998 resultados para Particle accelerators
Resumo:
201 p.
Resumo:
Recent vacuum system development with an XHV condition for the particle accelerators is briefly described. The progress of selecting and treatment of the materials used in XHV systems is introduced, and the choice of the main pump for an XHV system and some new pumping method are presented. Some leak detection experiences both for the superconducting and warm vacuum systems are recommended and the status of XHV measurement and the gauge calibration are introduced.
Resumo:
To know how much misalignment is tolerable for a particle accelerator is an important input for the design of these machines. In particle accelerators the beam must be guided and focused using bending magnets and magnetic lenses, respectively. The alignment of the lenses along a transport line aims to ensure that the beam passes through their optical axes and represents a critical point in the assembly of the machine. There are more and more accelerators in the world, many of which are very small machines. Because the existing literature and programs are mostly targeted for large machines. in this work we describe a method suitable for small machines. This method consists in determining statistically the alignment tolerance in a set of lenses. Differently from the methods used in standard simulation codes for particle accelerators, the statistical method we propose makes it possible to evaluate particle losses as a function of the alignment accuracy of the optical elements in a transport line. Results for 100 key electrons, on the 3.5-m long conforming beam stage of the IFUSP Microtron are presented as an example of use. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Optical transition radiation (OTR) plays an important role in beam diagnostics for high energy particle accelerators. Its linear intensity with beam current is a great advantage as compared to fluorescent screens, which are subject to saturation. Moreover, the measurement of the angular distribution of the emitted radiation enables the determination of many beam parameters in a single observation point. However, few works deals with the application of OTR to monitor low energy beams. In this work we describe the design of an OTR based beam monitor used to measure the transverse beam charge distribution of the 1.9-MeV electron beam of the linac injector of the IFUSP microtron using a standard vision machine camera. The average beam current in pulsed operation mode is of the order of tens of nano-Amps. Low energy and low beam current make OTR observation difficult. To improve sensitivity, the beam incidence angle on the target was chosen to maximize the photon flux in the camera field-of-view. Measurements that assess OTR observation (linearity with beam current, polarization, and spectrum shape) are presented, as well as a typical 1.9-MeV electron beam charge distribution obtained from OTR. Some aspects of emittance measurement using this device are also discussed. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4748519]
Resumo:
In this work, the well-known MC code FLUKA was used to simulate the GE PETrace cyclotron (16.5 MeV) installed at “S. Orsola-Malpighi” University Hospital (Bologna, IT) and routinely used in the production of positron emitting radionuclides. Simulations yielded estimates of various quantities of interest, including: the effective dose distribution around the equipment; the effective number of neutron produced per incident proton and their spectral distribution; the activation of the structure of the cyclotron and the vault walls; the activation of the ambient air, in particular the production of 41Ar, the assessment of the saturation yield of radionuclides used in nuclear medicine. The simulations were validated against experimental measurements in terms of physical and transport parameters to be used at the energy range of interest in the medical field. The validated model was also extensively used in several practical applications uncluding the direct cyclotron production of non-standard radionuclides such as 99mTc, the production of medical radionuclides at TRIUMF (Vancouver, CA) TR13 cyclotron (13 MeV), the complete design of the new PET facility of “Sacro Cuore – Don Calabria” Hospital (Negrar, IT), including the ACSI TR19 (19 MeV) cyclotron, the dose field around the energy selection system (degrader) of a proton therapy cyclotron, the design of plug-doors for a new cyclotron facility, in which a 70 MeV cyclotron will be installed, and the partial decommissioning of a PET facility, including the replacement of a Scanditronix MC17 cyclotron with a new TR19 cyclotron.
Resumo:
This Habilitationsschrift (Habilitation thesis) is focused on my research activities on medical applications of particle physics and was written in 2013 to obtain the Venia Docendi (Habilitation) in experimental physics at the University of Bern. It is based on selected publications, which represented at that time my major scientific contributions as an experimental physicist to the field of particle accelerators and detectors applied to medical diagnostics and therapy. The thesis is structured in two parts. In Part I, Chapter 1 presents an introduction to accelerators and detectors applied to medicine, with particular focus on cancer hadrontherapy and on the production of radioactive isotopes. In Chapter 2, my publications on medical particle accelerators are introduced and put into their perspective. In particular, high frequency linear accelerators for hadrontherapy are discussed together with the new Bern cyclotron laboratory. Chapter 3 is dedicated to particle detectors with particular emphasis on three instruments I contributed to propose and develop: segmented ionization chambers for hadrontherapy, a proton radiography apparatus with nuclear emulsion films, and a beam monitor detector for ion beams based on doped silica fibres. Selected research and review papers are contained in Part II. For copyright reasons, they are only listed and not reprinted in this on-line version. They are available on the websites of the journals.
Resumo:
A particle accelerator is any device that, using electromagnetic fields, is able to communicate energy to charged particles (typically electrons or ionized atoms), accelerating and/or energizing them up to the required level for its purpose. The applications of particle accelerators are countless, beginning in a common TV CRT, passing through medical X-ray devices, and ending in large ion colliders utilized to find the smallest details of the matter. Among the other engineering applications, the ion implantation devices to obtain better semiconductors and materials of amazing properties are included. Materials supporting irradiation for future nuclear fusion plants are also benefited from particle accelerators. There are many devices in a particle accelerator required for its correct operation. The most important are the particle sources, the guiding, focalizing and correcting magnets, the radiofrequency accelerating cavities, the fast deflection devices, the beam diagnostic mechanisms and the particle detectors. Most of the fast particle deflection devices have been built historically by using copper coils and ferrite cores which could effectuate a relatively fast magnetic deflection, but needed large voltages and currents to counteract the high coil inductance in a response in the microseconds range. Various beam stability considerations and the new range of energies and sizes of present time accelerators and their rings require new devices featuring an improved wakefield behaviour and faster response (in the nanoseconds range). This can only be achieved by an electromagnetic deflection device based on a transmission line. The electromagnetic deflection device (strip-line kicker) produces a transverse displacement on the particle beam travelling close to the speed of light, in order to extract the particles to another experiment or to inject them into a different accelerator. The deflection is carried out by the means of two short, opposite phase pulses. The diversion of the particles is exerted by the integrated Lorentz force of the electromagnetic field travelling along the kicker. This Thesis deals with a detailed calculation, manufacturing and test methodology for strip-line kicker devices. The methodology is then applied to two real cases which are fully designed, built, tested and finally installed in the CTF3 accelerator facility at CERN (Geneva). Analytical and numerical calculations, both in 2D and 3D, are detailed starting from the basic specifications in order to obtain a conceptual design. Time domain and frequency domain calculations are developed in the process using different FDM and FEM codes. The following concepts among others are analyzed: scattering parameters, resonating high order modes, the wakefields, etc. Several contributions are presented in the calculation process dealing specifically with strip-line kicker devices fed by electromagnetic pulses. Materials and components typically used for the fabrication of these devices are analyzed in the manufacturing section. Mechanical supports and connexions of electrodes are also detailed, presenting some interesting contributions on these concepts. The electromagnetic and vacuum tests are then analyzed. These tests are required to ensure that the manufactured devices fulfil the specifications. Finally, and only from the analytical point of view, the strip-line kickers are studied together with a pulsed power supply based on solid state power switches (MOSFETs). The solid state technology applied to pulsed power supplies is introduced and several circuit topologies are modelled and simulated to obtain fast and good flat-top pulses.
Resumo:
Abstracts in English.
Resumo:
"AEC Contract AT(04-3)-400."
Resumo:
"European Organization for Nuclear Research."
Resumo:
"March 1965."
Resumo:
In technicolor theories the scalar sector of the Standard Model is replaced by a strongly interacting sector. Although the Standard Model has been exceptionally successful, the scalar sector causes theoretical problems that make these theories seem an attractive alternative. I begin my thesis by considering QCD, which is the known example of strong interactions. The theory exhibits two phenomena: confinement and chiral symmetry breaking. I find the low-energy dynamics to be similar to that of the sigma models. Then I analyze the problems of the Standard Model Higgs sector, mainly the unnaturalness and triviality. Motivated by the example of QCD, I introduce the minimal technicolor model to resolve these problems. I demonstrate the minimal model to be free of anomalies and then deduce the main elements of its low-energy particle spectrum. I find the particle spectrum contains massless or very light technipions, and also technibaryons and techni-vector mesons with a high mass of over 1 TeV. Standard Model fermions remain strictly massless at this stage. Thus I introduce the technicolor companion theory of flavor, called extended technicolor. I show that the Standard Model fermions and technihadrons receive masses, but that they remain too light. I also discuss flavor-changing neutral currents and precision electroweak measurements. I then show that walking technicolor models partly solve these problems. In these models, contrary to QCD, the coupling evolves slowly over a large energy scale. This behavior adds to the masses so that even the light technihadrons are too heavy to be detected at current particle accelerators. Also all observed masses of the Standard Model particles can be generated, except for the bottom and top quarks. Thus it is shown in this thesis that, excluding the masses of third generation quarks, theories based on walking technicolor can in principle produce the observed particle spectrum.
Resumo:
179 p.
Resumo:
The past few years have seen remarkable progress in the development of laser-based particle accelerators. The ability to produce ultrabright beams of multi-megaelectronvolt protons routinely has many potential uses from engineering to medicine, but for this potential to be realized substantial improvements in the performances of these devices must be made. Here we show that in the laser-driven accelerator that has been demonstrated experimentally to produce the highest energy protons, scaling laws derived from fluid models and supported by numerical simulations can be used to accurately describe the acceleration of proton beams for a large range of laser and target parameters. This enables us to evaluate the laser parameters needed to produce high-energy and high-quality proton beams of interest for radiography of dense objects or proton therapy of deep-seated tumours.
Resumo:
Overdense plasmas are usually opaque to laser light. However, when the light is of sufficient intensity to drive electrons in the plasma to near light speeds, the plasma becomes transparent. This process—known as relativistic transparency—takes just a tenth of a picosecond. Yet all studies of relativistic transparency so far have been restricted to measurements collected over timescales much longer than this, limiting our understanding of the dynamics of this process. Here we present time-resolved electric field measurements (with a temporal resolution of ~ 50 fs) of the light, initially reflected from, and subsequently transmitted through, an expanding overdense plasma. Our result provides insight into the dynamics of the transparent-overdense regime of relativistic plasmas, which should be useful in the development of laser-driven particle accelerators, X-ray sources and techniques for controlling the shape and contrast of intense laser pulses.