744 resultados para PLEXUS-PALSY
Resumo:
BACKGROUND: Nerve transfers or graft repairs in upper brachial plexus palsies are 2 available options for elbow flexion recovery. OBJECTIVE: To assess outcomes of biceps muscle strength when treated either by grafts or nerve transfer. METHODS: A standard supraclavicular approach was performed in all patients. When roots were available, grafts were used directed to proximal targets. Otherwise, a distal ulnar nerve fascicle was transferred to the biceps branch. Elbow flexion strength was measured with a dynamometer, and an index comparing the healthy arm and the operated-on side was developed. Statistical analysis to compare both techniques was performed. RESULTS: Thirty-five patients (34 men) were included in this series. Mean age was 28.7 years (standard deviation, 8.7). Twenty-two patients (62.8%) presented with a C5-C6 injury, whereas 13 patients (37.2%) had a C5-C6-C7 lesion. Seventeen patients received reconstruction with grafts, and 18 patients were treated with a nerve transfer from the ulnar nerve to the biceps. The trauma to surgery interval (mean, 7.6 months in both groups), strength in the healthy arm, and follow-up duration were not statistically different. On the British Medical Research Council muscle strength scale, 8 of 17 (47%) patients with a graft achieved >= M3 biceps flexion postoperatively, vs 16 of 18 (88%) post nerve transfers (P = .024). This difference persisted when a muscle strength index assessing improvement relative to the healthy limb was used (P = .031). CONCLUSION: The results obtained from ulnar nerve fascicle transfer to the biceps branch were superior to those achieved through reconstruction with grafts.
Resumo:
Objective: To evaluate the prognostic value of absent thumb pain sensation in newborns and young infants with birth brachial plexopathy. Methods: We evaluated 131 patients with birth brachial plexopathy with less than two months of age. Pain sensation was evoked by thumb nail bed compression to evaluate sensory fibers of the upper trunk (C6). The patients were followed-up monthly. Patients with less than antigravity elbow flexion at six months of age were considered to have a poor outcome. Results: Thirty patients had absent thumb pain sensation, from which 26 showed a poor outcome. Sensitivity of the test was 65% and specificity was 96%. Conclusion: Evaluation of thumb pain sensation should be included in the clinical assessment of infants with birth brachial plexopathy.
Resumo:
Background: Brachial plexus birth palsy (BPBP) most often occurs as a result of foetal-maternal disproportion. The C5 and C6 nerve roots of the brachial plexus are most frequently affected. In contrast, roots from the C7 to Th1 that result in total injury together with C5 and C6 injury, are affected in fewer than half of the patients. BPBP was first described by Smellie in 1764. Erb published his classical description of the injury in 1874 and his name became linked with the paralysis that is associated with upper root injury. Since then, early results of brachial plexus surgery have been reasonably well documented. However, from a clinical point of view not all primary results are maintained and there is also a need for later follow-up results. In addition most of the studies that are published emanate from highly specialized clinics and no nation wide epidemiological reports are available. One of the plexus injuries is the avulsion type, in which the nerve root or roots are ruptured at the neural cord. It has been speculated whether this might cause injury to the whole neural system or whether shoulder asymmetry and upper limb inequality results in postural deformities of the spine. Alternatively, avulsion could manifest as other signs and symptoms of the whole musculoskeletal system. In addition, there is no available information covering activities of daily living after obstetric brachial plexus surgery. Patients and methods: This was a population-based cross-sectional study on all patients who had undergone brachial plexus surgery with at least 5 years of follow-up. An incidence of 3.05/1000 for BPBP was obtained from the registers for this study period. A total of 1706 BPBP patients needing hospital treatment out of 1 717 057 newborns were registered in Finland between 1971 and 1997 inclusive. Of these BPBP patients, 124 (7.3%) underwent brachial plexus surgery at a mean age of 2.8 months (range: 0.4―13.2 months). Surgery was most often performed by direct neuroraphy after neuroma resection (53%). Depending on the phase of the study, 105 to 112 patients (85-90%) participated in a clinical and radiological follow-up assessment. The mean follow up time exceeded 13 years (range: 5.0―31.5 years). Functional status of the upper extremity was evaluated using Mallet, Gilbert and Raimondi scales. Isometric strength of the upper limb, sensation of the hand and stereognosis were evaluated for both the affected and unaffected sides then the differences and their ratios were calculated and recorded. In addition to the upper extremity, assessment of the spine and lower extremities were performed. Activities of daily living (ADL), participation in normal physical activities, and the use of physiotherapy and occupational therapy were recorded in a questionnaire. Results: The unaffected limb functioned as the dominant hand in all, except four patients. The mean length of the affected upper limb was 6 cm (range: 1-13.5 cm) shorter in 106 (95%) patients. Shoulder function was recorded as a mean Mallet score of 3 (range: 2―4) which was moderate. Both elbow function and hand function were good. The mean Gilbert elbow scale value was 3 (range: -1―5) and the mean Raimondi hand scale was 4 (range:1―5). One-third of the patients experienced pain in the affected limb including all those patients (n=9) who had clavicular non-union resulting from surgery. A total of 61 patients (57%) had an active shoulder external rotation of less than 0° and an active elbow extension deficiency was noted in 82 patients (77%) giving a mean of 26° (range: 5°―80°). In all, expect two patients, shoulder external rotation strength at a mean ratio 35% (range: 0―83%) and in all patients elbow flexion strength at a mean ratio of 41% (range: 0―79%) were impaired compared to the unaffected side. According to radiographs, incongruence of the glenohumeral joint was noted in 15 (16%) patients, whereas incongruence of the radiohumeral joint was found in 20 (21%) patients. Fine sensation was normal for 34/49 (69%) patients with C5-6 injury, for 15/31 (48%) with C5-7 and for only 8/25 (32%) of patients with total injury. Loss of protective sensation or absent sensation was noted in some palmar areas of the hand for 12/105 patients (11%). Normal stereognosis was recorded for 88/105 patients (84%). No significant inequalities in leg length were found and the incidence of structural scoliosis (1.7%) did not differ from that of the reference population. Nearly half of the patients (43%) had asynchronous motion of the upper limbs during gait, which was associated with impaired upper limb function. Data obtained from the completed questionnaires indicated that two thirds (63%) of the patients were satisfied with the functional outcome of the affected hand although one third of all patients needed help with ADL. Only a few patients were unable to participate in physical activities such as: bicycling, cross-country skiing or swimming. However, 71% of the patients reported problems related to the affected upper limb, such as muscle weakness and/or joint stiffness during the aforementioned activities. Incongruity of the radiohumeral joints, extent of the injury, avulsion type injury, age less than three months of age at the time of plexus surgery and inexperience of the surgeon was related to poor results as determined by multivariate analyses. Conclusions: Most of the patients had persistent sequelae, especially of shoulder function. Almost all measurements for the total injury group were poorer compared with those of the C5-6 type injury group. Most of the patients had asymmetry of the shoulder region and a shorter affected upper limb, which is a probable reason for having an abnormal gait. However, BPBP did not have an effect on normal growth of the lower extremities or the spine. Although, participation in physical activities was similar to that of the normal population, two-thirds of the patients reported problems. One-third of the patients needed help with ADL. During the period covered by this study, 7.3% BPBP of patients that needed hospital treatment had a brachial plexus operation, which amounts to fewer than 10 operations per year in Finland. It seems that better results of obstetric plexus surgery and more careful follow-up including opportunities for late reconstructive procedures will be expected, if the treatment is solely concentrated on by a few specialised teams.
Resumo:
Objective: To evaluate the factors influencing the results of ulnar nerve neurotization at the motor branch of the brachii biceps muscle, aiming at the restoration of elbow flexion in patients with brachial plexus injury. Methods: 19 patients, with 18 men and 1 woman, mean age 28.7 years. Eight patients had injury to roots C5-C6 and 11, to roots C5-C6-C7. The average time interval between injury and surgery was 7.5 months. Four patients had cervical fractures associated with brachial plexus injury. The postoperative follow-up was 15.7 months. Results: Eight patients recovered elbow flexion strength MRC grade 4; two, MRC grade 3 and nine, MRC <3. There was no impairment of the previous ulnar nerve function. Conclusion: The surgical results of ulnar nerve neurotization at the motor branch of brachii biceps muscle are dependent on the interval between brachial plexus injury and surgical treatment, the presence of associated fractures of the cervical spine and occipital condyle, residual function of the C8-T1 roots after the injury and the involvement of the C7 root. Signs of reinnervation manifested up to 3 months after surgery showed better results in the long term. Level of Evidence: IV, Case Series.
Resumo:
Abstract Background The etiology of Bell's palsy can vary but anterograde axonal degeneration may delay spontaneous functional recovery leading the necessity of therapeutic interventions. Corticotherapy and/or complementary rehabilitation interventions have been employed. Thus the natural history of the disease reports to a neurotrophic resistance of adult facial motoneurons leading a favorable evolution however the related molecular mechanisms that might be therapeutically addressed in the resistant cases are not known. Fibroblast growth factor-2 (FGF-2) pathway signaling is a potential candidate for therapeutic development because its role on wound repair and autocrine/paracrine trophic mechanisms in the lesioned nervous system. Methods Adult rats received unilateral facial nerve crush, transection with amputation of nerve branches, or sham operation. Other group of unlesioned rats received a daily functional electrical stimulation in the levator labii superioris muscle (1 mA, 30 Hz, square wave) or systemic corticosterone (10 mgkg-1). Animals were sacrificed seven days later. Results Crush and transection lesions promoted no changes in the number of neurons but increased the neurofilament in the neuronal neuropil of axotomized facial nuclei. Axotomy also elevated the number of GFAP astrocytes (143% after crush; 277% after transection) and nuclear FGF-2 (57% after transection) in astrocytes (confirmed by two-color immunoperoxidase) in the ipsilateral facial nucleus. Image analysis reveled that a seven days functional electrical stimulation or corticosterone led to elevations of FGF-2 in the cytoplasm of neurons and in the nucleus of reactive astrocytes, respectively, without astrocytic reaction. Conclusion FGF-2 may exert paracrine/autocrine trophic actions in the facial nucleus and may be relevant as a therapeutic target to Bell's palsy.
Resumo:
Purpose: To determine the subbasal nerve density and tortuosity at 5 corneal locations and to investigate whether these microstructural observations correlate with corneal sensitivity. Method: Sixty eyes of 60 normal human subjects were recruited into 1 of 3 age groups, group 1: aged ,35 years, group 2: aged 35–50 years, and group 3: aged .50 years. All eyes were examined using slit-lamp biomicroscopy, noncontact corneal esthesiometry, and slit scanning in vivo confocal microscopy. Results: The mean subbasal nerve density and the mean corneal sensitivity were greatest centrally (14,731 6 6056 mm/mm2 and 0.38 6 0.21 millibars, respectively) and lowest in the nasal mid periphery (7850 6 4947 mm/mm2 and 0.49 6 0.25 millibars, respectively). The mean subbasal nerve tortuosity coefficient was greatest in the temporal mid periphery (27.3 6 6.4) and lowest in the superior mid periphery (19.3 6 14.1). There was no significant difference in mean total subbasal nerve density between age groups. However, corneal sensation (P = 0.001) and subbasal nerve tortuosity (P = 0.004) demonstrated significant differences between age groups. Subbasal nerve density only showed significant correlations with corneal sensitivity threshold in the temporal cornea and with subbasal nerve tortuosity in the inferior and nasal cornea. However, these correlations were weak. Conclusions: This study quantitatively analyzes living human corneal nerve structure and an aspect of nerve function. There is no strong correlation between subbasal nerve density and corneal sensation. This study provides useful baseline data for the normal living human cornea at central and mid-peripheral locations
Resumo:
To develop a rapid optimized technique of wide-field imaging of the human corneal subbasal nerve plexus. A dynamic fixation target was developed and, coupled with semiautomated tiling software, a rapid method of capturing and montaging multiple corneal confocal microscopy images was created. To illustrate the utility of this technique, wide-field maps of the subbasal nerve plexus were produced in 2 participants with diabetes, 1 with and 1 without neuropathy. The technique produced montages of the central 3 mm of the subbasal corneal nerve plexus. The maps seem to show a general reduction in the number of nerve fibers and branches in the diabetic participant with neuropathy compared with the individual without neuropathy. This novel technique will allow more routine and widespread use of subbasal nerve plexus mapping in clinical and research situations. The significant reduction in the time to image the corneal subbasal nerve plexus should expedite studies of larger groups of diabetic patients and those with other conditions affecting nerve fibers. The inferior whorl and the surrounding areas may show the greatest loss of nerve fibers in individuals with diabetic neuropathy, but this should be further investigated in a larger cohort.
Resumo:
To evaluate the validity of the ActiGraph accelerometer for the measurement of physical activity intensity in children and adolescents with cerebral palsy (CP) using oxygen uptake (VO 2) as the criterion measure. Thirty children and adolescents with CP (mean age 12.6 ± 2.0 years) wore an ActiGraph 7164 and a Cosmed K4b 2 portable indirect calorimeter during four activities; quiet sitting, comfortable paced walking, brisk paced walking and fast paced walking. VO 2 was converted to METs and activity energy expenditure and classiWed as sedentary, light or moderate-to-vigorous intensity according to the conventions for children. Mean ActiGraph counts min -1 were classiWed as sedentary, light or moderate-to-vigorous (MVPA) intensity using four diVerent sets of cut-points. VO 2 and counts min¡1 increased signiWcantly with increases in walking speed (P < 0.001). Receiver operating characteristic (ROC) curve analysis indicated that, of the four sets of cut-points evaluated, the Evenson et al. (J Sports Sci 26(14):1557-1565, 2008) cut-points had the highest classiWcation accuracy for sedentary (92%) and MVPA (91%), as well as the second highest classiWcation accuracy for light intensity physical activity (67%). A ROC curve analysis of data from our participants yielded a CP-speciWc cut-point for MVPA that was lower than the Evenson cut-point (2,012 vs. 2,296 counts min¡1), however, the diVerence in classiWcation accuracy was not statistically signiWcant 94% (95% CI = 88.2-97.7%) vs. 91% (95% CI = 83.5-96.5%). In conclusion, among children and adolescents with CP, the ActiGraph is able to diVerentiate between diVerent intensities of walking. The use of the Evenson cut-points will permit the estimation of time spent in MVPA and allows comparisons to be made between activity measured in typically developing adolescents and adolescents with CP. © 2011 Springer-Verlag.
Resumo:
Background Promoting participation physical activity (PA) is an important means of promoting healthy growth and development in children with cerebral palsy (CP). The ActiGraph is a uniaxial accelerometer that provides a realtime measure of PA intensity, duration and frequency. Its small, light weight design makes it a promising measure of activity in children with CP. To date no study has validated the use of accelerometry as a measure of PA in ambulant adolescents with CP. Objectives To evaluate the validity of the ActiGraph accelerometer for measuring PA intensity in adolescents with CP, using oxygen consumption (VO2), measured using portable indirect calorimetry (Cosmed K4b2), as the criterion measure. Design Validation Study Participants/Setting: Ambulant adolescents with CP aged 10–16 years, GMFCS rating of I-III. The recruitment target is 30 (10 in each GMFCS level). Materials/Methods Participants wore the ActiGraph (counts/min) and a Cosmed K4b2 indirect calorimeter (mL/kg/min) during six activity trials: quiet sitting (QS), comfortable paced walking (CPW), brisk paced walking (BPW), fast paced walking (FPW), a ball-kicking protocol (KP) and a ball-throwing protocol (TP). MET levels (multiples of resting metabolism) for each activity were predicted from ActiGraph counts using the Freedson age-specific equation (Freedson et al. 2005) and compared with actual MET levels measured by the Cosmed. Predicted and measured METs for each activity trial were classified as light (> 1.5 METs and <4.6 METs) or moderate to vigorous intensity (≥ 4.6 METs). Results To date 36 bouts of activity have been completed (6 participants x 6 activities). Mean VO2 increased linearly as the intensity of the walking activity increased (CPW=9.47±2.16, BPW=14.06±4.38, FPW=19.21±5.68 ml/kg/min) and ActiGraph counts reflected this pattern (CPW=1099±574, BPW=2233±797 FPW=4707±1013 counts/min). The throwing protocol recording the lowest VO2 (TP=7.50±3.86 ml/kg/min) and lowest overall counts/min (TP=31±27 counts/min). When each of the 36 bouts were classified as either light or moderate to vigorous intensity using measured VO2 as the criterion measure, the Freedson equation correctly classified 28 from 36 bouts (78%). Conclusion/Clinical Implications These preliminary findings suggest that there is a relationship between the intensity of PA and direct measure of oxygen consumption and that therefore the ActiGraph may be a promising tool for accurately measuring free living PA in the community. Further data collection of the complete sample will enable secondary analysis of the relationship between PA and severity of CP (GMFCS level).
Resumo:
Purpose We examined the age-dependent alterations and longitudinal course of subbasal nerve plexus (SNP) morphology in healthy individuals. Methods Laser-scanning corneal confocal microscopy, ocular screening, and health and metabolic assessment were performed on 64 healthy participants at baseline and at 12-month intervals for 3 years. At each annual visit, eight central corneal images of the SNP were selected and analyzed using a fully-automated analysis system to quantify corneal nerve fiber length (CNFL). Two linear mixed model approaches were fitted to examine the relationship between age and CNFL, and the longitudinal changes of CNFL over three years. Results At baseline, mean age was 51.9 ± 14.7 years. The cohort was sex balanced (χ2 = 0.56, P = 0.45). Age (t = 1.6, P = 0.12) and CNFL (t = -0.50, P = 0.62) did not differ between sexes. A total of 52 participants completed the 36-month visit and 49 participants completed all visits. Age had a significant effect on CNFL (F1,33 = 5.67, P = 0.02) with a linear decrease of 0.05 mm/mm2 in CNFL per one year increase in age. No significant change in CNFL was observed over the 36-month period (F1,55 = 0.69, P = 0.41). Conclusions The CNFL showed a stable course over a 36-month period in healthy individuals, although there was a slight linear reduction in CNFL with age. The findings of this study have implications for understanding the time-course of the effect of pathology and surgical or therapeutic interventions on the morphology of the SNP, and serves to confirm the suitability of CNFL as a screening/monitoring marker for peripheral neuropathies.
Resumo:
PURPOSE
The purposes of this study were to:
1) establish inter-instrument reliability between left and right hip accelerometer placement;
2) examine procedural reliability of a walking protocol used to measure physical activity (PA), and;
3) confirm concurrent validity of accelerometers in measuring PA intensity as compared to the gold standard of oxygen consumption measured by indirect calorimetry.
METHODS
Eight children (mean age: 11.9; SD: 3.2, 75% male) with CP (GMFCS levels I-III) wore ActiGraph GT3X accelerometers on each hip and the Cosmed K4b
Resumo:
Purpose The aim of the study was to determine the association, agreement, and detection capability of manual, semiautomated, and fully automated methods of corneal nerve fiber length (CNFL) quantification of the human corneal subbasal nerve plexus (SNP). Methods Thirty-three participants with diabetes and 17 healthy controls underwent laser scanning corneal confocal microscopy. Eight central images of the SNP were selected for each participant and analyzed using manual (CCMetrics), semiautomated (NeuronJ), and fully automated (ACCMetrics) software to quantify the CNFL. Results For the entire cohort, mean CNFL values quantified by CCMetrics, NeuronJ, and ACCMetrics were 17.4 ± 4.3 mm/mm2, 16.0 ± 3.9 mm/mm2, and 16.5 ± 3.6 mm/mm2, respectively (P < 0.01). CNFL quantified using CCMetrics was significantly higher than those obtained by NeuronJ and ACCMetrics (P < 0.05). The 3 methods were highly correlated (correlation coefficients 0.87–0.98, P < 0.01). The intraclass correlation coefficients were 0.87 for ACCMetrics versus NeuronJ and 0.86 for ACCMetrics versus CCMetrics. Bland–Altman plots showed good agreement between the manual, semiautomated, and fully automated analyses of CNFL. A small underestimation of CNFL was observed using ACCMetrics with increasing the amount of nerve tissue. All 3 methods were able to detect CNFL depletion in diabetic participants (P < 0.05) and in those with peripheral neuropathy as defined by the Toronto criteria, compared with healthy controls (P < 0.05). Conclusions Automated quantification of CNFL provides comparable neuropathy detection ability to manual and semiautomated methods. Because of its speed, objectivity, and consistency, fully automated analysis of CNFL might be advantageous in studies of diabetic neuropathy.
Resumo:
PURPOSE To develop and test decision tree (DT) models to classify physical activity (PA) intensity from accelerometer output and Gross Motor Function Classification System (GMFCS) classification level in ambulatory youth with cerebral palsy (CP); and 2) compare the classification accuracy of the new DT models to that achieved by previously published cut-points for youth with CP. METHODS Youth with CP (GMFCS Levels I - III) (N=51) completed seven activity trials with increasing PA intensity while wearing a portable metabolic system and ActiGraph GT3X accelerometers. DT models were used to identify vertical axis (VA) and vector magnitude (VM) count thresholds corresponding to sedentary (SED) (<1.5 METs), light PA (LPA) (>/=1.5 and <3 METs) and moderate-to-vigorous PA (MVPA) (>/=3 METs). Models were trained and cross-validated using the 'rpart' and 'caret' packages within R. RESULTS For the VA (VA_DT) and VM decision trees (VM_DT), a single threshold differentiated LPA from SED, while the threshold for differentiating MVPA from LPA decreased as the level of impairment increased. The average cross-validation accuracy for the VC_DT was 81.1%, 76.7%, and 82.9% for GMFCS levels I, II, and III, respectively. The corresponding cross-validation accuracy for the VM_DT was 80.5%, 75.6%, and 84.2%, respectively. Within each GMFCS level, the decision tree models achieved better PA intensity recognition than previously published cut-points. The accuracy differential was greatest among GMFCS level III participants, in whom the previously published cut-points misclassified 40% of the MVPA activity trials. CONCLUSION GMFCS-specific cut-points provide more accurate assessments of MVPA levels in youth with CP across the full spectrum of ambulatory ability.
Resumo:
BACKGROUND Physical therapy for youth with cerebral palsy (CP) who are ambulatory includes interventions to increase functional mobility and participation in physical activity (PA). Thus, reliable and valid measures are needed to document PA in youth with CP. OBJECTIVE The purpose of this study was to evaluate the inter-instrument reliability and concurrent validity of 3 accelerometer-based motion sensors with indirect calorimetry as the criterion for measuring PA intensity in youth with CP. METHODS Fifty-seven youth with CP (mean age=12.5 years, SD=3.3; 51% female; 49.1% with spastic hemiplegia) participated. Inclusion criteria were: aged 6 to 20 years, ambulatory, Gross Motor Function Classification System (GMFCS) levels I through III, able to follow directions, and able to complete the full PA protocol. Protocol activities included standardized activity trials with increasing PA intensity (resting, writing, household chores, active video games, and walking at 3 self-selected speeds), as measured by weight-relative oxygen uptake (in mL/kg/min). During each trial, participants wore bilateral accelerometers on the upper arms, waist/hip, and ankle and a portable indirect calorimeter. Intraclass coefficient correlations (ICCs) were calculated to evaluate inter-instrument reliability (left-to-right accelerometer placement). Spearman correlations were used to examine concurrent validity between accelerometer output (activity and step counts) and indirect calorimetry. Friedman analyses of variance with post hoc pair-wise analyses were conducted to examine the validity of accelerometers to discriminate PA intensity across activity trials. RESULTS All accelerometers exhibited excellent inter-instrument reliability (ICC=.94-.99) and good concurrent validity (rho=.70-.85). All accelerometers discriminated PA intensity across most activity trials. LIMITATIONS This PA protocol consisted of controlled activity trials. CONCLUSIONS Accelerometers provide valid and reliable measures of PA intensity among youth with CP.