990 resultados para Patrol vessels
Resumo:
Previous papers related to the optimization of pressure vessels have considered the optimization of the nozzle independently from the dished end. This approach generates problems such as thickness variation from nozzle to dished end (coupling cylindrical region) and, as a consequence, it reduces the optimality of the final result which may also be influenced by the boundary conditions. Thus, this work discusses shape optimization of axisymmetric pressure vessels considering an integrated approach in which the entire pressure vessel model is used in conjunction with a multi-objective function that aims to minimize the von-Mises mechanical stress from nozzle to head. Representative examples are examined and solutions obtained for the entire vessel considering temperature and pressure loading. It is noteworthy that different shapes from the usual ones are obtained. Even though such different shapes may not be profitable considering present manufacturing processes, they may be competitive for future manufacturing technologies, and contribute to a better understanding of the actual influence of shape in the behavior of pressure vessels. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The practicability of estimating directional wave spectra based on a vessel`s 1st order response has been recently addressed by several researchers. Different alternatives regarding statistical inference methods and possible drawbacks that could arise from their application have been extensively discussed, with an apparent preference for estimations based on Bayesian inference algorithms. Most of the results on this matter, however, rely exclusively on numerical simulations or at best on few and sparse full-scale measurements, comprising a questionable basis for validation purposes. This paper discusses several issues that have recently been debated regarding the advantages of Bayesian inference and different alternatives for its implementation. Among those are the definition of the best set of input motions, the number of parameters required for guaranteeing smoothness of the spectrum in frequency and direction and how to determine their optimum values. These subjects are addressed in the light of an extensive experimental campaign performed with a small-scale model of an FPSO platform (VLCC hull), which was conducted in an ocean basin in Brazil. Tests involved long and short crested seas with variable levels of directional spreading and also bimodal conditions. The calibration spectra measured in the tank by means of an array of wave probes configured the paradigm for estimations. Results showed that a wide range of sea conditions could be estimated with good precision, even those with somewhat low peak periods. Some possible drawbacks that have been pointed out in previous works concerning the viability of employing large vessels for such a task are then refuted. Also, it is shown that a second parameter for smoothing the spectrum in frequency may indeed increase the accuracy in some situations, although the criterion usually proposed for estimating the optimum values (ABIC) demands large computational effort and does not seem adequate for practical on-board systems, which require expeditious estimations. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Lengths of silastic tubing were inserted into the peritoneal cavity of rats or rabbits. By two weeks the free-floating implants had become covered by a capsule consisting of several layers of macrophage-derived myofibroblasts and collagen matrix overlaid by a single layer of mesothelial cells. The tubing was removed from the harvested implant and the tissue everted. This now resembled an artery with an inner lining of mesothelial cells (the intima), a media of myofibroblasts, and an outer collagenous adventitia. The tube of living tissue was grafted by end-to-end anastomoses into the transected carotid artery or abdominal aorta of the same animal in which the tissue had been grown, where it remained parent for four months and developed structures resembling elastic lamellae, The myofibroblasts developed a high volume fraction of myofilaments and became responsive to contractile and relaxing agents similar to smooth muscle cells of the adjacent artery wall.
Resumo:
Objective: To evaluate whether the number of vessels disease has an impact on clinical outcomes as well as on therapeutic results accordingly to medical, percutaneous, or surgery treatment in chronic coronary artery disease. Methods: We evaluated 825 individuals enrolled in MASS study, a randomized study to compare treatment options for single or multivessel coronary artery disease with preserved left ventricular function, prospectively followed during 5 years. The incidence of overall mortality and the composite end-point of death, myocardial infarction, and refractory angina were compared in three groups: single vessel disease (SVD n = 214), two-vessel disease (2VD n = 253) and three-vessel disease (3VD n = 358). The relationship between baseline variables and the composite end-point was assessed using a Cox proportional hazards survival model. Results: Most baseline characteristics were similar among groups, except age (younger in SVD and older in 3VD, p < 0.001), lower incidence of hypertension in SVD (p < 0.0001), and lower levels of total and LDL-cholesterol in 3VD (p = 0.004 and p = 0.005, respectively). There were no statistical differences in composite end-point in 5 years among groups independent of the kind of treatment; however, there was a higher mortality rate in 3VD (p < 0.001). When we stratified our analysis for each treatment option, bypass surgery was associated with a tower number of composite end-point in all groups (SVD p < 0.001, 2VD p = 0.002, 3VD p < 0.001). In multivariate analysis, we found higher mortality risk in 3VD comparing to SVD (p = 0.005, HR 3.14, 95%Cl 1.4-7.0). Conclusion: Three-vessel disease was associated with worse prognosis compared to single-or two-vessel disease in patients with stable coronary disease and preserved ventricular function at 5-year follow-up. In addition, event-free survival rates were higher after bypass surgery, independent of the number of vessels diseased in these subsets of patients. (c) 2008 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Resumo:
Objective: To analyze and compare the incidence and visual characteristics of blood vessels on the superior surface of vocal folds with polyps, nodules, and minimal structural alterations (ie, sulci, cysts, and mucosal bridges). Design: Cross-sectional study. Setting: Academic research. Patients: A total of 280 videolaryngoscopic images were randomly selected and classified into the following 4 groups of 70 patients each: the vocal nodule (VN) group, the polyp group, the minimal structural alterations (MSA) group, and the control group. Main Outcome Measures: Laryngoscopic images were assessed for visible blood vessels and for the orientation and characteristics of the vessels. Isolated ectasias with clear boundaries were excluded. Results: The highest incidence of visible vessels was observed in the MSA group (91.4%), followed by the polyp (77.1%), VN (44.7%), and control (31.4%) groups. Longitudinal and transverse vessels were found more frequently in the MSA (74.3% and 37.1%) and polyp (65.7% and 22.9%) groups than in the VN (34.3% and 12.9%) and control (25.7% and 5.7%) groups. Tangled vessels were found only in the MSA group (8.6%). Abrupt changes in the caliber of the vessels and sinuous vessels were ob served only in the polyp (21.4% and 5.7%) and MSA (61.4% and 27.1%) groups. Conclusions: The main differences in the incidence and characteristics of visible blood vessels occurred between 2 pairs of groups: MSA-polyp and VN-control. The incidence was significantly higher in the MSA group than in the polyp group, and the incidence in both the MSA group and the polyp group was also significantly higher than that in the VN and control groups. The greatest variations were found in the MSA group, including the presence of tangled blood vessels (which was observed only in this group).
Resumo:
Aims Compared with other non-steroid anti-inflammatory drugs (NSAIDs), aspirin is not correlated to hypertension. It has been shown that aspirin has unique vasodilator action in vivo, offering an explanation for the unique blood pressure effect of aspirin. In the present study, we investigate the mechanism whereby salicylates (aspirin and sodium salicylate) dilate blood vessels. Methods and results Rat aortic or mesenteric arterial rings were used to test the vascular effect of salicylates and other NSAIDs. RhoA translocation and the phosphorylation of MYPT1, the regulatory subunit of myosin light chain phosphatase, were measured by western blot, as evidenced for RhoA/Rho-kinase activation. Salicylates, but not other NSAIDs, relaxed contraction induced by most tested constrictors except for calyculin A, indicating that RhoA/Rho-kinase-mediated calcium sensitization is involved. The involvement of RhoA/Rho kinase in vasodilation by salicylates was confirmed by measurements of RhoA translocation and MYPT1 phosphorylation. The calculated half maximal inhibitory concentration (IC(50)) of vasodilation was apparently higher than that of cyclooxygenase inhibition, but comparable to that of proline-rich tyrosine kinase 2 (PYK2) inhibition. Over-expression of PYK2 induced RhoA translocation and MYPT1 phosphorylation, and these effects were markedly inhibited by sodium salicylate treatment. Consistent with the ex vitro vascular effects, sodium salicylate acutely decreased blood pressure in spontaneous hypertensive rats but not in Wistar Kyoto rats. Conclusion Salicylates dilate blood vessels through inhibiting PYK2-mediated RhoA/Rho-kinase activation and thus lower blood pressure.
Resumo:
Sox18 encodes a transcription factor known to be important for the development of blood vessels and hair follicles in mice. In order to study the functional conservation of this gene through evolution, we have isolated and characterized Sox18 in chickens. cSox18 shows a high degree of sequence homology to both the mouse and human orthologues, particularly in the high mobility group DNA-binding domain and to a lesser extent in the transcriptional activation domain. A region of unusually high sequence conservation at the C-terminus may represent a further, previously unrecognized functional domain. Both the chicken and human proteins appear to be truncated at the N-terminus relative to mouse SOX18. In situ hybridization analyses showed expression in the developing vasculature and feather follicles, consistent with reported expression in the mouse embryo. In addition, cSox18 mRNA was observed in the retina and claw beds. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
On 2 November 2001, the General Assembly of the United Nations Scientific, Economic and Cultural Organisation (UNESCO) adopted the convention on the Protection of the Underwater Cultural Heritage. Among the many complex issues addressed in the convention is the legal status of sunken state-owned vessels, including warships. Prior to the adoption of this convention, no conventional or customary international law existed with regards to the question of abandonment of state-owned vessels or the application of the principle of sovereign immunity to sunken state vessels. While difficulties between coastal states and maritime and former colonial powers resulted in a regime that does not comprehensively address the issues, the convention does provide some guidance in this regard and may provide a basis for further development.
Resumo:
The aim was to determine whether uptake of 5-hydroxytryptamine (5-HT) by the 5-HT transporter (SERT) modulates contractile responses to 5-HT in rat pulmonary arteries and whether this modulation is altered by exposure of rats to chronic hypoxia (10% oxygen; 8 h/day; 5 days). The effects of the SERT inhibitor, citalopram (100 nM), on contractions to 5-HT were determined in isolated ring preparations of pulmonary artery (intralobar and main) and compared with data obtained in systemic arteries. In intralobar pulmonary arteries citalopram produced a potentiation (viz. an increase in potency, pEC(50)) of 5-HT. The potentiation was endothelium-dependent in preparations from normoxic rats but endothelium-independent in preparations from hypoxic rats. In main pulmonary artery endothelium-independent potentiation was seen in preparations from hypoxic rats but no potentiation occurred in preparations from normoxic rats. In systemic arteries, citalopram caused endothelium-independent potentiation in aorta but no potentiation in mesenteric arteries; there were no differences between hypoxic and normoxic rats. It is concluded that SERT can influence the concentration of 5-HT in the vicinity of the vasoconstrictor receptors in pulmonary arteries. The data suggest that in pulmonary arteries from hypoxic rats, unlike normoxic rats, the SERT responsible for this effect is not in the endothelium and, hence, is probably in the smooth muscle. The data are compatible with reports that, in the pulmonary circulation, hypoxia induces/up-regulates SERT, and hence increases 5-HT uptake, in vascular smooth muscle. The findings may have implications in relation to the suggested use of SERT inhibitors in the treatment of pulmonary hypertension.
Resumo:
The objective of the present study was to assess the effects of the immunosuppressant rapamycin (Rapamune®, Sirolimus) on both resistance vessel responsiveness and atherosclerosis in apolipoprotein E-deficient 8-week-old male mice fed a normal rodent diet. Norepinephrine (NE)-induced vasoconstriction, acetylcholine (ACh)- and sodium nitroprusside (SNP)-induced vasorelaxation of isolated mesenteric bed, and atherosclerotic lesions were evaluated. After 12 weeks of orally administered rapamycin (5 mg·kg-1·day-1, N = 9) and compared with untreated (control, N = 9) animals, rapamycin treatment did not modify either NE-induced vasoconstriction (maximal response: 114 ± 4 vs 124 ± 10 mmHg, respectively) or ACh- (maximal response: 51 ± 8 vs 53 ± 5%, respectively) and SNP-induced vasorelaxation (maximal response: 73 ± 6 vs 74 ± 6%, respectively) of the isolated vascular mesenteric bed. Despite increased total cholesterol in treated mice (982 ± 59 vs 722 ± 49 mg/dL, P < 0.01), lipid deposition on the aorta wall vessel was significantly less in rapamycin-treated animals (37 ± 12 vs 68 ± 8 µm2 x 103). These results indicate that orally administered rapamycin is effective in attenuating the progression of atherosclerotic plaque without affecting the responsiveness of resistance vessels, supporting the idea that this immunosuppressant agent might be of potential benefit against atherosclerosis in patients undergoing therapy.
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Electrónica Industrial
Resumo:
This study aimed to determine the existence of blood vessels within ganglia of the myenteric plexus of the human esophagus and colon. At necropsy, 15 stillborns, newborns and children up to two years of age, with no gastrointestinal disorders, were examined. Rings of the esophagus and colon were analyzed and then fixed in formalin and processed for paraffin. Histological sections were stained by hematoxylin-eosin, Giemsa and immunohistochemistry for the characterization of endothelial cells, using antibodies for anti-factor VIII and CD31. Blood vessels were identified within the ganglia of the myenteric plexus of the esophagus, and no blood vessels were found in any ganglia of the colon. It was concluded that the ganglia of the myenteric plexus of the esophagus are vascularized, while the ganglia of the colon are avascular. Vascularization within the esophageal ganglia could facilitate the entrance of infectious agents, as well as the development of inflammatory responses (ganglionitis) and denervation, as found in Chagas disease and idiopathic achalasia. This could explain the higher frequency of megaesophagus compared with megacolon.
Resumo:
The present work focuses on the use of the life cycle assessment (LCA) and life cycle costing (LCC)methodologies to evaluate environmental and economic impacts of polymers and polymer composites materials and products. Initially a literature review is performed in order to assess the scope and limitations of existing LCA and LCC studies on these topics. Then, a case study, based on the production of a water storage glass-fibre reinforced polymer (GFRP) composite storage tank, is presented. The storage tank was evaluated via a LCA/LCC integrated model, a novel way of analysing the life cycle (LC) environmental and economic performances of structural products. The overarching conclusion of the review is that the environmental and economic performances of polymers composites in non-mobile applications are seldom assessed and never in a combined integrated way.