993 resultados para Passive cooling strategy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Passive cooling system has become an attractive option to design and modify homes to achieve thermal comfort. The system provides cooling through the use of passive processes, which often use heat flow paths that do not exist in conventional or bioclimatic buildings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the original version of this article (Ahmed et al. 2014), the authors noted that the author list was published with errors. The correct author list can be found in this erratum. The publisher would like to apologise to the authors for this error.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Building roofs play a very important role in the energy balance of buildings, especially in summer, when they are hit by a rather high solar irradiance. Depending on the type of finishing layer, roofs can absorb a great amount of heat and reach quite high temperatures on their outermost surface, which determines significant room overheating. However, the use of highly reflective cool materials can help to maintain low outer surface temperatures; this practice may improve indoor thermal comfort and reduce the cooling energy need during the hot season.This technology is currently well known and widely used in the USA, while receiving increasing attention in Europe. In order to investigate the effectiveness of cool roofs as a passive strategy for passive cooling in moderately hot climates, this paper presents the numerical results of a case study based on the dynamic thermal analysis of an existing office building in Catania (southern Italy, Mediterranean area). The results show how the application of a cool paint on the roof can enhance the thermal comfort of the occupants by reducing the operative temperatures of the rooms and to reduce the overall energy needs of the building for space heating and cooling.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is the third in a series of reports planned for this project. The aim of this research is to conduct a comparative study of current legislation or guidelines at the federal, state and local government levels to confirm if any natural ventilation criteria are required at the subdivision development stage of planning. It also seeks to discover if there are any other incentives, statutory planning or development principles that encourage developers to orient subdivision lots to maximize natural ventilation for the dwellings. Findings from the research in this report are intended to contribute to the discussion on the development of an enhanced lot rating methodology for sustainable subdivisions as documented in other reports in this series.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A major project in the Sustainable Built Assets core area is the Sustainable Sub-divisions – Ventilation Project that is the second stage of a planned series of research projects focusing on sustainable sub-divisions. The initial project, Sustainable Sub-divisions: Energy focused on energy efficiency and examined the link between dwelling energy efficiency and sub-divisional layout. In addition, the potential for on site electricity generation, especially in medium and high-density developments, was also examined. That project recommended that an existing lot-rating methodology be adapted for use in SEQ through the inclusion of sub divisional appropriate ventilation data. Acquiring that data is the object of this project. The Sustainable Sub-divisions; Ventilation Project will produce a series of reports. The first report (Report 2002-077-B-01) summarised the results from an industry workshop and interviews that were conducted to ascertain the current attitudes and methodologies used in contemporary sub-division design in South East Queensland. The second report (Report 2002-077-B-02) described how the project is being delivered as outlined in the Project Agreement. It included the selection of the case study dwellings and monitoring equipment and data management process. This third report (Report 2002-077-B-03) provides an analysis and review of the approaches recommended by leading experts, government bodies and professional organizations throughout Australia that aim to increase the potential for passive cooling and heating at the subdivision stage. This data will inform issues discussed on the development of the enhanced lot-rating methodology in other reports of this series. The final report, due in June 2007, will detail the analysis of data for winter 2006 and summer 2007, leading to the development and delivery of the enhanced lot-rating methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Roofs are severely hit by solar radiation in summer; hence the use of cool materials on the finishing layer provides a significant reduction in the heat flow entering the building, with sensible attenuation in the building cooling load. In this paper, a case study is presented, based on the dynamic simulation of an existing office building in Catania (southern Italy). Here, a part of the roof has been recently treated with a commercial cool paint, with the aim of improving thermal comfort in summer. Hence, the simulations represent a preliminary study that will allow assessing the expected effectiveness of the intervention. More in detail, the results of the simulations will be discussed in terms of both thermal comfort and energy savings, through the evaluation of parameters such as the roof surface temperature, the operative temperature and the cooling load for both conditions, i.e. with and without the cool paint. The paper also discusses the potential increase in the energy needs for winter heating, and looks at the overall annual balance in terms of primary energy; this is made by considering different climatic conditions and envelope characteristics. These aspects are usually not well highlighted in the current scientific literature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of vegetal systems in facades affects the reduction of the buildings' energy demand, the attenuation of the urban heat island (UHI) and the filtration of pollutants present in the air. Even so, up to now the knowledge about the effect of this type of systems on the thermal performance of insulated facades is limited. This article presents the results of an experimental study carried out in a vegetal facade located in a continental Mediterranean climate zone. The objective is to study the effect of a vegetal finishing, formed by plants and substrate, on the thermal-energy performance of an insulated facade under summer conditions. To this effect, the thermal data obtained from two full-scale experimental mock-ups of the same dimensions and composition of the enclosure and only different in the south facade's enclosure where one incorporates a vegetation layer are compared and analysed. The results show that, in spite of the high thermal resistance of the enclosure, the effect of the vegetation is very positive, particularly in the warmer hours of the day. Therefore, vegetal facades can be used as a passive cooling strategy, reducing the consumption of energy for refrigeration and improving the comfort conditions of the users. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El presente trabajo de investigación determina las características de la cerámica que más eficientemente se comporta a evaporación y a enfriamiento. Con el objeto de ser empleado como material integrado en la envolvente de los edificios para reducir su carga de refrigeración. La cerámica es un buen material para ser empleado para la refrigeración por evaporación. Es un sólido poroso inerte que, tras ser sometido a cocción a temperaturas por encima de los 900ºC, resulta uno de los materiales que mejor se comportan como contenedor de agua en su red capilar para, posteriormente, ir liberándola por evaporación al mismo tiempo que se enfría su superficie. La metodología general de investigación, se divide en tres etapas: Búsqueda y análisis del estado de la técnica y de la investigación. Estudio teórico de la eficacia del enfriamiento evaporativo como estrategia de enfriamiento pasivo en la arquitectura. Etapa experimental, desarrollada en tres fases: una primera de definición de los parámetros determinantes del Enfriamiento Evaporativo en piezas cerámicas, una segunda de selección cerámica y diseño de ensayos experimentales y una tercera de caracterización de la cerámica bajo criterios de evaporación y de enfriamiento. El recorrido por el estado de la cuestión ha identificado las aplicaciones tecnológicas y las investigaciones científicas que emplean el Enfriamiento Evaporativo con piezas cerámicas como técnica de enfriamiento. Como resultado se ha obtenido una tabla de clasificación de sistemas de enfriamiento evaporativo y se ha constatado que el conjunto de las aplicaciones están centradas en el diseño de piezas o sistemas pero que, sin embargo, no existe una definición de las características de la cerámica para su empleo como material de enfriamiento por evaporación. El estudio teórico de la eficacia del empleo del enfriamiento evaporativo como estrategia de enfriamiento pasivo en la arquitectura se ha realizado mediante cálculos de porcentaje de ampliación de horas en confort con empleo de técnicas de enfriamiento evaporativo directo e indirecto (EED y EEI). Como resultado se obtienen unos mapas para el ámbito español de potencial de aplicación del EED y EEI. Los resultados permiten afirmar que mediante EE se puede llegar a confort en prácticamente la totalidad de las horas de los días más cálidos del año en muchas localidades. La metodología experimental se ha desarrollado en tres fases. En la fase inicial, se han definido los parámetros determinantes del enfriamiento evaporativo en un medio cerámico mediante ensayos experimentales de capacidad de evaporación y de caracterización. Se realizaron un total de 12 ensayos. Se determinó que el material cerámico tiene una gran influencia en la capacidad de evaporación y enfriamiento en las piezas cerámicas, apoyando la hipótesis inicial y la necesidad de caracterizar el material. La primera fase empírica se centró en la selección cerámica y el diseño de los ensayos experimentales de comportamiento hídrico. Se seleccionaron muestras de 5 tipos de cerámica. Se realizaron 4 tipos de ensayos de caracterización y 6 tipos de ensayos experimentales de comportamiento hídrico (total 123 muestras ensayadas). Los resultados obtenidos son de dos tipos, por un lado, se determinó cuál es el tipo de cerámica que más eficientemente se comporta a EE y, por otro, se rediseñaron los ensayos de la última fase experimental. Para la segunda fase experimental se seleccionaron cerámicas de fabricación manual abarcando el mayor número de localidades del ámbito español. Se realizaron ensayos de caracterización de 7 tipos y ensayos de comportamiento hídrico de 5 tipos (total 197 muestras ensayadas). Los resultados de caracterización han permitido aportar unos rangos de las características de la cerámica que más eficientemente se comporta en los ensayos de comportamiento hídrico. Al final de la investigación se ha caracterizado el material cerámico aportando características acerca de su porosidad, capacidad de absorción, color, rugosidad y mineralogía. Así como datos de referencia de su comportamiento hídrico. Además se ha desarrollado una metodología de ensayo específica que permite evaluar la capacidad de enfriamiento eficiente de una pieza cerámica. ABSTRACT The purpose of this research is to determine the characteristics of ceramic materials having the most efficient performance in terms of evaporation and cooling, so that they can be integrated in building envelopes to reduce cooling loads. Ceramics are suitable materials for cooling through passive evaporation. After being fired at temperatures over 900 °C (1,652 °F), the capillary network of this inert porous medium turns to be excellent to retain water, which is progressively liberated by evaporation while the material surface gets colder. Research methodology has involved the following steps: Search and analysis on the state of the art in technology and research. Theoretical study on the efficiency of evaporation as passive cooling strategies in buildings. Experimental stage developed in three phases, namely: definition of parameters determining evaporative cooling in ceramic elements; ceramic selection and design of experimental tests; characterization of ceramic materials under evaporation and cooling criteria. Search and analysis on the state of the art in this field have been useful to identify technology applications and scientific research where ceramics are employed for evaporative cooling. The resulting table shows that applications are wholly focused on the design of pieces and systems. Nonetheless, there is lack of definition of material characteristics in this scope. The theoretical study on efficiency of the passive strategy applied to buildings has been realized by calculation of the percentage increase in comfort hours through direct/indirect evaporative cooling techniques (DEC/IEC). The mapping of their potential application in Spain clearly shows that comfort conditions can be reached in almost all the hours of the hottest days in many towns. In the initial phase of the experimental stage, parameters determining evaporative cooling in ceramic media have been defined. For this purpose, characterization tests and evaporation and cooling rates experiments have been carried out; the number of samples tested amounted to 12. It has been concluded that material characteristics have great influence on these rates, which supports the initial hypothesis and the need for their characterization. The first empirical phase has focused on ceramic selection and design of water behaviour experimental methods. The samples covered five different kinds of ceramic materials. Four different characterization tests and six different water behaviour experiments were carried out; the number of samples tested amounted to 123. The experimental testing procedures served to determine the most efficient types of ceramic materials in terms of evaporative cooling efficiency and, at the same time, made it necessary to change the original designed experimental test for the last phase. In the second phase, a number of varied hand-made ceramic tiles have been selected. Seven different characterization tests and five different water behaviour tests were carried out; the number of samples amounted to 197. The results of characterization served to establish a range of features in ceramic materials according to their efficiency in water behaviour experiments. Finally, ceramic materials have been characterized according to porosity, water absorption, colour, surface roughness and mineralogy. Also, reference data regarding water behaviour have been included. Moreover, an innovative and specific experimental test to evaluate cooling efficiency of ceramic tiles has been developed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study compared the effects of a low-frequency electrical stimulation (LFES; Veinoplus® Sport, Ad Rem Technology, Paris, France), a low-frequency electrical stimulation combined with a cooling vest (LFESCR) and an active recovery combined with a cooling vest (ACTCR) as recovery strategies on performance (racing time and pacing strategies), physiologic and perceptual responses between two sprint kayak simulated races, in a hot environment (∼32 wet-bulb-globe temperature). Eight elite male kayakers performed two successive 1000-m kayak time trials (TT1 and TT2), separated by a short-term recovery period, including a 30-min of the respective recovery intervention protocol, in a randomized crossover design. Racing time, power output, and stroke rate were recorded for each time trial. Blood lactate concentration, pH, core, skin and body temperatures were measured before and after both TT1 and TT2 and at mid- and post-recovery intervention. Perceptual ratings of thermal sensation were also collected. LFESCR was associated with a very likely effect in performance restoration compared with ACTCR (99/0/1%) and LFES conditions (98/0/2%). LFESCR induced a significant decrease in body temperature and thermal sensation at post-recovery intervention, which is not observed in ACTCR condition. In conclusion, the combination of LFES and wearing a cooling vest (LFESCR) improves performance restoration between two 1000-m kayak time trials achieved by elite athletes, in the heat.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents an analysis of an organic Rankine cycle (ORC) with dry cooling system aided by an earth-coupled passive cooling system. Several organic fluids were considered as working fluids in the ORC in the temperature range of 125-200 degrees C. An earth-air-heat-exchanger (EMU) is studied for a location in the United States (Las Vegas) and another in India (New Delhi), to pre cool the ambient air before entering an air-cooled condenser (ACC). It was observed that the efficiency of the system improved by 1-3% for the system located in Las Vegas and fluctuations associated with temperature variations of the ambient air were also reduced when the EAHE system was used. A ground-coupled heat pump (GCHP) is also studied for these locations where cooling water is pre cooled in an underground buried pipe before entering a condenser heat exchanger in a closed loop. The area of the buried pipe and the condenser size are calculated per kW of power generation for various working fluids.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

IDEAhaus:
A Comfortable Home for the UK’s Future Climate

This paper describes the result of a project to develop climate adaptation design strategies funded by the UK’s Technology Strategy Board. The aim of the project was to look at the threats and opportunities presented by industrialised and lightweight housebuilding techniques in the light of predicted increases in flooding and overheating. This case study presents detailed concept designs for a future systemised housing product which can be Industrialised, Delightful, Efficient and Adaptable; an IDEAhaus.
Keywords: climate change adaptation, thermal comfort, passive cooling, flood residence, industrialised housing, mass customisation

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper describes the result of a project to develop climate adaptation design strategies funded by the UK’s Technology Strategy Board. The aim of the project was to look at the threats and opportunities presented by industrialized and house-building techniques in the light of predicted future increases in flooding and overheating due to anthropogenic climate change. The paper shows that the thermal performance of houses built to the current UK Building Regulations is not adequate to cope with changing weather patterns, and in light of this, develops a detailed design for a new house: one that is industrially produced and climatically resilient, but affordable. This detailed concept IDEAhaus of a modular house is not only flood-proof to a water depth of 750 mm, but also is designed to utilize passive cooling, which dramatically reduces the amount of overheating, both now and in the future.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Natural ventilation is an efficient bioclimatic strategy, one that provides thermal comfort, healthful and cooling to the edification. However, the disregard for quality environment, the uncertainties involved in the phenomenon and the popularization of artificial climate systems are held as an excuse for those who neglect the benefits of passive cooling. The unfamiliarity with the concept may be lessened if ventilation is observed in every step of the project, especially in the initial phase in which decisions bear a great impact in the construction process. The tools available in order to quantify the impact of projected decisions consist basically of the renovation rate calculations or computer simulations of fluids, commonly dubbed CFD, which stands for Computational Fluid Dynamics , both somewhat apart from the project s execution and unable to adapt for use in parametric studies. Thus, we chose to verify, through computer simulation, the representativeness of the results with a method of simplified air reconditioning rate calculation, as well as making it more compatible with the questions relevant to the first phases of the project s process. The case object consists of a model resulting from the recommendations of the Código de Obras de Natal/ RN, customized according to the NBR 15220. The study has shown the complexity in aggregating a CFD tool to the process and the need for a method capable of generating data at the compatible rate to the flow of ideas and are discarded during the project s development. At the end of our study, we discuss the necessary concessions for the realization of simulations, the applicability and the limitations of both the tools used and the method adopted, as well as the representativeness of the results obtained

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Shopping centre is a long term investment in which Greenfield development decisions are often taken based on risks analysis regarding construction costs, location, competition, market and an expected DCF. Furthermore, integration between the building design, project planning, operational costs and investment analysis is not entirely considered by the investor at the decision making stage. The absence of such information tends to produce certain negative impacts on the future running costs and annual maintenance of the building, especially on energy demand and other occupancy expenses paid by the tenants to the landlord. From the investor´s point of view, this blind spot in strategy development will possibly decrease their profit margin as changes in the occupancy expenses[ ] have a direct outcome on the profit margin. In order to try to reduce some higher operating cost components such as energy use and other utility savings as well as their CO2 emissions, quite a few income properties worldwide have some type of environmental label such as BREEAM and LEED. The drawback identified in this labelling is that usually the investments required to get an ecolabel are high and the investor finds no direct evidence that it increases market value. However there is research on certified commercial properties (especially offices) that shows better performance in terms of occupancy rate and rental cost (Warren-Myers, 2012). Additionally, Sayce (2013) says that the certification only provides a quick reference point i.e. the lack of a certificate does not indicate that a building is not sustainable or efficient. Based on the issues described above, this research compares important components of the development stages such as investments costs, concept/ strategy development as well as the current investor income and property value. The subjects for this analysis are a shopping centre designed with passive cooling/bioclimatic strategies evaluated at the decision making stage, a certified regional shopping centre and a non-certified standard regional shopping centre. Moreover, the proposal intends to provide decision makers with some tools for linking green design features to the investment analysis in order to optimize the decision making process when looking into cost savings and design quality.