991 resultados para Patient positioning


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Whole-body computed tomography (WBCT) plays an important role in the management of severely injured patients. We evaluated the radiation exposure of WBCT scans using different positioning boards and arm positions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To facilitate the implementation of evidence-based skin and pressure ulcer (PU) care practices and related staff education programs in a university hospital in Brazil, a cross-sectional study was conducted to evaluate nurses` knowledge about PU prevention, wound assessment, and staging. Of the 141 baccalaureate nurses (BSN) employed by the hospital at the time of the study, 106 consented to participate. Using a Portuguese version of Pieper`s Pressure Ulcer Knowledge Test (PUKT), participants were asked to indicate whether 33 statements about PU prevention and eight about PU assessment and staging were true or false. For the 33 prevention statements, the average number answered correctly was 26.07 (SD 4.93) and for the eight assessment statements the average was 4.59 (SD 1.62). Nurses working on inpatient clinical nursing units had significantly better scores (P = 0.000). Years of nursing experience had a weak and negative correlation with correct PUKT scores (r = -0.21, P = 0.033) as did years of experience working in the university hospital (r = -.179, P <071). Incorrect responses were most common for statements related to patient positioning, massage, PU assessment, and staging definitions. The results of this study confirm that nurses have an overall understanding of PU prevention and assessment principles but important knowledge deficits exist. Focused continuing education efforts are needed to facilitate the implementation of evidence-based care.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Retention of airway secretions is a common and serious problem in ventilated patients. Treating or avoiding secretion retention with mucus thinning, patient-positioning, airway suctioning, or chest or airway vibration or percussion may provide short-term benefit. METHODS: In a series of laboratory experiments with a test-lung system we examined the role of ventilator settings and lung-impedance on secretion retention and expulsion. Known quantities of a synthetic dye-stained mucus simulant with clinically relevant properties were injected into a transparent tube the diameter of an adult trachea and exposed to various mechanical-ventilation conditions. Mucus-simulant movement was measured with a photodensitometric technique and examined with image-analysis software. We tested 2 mucus-simulant viscosities and various peak flows, inspiratory/ expiratory flow ratios, intrinsic positive end-expiratory pressures, ventilation waveforms, and impedance values. RESULTS: Ventilator settings that produced flow bias had a major effect on mucus movement. Expiratory How bias associated with intrinsic positive end-expiratory pressure generated by elevated minute ventilation moved mucus toward the airway opening, whereas intrinsic positive end-expiratory pressure generated by increased airway resistance moved the mucus toward the lungs. Inter-lung transfer of mucus simulant occurred rapidly across the ""carinal divider"" between interconnected test lungs set to radically different compliances; the mucus moved out of the low-compliance lung and into the high-compliance lung. CONCLUSIONS: The movement of mucus simulant was influenced by the ventilation pattern and lung impedance. Flow bias obtained with ventilator settings may clear or embed mucus during mechanical ventilation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introdução – Numa era em que os tratamentos de Radioterapia Externa (RTE) exigem cada vez mais precisão, a utilização de imagem médica permitirá medir, quantificar e avaliar o impacto do erro provocado pela execução do tratamento ou pelos movimentos dos órgãos. Objetivo – Analisar os dados existentes na literatura acerca de desvios de posicionamento (DP) em patologias de cabeça e pescoço (CP) e próstata, medidos com Cone Beam Computed Tomography (CBCT) ou Electronic Portal Image Device (EPID). Metodologia – Para esta revisão da literatura foram pesquisados artigos recorrendo às bases de dados MEDLINE/PubMed e b-on. Foram incluídos artigos que reportassem DP em patologias CP e próstata medidos através de CBCT e EPID. Seguidamente foram aplicados critérios de validação, que permitiram a seleção dos estudos. Resultados – Após a análise de 35 artigos foram incluídos 13 estudos e validados 9 estudos. Para tumores CP, a média (μ) dos DP encontra-se entre 0,0 e 1,2mm, com um desvio padrão (σ) máximo de 1,3mm. Para patologias de próstata observa-se μDP compreendido entre 0,0 e 7,1mm, com σ máximo de 7,5mm. Discussão/Conclusão – Os DP em patologias CP são atribuídos, maioritariamente, aos efeitos secundários da RTE, como mucosite e dor, que afetam a deglutição e conduzem ao emagrecimento, contribuindo para a instabilidade da posição do doente durante o tratamento, aumentando as incertezas de posicionamento. Os movimentos da próstata devem-se principalmente às variações de preenchimento vesical, retal e gás intestinal. O desconhecimento dos DP afeta negativamente a precisão da RTE. É importante detetá-los e quantificá-los para calcular margens adequadas e a magnitude dos erros, aumentando a precisão da administração de RTE, incluindo o aumento da segurança do doente. - ABSTRACT - Background and Purpose – In an era where precision is an increasing necessity in external radiotherapy (RT), modern medical imaging techniques provide means for measuring, quantifying and evaluating the impact of treatment execution and movement error. The aim of this paper is to review the current literature on the quantification of setup deviations (SD) in patients with head and neck (H&N) or prostate tumors, using Cone Beam Computed Tomography (CBCT) or Electronic Portal Image Device (EPID). Methods – According to the study protocol, MEDLINE/PubMed and b-on databases were searched for trials, which were analyzed using selection criteria based on the quality of the articles. Results – After assessment of 35 papers, 13 studies were included in this analysis and nine were authenticated (6 for prostate and 3 for H&N tumors). The SD in the treatment of H&N cancer patients is in the interval of 0.1 to 1.2mm, whereas in prostate cancer this interval is 0.0 to 7.1mm. Discussion – The reproducibility of patient positioning is the biggest barrier for higher precision in RT, which is affected by geometrical uncertainty, positioning errors and inter or intra-fraction organ movement. There are random and systematic errors associated to patient positioning, introduced since the treatment planning phase or through physiological organ movement. Conclusion – The H&N SD are mostly assigned to the Radiotherapy adverse effects, like mucositis and pain, which affect swallowing and decrease secretions, contributing for the instability of patient positioning during RT treatment and increasing positioning uncertainties. Prostate motion is mainly related to the variation in bladder and rectal filling. Ignoring SD affects negatively the accuracy of RT. Therefore, detection and quantification of SD is crucial in order to calculate appropriate margins, the magnitude of error and to improve accuracy in RTE and patient safety.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Developmental Dysplasia of the Hip (DDH), also know as Congenital Dislocation of the Hip, is common in infants and children and may persist into adulthood. The radiographic interpretation is highly conditioned by appropriate patient positioning and image quality criteria. The main goal of this study is to demonstrate the value of radiographic evaluation of DDH. Through the retrospective analysis of 65 radiographs of the hips, only 2 (3.1%) female patients with 1-2 years of age presented radiographic findings of DDH. The inappropriate field size and the improper placement and size of the gonadal shields, were the most common errors observed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Terapia com Radiações

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: The suprascapular nerve (SSN) block is frequently performed for different shoulder pain conditions and for perioperative and postoperative pain control after shoulder surgery. Blind and image-guided techniques have been described, all of which target the nerve within the supraspinous fossa or at the suprascapular notch. This classic target point is not always ideal when ultrasound (US) is used because it is located deep under the muscles, and hence the nerve is not always visible. Blocking the nerve in the supraclavicular region, where it passes underneath the omohyoid muscle, could be an attractive alternative. METHODS: In the first step, 60 volunteers were scanned with US, both in the supraclavicular and the classic target area. The visibility of the SSN in both regions was compared. In the second step, 20 needles were placed into or immediately next to the SSN in the supraclavicular region of 10 cadavers. The accuracy of needle placement was determined by injection of dye and following dissection. RESULTS: In the supraclavicular region of volunteers, the nerve was identified in 81% of examinations (95% confidence interval [CI], 74%-88%) and located at a median depth of 8 mm (interquartile range, 6-9 mm). Near the suprascapular notch (supraspinous fossa), the nerve was unambiguously identified in 36% of examinations (95% CI, 28%-44%) (P < 0.001) and located at a median depth of 35 mm (interquartile range, 31-38 mm; P < 0.001). In the cadaver investigation, the rate of correct needle placement of the supraclavicular approach was 95% (95% CI, 86%-100%). CONCLUSIONS: Visualization of the SSN with US is better in the supraclavicular region as compared with the supraspinous fossa. The anatomic dissections confirmed that our novel supraclavicular SSN block technique is accurate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: To compare morphological gross tumor volumes (GTVs), defined as pre- and postoperative gadolinium enhancement on T1-weighted magnetic resonance imaging to biological tumor volumes (BTVs), defined by the uptake of (18)F fluoroethyltyrosine (FET) for the radiotherapy planning of high-grade glioma, using a dedicated positron emission tomography (PET)-CT scanner equipped with three triangulation lasers for patient positioning. METHODS: Nineteen patients with malignant glioma were included into a prospective protocol using FET PET-CT for radiotherapy planning. To be eligible, patients had to present with residual disease after surgery. Planning was performed using the clinical target volume (CTV = GTV union or logical sum BTV) and planning target volume (PTV = CTV + 20 mm). First, the interrater reliability for BTV delineation was assessed among three observers. Second, the BTV and GTV were quantified and compared. Finally, the geometrical relationships between GTV and BTV were assessed. RESULTS: Interrater agreement for BTV delineation was excellent (intraclass correlation coefficient 0.9). Although, BTVs and GTVs were not significantly different (p = 0.9), CTVs (mean 57.8 +/- 30.4 cm(3)) were significantly larger than BTVs (mean 42.1 +/- 24.4 cm(3); p < 0.01) or GTVs (mean 38.7 +/- 25.7 cm(3); p < 0.01). In 13 (68%) and 6 (32%) of 19 patients, FET uptake extended >or= 10 and 20 mm from the margin of the gadolinium enhancement. CONCLUSION: Using FET, the interrater reliability had excellent agreement for BTV delineation. With FET PET-CT planning, the size and geometrical location of GTVs and BTVs differed in a majority of patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The authors present the four-arm single docking full robotic surgery to treat low rectal cancer. The eight main operative steps are: 1- patient positioning; 2- trocars set-up and robot docking; 3- sigmoid colon, left colon and splenic flexure mobilization (lateral-to-medial approach); 4-Inferior mesenteric artery and vein ligation (medial-to-lateral approach); 5- total mesorectum excision and preservation of hypogastric and pelvic autonomic nerves (sacral dissection, lateral dissection, pelvic dissection); 6- division of the rectum using an endo roticulator stapler for the laparoscopic performance of a double-stapled coloanal anastomosis (type I tumor); 7- intersphincteric resection, extraction of the specimen through the anus and lateral-to-end hand sewn coloanal anastomosis (type II tumor); 8- cylindric abdominoperineal resection, with transabdominal section of the levator muscles (type IV tumor). The techniques employed were safe and have presented low rates of complication and no mortality.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tutkielman tarkoituksena oli kuvata potilaan kokemuksia tiedollisesta yksityisyydestään sekä tiedollista yksityisyyttä edistäviä ja estäviä tekijöitä heräämössä. Tämän tiedon pohjalta on mahdollista kehittää heräämön hoitotyötä potilaiden tiedollisen yksityisyyden osalta. Tutkimus toteutettiin kuvailevana haastattelututkimuksena. Aineisto kerättiin puolistrukturoidun teemahaastattelun avulla. Tutkimuksessa haastateltiin yhden suomalaisen yliopistosairaalan korva-, nenä- ja kurkkutautien (KNK) klinikan heräämössä hoidettuja aikuispotilaita 1-2 tunnin kuluessa heräämöhoidon päättymisestä. Haastatteluaineisto koostui 17:stä päiväkirurgisen – tai vuodeosastopotilaan haastattelusta. Tallennetut haastattelut litteroitiin ja aineisto analysoitiin induktiivisella sisällönanalyysillä. Potilaat kuvasivat tiedollista yksityisyyttä potilaan tietojen hallintana: potilaan tietojen luottamuksellisena käsittelynä ja oikeutena omiin tietoihin. Tiedollista yksityisyyttä pidettiin tärkeänä, mutta potilaat eivät olleet erityisen huolissaan tämän toteutumisesta heräämössä. Tiedollinen yksityisyys toteutui potilaiden mielestä melko hyvin heräämössä lukuun ottamatta tilanteita, joissa henkilökunta vaihtoi suullisesti tietoja potilaasta keskenään. Suurin osa potilaista totesi KNK-vaivojen olevan niin neutraaleja, ettei niiden joutuminen ulkopuolisten tietoon ollut heistä merkityksellistä. Tieto leikkauksesta kiinnosti potilaita ja he olivat tyytyväisiä saatuaan siitä tietoa heräämössä. Tiedollisen yksityisyyden toteutumista edistivät potilaan uppoutuminen omaan maailmaansa, mahdollisuus kontrolloida ja saada tietoa asioistaan, kahdenkeskinen vuorovaikutus, tieto tiedollisesta yksityisyydestä, heräämön tilajärjestelyt ja tiedollista yksityisyyttä koskevien sääntöjen noudattaminen. Muiden potilaiden uteliaisuus, potilaan kyvyttömyys suojata omia tietojaan ja ulkopuolisuus omissa asioissaan, kahdenkeskeisen vuorovaikutuksen mahdottomuus, yksityisen tilan puute ja tiedollista yksityisyyttä koskevan sääntelyn noudattamattomuus koettiin tietojen luottamuksellisen käsittelyn esteiksi heräämössä. Potilaiden tietojen luottamuksellista käsittelyä voitaisiin parantaa kiinnittämällä huomiota raportointimenetelmiin ja -paikkaan heräämössä. Käytettävissä olevia keinoja, kuten sermejä ja potilaiden sijoittelu heräämössä, kannattaa käyttää hyödyksi potilaan tiedollisen yksityisyyden suojaamiseksi. Tiedollisen yksityisyyden määritelmää tulisi jatkossa täsmentää käsiteanalyysin avulla. Lisäksi tiedollista yksityisyyttä olisi hyvä tutkia hoitotyön ympäristöissä, joissa potilaiden hoitoon liittyy mahdollisesti arkaluonteisempia tietoja kuin KNK- potilailla.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

L'un des principaux défis de l'interprétation radiographique réside dans la compréhension de l’anatomie radiographique, laquelle est intrinsèquement liée à la disposition tridimensionnelle des structures anatomiques et à l’impact du positionnement du tube radiogène vis-à-vis de ces structures lors de l'acquisition de l'image. Traditionnellement, des radiographies obtenues selon des projections standard sont employées pour enseigner l'anatomie radiographique en médecine vétérinaire. La tomodensitométrie − ou communément appelée CT (Computed Tomography) − partage plusieurs des caractéristiques de la radiographie en ce qui a trait à la génération des images. À l’aide d'un plug-in spécialement développé (ORS Visual ©), la matrice contenant les images CT est déformée pour reproduire les effets géométriques propres au positionnement du tube et du détecteur vis-à-vis du patient radiographié, tout particulièrement les effets de magnification et de distorsion. Afin d'évaluer le rendu des images simulées, différentes régions corporelles ont été imagées au CT chez deux chiens, un chat et un cheval, avant d'être radiographiées suivant des protocoles d'examens standards. Pour valider le potentiel éducatif des simulations, dix radiologistes certifiés ont comparé à l'aveugle neuf séries d'images radiographiques simulées aux séries radiographiques standard. Plusieurs critères ont été évalués, soient le grade de visualisation des marqueurs anatomiques, le réalisme et la qualité radiographique des images, le positionnement du patient et le potentiel éducatif de celles-ci pour différents niveaux de formation vétérinaire. Les résultats généraux indiquent que les images radiographiques simulées à partir de ce modèle sont suffisamment représentatives de la réalité pour être employées dans l’enseignement de l’anatomie radiographique en médecine vétérinaire.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Especificar e quantificar as principais falhas técnicas, sejam elas eletrônicas ou mecânicas, presentes em radiografias convencionais de tórax, com o intuito de melhorar a sua qualidade e reduzir a necessidade da repetição dos exames e, consequentemente, a dose recebida pelo paciente. MATERIAIS E MÉTODOS: Foram selecionadas e avaliadas por um pneumologista 897 radiografias convencionais realizadas ou em projeção posteroanterior ou lateral em cinco instituições de saúde da cidade de São Paulo. em cada uma delas foram feitas análises das falhas técnicas presentes, as quais foram classificadas de acordo com o erro técnico radiográfico pré-definido e que levou à repetição do exame. RESULTADOS: Os resultados obtidos mostraram que o posicionamento incorreto do paciente (27%), a subexposição (23%) e a superexposição (15%) foram as principais falhas que contribuíram para a repetição dos exames e que apresentaram, na matriz de coeficiente de correlação Pearson, um erro acima de 0,7%, ocasionando aumento da dose recebida pelos pacientes. CONCLUSÃO: Os resultados observados indicaram a necessidade da realização de controle de qualidade dos aparelhos de raios X, a atenção do operador do equipamento, bem como outras abordagens para esclarecer o impacto da necessidade de repetição do exame.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: the purpose of this study was to determine the effects of prone positioning on cardiorespiratory stability and weaning outcome of preterm infants during weaning from mechanical ventilation. Methods: from January to December 1999, a sample of 42 preterm infants, with birthweight < 2,000 g, mechanically ventilated in the first week of life, were randomly divided, in the beginning of the weaning process, in two groups according to the position: supine position (n = 21) or prone position (n = 21). Heart rate, respiratory rate, transcutaneous oxygen saturation and ventilatory parameters were recorded every one hour. Length of the weaning process and complications were also assessed. Results: in both groups the mean gestational age was 29 weeks, most of the patients presented very low birthweight and respiratory distress syndrome. The mean length of the weaning process was 2 days. There were no differences between the groups regarding respiratory rate, heart rate and transcutaneous oxygen saturation, however, oxygen desaturation episodes were more frequent in supine position (p = 0.009). Ventilatory parameters decreased faster and reintubation was less frequent in the prone group (4% versus 33%). No adverse effects of prone positioning were observed. Conclusion: these results suggest that prone position is a safe and beneficial procedure during the weaning from mechanical ventilation and may contribute to weaning success in preterm infants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The dentist has been suggested as a professional vulnerable to labor risks mainly related to working posture. This study examined the application of ergonomics principles during the dental attendances made by university student of the last period of the Araçatuba Dental University. Twenty-four attendants were photographed and the images were digitally analyzed for the verification of 10 requirements that determine a healthy labor posture, defined by the project ISO Standard / TC 106/SC 6 N 411. It was observed that 50% of items from the check list obtained higher percentages of negative replies. The students had greater difficulties as to the correct position of the angle between the upper and lower leg when sitting, the ideal adjustment of the light focus reflector in the field of work and the patient positioning. It was concluded that the dental attendances were held without compliance with the ergonomic requirements. The greatest difficulties regarding the work posture were the sitting posture, the light beam and the patient positioning. Students need better guidance about ergonomic principles and requirements, which should occur at any time of life, but earliest they are installed, greater the benefits, assimilation and incorporation of adequate working postures will be. We need a reform that addresses all sectors of the dental system, so that learning and application of ergonomics in dentistry become effective, efficient and effective.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hintergrund: Die Systembiopsie gilt als Goldstandard zum Nachweis eines Prostatakarzinoms, obwohl ein relevanter Anteil an Prostatakarzinomen nicht diagnostiziert wird. Wir wollten mit unserer Arbeit die Frage beantworten, ob mittels elastographisch gezielter Biopsien die Prostatakarzinom-Detektion im Vergleich zur Goldstandard-Systembiopsie verbessert werden kann. Material und Methode: 152 Patienten wurden in einer prospektiven Studie einer 12-fachen Prostata-Systembiopsie unterzogen. In Linksseitenlagerung wurde dabei aus jedem der vordefinierten 6 Prostatasegmente je 1 laterale und 1 mediale Stanze entnommen. Elastographisch suspekte Areale wurden zusätzlich gezielt biopsiert. Als statistisch signifikant wurde p<0,05 angenommen. Ergebnisse: Bei 62 der 152 Patienten (40,8%) wurde ein Prostatakarzinom diagnostiziert. Die Detektionsrate der Systembiopsie betrug 39,5% (60/152), die Detektionsrate der Elastographie 29,6% (45/152). Somit war die Systembiopsie der elastographisch gezielten Biopsie signifikant überlegen (p=0,039).Jedoch war die Wahrscheinlichkeit mit einer Prostatastanze ein Karzinomherd zu entdecken, für die elastographischen Biopsien 3,7-fach höher als für die Systembiopsien. Die Sensitivität der Elastographie betrug 72,6% und die Spezifität 66,6%. Der positive Vorhersagewert für die Elastographie war 60%, der negative Vorhersagewert 78%. Die Kombination von Systembiopsie und elastographisch gezielten Biopsien bot die höchste Detektionsrate. In der rechten Prostatahälfte (48%) verzeichneten wir doppelt so viele elastographisch falsch-positive Befunde wie in der linken Prostatahälfte (25%). Desweiteren fanden sich am häufigsten falsch-positive Befunde im Prostata-Apex (46%) und am seltensten in der Prostata-Basis (29%). Schlussfolgerung: In unserer Studie war die elastographisch gezielte Biopsie der Systembiopsie signifikant unterlegen (p=0,039). Die Kombination von Systembiopsie mit elastographisch gezielten Biopsien bot die höchste Detektionsrate und kann daher empfohlen werden. Die Auffälligkeiten in der Segment-bezogenen Auswertung und ein möglicher Einfluss der Patienten-Lagerung müssen durch weitere Studien überprüft werden.rn