985 resultados para Patient simulation


Relevância:

100.00% 100.00%

Publicador:

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This study investigated the effectiveness of modules involving standardized patients and role-plays on training communication skills. The first module involved standardized patients and an Objective Structured Clinical Examination (OSCE); the second module consisted of peer role-plays and a written examination. A randomized posttest-only control group design with first-year nursing students was used. The intervention group received one-to-one communication training with direct oral feedback from the standardized patient. The control group had training with peer role-playing and mutual feedback. The posttest involved students' rating their self-efficacy, and real patients and clinical supervisors evaluated their communication skills. No significant differences were found between self-efficacy and patient ratings. However, the clinical supervisors rated the intervention group's communication skills to be significantly (p < 0.0001) superior. Assessments by clinical supervisors indicate that communication training modules including standardized patients and an OSCE are superior to communication training modules with peer role-playing.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The debriefing phase in human patient simulation is considered to be crucial for learning. To ensure good learning conditions, the use of small groups is recommended, which poses a major challenge when the student count is high. The use of large groups may provide an alternative for typical lecture-style education and contribute to a more frequently and repeated training which is considered to be important for achieving simulation competency. The purpose of the present study was to describe nursing students’ experiences obtained during the debriefing conducted in small and large groups with the use of a qualitative descriptive approach. The informants had participated in a human patient simulation situation either in large or small groups. Data was collected through the use of five focus-group interviews and analysed by content analysis. The findings showed that independent of group-size the informants experienced the learning strategies to be unfamiliar and intrusive, and in the large groups to such an extent that learning was hampered. Debriefing was perceived as offering excellent opportunities for transferable learning, and activity, predictability and preparedness were deemed essential. Small groups provided the best learning conditions in that safety and security were ensured, but were perceived as providing limited challenges to accommodate professional requirements as a nurse. Simulation competency as a prerequisite for learning was shown not to be developed isolated in conjunction with simulation, but depends on a systematic effort to build a learning community in the programme in general. The faculty needs to support the students to be conscious and accustomed to learning as a heightened experience of learning out of their comfort zone.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Since 1895, when X-rays were discovered, ionizing radiation became part of our life. Its use in medicine has brought significant health benefits to the population globally. The benefit of any diagnostic procedure is to reduce the uncertainty about the patient's health. However, there are potential detrimental effects of radiation exposure. Therefore, radiation protection authorities have become strict regarding the control of radiation risks.¦There are various situations where the radiation risk needs to be evaluated. International authority bodies point to the increasing number of radiologic procedures and recommend population surveys. These surveys provide valuable data to public health authorities which helps them to prioritize and focus on patient groups in the population that are most highly exposed. On the other hand, physicians need to be aware of radiation risks from diagnostic procedures in order to justify and optimize the procedure and inform the patient.¦The aim of this work was to examine the different aspects of radiation protection and investigate a new method to estimate patient radiation risks.¦The first part of this work concerned radiation risk assessment from the regulatory authority point of view. To do so, a population dose survey was performed to evaluate the annual population exposure. This survey determined the contribution of different imaging modalities to the total collective dose as well as the annual effective dose per caput. It was revealed that although interventional procedures are not so frequent, they significantly contribute to the collective dose. Among the main results of this work, it was shown that interventional cardiological procedures are dose-intensive and therefore more attention should be paid to optimize the exposure.¦The second part of the project was related to the patient and physician oriented risk assessment. In this part, interventional cardiology procedures were studied by means of Monte Carlo simulations. The organ radiation doses as well as effective doses were estimated. Cancer incidence risks for different organs were calculated for different sex and age-at-exposure using the lifetime attributable risks provided by the Biological Effects of Ionizing Radiations Report VII. Advantages and disadvantages of the latter results were examined as an alternative method to estimate radiation risks. The results show that this method is the most accurate, currently available, to estimate radiation risks. The conclusions of this work may guide future studies in the field of radiation protection in medicine.¦-¦Depuis la découverte des rayons X en 1895, ce type de rayonnement a joué un rôle important dans de nombreux domaines. Son utilisation en médecine a bénéficié à la population mondiale puisque l'avantage d'un examen diagnostique est de réduire les incertitudes sur l'état de santé du patient. Cependant, leur utilisation peut conduire à l'apparition de cancers radio-induits. Par conséquent, les autorités sanitaires sont strictes quant au contrôle du risque radiologique.¦Le risque lié aux radiations doit être estimé dans différentes situations pratiques, dont l'utilisation médicale des rayons X. Les autorités internationales de radioprotection indiquent que le nombre d'examens et de procédures radiologiques augmente et elles recommandent des enquêtes visant à déterminer les doses de radiation délivrées à la population. Ces enquêtes assurent que les groupes de patients les plus à risque soient prioritaires. D'un autre côté, les médecins ont également besoin de connaître le risque lié aux radiations afin de justifier et optimiser les procédures et informer les patients.¦Le présent travail a pour objectif d'examiner les différents aspects de la radioprotection et de proposer une manière efficace pour estimer le risque radiologique au patient.¦Premièrement, le risque a été évalué du point de vue des autorités sanitaires. Une enquête nationale a été réalisée pour déterminer la contribution des différentes modalités radiologiques et des divers types d'examens à la dose efficace collective due à l'application médicale des rayons X. Bien que les procédures interventionnelles soient rares, elles contribuent de façon significative à la dose délivrée à la population. Parmi les principaux résultats de ce travail, il a été montré que les procédures de cardiologie interventionnelle délivrent des doses élevées et devraient donc être optimisées en priorité.¦La seconde approche concerne l'évaluation du risque du point de vue du patient et du médecin. Dans cette partie, des procédures interventionnelles cardiaques ont été étudiées au moyen de simulations Monte Carlo. La dose délivrée aux organes ainsi que la dose efficace ont été estimées. Les risques de développer des cancers dans plusieurs organes ont été calculés en fonction du sexe et de l'âge en utilisant la méthode établie dans Biological Effects of Ionizing Radiations Report VII. Les avantages et inconvénients de cette nouvelle technique ont été examinés et comparés à ceux de la dose efficace. Les résultats ont montré que cette méthode est la plus précise actuellement disponible pour estimer le risque lié aux radiations. Les conclusions de ce travail pourront guider de futures études dans le domaine de la radioprotection en médicine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

At the Lausanne University, 5th year medical students were trained in Motivational interviewing (MI). Eight hours of training improved their competence in the use of this approach. This experience supports the implementation of MI training in medical schools. Motivational interviewing allows the health professional to actively involve the patient in this behavior change process (drinking, smoking, diet, exercise, medication adherence, etc.), by encouraging reflection and reinforcing personal motivation and resources.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

L’observance, qui décrit à quel degré le patient suit la prescription, est un facteur essentiel pour que le traitement réussisse. Les observances des patients varient beaucoup et l’efficacité du médicament varie parallèlement. Par conséquent, il faut avoir des paramètres sensibles et fiables pour mesurer l’observance. Dans la littérature, on trouve beaucoup de paramètres pour évaluer l’observance mais leurs avantages, limites et inconvénients, en ce qui concerne l’évaluation de l’impact de l’observance sur les effets des médicaments n’ont pas encore été étudiés en profondeur. L’évaluation de ces paramètres nécessite de les tester dans différentes situations. Comme les données disponibles sur l’observance ne concernent pas un ensemble exhaustif de situations, le recours à la simulation, en s’inspirant des cas réels ou plausibles, est très pertinent. On a ainsi réussi à développer un modèle dont les paramètres sont simples et compréhensibles et qui est pratique et flexible pour simuler les différents cas et même les cas extrêmes de l’observance. On a proposé de nouveaux paramètres pour mesurer l’impact biopharmaceutique de l’observance. Ensuite, on a comparé la performance, en termes de sensibilité et la fiabilité, des paramètres proposés et celles de paramètres déjà utilisés. En conclusion, on peut souligner qu’il n’y a pas de paramètre parfait étant donné que chacun a ses propres limites. Par exemple, pour les médicaments dont les effets sont directement liés aux leurs concentrations plasmatiques, le pourcentage des doses prises, qui est le paramètre le plus utilisé, offre la pire performance; par contre, le pourcentage des doses correctes nettes qui est un nouveau paramètre possède une bonne performance et des avantages prometteurs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

With an increasing number of institutions offering proton therapy, the number of multi-institutional clinical trials involving proton therapy will also increase in the coming years. The Radiological Physics Center monitors sites involved in clinical trials through the use of site visits and remote auditing with thermoluminescent dosimeters (TLD) and mailable anthropomorphic phantoms. Currently, there are no heterogeneous phantoms that have been commissioned to evaluate proton therapy. It was hypothesized that an anthropomorphic pelvis phantom can be designed to audit treatment procedures (patient simulation, treatment planning and treatment delivery) at proton facilities to confirm agreement between the measured dose and calculated dose within 5%/3mm with a reproducibility of 3%. A pelvis phantom originally designed for use with photon treatments was retrofitted for use in proton therapy. The relative stopping power (SP) of each phantom material was measured. Hounsfield Units (HU) for each phantom material were measured with a CT scanner and compared to the relative stopping power calibration curve. The tissue equivalency for each material was calculated. Two proton treatment plans were created; one which did not correct for material SP differences (Plan 1) and one plan which did correct for SP differences (Plan 2). Film and TLD were loaded into the phantom and the phantom was irradiated 3 times per plan. The measured values were compared to the HU-SP calibration curve and it was found that the stopping powers for the materials could be underestimated by 5-10%. Plan 1 passed the criteria for the TLD and film margins with reproducibility under 3% between the 3 trials. Plan 2 failed because the right-left film dose profile average displacement was -9.0 mm on the left side and 6.0 mm on the right side. Plan 2 was intended to improve the agreements and instead introduced large displacements along the path of the beam. Plan 2 more closely represented the actual phantom composition with corrected stopping powers and should have shown an agreement between the measured and calculated dose within 5%/3mm. The hypothesis was rejected and the pelvis phantom was found to be not suitable to evaluate proton therapy treatment procedures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Radiological Physics Center (RPC) provides heterogeneous phantoms that are used to evaluate radiation treatment procedures as part of a comprehensive quality assurance program for institutions participating in clinical trials. It was hypothesized that the existing RPC heterogeneous thorax phantom can be modified to assess lung tumor proton beam therapy procedures involving patient simulation, treatment planning, and treatment delivery, and could confirm agreement between the measured dose and calculated dose within 5%/3mm with a reproducibility of 5%. The Hounsfield Units (HU) for lung equivalent materials (balsa wood and cork) was measured using a CT scanner. The relative linear stopping power (RLSP) of these materials was measured. The linear energy transfer (LET) of Gafchromic EBT2 film was analyzed utilizing parallel and perpendicular orientations in a water tank and compared to ion chamber readings. Both parallel and perpendicular orientations displayed a quenching effect underperforming the ion chamber, with the parallel orientation showing an average 31 % difference and the perpendicular showing an average of 15% difference. Two treatment plans were created that delivered the prescribed dose to the target volume, while achieving low entrance doses. Both treatment plans were designed using smeared compensators and expanded apertures, as would be utilized for a patient in the clinic. Plan 1a contained two beams that were set to orthogonal angles and a zero degree couch kick. Plan 1b utilized two beams set to 10 and 80 degrees with a 15 degree couch kick. EBT2 film and TLD were inserted and the phantom was irradiated 3 times for each plan. Both plans passed the criteria for the TLD measurements where the TLD values were within 7% of the dose calculated by Eclipse. Utilizing the 5%/3mm criteria, the 3 trial average of overall pass rate was 71% for Plan 1a. The 3 trial average for the overall pass rate was 76% for Plan 1b. The trials were then analyzed using RPC conventional lung treatment guidelines set forth by the RTOG: 5%/5mm, and an overall pass rate of 85%. Utilizing these criteria, only Plan 1b passed for all 3 trials, with an average overall pass rate of 89%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O ensino dos processos de julgamento clínico e de raciocínio diagnóstico para estudantes de enfermagem torna-se cada vez mais importante para a qualificação dos cursos de graduação em enfermagem e alcance do compromisso com a formação clínica por excelência do enfermeiro, em uma realidade de saúde cada vez mais complexa. Os objetivos deste estudo foram identificar o julgamento clínico e o raciocínio diagnóstico de estudantes de enfermagem, correlacionar estes dois processos e identificar diferenças entre estudantes da fase intermediária e os concluintes do curso, de uma Escola do interior paulista. Para avaliar o julgamento clínico, construímos um cenário de simulação clínica de alta-fidelidade, representando uma paciente com anemia falciforme em crise de dor e, ainda, traduzimos e adaptamos à cultura brasileira o instrumento Lasater Clinical Judgment Rubric (LASATER, 2007); para avaliar o raciocínio diagnóstico, utilizamos o instrumento já adaptado por Rodrigues (2012) denominado de Inventário de Raciocínio Diagnóstico (BORDAGE; GRANT; MARSDEN, 1990). Os resultados demonstraram que os estudantes de enfermagem apresentaram, predominantemente, nível Proficiente na maioria das dimensões de julgamento clínico (66,7% dos estudantes do grupo concluinte e 56,5% dos estudantes do grupo intermediário). Já para o raciocínio diagnóstico, a maioria dos estudantes foi considerada com ampla habilidade para realizar diagnósticos de enfermagem (91,3% dos estudantes do grupo intermediário e 83,4% dos estudantes do grupo concluinte). Destaca-se que dos concluintes 11,1% apresentaram habilidade máxima. Os estudantes do último ano de graduação em enfermagem apresentaram desempenho superior na fase de interpretação do julgamento clínico (p=0,021). Não se observou diferença entre os grupos para o raciocínio diagnóstico (p=0,334). Houve moderada correlação entre julgamento clínico e raciocínio diagnóstico; e ainda, a fase de reconhecimento do julgamento clínico apresentou-se moderadamente correlacionada ao processo de raciocínio diagnóstico. Considerando que o raciocínio diagnóstico está presente no processo de julgamento clínico, principalmente no momento da investigação do caso clínico (fase Reconhecimento do julgamento clínico) e que as habilidades de raciocinio diagnóstico se manifestam predominantemente nesta fase, a compreensão e o desenvolvimento destes processos pelos estudantes devem ser valorizados nos currículos de graduação em enfermagem

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We developed a general model to assess patient activity within the primary and secondary health-care sectors following a dermatology outpatient consultation. Based on observed variables from the UK teledermatology trial, the model showed that up to 11 doctor-patient interactions occurred before a patient was ultimately discharged from care. In a cohort of 1000 patients, the average number of health-care visits was 2.4 (range 1-11). Simulation analysis suggested that the most important parameter affecting the total number of doctor-patient Interactions is patient discharge from care following the initial consultation. This implies that resources should be concentrated in this area. The introduction of teledermatology (either realtime or store and forward) changes the values of the model parameters. The model provides a quantitative tool for planning the future provision of dermatology health-care.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction: Streptomycin, as other aminoglycosides, exhibits concentration-dependent bacterial killing but has a narrow therapeutic window. It is primarily eliminated unchanged by the kidneys. Data and dosing information to achieve a safe regimen in patients with chronic renal failure undergoing hemodialysis (HD) are scarce. Although main adverse reactions are related to prolonged, elevated serum concentrations, literature recommendation is to administer streptomycin after each HD. Patients (or Materials) and Methods: We report the case of a patient with end-stage renal failure, undergoing HD, who was successfully treated with streptomycin for gentamicin-resistant Enterococcus faecalis bacteremia with prosthetic arteriovenous fistula infection. Streptomycin was administered intravenously 7.5 mg/kg, 3 hours before each dialysis (3 times a week) during 6 weeks in combination with amoxicillin. Streptomycin plasma levels were monitored with repeated blood sampling before, after, and between HD sessions. A 2-compartment model was used to reconstruct the concentration time profile over days on and off HD. Results: Streptomycin trough plasma-concentration was 2.8 mg/L. It peaked to 21.4 mg/L 30 minutes after intravenous administration, decreased to 18.2 mg/L immediately before HD, and dropped to 4.5 mg/L at the end of a 4-hour HD session. Plasma level increased again to 5.7 mg/L 2 hours after the end of HD and was 2.8 mg/L 48 hours later, before the next administration and HD. The pharmacokinetics of streptomycin was best described with a 2-compartment model. The computer simulation fitted fairly well to the observed concentrations during or between HD sessions. Redistribution between the 2 compartments after the end of HD reproduced the rebound of plasma concentrations after HD. No significant toxicity was observed during treatment. The outcome of the infection was favorable, and no sign of relapse was observed after a follow-up of 3 months. Conclusion: Streptomycin administration of 7.5 mg/kg 3 hours before HD sessions in a patient with end-stage renal failure resulted in an effective and safe dosing regimen. Monitoring plasma levels along with pharmacokinetic simulation document the suitability of this dosing scheme, which should replace current dosage recommendations for streptomycin in HD.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Modeling of tumor growth has been performed according to various approaches addressing different biocomplexity levels and spatiotemporal scales. Mathematical treatments range from partial differential equation based diffusion models to rule-based cellular level simulators, aiming at both improving our quantitative understanding of the underlying biological processes and, in the mid- and long term, constructing reliable multi-scale predictive platforms to support patient-individualized treatment planning and optimization. The aim of this paper is to establish a multi-scale and multi-physics approach to tumor modeling taking into account both the cellular and the macroscopic mechanical level. Therefore, an already developed biomodel of clinical tumor growth and response to treatment is self-consistently coupled with a biomechanical model. Results are presented for the free growth case of the imageable component of an initially point-like glioblastoma multiforme tumor. The composite model leads to significant tumor shape corrections that are achieved through the utilization of environmental pressure information and the application of biomechanical principles. Using the ratio of smallest to largest moment of inertia of the tumor material to quantify the effect of our coupled approach, we have found a tumor shape correction of 20\% by coupling biomechanics to the cellular simulator as compared to a cellular simulation without preferred growth directions. We conclude that the integration of the two models provides additional morphological insight into realistic tumor growth behavior. Therefore, it might be used for the development of an advanced oncosimulator focusing on tumor types for which morphology plays an important role in surgical and/or radio-therapeutic treatment planning.