937 resultados para Particle analyzer
Resumo:
ABSTRACT Tractor traveling speed can influence the quality of spraying depending on the application technology used. This study aimed to evaluate the droplet spectrum, the deposition and uniformity of spray distribution with different spraying systems and traveling speeds of a self-propelled sprayer in two phenological stages of the cotton plant (B9 and F13). The experimental design was randomized blocks and treatments were three spraying techniques: common flat spray tips; tilted flat jet with air induction, at 120 L ha-1; and rotary atomizer disk, 20 L ha-1, combined with four traveling speeds: 12, 15, 18 and 25 km h-1, with four replications. Spraying deposition was evaluated for both leaf surfaces from the cotton plant apex and base (stage B9) and middle part of the plant (stage F13) with a cupric marker. A laser particle analyzer also assessed the droplet spectrum. The centrifugal power spray system produces more homogeneous droplet spectrum and increased penetration of droplets into the canopy in both phenological stages. Variation on the operating conditions necessary for increased traveling speed negatively influences the pattern of spraying deposits.
Resumo:
Työn teoriaosassa tutkittiin materiaalin hienontamista jauhatuksen näkökulmasta. Jauhatuksessa keskityttiin ultrahienojauhatukseen ja siinä käytettäviin myllyihin, jois-ta lähimmin tarkasteltiin helmimyllyä ja sen toimintaparametrien vaikutusta jauhau-tuvuuteen. Lisäksi teoriaosassa tutkittiin jauhatuksen energiankulutusta, joka on yksi jauhatuksen suurimmista ominaisuuksista. Työn kokeellisessa osassa tutkittiin kalkkikiven jauhautuvuutta ja jauhatuksen omi-naisenergiankulutusta käyttäen kolmea erilaista sekoitinelintä. Kokeissa myllynä käy-tettiin helmimyllyä ja jauhinkappaleina 2 mm:n lasihelmiä. Jauhautuvuutta tutkittiin analysoimalla tuotteiden partikkelikokojakaumat Beckman Coulter LS 13 320 partik-kelikokoanalysaattoria. Energiankulutukset määritettiin lietteen lämpötilan muutok-sen perusteella ensimmäisen viidentoista minuutin aikana. Työn tavoitteena oli selvittää, onko uusi lapamainen sekoitinelin tehokas jauhatta-vuuden kannalta mutta samalla myös energiatehokas. Tämän työn perusteella uusi lapamainen sekoitinelin on tehokas jauhautuvuuden kannalta suuremmilla pyörimis-nopeuksilla. Ominaisenergiankulutus on puolestaan samaa luokkaa suuremmilla pyö-rimisnopeuksilla verrattaessa eri sekoitinelimiä.
Resumo:
A new approach for the control of the size of particles fabricated using the Electrohydrodynamic Atomization (EHDA) method is being developed. In short, the EHDA process produces solution droplets in a controlled manner, and as the solvent evaporates from the surface of the droplets, polymeric particles are formed. By varying the voltage applied, the size of the droplets can be changed, and consequently, the size of the particles can also be controlled. By using both a nozzle electrode and a ring electrode placed axisymmetrically and slightly above the nozzle electrode, we are able to produce a Single Taylor Cone Single Jet for a wide range of voltages, contrary to just using a single nozzle electrode where the range of permissible voltage for the creation of the Single Taylor Cone Single Jet is usually very small. Phase Doppler Particle Analyzer (PDPA) test results have shown that the droplet size increases with increasing voltage applied. This trend is predicted by the electrohydrodynamic theory of the Single Taylor Cone Single Jet based on a perfect dielectric fluid model. Particles fabricated using different voltages do not show much change in the particles size, and this may be attributed to the solvent evaporation process. Nevertheless, these preliminary results do show that this method has the potential of providing us with a way of fine controlling the particles size using relatively simple method with trends predictable by existing theories.
Resumo:
In this study, the supercritical antisolvent with enhanced mass transfer method (SASEM) is used to fabricate micro and nanoparticles of biocompatible and biodegradable polymer PLGA (poly DL lactide co glycolic acid). This process may be extended to the encapsulation of drugs in these micro and nanoparticles for controlled release purposes. Conventional supercritical antisolvent (SAS) process involves spraying a solution (organic solvent + dissolved polymer) into supercritical fluid (CO[subscript 2]), which acts as an antisolvent. The high rate of mass transfer between organic solvent and supercritical CO[subscript 2] results in supersaturation of the polymer in the spray droplet and precipitation of the polymer as micro or nanoparticles occurs. In the SASEM method, ultrasonic vibration is used to atomize the solution entering the high pressure with supercritical CO[subscript 2]. At the same time, the ultrasonic vibration generated turbulence in the high pressure vessel, leading to better mass transfer between the organic solvent and the supercritical CO₂. In this study, two organic solvents, acetone and dichloromethane (DCM) were used in the SASEM process. Phase Doppler Particle Analyzer (PDPA) was used to study the ultrasonic atomization of liquid using the ultrasonic probe for the SASEM process. Scanning Electron Microscopy (SEM) was used to study the size and morphology of the polymer particles collected at the end of the process.
Resumo:
O presente trabalho teve por objetivos avaliar o espectro de gotas e os perfis de distribuição volumétrica de um bico hidráulico de jato plano de faixa expandida, modelo XR11003. Utilizou-se de analisador de partículas a laser para avaliar o espectro de gotas e de mesa de deposição para análise da distribuição volumétrica. O ensaio do espectro de gotas foi em delineamento inteiramente casualizado, em esquema fatorial 2 x 2 x 3, com três repetições, em que o primeiro fator representa o líquido pulverizado (L1 = água e L2 = água + 0,1% de espalhante adesivo não-iônico), o segundo representa a pressão de pulverização (P1 = 200 kPa e P2 = 400 kPa) e o terceiro representa três bicos hidráulicos XR11003 de jato plano (B1, B2 e B3). No ensaio de distribuição volumétrica, o delineamento foi o inteiramente casualizado, em esquema fatorial com dois fatores, não se avaliando o fator bico. Dos resultados do espectro de gotas, observaram-se maior tamanho de gotas para a pressão de 200 kPa e menor amplitude relativa quando se utilizou 0,1% de adjuvante. Para os perfis de distribuição volumétrica, ocorreu aumento na faixa de deposição e no espaçamento entre bicos com C.V. de 10%, com a adição de 0,1% de adjuvante e aumento na pressão.
Resumo:
Brazil has an important role in the biomass burning, with the detection of approximately 100,000 burning spots in a single year (2007). Most of these spots occur in the southern part of the Amazon basin during the dry season (from August to november) and these emissions reach the southeast of the country, a highly populated region and with serious urban air pollution problems. With the growing demand on biofuels, sugarcane is considerably expanding in the state of São Paulo, being a strong contributor to the bad air quality in this region. In the state of São Paulo, the main land use are pasture and sugarcane crop, that covers around 50% and 10% of the total area, respectively. Despite the aerosol from sugarcane burning having reduced atmospheric residence time, from a few days to some weeks, they might get together with those aerosol which spread over long distances (hundreds to thousands of kilometers). In the period of June through February 2010 a LIDAR observation campaign was carried in the state of São Paulo, Brazil, in order to observe and characterize optically the aerosols from two distinct sources, namely, sugar cane biomass burning and industrial emissions. For this purpose 2 LIDAR systems were available, one mobile and the other placed in a laboratory, both working in the visible (532 nm) and additionally the mobile system had a Raman channel available (607 nm). Also this campaign counted with a SODAR, a meteorological RADAR specially set up to detect aerosol echoes and gas-particle analyzers. To guarantee a good regional coverage 4 distinct sites were available to deploy the instruments, 2 in the near field of biomass burning activities (Rio Claro and Bauru), one for industrial emissions (Cubatão) and others from urban sources (São Paulo). The whole campaign provide the equivalent of 30 days of measurements which allowed us to get aerosol optical properties such as backscattering/extinction coefficients, scatter and LIDAR ratios, those were used to correlate with air quality and meteorological indicators and quantities. In this paper we should focus on the preliminary results of the Raman LIDAR system and its derived aerosol optical quantities. © 2010 Copyright SPIE - The International Society for Optical Engineering.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
The aim of this work was to evaluate the effect of the addition of different surfactants in physical and chemical properties of spray solutions, droplets spectra and drift potential on agricultural spraying. The surfactants and concentrations (v v-1) were: Haiten (0.1%), Antideriva and Intec (0.05% and 0.1%). The following characteristics were analyzed: surface tension, viscosity, density and electric conductivity. The droplet size spectrum was determined by a laser particle analyzer (Mastersizer S®, version 2.15) including measurements of volume medium diameter (VMD), the percent of droplets below 50 and 100 μm (V50 e V100) and index span. In order to estimate the drift potential, a series of wind tunnel tests were performed with a Teejet XR 8003 flat fan nozzle at 200 kPa (medium droplets) used to apply the spray solutions containing water, the adjuvants and a food color dye (Brilliant blue FD & C no 1) at 0,6% m v-1. The drift was collected on nylon strips transversally fixed along the tunnel at different distances from the nozzle and different high from the bottom part of the tunnel. Drift deposits were evaluated by spectrophotometry. The results showed that the addition of adjuvants changed physical and chemical properties of spray solutions in different magnitudes according to the surfactant. Surfactants changed the droplet spectrum and drift potential, indicating that higher VMD and smaller V100 induced higher percentage of drift.
Resumo:
SMPS and DMS500 analysers were used to measure particulate size distributions in the exhaust of a fully annular aero gas turbine engine at two operating conditions to compare and analyse sources of discrepancy. A number of different dilution ratio values were utilised for the comparative analysis, and a Dekati hot diluter operating at a temperature of 623°K was also utilised to remove volatile PM prior to measurements being made. Additional work focused on observing the effect of varying the sample line temperatures to ascertain the impact. Explanations are offered for most of the trends observed, although a new, repeatable event identified in the range from 417°K to 423°K – where there was a three order of magnitude increase in the nucleation mode of the sample – requires further study.
Resumo:
The diagnosis of Von Willebrand's disease (VWD) may sometimes be difficult because of the variability of the results obtained over time in individuals. Moreover, blood group, age, pregnancy and inflammatory stimuli influence the level of Von Willebrand Factor (VWF). The purpose of this thesis was to screen and characterize antibodies to Von Willebrand factor and to evaluate the most promising ones in a gold- Sol assay for VWF on the CA-6000 analyzer. Seven different lots of Anti-VWF antibodies, 3 polyclonal and 4 monoclonal Ab's were screened and evaluated. Two of these antibodies (Sunol R01358 and MAVWF-AP) were selected for preparation of a Gold coated antibody solution. The preliminary testing of these gold coated antibodies on CA-6000 Analyzer showed no immunoreactivity toward VWF for both individual and pooled plasma (from normal healthy donors). Although measurement of VWF for normal plasma with this technique was not demonstrated, these data will be valuable for future work on the design of sensitive and accurate automated sol Gold Immunoassays for the diagnosis of VWD.
Resumo:
Background: Urine is still the matrix of choice to fight against doping, because it can be collected non-invasively during anti-doping tests. Most of the World Anti-Doping Agency's accredited laboratories have more than 20 years experience in analyzing this biological fluid and the majority of the compounds listed in the 2010 Prohibited List - International Standard are eliminated through the urinary apparatus. Storing and transporting urine samples for doping analyses does not include a specific protocol to prevent microbial and thermal degradation. The use of a rapid and reliable screening method could enable determine reference intervals for urine specimens in doping control samples and evaluate notably the prevalence of microbial contamination known to be responsible for the degradation of chemical substances in urine.Methods: The Sysmex(R) UF-500i is a recent urine flow cytometer analyzer capable of quantifying BACT and other urinary particles such as RBC, WBC, EC, DEBRIS, CAST, PATH. CAST, YLC, SRC as well as measuring urine conductivity. To determine urine anti-doping reference intervals, 501 samples received in our laboratory over a period of two months were submitted to an immediate examination. All samples were collected and then transported at room temperature. Analysis of variance was performed to test the effects of factors such as gender, test type [in-competition, out-of-competition] and delivery time.Results: The data obtained showed that most of the urine samples were highly contaminated with bacteria. The other urine particles were also very different according to the factors.Conclusions: The Sysmex(R) UF-500i was capable of providing a snapshot of urine particles present in the samples at the time of the delivery to the laboratory. These particles, BACT in particular, gave a good idea of the possible microbial degradation which had and/or could have occurred in the sample. This information could be used as the first quality control set up in WADA (World Anti-Doping Agency) accredited laboratories to determine if steroid profiles, endogenous and prohibited substances have possibly been altered. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Raaka-aineen hiukkaskoko on lääkekehityksessä keskeinen materiaaliparametri. Lääkeaineen partikkelikoko vaikuttaa moneen lääketuotteen tärkeään ominaisuuteen, esimerkiksi lääkkeen biologiseen hyväksikäytettävyyteen. Tässä diplomityössä keskityttiin jauhemaisten lääkeaineiden hiukkaskoon määrittämiseen laserdiffraktiomenetelmällä. Menetelmä perustuu siihen, että partikkeleista sironneen valon intensiteetin sirontakulmajakauma on riippuvainen partikkelien kokojakaumasta. Työn kirjallisuusosassa esiteltiin laserdiffraktiomenetelmän teoriaa. PIDS (Polarization Intensity Differential Scattering) tekniikka, jota voidaan käyttää laserdiffraktion yhteydessä, on myös kuvattu kirjallisuusosassa. Muihin menetelmiin perustuvista analyysimenetelmistä tutustuttiin mikroskopiaan sekä aerodynaamisen lentoajan määrittämiseen perustuvaan menetelmään. Kirjallisuusosassa esiteltiin myös partikkelikoon yleisimpiä esitystapoja. Työn kokeellisen osan tarkoituksena oli kehittää ja validoida laserdiffraktioon perustuva partikkelikoon määritysmenetelmä tietylle lääkeaineelle. Menetelmäkehitys tehtiin käyttäen Beckman Coulter LS 13 320 laserdiffraktoria. Laite mahdollistaa PIDS-tekniikan käytön laserdiffraktiotekniikan ohella. Menetelmäkehitys aloitettiin arvioimalla, että kyseinen lääkeaine soveltuu parhaiten määritettäväksi nesteeseen dispergoituna. Liukoisuuden perusteella väliaineeksi valittiin tällä lääkeaineella kyllästetty vesiliuos. Dispergointiaineen sekä ultraäänihauteen käyttö havaittiin tarpeelliseksi dispergoidessa kyseistä lääkeainetta kylläiseen vesiliuokseen. Lopuksi sekoitusnopeus näytteensyöttöyksikössä säädettiin sopivaksi. Validointivaiheessa kehitetyn menetelmän todettiin soveltuvan hyvin kyseiselle lääkeaineelle ja tulosten todettiin olevan oikeellisia sekä toistettavia. Menetelmä ei myöskään ollut herkkä pienille häiriöille.
Resumo:
This technical report discusses the application of the Lattice Boltzmann Method (LBM) and Cellular Automata (CA) simulation in fluid flow and particle deposition. The current work focuses on incompressible flow simulation passing cylinders, in which we incorporate the LBM D2Q9 and CA techniques to simulate the fluid flow and particle loading respectively. For the LBM part, the theories of boundary conditions are studied and verified using the Poiseuille flow test. For the CA part, several models regarding simulation of particles are explained. And a new Digital Differential Analyzer (DDA) algorithm is introduced to simulate particle motion in the Boolean model. The numerical results are compared with a previous probability velocity model by Masselot [Masselot 2000], which shows a satisfactory result.
Resumo:
We present the observations of energetic neutral atoms (ENAs) produced at the lunar surface in the Earth's magnetotail. When the Moon was located in the terrestrial plasma sheet, Chandrayaan-1 Energetic Neutrals Analyzer (CENA) detected hydrogen ENAs from the Moon. Analysis of the data from CENA together with the Solar Wind Monitor (SWIM) onboard Chandrayaan-1 reveals the characteristic energy of the observed ENA energy spectrum (the e-folding energy of the distribution function) ∼100 eV and the ENA backscattering ratio (defined as the ratio of upward ENA flux to downward proton flux) <∼0.1. These characteristics are similar to those of the backscattered ENAs in the solar wind, suggesting that CENA detected plasma sheet particles backscattered as ENAs from the lunar surface. The observed ENA backscattering ratio in the plasma sheet exhibits no significant difference in the Southern Hemisphere, where a large and strong magnetized region exists, compared with that in the Northern Hemisphere. This is contrary to the CENA observations in the solar wind, when the backscattering ratio drops by ∼50% in the Southern Hemisphere. Our analysis and test particle simulations suggest that magnetic shielding of the lunar surface in the plasma sheet is less effective than in the solar wind due to the broad velocity distributions of the plasma sheet protons.