234 resultados para Paralisação da aeração


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cassava wastewater, generated during the cassava processing, is a pollutant and toxic waste. This study compared the efficiency of the cassava wastewater treatment in three batch aerobic systems with a ru1nning time of 24 hours, and aeration stoppage of 12h with 2,500, 6,000 and 10,000 mg COD L-1 . The systems were evaluated for COD, pH, SVI and F/M. The results showed that the reactor with aeration stoppage for 12 hours, with 2,500 mg COD L-1 , presented the best reduction in a process with considerable energy consumption saving compared to traditional continuous systems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Cassava wastewater, generated during cassava processing, is a highly polluting and toxic waste. This study aimed to assess the relationship of cassava treatment efficiency in two aerobic sequencing batch reactors, cylindrical plastics (31cm height x 9cm diameter), with 2.0 liters capacity and 1.5 liters of work volume, a ratio of diameter and height of the liquid 1:2.5, with a running time of 24 hours and stoppage aeration for 16 hours with average feed of 2,500 and 6,000 mg COD. L -1. COD, pH, SVI and F/M were analyzed. The results obtained in the two reactors showed an average reduction of 94.1% and 76.8% organic content, respectively; pH values showed a rising in the output pH values compared to entry ones; SVI values obtained: 54.1 mL/g, 99.3 mL/g, respectively in a F/M ratio values worked out of 0.4 d-1 and 1,1 d-1 , respectively. The results demonstrated that the process has generated considerable saving in energy consumption compared to traditional continuous systems, was efficient and did not affect the efficiency overly of the reactor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho, de caráter exploratório, foi motivado pelo fato de que nas últimas safras agrícolas, em muitas áreas cultivadas com soja, ocorreu um alto índice de mortalidade de plântulas de soja, que inicialmente apresentavam lesão na extremidade da raiz principal, seguida por infecção causada por fungos normalmente encontrados no solo. Em avaliações preliminares, constatou-se que a maior incidência de morte de plântulas ocorreu principalmente nos solos de menor profundidade efetiva originados do basalto, pois, aproximadamente 70% dos problemas ocorreram nas terras roxas (nitrossolos) e nos cambissolos e litossolos (neossolos). Somente 30% das ocorrências foram verificadas nos latossolos que são solos bem desenvolvidos, profundos e apresentam boa drenagem. Além dessas características de solo favoráveis à morte de plântulas, o relevo bastante ondulado e o manejo inadequado dessas áreas, com uso intensivo de implementos nos últimos 20 anos, podem também favorecer morte de plântulas. São também descritos nesse documento os sintomas da morte de plântulas, a caracterização e manejo dos solos, além do manejo da cultura de soja como causas prováveis do problema. A influência do ano, bem como alguns estudos de caso em propriedades onde apareceu a morte de plântulas e as estratégias para enfrentar a situação são também consideradas nesse documento. Como a maioria das informações foi obtida empiricamente, a partir de observações de ocorrência a campo, não foi possível gerar informações conclusivas, mas somente aquelas que ajudam na tomada de decisão de como melhorar a tecnologia de cultivo da soja nas áreas afetadas pelo problema e, com isso, diminuir os riscos de novas perdas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A qualidade da água é muito importante para irrigação por gotejamento, pois ela escoa por pequenos bocais dos emissores, podendo ocorrer obstrução devido à deposição dos sólidos em suspensão. Portanto, antes da instalação do projeto, devem-se avaliar parâmetros de qualidade da água, para adotar medidas preventivas, evitando o risco de entupimento do sistema. Este trabalho teve como objetivo avaliar um sistema composto por aeradores com aspersores, sobre leito de pedra, para a precipitação dos íons Fe+2e Mn+2 em tanque de decantação, e um conjunto de filtragem composto por três filtros de areia e um de disco, em sistema de irrigação localizada. O trabalho foi realizado na Fazenda Alvorada, no município de Nova Granada - SP, no período de março a outubro de 2008. Foram realizadas determinações de variáveis físicas e químicas da água, ao longo do sistema de aeração, decantação e filtragem, o qual foi eficiente para a melhoria da qualidade de água, reduzindo os níveis de risco de entupimento de severo para médio e de médio para baixo. Oxigênio dissolvido, condutividade elétrica, pH, Fe+2e Fe+3 não diferenciaram a qualidade de água entre os pontos do sistema de tratamento, porém a turbidez, sólidos dissolvidos, sólidos em suspensão, ferro total e manganês total reduziram-se significativamente pelo uso do sistema proposto, melhorando a qualidade da água.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In wastewater treatment, activated sludge systems have been a technology widely applied as secondary treatment. During this step, which has a strong biological aspect, it is necessary to introduce oxygen supply for the maintenance of metabolic activity of the bacteria through the aerators. Aeration devices are responsible for most of the energy consumption in this stage. In this background, the influence of three aeration intensities (atmospheric air flow 3.5, 7.0 and 10.5 L.min-1) and the concentration of dissolved oxygen (DO) on the dimension of activated sludge flocs as well as on the efficiency of organic matter removal were assessed using a traditional activated sludge system which was fed with synthetic domestic wastewater. Samples were taken weekly from the three units that make up the system feed, aeration and storage tank in order to verify the Chemical Oxygen Demand (COD). It was established the process efficiency through a comparison between the initial and final COD. Besides the parameters already mentioned, this monitoring work on activated sludge batch system was also observed by Mixed Liquor Suspend Solids (MLSS), Volatile Suspend Solids (VSS), pH and temperature measures. The results have showed a maximum removal efficiency around 75% in the first aeration sequence and approximately 85% for the second and third one. For the first aeration, the DO concentration remained higher than 3.0 mg.L-1 and a diameter range from 10 to 60 μm was observed. In the second e third sequence, the DO concentration remained higher than 4.0 mg.L-1 with a diameter range of 10 until 200 μm. Although the sequence 1 and 2 have presented similar performances for organic matter removal, the sequence 2 promoted a regular floc size distribution and with lower values of Sludge Volumetric Index (SVI) meaning a better flocculating ability. In addition, the results reaffirmed what the literature has reported: higher DO concentrations produce flocs with greater dimensions

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dental caries consists in a multifactorial and dynamic process. The knowledge of the ionic interactions among dental tissues and dental biofilm make possible its understanding as a process that can be stopped. Recently, the use of sealants have lost its function as preventive agent and passed to be argued as a possible therapeutical agent. This happens by hindering the substratum flow to the lesion inner and, therefore, controls the advance of the process. This study aimed to evaluate glass ionomer cement as a not invasive technique of treatment in occlusal caries without clinical cavitation, but with dentinal involvement. The research was accomplished using a controlled clinical trial with two groups (experimental and control) in 38 subjects (8-18 years) with 51 molars. The teeth of the experimental group were sealed with glass ionomer cement (Vidrion-R, S.S.White, Juiz de Fora, Brazil) and the molars control did not suffer intervention. The experimental group was followed by a year and the control by 8 months due the progression of the carious injury. Both groups were reevaluated to each 4 months with the use of clinical, radiographic and laser fluorescence (DIAGNOdent®) examination. The analysis of the clinical evaluation did not observe a significant difference between experimental and control groups. However, analysis with radiographic and laser fluorescence (DIAGNOdent®) examination observed a significant difference (p> 0,05) between groups, demonstrating a wors condition to the group without intervention. The results suggest that glass ionomer cement as sealant can be efficient to paralyze dentinal caries without clinical cavitation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)