the main sources and behaviour of these compounds in the environment as well as the risks they represent to man and biota.
Resumo:
The quantitative structure property relationship (QSPR) for the boiling point (Tb) of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) was investigated. The molecular distance-edge vector (MDEV) index was used as the structural descriptor. The quantitative relationship between the MDEV index and Tb was modeled by using multivariate linear regression (MLR) and artificial neural network (ANN), respectively. Leave-one-out cross validation and external validation were carried out to assess the prediction performance of the models developed. For the MLR method, the prediction root mean square relative error (RMSRE) of leave-one-out cross validation and external validation was 1.77 and 1.23, respectively. For the ANN method, the prediction RMSRE of leave-one-out cross validation and external validation was 1.65 and 1.16, respectively. A quantitative relationship between the MDEV index and Tb of PCDD/Fs was demonstrated. Both MLR and ANN are practicable for modeling this relationship. The MLR model and ANN model developed can be used to predict the Tb of PCDD/Fs. Thus, the Tb of each PCDD/F was predicted by the developed models.
Resumo:
Tesis (Maestro en Ciencias de la Ingeniería Mecánica con Especialidad en Materiales) UANL, 2002
Resumo:
Los autores desean agradecer a la Universidad de Alicante por su apoyo económico para llevar a cabo esta investigación y el proyecto CTQ 2008-05520 del Ministerio de Ciencia e Innovación, Prometeo 2009/043/FEDER de la Comunidad Valenciana de España.
Resumo:
PCDD/F emissions from three light-duty diesel vehicles–two vans and a passenger car–have been measured in on-road conditions. We propose a new methodology for small vehicles: a sample of exhaust gas is collected by means of equipment based on United States Environmental Protection Agency (U.S. EPA) method 23A for stationary stack emissions. The concentrations of O2, CO, CO2, NO, NO2 and SO2 have also been measured. Six tests were carried out at 90-100 km/h on a route 100 km long. Two additional tests were done during the first 10 minutes and the following 60 minutes of the run to assess the effect of the engine temperature on PCDD/F emissions. The emission factors obtained for the vans varied from 1800 to 8400 pg I-TEQ/Nm3 for a 2004 model year van and 490-580 pg I-TEQ/Nm3 for a 2006 model year van. Regarding the passenger car, one run was done in the presence of a catalyst and another without, obtaining emission factors (330-880 pg I-TEQ/Nm3) comparable to those of the modern van. Two other tests were carried out on a power generator leading to emission factors ranging from 31 to 78 pg I-TEQ/Nm3. All the results are discussed and compared with literature.
Resumo:
Mode of access: Internet.