8 resultados para Panna


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis focuses on tectonic geomorphology and the response of the Ken River catchment to postulated tectonic forcing along a NE-striking monocline fold in the Panna region, Madhya Pradesh, India. Peninsular India is underlain by three northeast-trending paleotopographic ridges of Precambrian Indian basement, bounded by crustal-scale faults. Of particular interest is the Pokhara lineament, a crustal scale fault that defines the eastern edge of the Faizabad ridge, a paleotopographic high cored by the Archean Bundelkhand craton. The Pokhara lineament coincides with the monocline structure developed in the Proterozoic Vindhyan Supergroup rocks along the Bundelkhand cratonic margin. A peculiar, deeply incised meander-like feature, preserved along the Ken River where it flows through the monocline, may be intimately related to the tectonic regime of this system. This thesis examines 41 longitudinal stream profiles across the length of the monocline structure to identify any tectonic signals generated from recent surface uplift above the Pokhara lineament. It also investigates the evolution of the Ken River catchment in response to the generation of the monocline fold. Digital Elevation Models (DEM) from Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) were used to delineate a series of tributary watersheds and extract individual stream profiles which were imported into MATLAB for analysis. Regression limits were chosen to define distinct channel segments, and knickpoints were defined at breaks between channel segments where there was a discrete change in the steepness of the channel profile. The longitudinal channel profiles exhibit the characteristics of a fluvial system in transient state. There is a significant downstream increase in normalized steepness index in the channel profiles, as well as a general increase in concavity downstream, with some channels exhibiting convex, over-steepened segments. Normalized steepness indices and uppermost knickpoint elevations are on average much higher in streams along the southwest segment of the monocline compared to streams along the northeast segment. Most channel profiles have two to three knickpoints, predominantly exhibiting slope-break morphology. These data have important implications for recent surface uplift above the Pokhara lineament. Furthermore, geomorphic features preserved along the Ken River suggest that it is an antecedent river. The incised meander-like feature appears to be the abandoned river valley of a former Ken River course that was captured during the evolution of the landscape by what is the present day Ken River.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At head of title: Kazimierz Przerwa-Tetmajer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis focuses on tectonic geomorphology and the response of the Ken River catchment to postulated tectonic forcing along a NE-striking monocline fold in the Panna region, Madhya Pradesh, India. Peninsular India is underlain by three northeast-trending paleotopographic ridges of Precambrian Indian basement, bounded by crustal-scale faults. Of particular interest is the Pokhara lineament, a crustal scale fault that defines the eastern edge of the Faizabad ridge, a paleotopographic high cored by the Archean Bundelkhand craton. The Pokhara lineament coincides with the monocline structure developed in the Proterozoic Vindhyan Supergroup rocks along the Bundelkhand cratonic margin. A peculiar, deeply incised meander-like feature, preserved along the Ken River where it flows through the monocline, may be intimately related to the tectonic regime of this system. This thesis examines 41 longitudinal stream profiles across the length of the monocline structure to identify any tectonic signals generated from recent surface uplift above the Pokhara lineament. It also investigates the evolution of the Ken River catchment in response to the generation of the monocline fold. Digital Elevation Models (DEM) from Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) were used to delineate a series of tributary watersheds and extract individual stream profiles which were imported into MATLAB for analysis. Regression limits were chosen to define distinct channel segments, and knickpoints were defined at breaks between channel segments where there was a discrete change in the steepness of the channel profile. The longitudinal channel profiles exhibit the characteristics of a fluvial system in transient state. There is a significant downstream increase in normalized steepness index in the channel profiles, as well as a general increase in concavity downstream, with some channels exhibiting convex, over-steepened segments. Normalized steepness indices and uppermost knickpoint elevations are on average much higher in streams along the southwest segment of the monocline compared to streams along the northeast segment. Most channel profiles have two to three knickpoints, predominantly exhibiting slope-break morphology. These data have important implications for recent surface uplift above the Pokhara lineament. Furthermore, geomorphic features preserved along the Ken River suggest that it is an antecedent river. The incised meander-like feature appears to be the abandoned river valley of a former Ken River course that was captured during the evolution of the landscape by what is the present day Ken River.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Sweden, there are about 0.5 million single-family houses that are heated by electricity alone, and rising electricity costs force the conversion to other heating sources such as heat pumps and wood pellet heating systems. Pellet heating systems for single-family houses are currently a strongly growing market. Future lack of wood fuels is possible even in Sweden, and combining wood pellet heating with solar heating will help to save the bio-fuel resources. The objectives of this thesis are to investigate how the electrically heated single-family houses can be converted to pellet and solar heating systems, and how the annual efficiency and solar gains can be increased in such systems. The possible reduction of CO-emissions by combining pellet heating with solar heating has also been investigated. Systems with pellet stoves (both with and without a water jacket), pellet boilers and solar heating have been simulated. Different system concepts have been compared in order to investigate the most promising solutions. Modifications in system design and control strategies have been carried out in order to increase the system efficiency and the solar gains. Possibilities for increasing the solar gains have been limited to investigation of DHW-units for hot water production and the use of hot water for heating of dishwashers and washing machines via a heat exchanger instead of electricity (heat-fed appliances). Computer models of pellet stoves, boilers, DHW-units and heat-fed appliances have been developed and the parameters for the models have been identified from measurements on real components. The conformity between the models and the measurements has been checked. The systems with wood pellet stoves have been simulated in three different multi-zone buildings, simulated in detail with heat distribution through door openings between the zones. For the other simulations, either a single-zone house model or a load file has been used. Simulations were carried out for Stockholm, Sweden, but for the simulations with heat-fed machines also for Miami, USA. The foremost result of this thesis is the increased understanding of the dynamic operation of combined pellet and solar heating systems for single-family houses. The results show that electricity savings and annual system efficiency is strongly affected by the system design and the control strategy. Large reductions in pellet consumption are possible by combining pellet boilers with solar heating (a reduction larger than the solar gains if the system is properly designed). In addition, large reductions in carbon monoxide emissions are possible. To achieve these reductions it is required that the hot water production and the connection of the radiator circuit is moved to a well insulated, solar heated buffer store so that the boiler can be turned off during the periods when the solar collectors cover the heating demand. The amount of electricity replaced using systems with pellet stoves is very dependant on the house plan, the system design, if internal doors are open or closed and the comfort requirements. Proper system design and control strategies are crucial to obtain high electricity savings and high comfort with pellet stove systems. The investigated technologies for increasing the solar gains (DHW-units and heat-fed appliances) significantly increase the solar gains, but for the heat-fed appliances the market introduction is difficult due to the limited financial savings and the need for a new heat distribution system. The applications closest to market introduction could be for communal laundries and for use in sunny climates where the dominating part of the heat can be covered by solar heating. The DHW-unit is economical but competes with the internal finned-tube heat exchanger which is the totally dominating technology for hot water preparation in solar combisystems for single-family houses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

SP i Borås och SERC, Högskolan Dalarna har i samverkan tagit fram en systemprovnings-metod där kompletta sol- och pelletsvärmesystem har provats i laboratorium under sex dygn. Plus två inledande dygn för termisk stabilisering av systemet. Provningen innefattar verklig-hetstrogna lastfall för två sommardagar, två vinterdagar, och två vår/höstdagar. Syftet är att få fram information om systemets helårsprestanda och systemfunktion genom en kortare tids provning. Vid mätningarna som genomförts vid Högskolan Dalarna har syftet också varit att undersöka systemens emissionsprestanda. Emissionsmätningarna ingår normalt inte i system-provningen, eftersom det skulle öka kostnaderna för att genomföra proven. Ett komplett system inklusive regulatorer provas med undantag för solfångaren, som utgörs av en dator-styrd rigg för att kunna skapa en repeterbar solvärmemängd från en systemspecifik solfångar-krets.Totalt har sju olika sol-pelletsystem provats samt ett referenssystem som utgörs av en kombi-panna utan solvärme. Dessutom har det inom projektet genomförts en jämförande provning mellan SP och Högskolan Dalarna på samma system. Provningsmetoden som utvecklats i detta projekt har visat sig kunna uppfylla målen, det vill säga kunna jämföra systemprestanda mellan olika system och uppskatta årsprestandan. Till detta har även eventuella driftsproblem i systemen kunnat identifieras så att dessa kan åtgärdas och systemen förbättras. För att förbättra provningsmetoden och öka noggrannheten i utvärderingen föreslås ett antal åtgärder inför en fortsatt provning. De viktigaste förändringarna är att se till att pannans och systemets laddstatus är så lika som möjligt vid början av sexdagarssekvensen, liksom vid sekvensens slut. Detta kräver två olika åtgärder: dels att de inledande två dygnen är identiska med de sista två dygnen och att panna triggas igång ett par timmar innan sekvensens början och slut, så att risken minskar att pannan levererar värme till tanken vid sekvensens början och slut. Vidare föreslås att en ny metod skall användas för att mäta värmeavgivningen till rummet från kaminer och att dess noggrannhet undersöks.För att åstadkomma exakt rätt last och solvärmetillskott vid provningen skall riggen använda en teknik med kontinuerlig kompensation av last och solvärmetillskott så att uppmätt och önskad energimängd alltid blir densamma i alla provningar. Detta förenklar även handhavan-det vid provningen och underlättar utvärderingen. För att kunna ge bättre återkoppling och kunna ge råd till hur systemen skall förbättras bör tanktemperaturen alltid mätas i några punk-ter och att förlustkoefficienter för panna och tank tas fram genom ett separat avsvalningsprov.Systemprovningen visar generellt att det är gynnsamt att kombinera pelleteldning med sol-värme. Pelletpannor har en låg verkningsgrad under låglastperioden och med solvärme kan pannan stängas av när driftsförutsättningarna är som sämst. Hög pannverkningsgrad liksom en väl fungerande ackumulatortank och styrsystem har visat sig vara avgörande för att erhålla höga systemprestanda i denna provningsmetod. Pannverk-ningsgraden över mätperioden är betydligt lägre än för motsvarande pannor under stationär drift på full effekt. Detta beror på att driftstiden för brännaren endast utgör en liten del av hela provningsperioden och därför blir pannans egenskaper under stilleståndsperioderna desto viktigare för systemets prestanda. Under stilleståndsperioderna är det värmeförlusterna till rummet som är avgörande för prestandan, medan värmeförlusterna har en försumbar inverkan på verkningsgraden när pannan eldas på full effekt enligt provningsmetoden för pannor EN 303-5. Resultaten pekar alltså på att de normala prestandaprovningarna för pannor enligt EN 303-5 inte ger någon garanti för att pannan är effektiv under verklighetstrogen drift och att provning vid stationär effekt inte heller styr utvecklingen mot bättre isolerade pannor och därmed effektivare sol- och biovärmesystem.Solfångarens prestanda och storlek har också relativt liten inverkan på den totala systempres-tandan. Solfångarprovning som garanterar solfångarens prestanda är viktigt för att garantera solfångarnas kvalitet och prestanda, men alltså inte på något sätt avgörande för att uppnå höga årsprestanda i kombinerade sol- och biobränslesystem Det finns uppenbarligen en stor förbätt-ringspotential för denna typ av system och den utvecklade provmetoden är ett mycket viktigt redskap för att effektivisera sol- och biovärmesystem.Emissionsfaktorer redovisade som medelvärde för hela provningssekvensen (sex dygn) var mellan 192 och 547 mg/MJ för CO, mellan 61 och 95 mg/MJ för NO, mellan 6 och 45 mg/MJ för TOC och mellan 31 och 116 mg/MJ för partiklar. För CO och NO ligger värdena inom de intervall som redovisas från forskningsprogrammet "biobränsle hälsa och miljö BHM. Upp-mätt medelkoncentration av kolväten och partiklar ligger betydligt högre än de emissionsfak-torer som redovisas av BHM.Andelen av emissionerna som släpps ut under start/stopp sekvenserna ligger mellan 63 och 96 % för CO-utsläppen och mellan 48 och 93 % av TOC-utsläppen. För partiklar är motsvarande andel mellan 30 och 39 % och för NO endast 10 till 21 %. Det betyder att styrningen av brän-naren och emissionskarakteristiken under start/stopp-blir mycket avgörande för hur mycket CO och TOC som släpps ut och att nuvarande metoder för miljömärkning av pelletpannor som baseras på stationära mätningar enligt EN 303-5 inte leder till att emissioner av CO och TOC minimeras på årsbasis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vol. 19 has imprint: Bhopal : District Gazetteers Dept., Madhya Pradesh.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Kutatásunkban egyedi, fatörzsön mért nedváramlási adatokra támaszkodva megvizsgáltuk, hogy hogyan változik a vízfelvétel mértéke intenzív módon művelt, sűrű ültetésű cseresznyeültetvényben. Számításokat végeztünk a fák és az ültetvény egészének vízfogyasztására vonatkozóan, a vegetációs időszak bizonyos hónapjaira. Kiszámítottuk, hogy helyi körülmények között hogyan változik a haszonnövény transzspirációs index értéke korai érésű, intenzív cseresznyeültetvényre. A nedváramlás és a légköri viszonyok – mint külső vezérlő tényezők – között fennálló kapcsolatrendszer megismeréséhez a hőmérséklettel, a globálsugárzással, a telítési hiánnyal és a széllel való kapcsolatot vizsgáltuk. Méréseinket a Budapesti Corvinus Egyetem Soroksári Kísérleti Üzem és Tangazdaságában végeztük 2008-tól 2011-ig a vegetációs időszakokban.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A fafajok megválasztása döntő jelentőségű az energiatermelő faültetvény tervezésénél, mert csak a termőhelynek megfelelő, gyorsan növő, nagy produkciójú fafajok és fajták jöhetnek számításba. A fajta és termőhelyi kérdések tisztázása érdekében 2011 tavaszán a tangazdaság soroksári területén mintegy 1500 m2-en kísérleti ültetvényt hoztunk létre 5 fűz és 9 nyárfajtával, ill. egyéb kontroll fajtákkal. Vizsgáltuk ezek növekedési erélyét valamint a termőhely talajtani és klimatikus adottságait, továbbá a technológiát és hatékonyságot.