967 resultados para Painel fotovoltaico
Resumo:
Low voltage solar panels increase the reliability of solar panels due to reduction of in series associations the configurations of photovoltaic cells. The low voltage generation requires DCDC converters devices with high efficiency, enabling raise and regulate the output voltage. This study analyzes the performance of a photovoltaic panel of Solarex, MSX model 77, configured to generate an open circuit voltage of 10.5 V, with load voltage of 8.5 V, with short circuit current of 9 A and a power of 77 W. The solar panel was assembled in the isolated photovoltaic system configuration, with and without energy storage as an interface with a DCDC converter, Booster topology. The converter was designed and fabricated using SMD (Surface Mounted Devices) technology IC (integrated circuit) that regulates its output voltage at 14.2 V, with an efficiency of 87% and providing the load a maximum power of 20.88 W. The system was installed and instrumented for measurement and acquisition of the following data: luminosities, average global radiation (data of INPE Instituto Nacional de Pesquisas Espaciais), solar panel and environment temperatures, solar panel and DC-DC converter output voltages, panel, inverter, and battery charge output currents. The photovoltaic system was initially tested in the laboratory (simulating its functioning in ideal conditions of operation) and then subjected to testing in real field conditions. The panel inclination angle was set at 5.5°, consistent with the latitude of Natal city. Factors such as climatic conditions (simultaneous variations of temperature, solar luminosities and ra diation on the panel), values of load resistance, lower limit of the maximum power required by the load (20.88 W) were predominant factors that panel does not operate with energy efficiency levels greater than 5 to 6%. The average converter efficiency designed in the field test reached 95%
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Since ancient times, it has been a huge challenge to all people around the world to manage to get their fresh water, keeping it clean and providing it to every human being, so that it can be used for their daily needs. This is especially true for small properties in the countryside and in isolated areas with low demographic density. Pumping the water in those regions is a solution that rationalizes its use in domestic chores, in animal rearing and in the irrigation systems of cultivated areas. Making feasible local, renewable and non-polluted energetic alternatives is the aim for those areas that are usually far away from the public electric network. Using photovoltaic solar energy is the alternative now proposed. For this objective was built a system with two monocrystalline panels, one pump, two water tanks, two level sensors and a solenoid valve to pump water, using a pump powered an array of monocrystalline solar panels. The main goal was to compare their rate of water flow and their energy consumption. The use of one data acquisition equipment allowed collecting meteorological, electrical and hydraulic values, and also serving for the control and activation of the pumping system. During four months in a row as from April 2009, arrangements with one or two panels were tested. Mathematics correlations and adjustment lines were used to interpret the behavior of obtained dataset. During the analyzed period the system followed the linear equations with great accuracy. The daily average amount of water pumped by the several tested arrays stayed between 1,100 and 2,500 liters, and that is enough to supply a small rural property. The pumping system with two panels effectively showed the major amount of water, but a system with one panel can be an economical solution until 1,500 liters on day. It did not characterize a direct relationship between power or quantity of photovoltaic panels and daily outflow of water pumping.
Resumo:
A eficiência energética e a domótica são temas que cada vez mais se relacionam. Ao se instalar uma solução de domótica numa habitação, é natural que a mesma ofereça opções que permitem poupar energia, e assim obter eficiência energética. O principal objetivo deste projeto é a criação de um quadro elétrico que permita a monitorização e controlo de energia numa habitação à distância de um “clique”. Para a concepção do quadro elétrico foram utilizados dispositivos da Schneider Electric, dos quais se destaca o EGX300. Este dispositivo, é comercializado como um produto que representa uma solução de eficiência energética. No entanto as suas funcionalidades de fábrica estão limitadas ao nível de análise da qualidade de energia, não oferecendo um sistema que possibilite controlo remoto. Aproveitando as capacidades do EGX300, foi considerado pertinente criar uma solução onde, além de se poder monitorizar os consumos, também fosse possível controlar os dispositivos através de um computador. À capacidade de controlo da instalação ainda se juntou um modo de funcionamento inteligente, onde o EGX300 controla a instalação elétrica de acordo com a energia produzida por um painel fotovoltaico. A implementação de novas funcionalidades no EGX300 resulta num acréscimo significativo de robustez em relação à solução proposta pela empresa. Conseguiu-se criar uma solução que integra segurança e domótica com a utilização de energias renováveis, tendo como consequência natural a maximização de eficiência energética numa habitação.
Resumo:
The rural electrification is characterized by geographical dispersion of the population, low consumption, high investment by consumers and high cost. Moreover, solar radiation constitutes an inexhaustible source of energy and in its conversion into electricity photovoltaic panels are used. In this study, equations were adjusted to field conditions presented by the manufacturer for current and power of small photovoltaic systems. The mathematical analysis was performed on the photovoltaic rural system I- 100 from ISOFOTON, with power 300 Wp, located at the Experimental Farm Lageado of FCA/UNESP. For the development of such equations, the circuitry of photovoltaic cells has been studied to apply iterative numerical methods for the determination of electrical parameters and possible errors in the appropriate equations in the literature to reality. Therefore, a simulation of a photovoltaic panel was proposed through mathematical equations that were adjusted according to the data of local radiation. The results have presented equations that provide real answers to the user and may assist in the design of these systems, once calculated that the maximum power limit ensures a supply of energy generated. This real sizing helps establishing the possible applications of solar energy to the rural producer and informing the real possibilities of generating electricity from the sun.
Resumo:
In this paper we discussed the possibility of installing a photovoltaic panel in a house in order to reduce electrical consumption. Brazil is a country with a huge solar resource and photovoltaic technology allows transforming solar energy into electricity, helping to decentralize energy production. To enlarge the field of view, the study compares with the equivalent in a Spanish city, discussing how the law favors the initiative of using this type of energy. It will be seen that, with the encouragement of the government, the project can be done because the installation is amortized over a reasonable period of time, about eight years in Spain and three in Brazil
Resumo:
Due to concerns about rational use of energy, several alternative technologies of power generation appeared, including the conversion of solar energy into electrical energy by photovoltaic panels. In low-income households, the refrigerator represents considerable impact on the electric bill, since it requires constant power given its use in food preservation. It is possible to reduce this share, with the use of an alternative energy source. This work presents a timed switching electronic system, which allows commercial equipment that is not affected by short interruptions in the power supply to use a photovoltaic panel as a source of alternative energy, which usually do not provide energy continuously. Switching is made automatically in case of low incidence of sunlight, and without any form of energy storage. Between each switching, there is a dead time without power supply, therefore preventing the use of synchronizers circuits between the photovoltaic panel and the public power grid. A circuit containing a 80C31 microcontroller is used to control the system’s switching. The photovoltaic panel’s voltage inverter is in H bridge configuration, and is also controlled by the microcontroller through Pulse Width Modulation, which makes use of preprogrammed tables to generate the control signals of the power transistors. Through the use of software simulations, the proposed system was tested, which is capable of supplying intermittent single-phase loads. The simulations indicates that the project developed in this paper can be assembled into a prototype and be tested under real operating conditions, as long as the scaling of components, the characteristics of the photovoltaic panel to be used, and the project involved load are taken into account
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
The rural electrification is characterized by geographical dispersion of the population, low consumption, high investment by consumers and high cost. Moreover, solar radiation constitutes an inexhaustible source of energy and in its conversion into electricity photovoltaic panels are used. In this study, equations were adjusted to field conditions presented by the manufacturer for current and power of small photovoltaic systems. The mathematical analysis was performed on the photovoltaic rural system I- 100 from ISOFOTON, with power 300 Wp, located at the Experimental Farm Lageado of FCA/UNESP. For the development of such equations, the circuitry of photovoltaic cells has been studied to apply iterative numerical methods for the determination of electrical parameters and possible errors in the appropriate equations in the literature to reality. Therefore, a simulation of a photovoltaic panel was proposed through mathematical equations that were adjusted according to the data of local radiation. The results have presented equations that provide real answers to the user and may assist in the design of these systems, once calculated that the maximum power limit ensures a supply of energy generated. This real sizing helps establishing the possible applications of solar energy to the rural producer and informing the real possibilities of generating electricity from the sun.
Resumo:
Neste trabalho apresenta-se o modelo de um controlador baseado em Lógica Fuzzy para um sistema de energia baseado em fonte renovável solar fotovoltaica (photovoltaic - PV) multi-string em operação isolada, para o aproveitamento da máxima potência desta fonte. O sistema é composto por painéis solares, conversor CC-CC tipo elevador de tensão (boost), armazenamento por banco de baterias, inversor trifásico e carga trifásica variável. O sistema fotovoltaico foi modelado no MATLAB/Simulink de forma a representar a curva característica V-I do módulo PV, e que é baseado nos dados disponíveis em data-sheets de painéis fotovoltaicos comerciais. Outros estudos de natureza elétrica tais como o cálculo dos valores eficazes das correntes no conversor CC-CC, para avaliação das perdas, indispensáveis para o dimensionamento de componentes eletrônicos, foram realizados. O método tradicional Perturb and Observe de rastreamento do ponto de máxima potência (Maximum Power Point Tracking MPPT) de painéis foi testado e comparado com métodos que usam a Lógica Fuzzy. Devido ao seu desempenho, foi adotado o método Fuzzy que realiza o MPPT por inferência do ciclo de trabalho de um modulador por largura de pulso (Pulse Width Modulation - PWM) através da variação da potência pela variação da corrente do painel solar. O modelo Fuzzy adotado neste trabalho foi testado com sucesso. Os resultados mostraram que ele pode ser robusto e atende à aplicação proposta. Segundo alguns testes realizados, este controlador pode realizar o MPPT de um sistema PV na configuração multi-string onde alguns arranjos fotovoltaicos são usados. Inclusive, este controle pode ser facilmente adaptado para realizar o MPPT de outras fontes de energia baseados no mesmo princípio de controle, como é o caso do aerogerador.
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Energia
Resumo:
[ES]Este proyecto tiene como objetivo diseñar e implementar un prototipo de un cargador fotovoltaico para teléfonos móviles de última generación. Dicho prototipo constará de un panel fotovoltaico, reguladores de tensión y corriente, un MPPT, un regulador de carga de batería, una batería auxiliar y una conexión USB para conectarlo al dispositivo a cargar. Para su realización, se llevará a cabo un estudio previo para obtener conocimientos sobre el funcionamiento de las nuevas tecnologías en esta área, su oferta en el mercado, y se hará uso de las herramientas necesarias para su diseño, implementación y pruebas posteriores.
Resumo:
Esta tese investiga os efeitos agudos da poluição atmosférica no pico de fluxo expiratório (PFE) de escolares com idades entre 6 e 15 anos, residentes em municípios da Amazônia Brasileira. O primeiro artigo avaliou os efeitos do material particulado fino (PM2,5) no PFE de 309 escolares do município de Alta Floresta, Mato Grosso (MT), durante a estação seca de 2006. Modelos de efeitos mistos foram estimados para toda a amostra e estratificados por turno escolar e presença de sintomas de asma. O segundo artigo expõe as estratégias utilizadas para a determinação da função de variância do erro aleatório dos modelos de efeitos mistos. O terceiro artigo analisa os dados do estudo de painel com 234 escolares, realizado na estação seca de 2008 em Tangará da Serra, MT. Avaliou-se os efeitos lineares e com defasagem distribuída (PDLM) do material particulado inalável (PM10), do PM2,5 e do Black Carbon (BC) no PFE de todos os escolares e estratificados por grupos de idade. Nos três artigos, os modelos de efeitos mistos foram ajustados por tendência temporal, temperatura, umidade e características individuais. Os modelos também consideraram o ajuste da autocorrelação residual e da função de variância do erro aleatório. Quanto às exposições, foram avaliados os efeitos das exposições de 5hs, 6hs, 12hs e 24hs, no dia corrente, com defasagens de 1 a 5 dias e das médias móveis de 2 e 3 dias. No que se refere aos resultados de Alta Floresta, os modelos para todas as crianças indicaram reduções no PFE variando de 0,26 l/min (IC95%: 0,49; 0,04) a 0,38 l/min (IC95%: 0,71; 0,04), para cada aumento de 10g/m3 no PM2,5. Não foram observados efeitos significativos da poluição no grupo das crianças asmáticas. A exposição de 24hs apresentou efeito significativo no grupo de alunos da tarde e no grupo dos não asmáticos. A exposição de 0hs a 5:30hs foi significativa tanto para os alunos da manhã quanto para a tarde. Em Tangará da Serra, os resultados mostraram reduções significativas do PFE para aumentos de 10 unidades do poluente, principalmente para as defasagens de 3, 4 e 5 dias. Para o PM10, as reduções variaram de 0,15 (IC95%: 0,29; 0,01) a 0,25 l/min (IC95%: 0,40 ; 0,10). Para o PM2,5, as reduções estiveram entre 0,46 l/min (IC95%: 0,86 to 0,06 ) e 0,54 l/min (IC95%: 0,95; 0,14). E no BC, a redução foi de aproximadamente 0,014 l/min. Em relação ao PDLM, efeitos mais importantes foram observados nos modelos baseados na exposição do dia corrente até 5 dias passados. O efeito global foi significativo apenas para o PM10, com redução do PFE de 0,31 l/min (IC95%: 0,56; 0,05). Esta abordagem também indicou efeitos defasados significativos para todos os poluentes. Por fim, o estudo apontou as crianças de 6 a 8 anos como grupo mais sensível aos efeitos da poluição. Os achados da tese sugerem que a poluição atmosférica decorrente da queima de biomassa está associada a redução do PFE de crianças e adolescentes com idades entre 6 e 15 anos, residentes na Amazônia Brasileira.