178 resultados para Patellar resurfacing
Resumo:
Total knee replacement (TKR) is an operation that has radically improved the quality of life of millions of people during the last decades. However, some technical details, concerning the surgical procedure, are still a matter of a strong debate. In this review of the literature, we have included the best evidence available of the last decade, related to TKR surgery like the use of tourniquet during operation, patellar resufacing, all-polyethilene tibial component, cemented or cementless fixation, mobile bearings, or posterior-stabilized versus cruciate-retaining prosthesis.
Resumo:
In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.
Resumo:
Purpose: To evaluate patellar kinematics of volunteers Without knee pain at rest and during isometric contraction in open- and closed-kinetic-chain exercises. Methods: Twenty individuals took part in this study. All were submitted to magnetic resonance imaging (MRI) during rest and voluntary isometric contraction (VIC) in the open anti closed kinetic chain at 15 degrees, 30 degrees, and 45 degrees of knee flexion. Through MRI and using medical e-film software, the following measurements were evaluated: sulcus angle, patellar-tilt angle, and bisect offset. The mixed-effects linear model was used for comparison between knee positions, between rest and isometric contractions, and between (he exercises. Results: Data analysis revealed that the sulcus angle decreased as knee flexion increased and revealed increases with isometric contractions in both the open and closed kinetic chain for all knee-flexion angles. The patellar-tilt angle decreased with isometric contractions in both the open and closed kinetic chain for every knee position. However, in the closed kinetic chain, patellar tilt increased significantly with the knee flexed at 15 degrees. The bisect offset increased with the knee flexed at 15 degrees during isometric contractions and decreased as knee flexion increased during both exercises. Conclusion: VIC in the last degrees of knee extension may compromise patellar dynamics. On the other hand, it is possible to favor patellar stability by performing muscle contractions with the knee flexed at 30 degrees and 45 degrees in either the open or closed kinetic chain.
Resumo:
The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Patella stabilizer muscle response and patellar kinematics were evaluated in 19 women with anterior knee pain (AKP) and 20 healthy women during maximum voluntary isometric contraction (MVIC) with the knee positioned at 15 degrees, 30 degrees and 45 degrees flexion during open (OKC) and closed (CKC) kinetic chain exercises. Patellar kinematics was evaluated through patellar tilt and displacement, and the electrical activity of patellar stabilizers through the root mean square normalized during MVIC and OKC with the knee at 90 degrees flexion. Data revealed that the vastus medialis oblique muscle (VMO) was more active in the control group compared to the AKP group during OKC exercises with the knee at 45 degrees flexion. However, no difference in the patellar kinematics was observed between these groups; nevertheless, the correlation between these parameters also showed, with the knee at 45 degrees flexion, that lateral patellar tilt increase was associated with a reduction in the activity of lateral patellar stabilizers in the control group and with an increase in the VMO activity in the AKP group. In conclusion, electrical activity is an important factor in evaluating AKP and in AKP treatment evolution. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Objective: To asses the onset (%) of patella stabilizer muscles during maximal isometric contraction exercises (MIC) in individuals with and without signs of patellofemoral pain syndrome (PFPS) in open (OKC) and closed (CKC) kinetic chain exercises, Method: Assessments were carried out on 22 women; ten with no complains of anterior knee pain, and 12 with PFPS signs during MIC in OKC and CKC with the knee flexed at 90 degrees. The onset of the electromyographic activity of the vastus mediallis obliquus (VMO), vastus lateralis obliquus (VLO) and vastus lateralis longus (VLL) was identified by means of an algorithm in the Myosystem Br 1 software. The statistical analysis used was Chi-Square test and student`s t test, which are both tests with a level of significance at 5%. Results: The VMO and VLO muscles presented a greater onset compared to the VLL during OKC exercises for both groups and for the PFPS group without CCF No differences were observed between the groups. Conclusion: CKC and OKC exercises seem to benefit the synchronism of the musculature that supposedly benefits the patella stabilizer musculature, and can be recommended in physiotherapeutic treatment programs.
Resumo:
Objective: To examine the effect of the application of tape over the patella on the onset of electromyographic (EMG) activity of vastus medialis obliquus (VMO) relative to vastus lateralis (VL) in participants with and without patellofemoral pain syndrome (PFPS). Design: Randomised within subject. Settings: University laboratory. Participants: Ten participants with PFPS and 12 asymptomatic controls. Interventions: Three experimental taping conditions: no tape, therapeutic tape, and placebo tape. Main Outcome Measures: Electromyographic onset of VMO and VL assessed during the concentric and eccentric phases of a stair stepping task. Results: When participants with PFPS completed the stair stepping task, the application of therapeutic patellar tape was found to alter the temporal characteristics of VMO and VL activation, whereas placebo tape had no effect. In contrast, there was no change in the EMG onset of VMO and VL with the application of placebo or therapeutic tape to the knee in the asymptomatic participants. Conclusions: These data support the use of patellar taping as an adjunct to rehabilitation in people with PFPS.
Resumo:
We reviewed 19 patients (24 knees) with patellofemoral instability treated surgically with antero-medialisation of the tibial tubercle and lateral retinacular release. Twenty-two knees had recurrent patellar dislocation and two patellar subluxation. Lateral retinacular release was performed arthroscopically in 15 knees. Average follow-up was 52 (16-86) months. There was one postoperative haemarthrosis and one failed fixation, which needed surgical revision. The average Lysholm score improved from 63.3 to 98 and only one knee had persistent patello-femoral pain postoperatively. The patellar tilt angle improved from 9.4 degrees to 5.5 degrees . There were no redislocations. We find that the surgical technique produces a consistent correction of patellar instability, but long-term studies are needed to confirm whether it can prevent arthritic degeneration.
Resumo:
Patellar instability concerns mostly young and active patients. Because of the condition's multifactorial origin, knowledge about the risk factors of patella instability and the biomechanics of the femoropatellar joint are necessary to understand this disorder. Most of the patellar dislocations are spontaneously reduced. Only the patient's history, clinical examination and appropriate imaging lead to the correct diagnosis. If haemarthrosis is present, MRI is recommended to rule out concomitant injuries. A traumatic patellar dislocation without history of prior dislocation is treated conservatively. Surgical treatment is indicated in presence of intra-articular injury or for recurrent dislocations. The surgical procedure should correct the different factors of patella instability identified by preoperative analysis.
Resumo:
Freehand positioning of the femoral drill guide is difficult during hip resurfacing and the surgeon is often unsure of the implant position achieved peroperatively. The purpose of this study was to find out whether, by using a navigation system, acetabular and femoral component positioning could be made easier and more precise. Eighteen patients operated on by the same surgeon were matched by sex, age, BMI, diagnosis and ASA score (nine patients with computer assistance, nine with the regular ancillary). Pre-operative planning was done on standard AP and axial radiographs with CT scan views for the computer-assisted operations. The final position of implants was evaluated by the same radiographs for all patients. The follow-up was at least 1 year. No difference between both groups in terms of femoral component position was observed (p > 0.05). There was also no difference in femoral notching. A trend for a better cup position was observed for the navigated hips, especially for cup anteversion. There was no additional operating time for the navigated hips. Hip navigation for resurfacing surgery may allow improved visualisation and hip implant positioning, but its advantage probably will be more obvious with mini-incisions than with regular incision surgery.
Resumo:
TBC1D7 forms a complex with TSC1 and TSC2 that inhibits mTORC1 signaling and limits cell growth. Mutations in TBC1D7 were reported in a family with intellectual disability (ID) and macrocrania. Using exome sequencing, we identified two sisters homozygote for the novel c.17_20delAGAG, p.R7TfsX21 TBC1D7 truncating mutation. In addition to the already described macrocephaly and mild ID, they share osteoarticular defects, patella dislocation, behavioral abnormalities, psychosis, learning difficulties, celiac disease, prognathism, myopia, and astigmatism. Consistent with a loss-of-function of TBC1D7, the patient's cell lines show an increase in the phosphorylation of 4EBP1, a direct downstream target of mTORC1 and a delay in the initiation of the autophagy process. This second family allows enlarging the phenotypic spectrum associated with TBC1D7 mutations and defining a TBC1D7 syndrome. Our work reinforces the involvement of TBC1D7 in the regulation of mTORC1 pathways and suggests an altered control of autophagy as possible cause of this disease.
Resumo:
PURPOSE: The purpose of this study was to evaluate the clinical and subjective outcomes after arthroscopic-assisted double-bundle posterior cruciate ligament (PCL) reconstruction. METHODS: A series of 15 patients with grade III isolated chronic PCL tears underwent double-bundle PCL reconstruction. Of these patients, 8 (53%) had simultaneous fractures. The mean time from accident to surgery was 10.8 months (range, 8 to 15 months). The mean age at the time of surgery was 28.2 years (range, 17 to 43 years). All of the patients reported knee insecurity during activities of daily living or light sporting activities, with associated anterior knee pain in 5 patients. Preoperatively, posterolateral or posteromedial corner injuries were ruled out through accurate clinical examination. The knees were assessed before surgery and at a mean follow-up of 3.2 years (range, 2 to 5 years) with a physical examination, 4 different rating scales, and stress radiographs obtained with a Telos device (Telos, Marburg, Germany). RESULTS: Postoperative physical examination revealed a reduction of the posterior drawer and tibial step-off in all cases, although the posterior laxity was not completely normalized. Nevertheless, the patients were subjectively better after surgery. The subjective International Knee Documentation Committee score was significantly ameliorated. With regard to the objective International Knee Documentation Committee score, 6 knees (40%) were graded as abnormal because of posterior displacement of 6 mm or greater on follow-up stress radiographs with the Telos device. On the Lysholm knee scoring scale, the score was excellent in 13% of patients and good in 87%. The mean score on the Hospital for Special Surgery knee ligament rating scale was 85.8. The Tegner activity score showed an amelioration after surgery, but no patient resumed his or her preinjury level of activities. The postoperative stress radiographs revealed an improvement in posterior instability of 50% or more in all but 3 knees (20%). CONCLUSIONS: Our technique of double-bundle PCL reconstruction produced a significant reduction in knee symptoms and allowed the patients to return to moderate or strenuous activity, although the posterior tibial translation was not completely normalized and our results appear to be no better than the results of single-bundle PCL reconstruction. LEVEL OF EVIDENCE: Level IV, therapeutic case series.
Resumo:
PURPOSE: To evaluate the cause of recurrent pathologic instability after anterior cruciate ligament (ACL) surgery and the effectiveness of revision reconstruction using a quadriceps tendon autograft using a 2-incision technique. TYPE OF STUDY: Retrospective follow-up study. METHODS: Between 1999 and 2001, 31 patients underwent ACL revision reconstruction because of recurrent pathologic instability during sports or daily activities. Twenty-eight patients were reviewed after a mean follow-up of 4.2 years (range, 3.3 to 5.6 years). The mean age at revision surgery was 27 years (range, 18 to 41 years). The average time from primary procedure to revision surgery was 26 months (range, 9 to 45 months). A clinical, functional, and radiographic evaluation was performed. Also magnetic resonance imaging (MRI) or computed tomography (CT) scanning was performed. The International Knee Documentation Committee (IKDC), Lysholm, and Tegner scales were used. A KT-1000 arthrometer measurement (MEDmetric, San Diego, CA) by an experienced physician was made. RESULTS: Of the failures, 79% had radiographic evidence of malposition of their tunnels. In only 6 cases (21%) was the radiologic anatomy of tunnel placement judged to be correct on both the femoral and tibial side. The MRI or CT showed, in 6 cases, a too-centrally placed femoral tunnel. After revision surgery, the position of tunnels was corrected. A significant improvement of Lachman and pivot-shift phenomenon was observed. In particular, 17 patients had a negative Lachman test, and 11 patients had a grade I Lachman with a firm end point. Preoperatively, the pivot-shift test was positive in all cases, and at last follow-up in 7 patients (25%) a grade 1+ was found. Postoperatively, KT-1000 testing showed a mean manual maximum translation of 8.6 mm (SD, 2.34) for the affected knee; 97% of patients had a maximum manual side-to-side translation <5 mm. At the final postoperative evaluation, 26 patients (93%) graded their knees as normal or nearly normal according to the IKDC score. The mean Lysholm score was 93.6 (SD, 8.77) and the mean Tegner activity score was 6.1 (SD, 1.37). No patient required further revision. Five patients (18%) complained of hypersensitive scars from the reconstructive surgery that made kneeling difficult. CONCLUSIONS: There were satisfactory results after ACL revision surgery using quadriceps tendon and a 2-incision technique at a minimum 3 years' follow-up; 93% of patients returned to sports activities. LEVEL OF EVIDENCE: Level IV, case series, no control group.
Resumo:
Discarded tires present major disposal and environmental problems. One method of recycling tires is to use finely ground rubber from tires in asphalt cement concrete (ACC). This process has been researched in Iowa since 1991. There are currently eight projects being researched. This project involved using crumb rubber modifier (CRM) in ACC using a dry process. This project is located on US 63 in Howard County. It involved 17 test sections. There were five test sections using 20 lb of CRM per ton, four test sections using 10 lb of CRM per ton and eight test sections using a conventional mix. Not only were different mixes used, but the overlay was also placed in various thicknesses ranging from 2 in. to 8 in. (5 cm to 20 cm). The project was completed in August 1994. The project construction went well with only minor problems. This report contains information about procedures and tests that were completed and those that will be completed. Evaluation on the project will continue for five years.
Resumo:
Asphalt concrete resurfacing is the most commonly utilized rehabilitation practice used by the Iowa Department of Transportation. The major problem with asphalt concrete resurfacing is the reflective cracking from underlying cracks and joints in the portland cement concrete (PCC) pavement. Cracking and seating the PCC prior to an asphalt overlay was the construction method evaluated in this project. There was cracking and seating on portions of the project and portions were overlaid without this process. There were also different overlay thicknesses used. Comparisons of crack and seating to the normal overlay method and the different depths are compared in this report. Cracking and seating results in some structural loss, but does reduce the problem of reflection cracking.