998 resultados para Patch Test
Resumo:
BACKGROUND Skin patch test is the gold standard method in diagnosing contact allergy. Although used for more than 100 years, the patch test procedure is performed with variability around the world. A number of factors can influence the test results, namely the quality of reagents used, the timing of the application, the patch test series (allergens/haptens) that have been used for testing, the appropriate interpretation of the skin reactions or the evaluation of the patient's benefit. METHODS We performed an Internet -based survey with 38 questions covering the educational background of respondents, patch test methods and interpretation. The questionnaire was distributed among all representatives of national member societies of the World Allergy Organization (WAO), and the WAO Junior Members Group. RESULTS One hundred sixty-nine completed surveys were received from 47 countries. The majority of participants had more than 5 years of clinical practice (61 %) and routinely carried out patch tests (70 %). Both allergists and dermatologists were responsible for carrying out the patch tests. We could observe the use of many different guidelines regardless the geographical distribution. The use of home-made preparations was indicated by 47 % of participants and 73 % of the respondents performed 2 or 3 readings. Most of the responders indicated having patients with adverse reactions, including erythroderma (12 %); however, only 30 % of members completed a consent form before conducting the patch test. DISCUSSION The heterogeneity of patch test practices may be influenced by the level of awareness of clinical guidelines, different training backgrounds, accessibility to various types of devices, the patch test series (allergens/haptens) used for testing, type of clinical practice (public or private practice, clinical or research-based institution), infrastructure availability, financial/commercial implications and regulations among others. CONCLUSION There is a lack of a worldwide homogeneity of patch test procedures, and this raises concerns about the need for standardization and harmonization of this important diagnostic procedure.
Resumo:
The pattern of contact sensitization to the supposedly most important allergens assembled in the baseline series differs between countries, presumably at least partly because of exposure differences. Objectives. To describe the prevalence of contact sensitization to allergens tested in consecutive patients in the years 2007 and 2008, and to discuss possible differences.
Resumo:
BACKGROUND: Aeroallergens from house dust mite (HDM) may be an important trigger in a subgroup of patients with atopic dermatitis (AD). HDM and cockroach (CR) contain cross-reactive allergens, such as tropomyosin. OBJECTIVE: To investigate the diagnostic value of patch testing with an aeroallergen and the role of CR allergen and HDM allergen in persons with AD. METHODS: We performed skin prick tests (SPT) with a panel of common aeroallergens and total serum immunoglobulin (Ig)E and specific IgE tests for CR and HDM on 23 patients with AD and 9 nonatopic control participants. Atopy patch tests (APT) were performed with CR and HDM extracts on clinically uninvolved skin on the back, and evaluated after 48 and 72 hours. RESULTS: A positive APT reaction to CR was found in 10/23 (43%) patients with AD. No positive reactions were observed in the nonatopic control participants. Positive APT reactions for CR showed no significant correlation with SPT or specific IgE levels for this allergen. Twelve of the 23 (52%) patients with AD were also sensitized to HDM. There was no significant correlation between positive results for SPT, APT, and specific IgE to CR and HDM. CONCLUSION: We demonstrate that CR allergens can induce positive patch test reactions in patients with AD. The absence of a significant correlation to SPT and specific IgE antibodies suggests that T-cell- and IgE-sensitization may be mediated by different allergens. There was no significant relationship between CR and HDM sensitivity, thus indicating no major cross-reactivity.
Resumo:
BACKGROUND AND OBJECTIVES The distinction of oral lichenoid reactions from oral lichen planus may be difficult in a clinical setting. Our aims were to ascertain the utility of patch testing to confirm the association of oral lichenoid reactions with dental restorations and to identify the benefits of replacement of restorations, primarily made of amalgam. METHODS Patients seen in an oral medicine unit over a 10-year period diagnosed with oral lichenoid reactions, with oral lichen planus resistant to treatment or with atypical lichenoid features were included in this study. All had been subjected to skin patch testing. Histopathology reports blinded to patch test results were scrutinized. Patch-test-positive subjects were advised to have their restorations replaced. All were followed up to determine disease resolution for at least 3 months thereafter. RESULTS Among 115 patients, 67.8% patients reacted positive to a dental material and nearly a quarter to mercury or amalgam. No correlation was found between pathology and skin patch testing results (P = 0.44). A total of 87 patients were followed up in clinic, and among 26 patch-test-positive patients who had their amalgam fillings replaced, moderate to complete resolution was noted in 81%. CONCLUSIONS Skin patch testing is a valuable tool to confirm clinically suspected oral lichenoid reactions. Pathology diagnoses of oral lichenoid reactions did not correlate with patch test results. Prospective studies are needed to ascertain that a clinically suspected oral lichenoid reaction with a positive patch test result may resolve after the replacement of amalgam fillings.
Resumo:
Studies assessing skin irritation to chemicals have traditionally used laboratory animals; however, such methods are questionable regarding their relevance for humans. New in vitro methods have been validated, such as the reconstructed human epidermis (RHE) model (Episkin®, Epiderm®). The comparison (accuracy) with in vivo results such as the 4-h human patch test (HPT) is 76% at best (Epiderm®). There is a need to develop an in vitro method that better simulates the anatomo-pathological changes encountered in vivo. To develop an in vitro method to determine skin irritation using human viable skin through histopathology, and compare the results of 4 tested substances to the main in vitro methods and in vivo animal method (Draize test). Human skin removed during surgery was dermatomed and mounted on an in vitro flow-through diffusion cell system. Ten chemicals with known non-irritant (heptylbutyrate, hexylsalicylate, butylmethacrylate, isoproturon, bentazon, DEHP and methylisothiazolinone (MI)) and irritant properties (folpet, 1-bromohexane and methylchloroisothiazolinone (MCI/MI)), a negative control (sodiumchloride) and a positive control (sodiumlaurylsulphate) were applied. The skin was exposed at least for 4h. Histopathology was performed to investigate irritation signs (spongiosis, necrosis, vacuolization). We obtained 100% accuracy with the HPT model; 75% with the RHE models and 50% with the Draize test for 4 tested substances. The coefficients of variation (CV) between our three test batches were <0.1, showing good reproducibility. Furthermore, we reported objectively histopathological irritation signs (irritation scale): strong (folpet), significant (1-bromohexane), slight (MCI/MI at 750/250ppm) and none (isoproturon, bentazon, DEHP and MI). This new in vitro test method presented effective results for the tested chemicals. It should be further validated using a greater number of substances; and tested in different laboratories in order to suitably evaluate reproducibility.
Resumo:
Objetivo: Caracterizar los sectores económicos con mayor susceptibilidad de exposición a agentes químicos carcinógenos, categorizados en el grupo 1 por la Agencia Internacional para la Investigación del Cáncer IARC (formaldehído, polvo de madera, benceno y sílice cristalina) afiliadas a una Administradora de riesgos Laborales (ARL) en Colombia entre el periodo 2011 a 2014. Método: Estudio de tipo descriptivo retrospectivo con datos históricos obtenidos desde 2011 hasta 2014. De acuerdo con el número de mediciones que se realizó en cada área y cargo de las empresas objeto de estudio, se utilizó la medición basal para determinar el estado inicial y evaluar de manera concurrente la exposición de estos cuatro agentes químicos. Resultados: En total se obtuvieron 201 mediciones de higiene industrial para cuatro agentes químicos carcinógenos. Los resultados mostraron que índice de riesgo de la exposición a agentes químicos carcinógenos en diferentes empresas, se encuentra en algunos casos en niveles altos o críticos dado que superar los valores máximos permisibles definidos por la Conferencia Americana de Higienistas Industriales de Gobierno (ACGIH). Conclusión: Los trabajadores de diferentes empresas en Colombia están expuestas a diferentes tipos de concentraciones por agentes químicos cancerígenos. Las concentraciones ambientales obtenidas en el ambiente laboral en algunos casos excedieron las concentraciones máximas permitidas, por lo que se recomienda que las empresas e instituciones del país fortalezcan las medidas de prevención, vigilancia y control para minimizar los riegos a que pueden estar expuestos sus trabajadores.
Resumo:
Titanium dental implants have been common practice in the dental office, which can increases the number of allergic reactions to this material. Objectives: to alert dental surgeons and specialists of this possible phenomenon through a literature review. Material and methods: an electronic search at PubMed was performed with the keywords “dental implants”, “titanium”, and “allergy” from January 1990 to May 2013. Only articles published in the English language were included. Letters to editor were excluded. Results: from the 22 initially retrieved articles, only 7 were included, being 4 clinical case reports and 3 experimental studies. For clinical cases, the reactions included edema, erythema, exfoliative cheilitis, and eczema. Regarding experimental studies, skin rash and dermatitis were reported. A patch test was not used in two clinical reports. Only one study used histological analysis to attest the lack of allergic reactions. Conclusion: within the limits of the available literature, allergic reactions to titanium dental implants are extremely rare and seem to be related to the female gender. More controlled clinical studies are necessary to elucidate this question.
Resumo:
The generalized finite element method (GFEM) is applied to a nonconventional hybrid-mixed stress formulation (HMSF) for plane analysis. In the HMSF, three approximation fields are involved: stresses and displacements in the domain and displacement fields on the static boundary. The GFEM-HMSF shape functions are then generated by the product of a partition of unity associated to each field and the polynomials enrichment functions. In principle, the enrichment can be conducted independently over each of the HMSF approximation fields. However, stability and convergence features of the resulting numerical method can be affected mainly by spurious modes generated when enrichment is arbitrarily applied to the displacement fields. With the aim to efficiently explore the enrichment possibilities, an extension to GFEM-HMSF of the conventional Zienkiewicz-Patch-Test is proposed as a necessary condition to ensure numerical stability. Finally, once the extended Patch-Test is satisfied, some numerical analyses focusing on the selective enrichment over distorted meshes formed by bilinear quadrilateral finite elements are presented, thus showing the performance of the GFEM-HMSF combination.
Resumo:
One to three percent of patients exposed to intravenously injected iodinated contrast media (CM) develop delayed hypersensitivity reactions. Positive patch test reactions, immunohistological findings, and CM-specific proliferation of T cells in vitro suggest a pathogenetic role for T cells. We have previously demonstrated that CM-specific T cell clones (TCCs) show a broad range of cross-reactivity to different CM. However, the mechanism of specific CM recognition by T cell receptors (TCRs) has not been analysed so far.
Resumo:
BACKGROUND: Quinolones are widely used, broad spectrum antibiotics that can induce immediate- and delayed-type hypersensitivity reactions, presumably either IgE or T cell mediated, in about 2-3% of treated patients. OBJECTIVE: To better understand how T cells interact with quinolones, we analysed six patients with delayed hypersensitivity reactions to ciprofloxacin (CPFX), norfloxacin (NRFX) or moxifloxacin (MXFX). METHODS: We confirmed the involvement of T cells in vivo by patch test and in vitro by means of the lymphocyte proliferation test (LTT). The nature of the drug-T cell interaction as well as the cross-reactivity with other quinolones were investigated through the generation and analysis (flow cytometry and proliferation assays) of quinolone-specific T cell clones (TCC). RESULTS: The LTT confirmed the involvement of T cells because peripheral blood mononuclear cells (PBMC) mounted an enhanced in vitro proliferative response to CPFX and/or NRFX or MXFX in all patients. Patch tests were positive after 24 and 48 h in three out of the six patients. From two patients, CPFX- and MXFX-specific CD4(+)/CD8(+) T cell receptor (TCR) alphabeta(+) TCC were generated to investigate the nature of the drug-T cell interaction as well as the cross-reactivity with other quinolones. The use of eight different quinolones as antigens (Ag) revealed three patterns of cross-reactivity: clones exclusively reacting with the eliciting drug, clones with a limited cross-reactivity and clones showing a broad cross-reactivity. The TCC recognized quinolones directly without need of processing and without covalent association with the major histocompatability complex (MHC)-peptide complex, as glutaraldehyde-fixed Ag-presenting cells (APC) could present the drug and washing quinolone-pulsed APC removed the drug, abrogating the reactivity of quinolone-specific TCC. CONCLUSION: Our data show that T cells are involved in delayed immune reactions to quinolones and that cross-reactivity among the different quinolones is frequent.
Resumo:
BACKGROUND: Continual surveillance based on patch test results has proved useful for the identification of contact allergy. OBJECTIVES: To provide a current view on the spectrum of contact allergy to important sensitizers across Europe. PATIENTS/METHODS: Clinical and patch test data of 19 793 patients patch tested in 2005/2006 in the 31 participating departments from 10 European countries (the European Surveillance System on Contact Allergies' (ESSCA) www.essca-dc.org) were descriptively analysed, aggregated to four European regions. RESULTS: Nickel sulfate remains the most common allergen with standardized prevalences ranging from 19.7% (central Europe) to 24.4% (southern Europe). While a number of allergens shows limited variation across the four regions, such as Myroxylon pereirae (5.3-6.8%), cobalt chloride (6.2-8.8%) or thiuram mix (1.7-2.4%), the differences observed with other allergens may hint on underlying differences in exposures, for example: dichromate 2.4% in the UK (west) versus 4.5-5.9% in the remaining EU regions, methylchloroisothiazolinone/methylisothiazolinone 4.1% in the South versus 2.1-2.7% in the remaining regions. CONCLUSIONS: Notwithstanding residual methodological variation (affecting at least some 'difficult' allergens) tackled by ongoing efforts for standardization, a comparative analysis as presented provides (i) a broad overview on contact allergy frequencies and (ii) interesting starting points for further, in-depth investigation.
Resumo:
BACKGROUND: Eczematous skin lesions of atopic dermatitis (AD) as well as allergic and irritant contact dermatitis (ACD, ICD) are characterized by the same typical clinical signs, although due to different causes. In both AD and ACD, the presence of T helper 17 cells which play an important role in host defense, has been reported. Furthermore, IL-17 is involved in tissue repair and remodeling. This study aimed to investigate IL-17 expression in acute eczematous skin lesions and correlate it with markers of remodeling in AD, ACD, and ICD. METHODS: Skin specimens were taken from positive patch test reactions to aeroallergens, contact allergens, and irritants at days 2, 3, and 4. Inflammatory cells as well as the expression of cytokines and extracellular matrix proteins were evaluated by immunofluorescence staining and confocal microscopy. RESULTS: Allergic contact dermatitis and ICD were characterized by IFN-γ expression, whereas in AD lesions, IL-13 expression and high numbers of eosinophils were the prominent phenotype. Expression of IL-17, but also IL-21 and IL-22, was observed in all eczema subtypes. The number of IL-22+ T cells correlated with the number of eosinophils. Markers of remodeling such as MMP-9, procollagen-3, and tenascin C were observed in all acute eczematous lesions, while a correlation of IL-17+ T cell numbers with tenascin C-expressing cells and MMP-9+ eosinophils was apparent. CONCLUSION: The expression of IL-17 and related cytokines, such as IL-22, was demonstrated in acute eczematous lesions independent of their pathogenesis. Our results suggest a potential role for IL-17 in remodeling of the skin.
Resumo:
A finite-strain solid–shell element is proposed. It is based on least-squares in-plane assumed strains, assumed natural transverse shear and normal strains. The singular value decomposition (SVD) is used to define local (integration-point) orthogonal frames-of-reference solely from the Jacobian matrix. The complete finite-strain formulation is derived and tested. Assumed strains obtained from least-squares fitting are an alternative to the enhanced-assumed-strain (EAS) formulations and, in contrast with these, the result is an element satisfying the Patch test. There are no additional degrees-of-freedom, as it is the case with the enhanced-assumed-strain case, even by means of static condensation. Least-squares fitting produces invariant finite strain elements which are shear-locking free and amenable to be incorporated in large-scale codes. With that goal, we use automatically generated code produced by AceGen and Mathematica. All benchmarks show excellent results, similar to the best available shell and hybrid solid elements with significantly lower computational cost.
Resumo:
A finite-strain solid–shell element is proposed. It is based on least-squares in-plane assumed strains, assumed natural transverse shear and normal strains. The singular value decomposition (SVD) is used to define local (integration-point) orthogonal frames-of- reference solely from the Jacobian matrix. The complete finite-strain formulation is derived and tested. Assumed strains obtained from least-squares fitting are an alternative to the enhanced-assumed-strain (EAS) formulations and, in contrast with these, the result is an element satisfying the Patch test. There are no additional degrees-of-freedom, as it is the case with the enhanced- assumed-strain case, even by means of static condensation. Least-squares fitting produces invariant finite strain elements which are shear-locking free and amenable to be incorporated in large-scale codes. With that goal, we use automatically generated code produced by AceGen and Mathematica. All benchmarks show excellent results, similar to the best available shell and hybrid solid elements with significantly lower computational cost.