492 resultados para POLYESTER-TONER


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this report, we describe the microfabrication and integration of planar electrodes for contactless conductivity detection on polyester-toner (PT) electrophoresis microchips using toner masks. Planar electrodes were fabricated by three simple steps: (i) drawing and laser-printing the electrode geometry on polyester films, (ii) sputtering deposition onto substrates, and (iii) removal of toner layer by a lift-off process. The polyester film with anchored electrodes was integrated to PT electrophoresis microchannels by lamination at 120 degrees C in less than 1 min. The electrodes were designed in an antiparallel configuration with 750 mu m width and 750 gm gap between them. The best results were recorded with a frequency of 400 kHz and 10 V-PP using a sinusoidal wave. The analytical performance of the proposed microchip was evaluated by electrophoretic separation of potassium, sodium and lithium in 150 mu m wide x 6 mu m deep microchannels. Under an electric field of 250 V/cm the analytes were successfully separated in less than 90 s with efficiencies ranging from 7000 to 13 000 plates. The detection limits (S/N = 3) found for K+, Na+, and Li+ were 3.1, 4.3, and 7.2 mu mol/L, respectively. Besides the low-cost and instrumental simplicity, the integrated PT chip eliminates the problem of manual alignment and gluing of the electrodes, permitting more robustness and better reproducibility, therefore, more suitable for mass production of electrophoresis microchips.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A variety of substrates have been used for fabrication of microchips for DNA extraction, PCR amplification, and DNA fragment separation, including the more conventional glass and silicon as well as alternative polymer-based materials. Polyester represents one such polymer, and the laser-printing of toner onto polyester films has been shown to be effective for generating polyester-toner (PeT) microfluidic devices with channel depths on the order of tens of micrometers. Here, we describe a novel and simple process that allows for the production of multilayer, high aspect-ratio PeT microdevices with substantially larger channel depths. This innovative process utilizes a CO(2) laser to create the microchannel in polyester sheets containing a uniform layer of printed toner, and multilayer devices can easily be constructed by sandwiching the channel layer between uncoated cover sheets of polyester containing precut access holes. The process allows the fabrication of deep channels, with similar to 270 mu m, and we demonstrate the effectiveness of multilayer PeT microchips for dynamic solid phase extraction (dSPE) and PCR amplification. With the former, we found that (i) more than 65% of DNA from 0.6 mu L of blood was recovered, (ii) the resultant DNA was concentrated to greater than 3 ng/mu L., (which was better than other chip-based extraction methods), and (iii) the DNA recovered was compatible with downstream microchip-based PCR amplification. Illustrative of the compatibility of PeT microchips with the PCR process, the successful amplification of a 520 bp fragment of lambda-phage DNA in a conventional thermocycler is shown. The ability to handle the diverse chemistries associated with DNA purification and extraction is a testimony to the potential utility of PeT microchips beyond separations and presents a promising new disposable platform for genetic analysis that is low cost and easy to fabricate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper compares the analytical performance of microchannels fabricated in PDMS, glass, and polyester-toner for electrophoretic separations. Glass and PDMS chips were fabricated using well-established photolithographic and replica-molding procedures, respectively. PDMS channels were sealed against three different types of materials: native PDMS, plasma-oxidized PDMS, and glass. Polyester-toner chips were micromachined by a direct-printing process using an office laser printer. All microchannels were fabricated with similar dimensions according to the limitations of the direct-printing process (width/depth 150 mu m/12 mu m). LIF was employed for detection to rule out any losses in separation efficiency due to the detector configuration. Two fluorescent dyes, coumarin and fluorescein, were used as model analytes. Devices were evaluated for the following parameters related to electrophoretic separations: EOF, heat dissipation, injection reproducibility, separation efficiency, and adsorption to channel wall.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microchip electrophoresis has become a powerful tool for DNA separation, offering all of the advantages typically associated with miniaturized techniques: high speed, high resolution, ease of automation, and great versatility for both routine and research applications. Various substrate materials have been used to produce microchips for DNA separations, including conventional (glass, silicon, and quartz) and alternative (polymers) platforms. In this study, we perform DNA separation in a simple and low-cost polyester-toner (PeT)-based electrophoresis microchip. PeT devices were fabricated by a direct-printing process using a 600 dpi-resolution laser printer. DNA separations were performed on PeT chip with channels filled with polymer solutions (0.5% m/v hydroxyethylcellulose or hydroxypropylcellulose) at electric fields ranging from 100 to 300Vcm(-1). Separation of DNA fragments between 100 and 1000 bp, with good correlation of the size of DNA fragments and mobility, was achieved in this system. Although the mobility increased with increasing electric field, separations showed the same profile regardless of the electric field. The system provided good separation efficiency (215 000 plates per m for the 500 bp fragment) and the separation was completed in 4 min for 1000 bp fragment ladder. The cost of a given chip is approximately $0.15 and it takes less than 10 minutes to prepare a single device.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Neste trabalho são apresentados processos de microfabricação de estruturas contendo microcanais e sistemas de manipulação hidrodinâmica e eletroosmótica de fluídos. Foram desenvolvidos processos de microfabricação utilizando toner sobre poliéster, toner sobre vidro, toner como resiste, além de métodos alternativos de perfuração de lâminas e selagem de microestruturas em vidro, desenvolvimento de microestruturas para eletroforese capilar e espectrometria de massas com ionização por eletronebulização. A caracterização dos materiais e processos permitiu uma ampla visão das potencialidades e alternativas dos processos de microfabricação, tendo sido demonstrado que os dispositivos produzidos em toner-poliéster são quimicamente resistentes às substâncias tipicamente utilizadas em eletroforese capilar. Neste trabalho, um detector condutométrico sem contato foi implementado em microestruturas de toner-poliéster e a separação eletroforética de alguns metais alcalinos é demonstrada. A microestrutura foi projetada no formato padrão em cruz, tendo o canal de separação 22 mm de comprimento, 12 µm de profundidade e largura típica. A cela condutométrica foi construída sobre o canal de separação utilizando-se fita adesiva de cobre (1 mm de largura) como eletrodos. O sinal aplicado na cela foi de 530 kHz e 10 Vpp . A separação de K+, Na+ e Li+ na concentração de 100 µmol L-1 foi efetuada em torno de 0,8 min, utilizando-se 1 kV como potencial de separação. Foram desenvolvidos microchips para análise por espectrometria de massas com introdução de amostra por eletronebulização, sendo determinado cluster do íon cloreto em concentração de 1 mmol L+. Também solução com 1 mmol/L de glucosamina em água/metanol 1: 1 (v/v), sob corrente de 100 nA gerou sinal estável e livre de descarga corona. Utilizando detecção amperométrica, obteve-se eletroferogramas mostrando a separação de iodeto (10 mmol L-1) e ascorbato (40 mmol L-1) em potencial de separação de 4,0 kV (800 V cm-1 potencial de detecção de 0,9 V (vs. Ag/AgCI), injeção com 1,0 kV/1°s, tampão borato de sódio 10 mmol L+ com CTAH 0,2 mmol L-1, pH 9,2. Obteve-se eficiência de 1,6.104 pratos/m e foi possível obter limites de detecção de 500 nmol L-1 (135 amol) e 1,8 µmol L-1 (486 amol) para iodeto e ascorbato, respectivamente. O processo de fabricação utilizando toner como material estrutural para microchips em vidro foi bem estabelecido, assim como os modos de detecção fotométrico e condutométrico foram demonstrados. Foram obtidos eletroferogramas par detecção condutométrica sem contato de solução 200 µmol L-1 de K+, Na+ e U+, em tampão histidina/ácido lático 30 mmol L-1 9:1 (v/v) água:metanol, injeção eletrocinética de 2,0 kV/5,0 s, potencial de separação de 1 kV, 530 kHz de frequência e tensão de 2,0 Vpp. Também foi implementado um sistema de detecção fotométrico para microchip operando em 660 nm, tendo sido utilizado para a detecção de azul de metileno 1,0 mmol L-1 em tampão de corrida de barato de sódio 20 mmol L-1 (pH 9,2), com o detector posicionado a 40 mm do ponto de injeção e com injeção eletrocinética a 2,0 kV por 12 s com picos bem resolvidos em menos de 1 min.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this report, we describe a rapid and reliable process to bond channels fabricated in glass substrates. Glass channels were fabricated by photolithography and wet chemical etching. The resulting channels were bonded against another glass plate containing a 50-mu m thick PDMS layer. This same PDMS layer was also used to provide the electrical insulation of planar electrodes to carry out capacitively coupled contactless conductivity detection. The analytical performance of the proposed device was shown by using both LIF and capacitively coupled contactless conductivity detection systems. Efficiency around 47 000 plates/m was achieved with good chip-to-chip repeatability and satisfactory long-term stability of EOF. The RSD for the EOF measured in three different devices was ca. 7%. For a chip-to-chip comparison, the RSD values for migration time, electrophoretic current and peak area were below 10%. With the proposed approach, a single chip can be fabricated in less than 30 min including patterning, etching and sealing steps. This fabrication process is faster and easier than the thermal bonding process. Besides, the proposed method does not require high temperatures and provides excellent day-to-day and device-to-device repeatability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, synthetic biodegradable polymers, such as aliphatic polyesters, are largely used in tissue engineering. They provide several advantages compared to natural materials which use is limited by immunocompatibility, graft availability, etc. In this work, poly(L-lactic) acid (PLLA), poly(DL-lactic) acid (PDLA), poly-epsilon-caprolactone (PCL), poly(L-lactic)-co-caprolactone (molar ratio 70/30) (PLCL) were selected because of their common use in tissue engineering. The membranes were elaborated by solvent casting. Membrane morphology was investigated by atomic force microscopy. The membranes were seeded with human fibroblasts from cell line CRL 2703 in order to evaluate the biocompatibility by the Alamar blue test. The roughness of the membranes ranged from 4 nm for PDLA to 120 nm and they presented very smooth surface except for PCL which beside a macroscopic structure due to its hydrophobicity. Human fibroblasts proliferated over 28 days on the membranes proving the non-in vitro toxicity of the materials and of the processing method. A further step will be the fabrication of three-dimensional scaffold for tissue engineering and the treatment of the scaffolds to augment cell adhesion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

THE addition of catalysts normally serves the purpose of imparting a desired burning rate change in a composite propellant. These may either retard or enhance the burning rate. Some often quoted catalysts are oxides, chromites and chromates of metals. A lot of work has been done on rinding the effect of the addition of some of these catalysts on the burning rate; however, none seems to have appeared on the influence of lithium fluoride (LiF). Only qualitative reduction in the burning rate of composite propellants with the addition of LiF was reported by Williams et al.1 Dickinson and Jackson2 reported a slight decrease in the specific impulse of composite propellant with the addition of LiF; however, they made no mention of the effect of its addition on the burning rate. We have studied the effect of the addition of varying amounts of LiF on the burning rate of Ammonium Perchlorate (AP)-Polyester propellant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract is not available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Castor oil-based poly(mannitol-citric sebacate) was synthesized by simple, catalyst-free melt condensation process using monomers having potential to be metabolized in vivo. The polymer was characterized using various techniques and the tensile and hydration properties of the polymers were also determined. The biocompatibility of the polymer was tested using human foreskin fibroblasts cells. The in vitro degradation studies show that the time for complete degradation of the polymer was more than 21 days. The usage of castor oil polyester as a drug carrier was analysed by doping the polymer with 5-fluorouracil model drug and the release rate was studied by varying the percentage loading of drugs and the pH of the PBS solution medium. The cumulative drug-release profiles exhibited a biphasic release with an initial burst release and cumulative 100% release within 42 h. To understand the role of the polymer as a drug carrier in the release behaviour, drug-release studies were conducted with another drug, isoniazid. The release behaviour of isoniazid drug from the same polymer matrix followed an nth order kinetic model and 100% cumulative release was achieved after 12 days. The variation in the release behaviour for two model drugs from the same polymer matrix suggests a strong interaction between the polymer and the drug molecule.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Self-condensation of AB(2) type monomers (containing one A-type and two B-type functional groups) generates hyperbranched (HB) polymers that carry numerous B-type end-groups at their molecular periphery; thus, development of synthetic methods that directly provide quantitatively transformable peripheral B groups would be of immense value as this would provide easy access to multiply functionalized HB systems. A readily accessible AB(2) monomer, namely diallyl, 5-(4-hydroxybutoxy)isophthalate was synthesized, which on polymerization under standard melt-transesterfication conditions yielded a peripherally clickable HB polyester in a single step; the allyl groups were quantitatively reacted with a variety of thiols using the facile photoinitiated thiol-ene reaction to generate a wide range of derivatives, with varying solubility and thermal properties. Furthermore, it is shown that the peripheral allyl double bonds can also be readily epoxidized using meta-chloroperoxybenzoic acid to yield interesting HB systems, which could potentially serve as a multifunctional cross-linking agent in epoxy formulations. (c) 2013 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2014, 131, 40248.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite advances in regenerative medicine, the cost of such therapies is beyond the reach of many patients globally in part due to the use of expensive biomedical polymers. Large volumes of poly(ethylene terephthalate) (PET) in municipal waste is a potential source of low cost polymers. A novel polyester was prepared by a catalyst-free, melt polycondensation reaction of bis(hydroxyethylene) terephthalate derived from PET post-consumer waste with other multi-functional monomers from renewable sources such as citric acid, sebacic acid and D-mannitol. The mechanical properties and degradation rate of the polyester can be tuned by varying the composition and the post-polymerization time. The polyester was found to be elastomeric, showed excellent cytocompatibility in vitro and elicited minimal immune response in vivo. Three-dimensional porous scaffolds facilitated osteogenic differentiation and mineralization. This class of polyester derived from low cost, recycled waste and renewable sources is a promising candidate for use in regenerative medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There has been a continuous surge toward developing new biopolymers that exhibit better in vivo biocompatibility properties in terms of demonstrating a reduced foreign body response (FBR). One approach to mitigate the undesired FBR is to develop an implant capable of releasing anti-inflammatory molecules in a sustained manner over a long time period. Implants causing inflammation are also more susceptible to infection. In this article, the in vivo biocompatibility of a novel, biodegradable salicylic acid releasing polyester (SAP) has been investigated by subcutaneous implantation in a mouse model. The tissue response to SAP was compared with that of a widely used biodegradable polymer, poly(lactic acid-co-glycolic acid) (PLGA), as a control over three time points: 2, 4, and 16 weeks postimplantation. A long-term in vitro study illustrates a continuous, linear (zero order) release of salicylic acid with a cumulative mass percent release rate of 7.34 x 10(-4) h(-1) over similar to 1.5-17 months. On the basis of physicochemical analysis, surface erosion for SAP and bulk erosion for PLGA have been confirmed as their dominant degradation modes in vivo. On the basis of the histomorphometrical analysis of inflammatory cell densities and collagen distribution as well as quantification of proinflammatory cytokine levels (TNF-alpha and IL-1 beta), a reduced foreign body response toward SAP with respect to that generated by PLGA has been unambiguously established. The favorable in vivo tissue response to SAP, as manifest from the uniform and well-vascularized encapsulation around the implant, is consistent with the decrease in inflammatory cell density and increase in angiogenesis with time. The above observations, together with the demonstration of long-term and sustained release of salicylic acid, establish the potential use of SAP for applications in improved matrices for tissue engineering and chronic wound healing.