995 resultados para Paired serology


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A serological study was carried out to evaluate the causal relationship of acute diarrhoea and rotavirus in children under five years of age. The rotaviral infection was demonstrated in paired sera by determining the antibody titers by immunofluorescence test (IF). Bovine rotavirus-infected MA-104 cell culture was used as substratum for IF. Out of 80 paired sera it was shown that 23 (28.75%) presented seroconversion, 19 (23.75%) samples showed a twofold increase in their titers and 38 (47.5%) had no increase in rotavirus antibody. This result is discussed on the light of previously obtained results on viral antigen detection by counterimmunoelectrosmophoresis (CIEOP).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION: The aim of this study was to determinate the incidence of congenital toxoplasmosis among a group of newborns (NBs) from Belém using neonatal screening. METHODS: Among the 6,000 newborns referred for investigation of genetic and metabolic diseases, 1,000 were selected for screening for congenital toxoplasmosis by determining the amount of IgM in the eluates of blood collected on filter paper. Positive tests were confirmed using paired serology of the NB and his mother. RESULTS: Out of the 1,000 NBs assessed, one had a positive screening result that was confirmed by paired serology. CONCLUSIONS: The incidence of congenital toxoplasmosis in Belém was 10/10,000 live NBs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Positive serological tests for hepatitis viruses B and C at blood banks are an important reason for blood deferral. Additionally, high residual risk for transfusing hepatitis-contaminated blood has been estimated in southern Brazil. This study aimed to identify risk factors for positive serological tests for viral hepatitis (VH) in blood donors (BD). METHODS: A case-control study included consecutive BD with positive serology for VH, between 2008 and 2009. Cases and controls (BD with negative serology for VH) were paired 1:1 by sex and donation date. Assessment of clinical and epidemiological characteristics related to viral hepatitis was conducted. RESULTS: Among 1,282 blood donors (641 cases and 641 controls), those with positive serology for viral hepatitis had higher mean age (p<0.001); higher proportion of replacement donation (p<0.001); first donation (p<0.001); and interviewer deferment (p=0.037), compared to controls. Furthermore, donors with positive tests were less regular donors (p<0.001), had less previous history of rejection (p=0.003) and showed lower hematocrit median before donation (p=0.019). Multivariate analysis demonstrated that age (OR=1.056, 95%CI 1.042-1.069, p<0.001), replacement donation (OR=1.545, 95%CI 1.171-2.038, p=0.002) and first donation (OR=9.931, 95%CI 7.486-13.173, p<0.001) were independently associated with positivity of serological tests for viral hepatitis. CONCLUSIONS: Specific characteristics of blood donors were associated with positive serology for viral hepatitis. These peculiarities should be taken into account when assessing candidates for blood donation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the osseointegration properties of prototyped implants with tridimensionally interconnected pores made of the Ti6Al4V alloy and the influence of a thin calcium phosphate coating. Bilateral critical size calvarial defects were created in thirty Wistar rats and filled with coated and uncoated implants in a randomized fashion. The animals were kept for 15, 45 and 90 days. Implant mechanical integration was evaluated with a push-out test. Bone-implant interface was analyzed using scanning electron microscopy. The maximum force to produce initial displacement of the implants increased during the study period, reaching values around 100N for both types of implants. Intimate contact between bone and implant was present, with progressive bone growth into the pores. No significant differences were seen between coated and uncoated implants. Adequate osseointegration can be achieved in calvarial reconstructions using prototyped Ti6Al4V Implants with the described characteristics of surface and porosity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports a survey of Leptospira spp in pampas deer (Ozotoceros bezoarticus) in the Pantanal wetlands of the state of Mato Grosso do Sul, Brazil by serology and polymerase chain reaction (PCR). Seventy pampas deer were captured in the dry season and surveyed using PCR, microscopic agglutination test (MAT) (n = 51) and by both techniques (n = 47). PCR detected infections in two pampas deer and MAT detected infections in three. Through sequencing and phylogenetic analyses, the PCR-amplified fragment detected in deer was identified as Leptospira interrogans. Serovars Pomona and Butembo were detected using MAT and the highest titre was 200 for serovar Pomona. Epidemiological aspects of the findings are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To determine cytomegalovirus (CMV) frequency in neonatal intrahepatic cholestasis by serology, histological revision (searching for cytomegalic cells), immunohistochemistry, and polymerase chain reaction (PCR), and to verify the relationships among these methods. METHODS: The study comprised 101 non-consecutive infants submitted for hepatic biopsy between March 1982 and December 2005. Serological results were obtained from the patient's files and the other methods were performed on paraffin-embedded liver samples from hepatic biopsies. The following statistical measures were calculated: frequency, sensibility, specific positive predictive value, negative predictive value, and accuracy. RESULTS: The frequencies of positive results were as follows: serology, 7/64 (11%); histological revision, 0/84; immunohistochemistry, 1/44 (2%), and PCR, 6/77 (8%). Only one patient had positive immunohistochemical findings and a positive PCR. The following statistical measures were calculated between PCR and serology: sensitivity, 33.3%; specificity, 88.89%; positive predictive value, 28.57%; negative predictive value, 90.91%; and accuracy, 82.35%. CONCLUSION: The frequency of positive CMV varied among the tests. Serology presented the highest positive frequency. When compared to PCR, the sensitivity and positive predictive value of serology were low. (C) 2009 The WJG Press and Baishicleng. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study evaluated the efficiency of diagnostic laboratory methods to detect anti-Toxoplasma gondii antibodies in paired serum and aqueous humour samples from experimentally infected pigs. 18-mixed breed pigs were used during the experiment; these were divided into two groups, G I (infected group, n = 10) and G2 (uninfected group, n = 8). Infection was performed with 4 x 10(4) VEG strain oocysts at day 0 by the oral route in G1 animals. All pigs were euthanized at day 60, when retina, aqueous humour, and blood samples were collected. Anti-T gondii antibody levels were assessed in serum (s) and aqueous humour (ah) by indirect immunofluorescence assay (IFA), modified agglutination test (MAT), m-ELISA (using crude membranes from T gondii tachyzoites as antigen) and r-ELISA (using rhoptries from T gondii tachyzoites as antigen). Polymerase chain reactions (PCR) of samples from the retina were performed by using Tox4 and Tox5 primers. Antibody titers of G1 animals ranged from 128 to 1024 and from 16 to 256 in serum and aqueous humour, respectively. There were differences in the correlation coefficients between IFA(s) x IFA (ah) (r = 0.62, P = 0.05), MAT(s) x MAT (ah) (r = 0.97, P < 0.0001); however, there was no significant difference between r-ELISA(s) x r-ELISA (ah) (r = 0. 14, P = 0.7). Antibodies present in serum and aqueous humour recognized similar antigens. Samples of retina were positive by PCR in 30% (3/10) of infected pigs. G2 animals remained without antibody levels and were PCR negative throughout the experiment. These results suggest that the use of a combination of tests and immunoblotting for paired aqueous humour and serum samples could improve the sensitivity and specificity for the diagnosis of ocular toxoplasmosis. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The flock-level sensitivity of pooled faecal culture and serological testing using AGID for the detection of ovine Johne's disease-infected flocks were estimated using non-gold-standard methods. The two tests were compared in an extensive field trial in 296 flocks in New South Wales during 1998. In each flock, a sample of sheep was selected and tested for ovine Johne's disease using both the AGID and pooled faecal culture. The flock-specificity of pooled faecal culture also was estimated from results of surveillance and market-assurance testing in New South Wales. The overall flock-sensitivity of pooled faecal culture was 92% (95% CI: 82.4 and 97.4%) compared to 61% (50.5 and 70.9%) for serology (assuming that both tests were 100% specific). In low-prevalence flocks (estimated prevalence

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present paper we focus on the performance of clustering algorithms using indices of paired agreement to measure the accordance between clusters and an a priori known structure. We specifically propose a method to correct all indices considered for agreement by chance - the adjusted indices are meant to provide a realistic measure of clustering performance. The proposed method enables the correction of virtually any index - overcoming previous limitations known in the literature - and provides very precise results. We use simulated datasets under diverse scenarios and discuss the pertinence of our proposal which is particularly relevant when poorly separated clusters are considered. Finally we compare the performance of EM and KMeans algorithms, within each of the simulated scenarios and generally conclude that EM generally yields best results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty one cases of molluscum contagiosum virus disease were collected for electron microscopical and serological tests. Molluscum virus was detected in the crust, inside the vacuoles formed in the keratinocytes cells. The patients developed specific antibodies to the virus detected by complement fixation test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In search of an efficient but simple, low cost procedure for the serodiagnosis of Toxoplasmosis, especially suited for routine laboratories facing technical and budget limitations as in less developed countries, the diagnostic capability of Hematoxo® , an hemagglutination test for toxoplasmosis, was evaluated in relation to a battery of tests including IgG- and IgM-immunofluorescence tests, hemagglutination and an IgM-capture enzymatic assay. Detecting a little as 5 I.U. of IgG antitoxoplasma antibodies, Hematoxo® showed a straight agreement as to reactivity and non-reactivity for the 443 non-reactive and the 387 reactive serum samples, included in this study. In 23 cases presenting a serological pattern of acute toxoplasmosis and showing IgM antibodies, Hematoxo® could detect IgM antibodies in 18, indicated by negativation or a significant decrease in titers as a result of treating samples with 2-mercapto-ethanol. However, a neat increase in sensitivity for IgM specific antibodies could be achieved by previously removing IgG from the sample, as demonstrated in a series of acute toxoplasmosis sera. A simple procedure was developed for this purpose, by reconstituting a lyophilized suspension of Protein A - rich Staphylococcus with the lowest serum dilution to be tested. Of low cost and easy to perform, Hematoxo® affords not only a practical qualitative procedure for screening reactors and non-reactors, as in prenatal services, but also quantitative assays that permit to titrate antibodies as well as to identify IgM antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study evaluated six Plasmodium falciparum antigen extracts to be used in the IgG and IgM enzyme-linked immunosorbent assays (ELISA), for malaria diagnosis and epidemiological studies. Results obtained with eighteen positive and nine negative control sera indicated that there were statistically significant differences among these antigen extracts (Multifactor ANOVA, p< 0.0001). Urea, sodium deoxycholate and Zwittergent antigen extracts performed better than did the three others, their features being very similar for the detection of IgG antibodies. Urea, alkaline and sodium deoxycholate antigen extracts proved to be better than the others for the detection of IgM antibodies. A straight line relationship was found between the optical densities (or their respective log 10) and the log 10 of antibody dilutions, with a very constant slope. Thus serum titers could be determined by direct titration and by two different equations, needing only one serum dilution. For IgM antibody detections, log 10 expression gave results that better correlated with direct titration (95% Bonferroni). For IgG antibody detections, the titer differences were not significant. The reproducibility of antibody titers and antigen batches was also evaluated, giving satisfactory results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present paper we compare clustering solutions using indices of paired agreement. We propose a new method - IADJUST - to correct indices of paired agreement, excluding agreement by chance. This new method overcomes previous limitations known in the literature as it permits the correction of any index. We illustrate its use in external clustering validation, to measure the accordance between clusters and an a priori known structure. The adjusted indices are intended to provide a realistic measure of clustering performance that excludes agreement by chance with ground truth. We use simulated data sets, under a range of scenarios - considering diverse numbers of clusters, clusters overlaps and balances - to discuss the pertinence and the precision of our proposal. Precision is established based on comparisons with the analytical approach for correction specific indices that can be corrected in this way are used for this purpose. The pertinence of the proposed correction is discussed when making a detailed comparison between the performance of two classical clustering approaches, namely Expectation-Maximization (EM) and K-Means (KM) algorithms. Eight indices of paired agreement are studied and new corrected indices are obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neurocysticercosis (NC), the presence of Taenia solium metacestodes in tissues, is the most frequent and severe parasitic infection of the central nervous system. We investigated the presence of total IgE by an automated chemiluminescence assay in 53 paired cerebrospinal fluid (CSF) and serum samples from patients with NC (P) and in 40 CSF samples from individuals with other neurological disorders as the control group (C). Total IgE concentration ranged from 1.2 to 6.6 IU/ml (mean = 1.4 IU/ml, standard deviation-sd = 1.1 IU/ml) in 28.3% of CSF samples from the P group, a value significantly higher than for the C group (£1.0 IU/ml). The serum samples from the P group showed concentrations ranging from 1.0 to 2330.0 IU/ml (mean = 224.1 IU/ml, sd = 452.1 IU/ml), which were higher than the normal value cited by the manufacturer (<100.0 IU/ml) in 32.1% of the samples. A significant difference was observed in CSF samples from the P and C groups (p = 0.005) and in serum samples from the P group compared to the normal value (p = 0.005), with sera showing more frequent abnormal results.