708 resultados para PRECISION CONTACT
Resumo:
The purpose of this study was to investigate whether the additional sensory information could improve postural control in individuals with unilateral anterior cruciate ligament (ACL) injury. Twenty-eight individuals with unilateral ACL injury (mean age 23.6, 26 males, 2 females) and 28 healthy young control subjects (mean age 22.1 years, 26 males, 2 females) participated in this study. Postural control was evaluated with subjects single-leg standing on a force platform with eyes closed under two sensory conditions: normal sensory information and light touch to a stationary bar (applied force below 1 N). Three trials of 30 5 were performed in each single-leg stance and in each sensory condition. Mean sway amplitude and predominant frequency of center of pressure were calculated for both anterior-posterior and medial-lateral directions. Individuals with ACL injury showed greater mean sway amplitude than healthy control individuals even though the predominant frequency was similar for both groups. Additional sensory information improved postural control performance in individuals with ACL injury and healthy control, with a greater effect observed for the ACL group. Based on these results, we suggest that reduction in postural control performance in individuals with ACL injury would be due to the reduction of sensory information provided by the ACL, but when sensory information is enhanced, postural control performance improves. These results have implications for novel approaches to improve stability in individuals with ACL injury. (c) 2008 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The effects of temporal precision constraints and movement amplitude on performance of an interceptive aiming task were examined. Participants were required to strike a moving target object with a 'bat' by moving the bat along a straight path (constrained by a linear slide) perpendicular to the path of the target. Temporal precision constraints were defined in terms of the time period (or window) within which contact with the target was possible. Three time windows were used (approx. 35, 50 and 65 ms) and these were achieved either by manipulating the size of the bat (experiment 1a), the size of the target (experiment 1b) or the speed of the target (experiment 2). In all experiments, movement time (MT) increased in proportion to movement amplitude but was only affected by differences in the temporal precision constraint if this was achieved by variation in the target's speed. In this case the MT was approximately inversely proportional to target speed. Peak movement speed was affected by temporal accuracy constraints in all three experiments: participants reached higher speeds when the temporal precision required was greater. These results are discussed with reference to the speed-accuracy trade-off observed for temporally constrained aiming movements. It is suggested that the MT and speed of interceptive aiming movements may be understood as responses to the spatiotemporal constraints of the task.
Resumo:
The present work reports new sensors for the direct determination of Microcystin-LR (MC-LR) in environmental waters. Both selective membrane and solid contact were optimized to ensure suitable analytical features in potentiometric transduction. The sensing layer consisted of Imprinted Sol–Gel (ISG) materials capable of establishing surface interactions with MC-LR. Non-Imprinted Sol–Gel (NISG) membranes were used as negative control. The effects of an ionic lipophilic additive, time of sol–gel polymerization, time of extraction of MC-LR from the sensitive layer, and pH were also studied. The solid contact was made of carbon, aluminium, titanium, copper or nickel/chromium alloys (80 : 20 or 90 : 10). The best ISG sensor had a carbon solid contact and displayed average slopes of 211.3 mV per decade, with detection limits of 7.3 1010 M, corresponding to 0.75 mg L1 . It showed linear responses in the range of 7.7 1010 to 1.9 109 M of MC-LR (corresponding to 0.77–2.00 mg L1 ), thus including the limiting value for MC-LR in waters (1.0 mg L1 ). The potentiometric-selectivity coefficients were assessed by the matched potential method for ionic species regularly found in waters up to their limiting levels. Chloride (Cl) showed limited interference while aluminium (Al3+), ammonium (NH4 + ), magnesium (Mg2+), manganese (Mn2+), sodium (Na+ ), and sulfate (SO4 2) were unable to cause the required potential change. Spiked solutions were tested with the proposed sensor. The relative errors and standard deviation obtained confirmed the accuracy and precision of the method. It also offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.
Resumo:
AbstractPurpose: to evaluate the tolerability, comfort and precision of the signal transmission of an ocular Sensor used for 24-hour intraocular pressure fluctuation monitoring in humans.Patients and methods: In this uncontrolled open trial involving 10 healthy volunteers an 8.7 mm radius prototype ocular telemetry Sensor (SENSIMED Triggerfish®, Lausanne, Switzerland) and an orbital bandage containing a loop antenna were applied and connected to a portable recorder after full eye examination. Best corrected visual acuity and position, surface wetting ability and mobility of the Sensor were assessed after 5 and 30 minutes, 4, 12 and 24 hours. Subjective wearing comfort was scored and activities documented in a logbook. After Sensor removal a full eye examination was repeated and the recorded signal analyzed.Results: The comfort score was high and did not fluctuate significantly over time. The mobility of the Sensor was limited across follow-up visits and its surface wetting ability remained good. Best corrected visual acuity was significantly reduced during Sensor wear and immediately after its removal (from 1.07 before, to 0.85 after, P-value 0.008). Three subjects developed a mild, transient corneal abrasion. In all but one participant we obtained usable data of a telemetric signal recording with sufficient sensitivity to depict ocular pulsation.Conclusions: This 24-hour- trial has encouraging results on the tolerability and functionality of the ocular telemetric Sensor for intraocular pressure fluctuation monitoring. Further studies with different Sensor radii conducted on a larger study population are needed to improve comfort, precision and interpretation of the telemetric signal.
Non-contact assessment of waist circumference: will tape measurements become progressively obsolete?
Resumo:
Waist circumference (WC) is a key variable to assess in health management as it is a proxy of abdominal fat mass and a surrogate marker of cardiometabolic disease risk, including the metabolic syndrome. Recently, a portable non-contact device calculating WC (ViScan) has been developed, which hence allows the tracking of WC independently of the inter-investigators error. We compared WC values obtained with this device with WC measured by simple non-stretchable tape in 74 adults of varying body mass indices (range 17-39 kg/m(2)). The correlation between the two methods was very high (r=0.97, P<0.0001) and the reproducibility (precision) assessed with a rigid phantom was excellent (<1 cm, coefficient of variability<1%). The instrument constitutes a potentially valuable tool for longitudinal surveys and comparative international studies, which require simple but precise measurements of WC in order to track the effect of subtle changes on various health outcomes.
Resumo:
Purpose: In vitro studies in porcine eyes have demonstrated a good correlation between induced intraocular pressure variations and corneal curvature changes, using a contact lens with an embedded microfabricated strain gauge. Continuous 24 hour-intraocular pressure (IOP) monitoring to detect large diurnal fluctuation is currently an unmet clinical need. The aims of this study is to evaluate precision of signal transmission and biocompatibility of 24 hour contact lens sensor wear (SENSIMED Triggerfish®) in humans. Methods: After full eye examination in 10 healthy volunteers, a 8.7 mm radius contact lens sensor and an orbital bandage containing a loop antenna were applied and connected to a portable recorder. Best corrected visual acuity and position, lubrication status and mobility of the sensor were assessed after 5 and 30 minutes, 4, 7 and 24 hours. Subjective comfort was scored and activities documented in a logbook. After sensor removal full eye examination was repeated, and the registration signal studied. Results: The comfort score was high and did not fluctuate significantly, except at the 7 hour-visit. The mobility of the contact lens was minimal but its lubrication remained good. Best corrected visual acuity was significantly reduced during the sensor wear and immediately after its removal. Three patients developed mild corneal staining. In all but one participant we obtained a registration IOP curve with visible ocular pulse amplitude. Conclusions: This 24 hour-trial confirmed the functionality and biocompatibility of SENSIMED Triggerfish® wireless contact lens sensor for IOP-fluctuation monitoring in volunteers. Further studies with a range of different contact lens sensor radii are indicated.
Resumo:
Several machining processes have been created and improved in order to achieve the best results ever accomplished in hard and difficult to machine materials. Some of these abrasive manufacturing processes emerging on the science frontier can be defined as ultra-precision grinding. For finishing flat surfaces, researchers have been putting together the main advantages of traditional abrasive processes such as face grinding with constant pressure, fixed abrasives for two-body removal mechanism, total contact of the part with the tool, and lapping kinematics as well as some specific operations to keep grinding wheel sharpness and form. In the present work, both U d-lap grinding process and its machine tool were studied aiming nanometric finishing on flat metallic surfaces. Such hypothesis was investigated on AISI 420 stainless steel workpieces U d-lap ground with different values of overlap factor on dressing (Ud=1, 3, and 5) and grit sizes of conventional grinding wheels (silicon carbide (SiC)=#800, #600, and #300) applying a new machine tool especially designed and built for such finishing. The best results, obtained after 10 min of machining, were average surface roughness (Ra) of 1.92 nm, 1.19-μm flatness deviation of 25.4-mm-diameter workpieces, and mirrored surface finishing. Given the surface quality achieved, the U d-lap grinding process can be included among the ultra-precision abrasive processes and, depending on the application, the chaining steps of grinding, lapping, and polishing can be replaced by the proposed abrasive process.
Resumo:
As we settle into a new year, this second issue of Contact Lens and Anterior Eye allows us to reflect on how new research in this field impacts our understanding, but more importantly, how we use this evidence basis to enhance our day to day practice, to educate the next generation of students and to construct the research studies to deepen our knowledge still further. The end of 2014 saw the publication of the UK governments Research Exercise Framework (REF) which ranks Universities in terms of their outputs (which includes their paper, publications and research income), environment (infrastructure and staff support) and for the first time impact (defined as “any effect on, change or benefit to the economy, society, culture, public policy or services, health, the environment or quality of life, beyond academia” [8]). The REF is a process of expert review, carried out in 36 subject-based units of assessment, of which our field is typically submitted to the Allied Health, Dentistry, Nursing and Pharmacy panel. Universities that offer Optometry did very well with Cardiff, Manchester and Aston in the top 10% out of the 94 Universities that submitted to this panel (Grade point Average ranked order). While the format of the new exercise (probably in 2010) to allocate the more than £2 billion of UK government research funds is yet to be determined, it is already rumoured that impact will contribute an even larger proportion to the weighting. Hence it is even more important to reflect on the impact of our research. In this issue, Elisseef and colleagues [5] examine the intriguing potential of modifying a lens surface to allow it to bind to known wetting agents (in this case hyaluronic acid) to enhance water retention. Such a technique has the capacity to reduced friction between the lens surface and the eyelids/ocular surface, presumably leading to higher comfort and less reason for patients to discontinue with lens wear. Several papers in this issue report on the validity of new high precision, fast scanning imaging and quantification equipment, utilising techniques such as Scheimpflug, partial coherence interferometry, aberrometry and video allowing detailed assessment of anterior chamber biometry, corneal topography, corneal biomechanics, peripheral refraction, ocular aberrations and lens fit. The challenge is how to use this advanced instrumentation which is becoming increasingly available to create real impact. Many challenges in contact lenses and the anterior eye still prevail in 2015 such as: -While contact lens and refractive surgery complications are relatively rare, they are still too often devastating to the individual and their quality of life (such as the impact and prognosis of patients with Acanthmoeba Keratitis reported by Jhanji and colleagues in this issue [7]). How can we detect those patients who are going to be affected and what modifications do we need to make to contact lenses and patient management prevent this occurring? -Drop out from contact lenses still occurs at a rapid rate and symptoms of dry eye seem to be the leading cause driving this discontinuation of wear [1] and [2]. What design, coating, material and lubricant release mechanism will make a step change in end of day comfort in particular? -Presbyopia is a major challenge to hassle free quality vision and is one of the first signs of ageing noticed by many people. As an emmetrope approaching presbyopia, I have a vested interest in new medical devices that will give me high quality vision at all distances when my arms won’t stretch any further. Perhaps a new definition of presbyopia could be when you start to orientate your smartphone in the landscape direction to gain the small increase in print size needed to read! Effective accommodating intraocular lenses that truly mimic the pre-presbyopic crystalline lenses are still a way off [3] and hence simultaneous images achieved through contact lenses, intraocular lenses or refractive surgery still have a secure future. However, splitting light reaching the retina and requiring the brain to supress blurred images will always be a compromise on contrast sensitivity and is liable to cause dysphotopsia; so how will new designs account for differences in a patient's task demands and own optical aberrations to allow focused patient selection, optimising satisfaction? -Drug delivery from contact lenses offers much in terms of compliance and quality of life for patients with chronic ocular conditions such as glaucoma, dry eye and perhaps in the future, dry age-related macular degeneration; but scientific proof-of-concept publications (see EIShaer et al. [6]) have not yet led to commercial products. Part of this is presumably the regulatory complexity of combining a medical device (the contact lens) and a pharmaceutical agent. Will 2015 be the year when this innovation finally becomes a reality for patients, bringing them an enhanced quality of life through their eye care practitioners and allowing researchers to further validate the use of pharmaceutical contact lenses and propose enhancements as the technology matures? -Last, but no means least is the field of myopia control, the topic of the first day of the BCLA's Conference in Liverpool, June 6–9th 2015. The epidemic of myopia is a blight, particularly in Asia, with significant concerns over sight threatening pathology resulting from the elongated eye. This is a field where real impact is already being realised through new soft contact lens optics, orthokeratology and low dose pharmaceuticals [4], but we still need to be able to better predict which technique will work best for an individual and to develop new techniques to retard myopia progression in those who don’t respond to current treatments, without increasing their risk of complications or the treatment impacting their quality of life So what will your New Year's resolution be to make 2015 a year of real impact, whether by advancing science or applying the findings published in journals such as Contact Lens and Anterior Eye to make a real difference to your patients’ lives?
Resumo:
Станимир Д. Илиев, Нина Хр. Пешева - Представен е хибриден експериментално-числен метод, работещ в реално време, за определяне на макроскопичния динамичен контактен ъгъл, който менискусът на течност в съд формира с вертикална пластина, която се потапя или издърпва с постоянна скорост от съда с течността. Този метод е приложим, когато системата е в стационарно състояние. Методът се базира на пълния хидродинамичен модел на Войнов. Той позволява да се получи числено с висока точност стационарната форма на профила на динамичния менискус (и от там ъгълът на наклон на менискуса) като се използва като гранично условие експериментално определената височина на менискуса на пластината.
Resumo:
Composite resins might be susceptible to degradation and staining when in contact with some foods and drinks. This study evaluated color alteration and changes in microhardness of a microhybrid composite after immersion in different colored foods and determined whether there was a correlation between these two variables. Eighty composite disks were randomly divided into 8 experimental groups (n = 10): kept dry; deionized water; orange juice; passion fruit juice; grape juice; ketchup; mustard and soy sauce. The disks were individually immersed in their respective test substance at 37 ºC, for a period of 28 days. Superficial analysis of the disk specimens was performed by taking microhardness measurements (Vickers, 50 g load for 45 seconds) and color alterations were determined with a spectrophotometer (CINTRA 10- using a CIEL*a*b* system, 400-700 nm wavelength, illuminant d65 and standard observer of 2º) at the following times: baseline (before immersion), 1, 7, 14, 21 and 28 days. Results were analyzed by ANOVA and Tukey's test (p < 0.05). Both variables were also submitted to Pearson's correlation test (p < 0.05). The passion fruit group underwent the greatest microhardness change, while the mustard group suffered the greatest color alteration. Significant positive correlation was found between the two variables for the groups deionized water, grape juice, soy sauce and ketchup. Not all color alteration could be associated with surface degradation.
Resumo:
We study how the crossover exponent, phi, between the directed percolation (DP) and compact directed percolation (CDP) behaves as a function of the diffusion rate in a model that generalizes the contact process. Our conclusions are based in results pointed by perturbative series expansions and numerical simulations, and are consistent with a value phi = 2 for finite diffusion rates and phi = 1 in the limit of infinite diffusion rate.
Resumo:
Some factors complicate comparisons between linkage maps from different studies. This problem can be resolved if measures of precision, such as confidence intervals and frequency distributions, are associated with markers. We examined the precision of distances and ordering of microsatellite markers in the consensus linkage maps of chromosomes 1, 3 and 4 from two F 2 reciprocal Brazilian chicken populations, using bootstrap sampling. Single and consensus maps were constructed. The consensus map was compared with the International Consensus Linkage Map and with the whole genome sequence. Some loci showed segregation distortion and missing data, but this did not affect the analyses negatively. Several inversions and position shifts were detected, based on 95% confidence intervals and frequency distributions of loci. Some discrepancies in distances between loci and in ordering were due to chance, whereas others could be attributed to other effects, including reciprocal crosses, sampling error of the founder animals from the two populations, F(2) population structure, number of and distance between microsatellite markers, number of informative meioses, loci segregation patterns, and sex. In the Brazilian consensus GGA1, locus LEI1038 was in a position closer to the true genome sequence than in the International Consensus Map, whereas for GGA3 and GGA4, no such differences were found. Extending these analyses to the remaining chromosomes should facilitate comparisons and the integration of several available genetic maps, allowing meta-analyses for map construction and quantitative trait loci (QTL) mapping. The precision of the estimates of QTL positions and their effects would be increased with such information.
Resumo:
Aim of this study was to analyse contact endoscopy as an auxiliary method for identifying parathyroid glands during thyroid surgery and to identify other variables that may interfere with this correlation. overall, 125 patients underwent thyroid surgery between January 2004 and February 2006. The variables analysed were: the total duration of surgery; time taken to locate and identify parathyroid glands; improvement in identifying these; numbers of parathyroid glands located by the surgeon and confirmed by contact endoscopy; histopathological diagnosis; presence of thyroiditis; thyroid weight; number of parathyroid glands left in thyroid specimens; and number of parathyroid gland autotransplantations. A total of 331 parathyroid glands were observed by the surgeon. however, 282 glands were identified by contact endoscopy. nine parathyroid glands (7.2%) were observed together with thyroid specimens (Kappa = 0.534). The longer the total duration of surgery (p = 0.03) and time taken to locate and identify (p = 0.00) the parathyroid glands by contact endoscopy, the lower the observed agreement. The second year of performing contact endoscopy led to better agreement between the results (p = 0.02). in conclusion, contact endoscopy is an efficient auxiliary method for identifying parathyroid glands during thyroid surgery. During the period studied, association between total duration of surgery and time taken to locate and identify parathyroid glands was statistically significant.
Resumo:
Background Tuberculosis clusters in families may be due to increased household exposure, shared genetic factors, or both. Household contact studies are useful to control exposure because socioeconomic and environmental conditions are similar to all subjects, allowing the evaluation of the contribution of relatedness to disease development. Methods In this study, the familial aggregation of tuberculosis using relatedness and a specific inherited marker (HLA-DRB1) was evaluated. Fifty families, which had at least two cases of tuberculosis diagnosed within the past 5 years, were selected from a cohort of tuberculosis carried out in Recife, Brazil. The first case diagnosed was considered to be a primary case. The secondary attack rate of tuberculosis in household contacts was estimated according to the degree of relatedness. The relative risk of having tuberculosis based on the degree of relatedness household and the population attributable fraction to relatedness were also estimated. HLA-DRB1 typing and attributable etiologic/preventive fractions were calculated among sick and healthy household contacts. Results Compared to unrelated contacts, the relative risk for tuberculosis adjusted for age was 1.38 (95% CI 0.86 to 2.21). Relatedness contributed 23% to the development of tuberculosis at the population levels. The HLA-DRB1*04 allele group (OR = 2.44; p =0.0324; etiologic fraction =0.15) was overrepresented and the DRB1*15 allele group (OR=0.48; p=0.0488; protective fraction=0.19) was underrepresented among household contacts exhibiting tuberculosis. The presence of DRB1 shared alleles between primary cases and their contacts was a risk factor for tuberculosis (p=0.0281). Conclusion This household contact model together with the utilisation of two genetic variables permitted the evaluation of genetic factors contributing towards tuberculosis development.
Resumo:
Objectives: to identify women`s feelings after early contact with their newborn infants in the delivery room, and to identify how health professionals involved in mother and infant care behave in the intrapartum setting. Design: a qualitative approach using semi-structured interviews and observation. Content analysis was used to derive the three themes that emerged from the interviews. Setting and participants: 23 postpartum women and their caregivers in a public maternity hospital in Ribeirao Preto, Brazil. Findings: three thematic categories emerged from the interviews: heightened fear, severe pain and intense conflict. The professionals` actions revealed that they have theoretical and practical abilities for humanisation of care, but their actions are fragmented. Final considerations: women can feel lonely, fearful and conflicted in the delivery room, and they also experience pain. Giving birth is a major event in a woman`s life, so it is important to facilitate a positive experience. Health professionals were found to display interventionist and impersonal attitudes; these influenced the potential choices of women at their first contact with their infant. Implications for practice: the focus of health care needs to extend beyond the institution. This means fewer normative actions performed by health professionals, enabling women to enjoy their early contact with their newborn infants. (C) 2010 Elsevier Ltd. All rights reserved.