121 resultados para PLETHYSMOGRAPHY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate whether venous occlusion plethysmography (VOP) may be used to measure high rates of arterial inflow associated with exercise, venous occlusions were performed at rest, and following dynamic handgrip exercise at 15, 30, 45, and 60 % of maximum voluntary contraction (MVC) in seven healthy males. The effect of including more than one cardiac cycle in the calculation of blood flow was assessed by comparing the cumulative blood flow over one, two, three, or four cardiac cycles. The inclusion of more than one cardiac cycle at 30 and 60 % MVC, and more than two cardiac cycles at 15 and 45 % MVC resulted in a lower blood flow compared to using only the first cardiac cycle (P < 0.05). Despite the small time interval over which arterial inflow was measured (~1 second), this did not affect the reproducibility of the technique. Reproducibility (coefficient of variation for arterial inflow over three trials) tended to be poorer at the higher workloads, although this was not significant (12.7 ± 6.6 %, 16.2 ± 7.3 %, and 22.9 ± 9.9 % for the 15, 30, and 45 % MVC workloads; P=0.102). There was also a tendency for greater reproducibility with the inclusion of more cardiac cycles at the highest workload, but this did not reach significance (P=0.070). In conclusion, when calculated over the first cardiac cycle only during venous occlusion, high rates of FBF can be measured using VOP, and this can be achieved without a significant decrease in the reproducibility of the measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’atteinte de la fonction endothéliale représente une phase précoce de l’athérosclérose, un stade où les patients sont généralement asymptomatiques. Il existe donc un intérêt certain à détecter la dysfonction endothéliale. Nous avons développé une technique de mesure des variations de flot artériel au niveau des membres supérieurs, basée sur la spectroscopie proche infrarouge (NIRS). Cette approche permettrait d’étudier le niveau d’atteinte vasculaire et probablement de quantifier le degré de dysfonction endothéliale périphérique lors d’une hyperémie réactive. L'expérience a été exécutée sur deux cohortes de 13 et de 15 patients et a été comparée à la pléthysmographie par jauge de contrainte (SGP) qui est considérée comme une méthode de référence. Par la suite, nous avons caractérisé la réponse endothéliale par modélisation de la courbe hyperémique du flot artériel. Des études préliminaires avaient démontré que la réponse hyperémique adoptait majoritairement une forme bi-modale. Nous avons tenté de séparer les composantes endothéliales-dépendantes et endothéliales-indépendantes de l’hyperémie. La quantification des deux composantes de la réaction hyperémique permet de calculer un indice de la ‘santé’ du système endothélial local. Cet indice est nommé le ηfactor. Les résultats montrent une forte corrélation des mesures de flots entre la technique développée et la méthode de référence (r=0.91). Nous avons conclu que NIRS est une approche précise pour la mesure non-invasive du flot artériel. Nous avons obtenu une bonne répétabilité (ICC = 0.9313) pour le ηfactor indiquant sa robustesse. Cependant des études supplémentaires sont nécessaires pour valider la valeur de diagnostic du facteur défini. Mots clés: hyperémie réactive, réponse myogénique, oxyde nitrique, athérosclérose, spectroscopie proche infrarouge

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare two methods of respiratory inductive plethysmography (RIP) calibration in three different positions. Methods: We evaluated 28 healthy subjects (18 women and 10 men), with a mean age of 25.4 +/- 3.9 years. For all of the subjects, isovolume maneuver calibration (ISOCAL) and qualitative diagnostic calibration (QDC) were used in the orthostatic, sitting, and supine positions. In order to evaluate the concordance between the two calibration methods, we used ANOVA and Bland-Altman plots. Results: The values of the constant of proportionality (X) were significantly different between ISOCAL and QDC in the three positions evaluated: 1.6 +/- 0.5 vs. 2.0 +/- 1.2, in the supine position, 2.5 +/- 0.8 vs. 0.6 +/- 0.3 in the sitting position, and 2.0 +/- 0.8 vs. 0.6 +/- 0.3 in the orthostatic position (p < 0.05 for all). Conclusions: Our results suggest that QDC is an inaccurate method for the calibration of RIP. The K values obtained with ISOCAL reveal that RIP should be calibrated for each position evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Hypnotic depth but not haemodynamic response to painful stimulation can be measured with various EEG-based anaesthesia monitors. We evaluated the variation of pulse plethysmography amplitude induced by an electrical tetanic stimulus (PPG variation) as a potential measure for analgesia and predictor of haemodynamic responsiveness during general anaesthesia. METHODS: Ninety-five patients, ASA I or II, were randomly assigned to five groups [Group 1: bispectral index (BIS) (range) 40-50, effect site remifentanil concentration 1 ng ml(-1);Group 2: BIS 40-50, remifentanil 2 ng ml(-1); Group 3: BIS 40-50, remifentanil 4 ng ml(-1); Group 4: BIS 25-35, remifentanil 2 ng ml(-1); Group 5: BIS 55-65, remifentanil 2 ng ml(-1)]. A 60 mA tetanic stimulus was applied for 5 s on the ulnar nerve. From the digitized pulse oximeter wave recorded on a laptop computer, linear and non-linear parameters of PPG variation during the 60 s period after stimulation were computed. The haemodynamic response to subsequent orotracheal intubation was recorded. The PPG variation was compared between groups and between responders and non-responders to intubation (anova). Variables independently predicting the response were determined by logistic regression. RESULTS: The probability of a response to tracheal intubation was 0.77, 0.47, 0.05, 0.18 and 0.52 in Groups 1-5, respectively (P<0.03). The PPG variability was significantly higher in responders than in non-responders but it did not improve the prediction of the response to tracheal intubation based on BIS level and effect site remifentanil concentration. CONCLUSION: Tetanic stimulation induced PPG variation does not reflect the analgesic state in a wide clinical range of surgical anaesthesia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to assess the validity of barometric whole-body plethysmography (BWBP), to establish reference values, and to standardise a bronchoprovocative test to investigate airway responsiveness using BWBP in healthy dogs. BWBP measurements were obtained from six healthy beagle dogs using different protocols: (1) during three consecutive periods (3.5min each) in two morning and two evening sessions; (2) before and after administration of two protocols of sedation; (3) before and after nebulisation of saline and increasing concentrations of carbachol and histamine both in conscious dogs and in dogs under both protocols of sedation. Enhanced pause (PENH) was used as index of bronchoconstriction. Basal BWBP measurements were also obtained in 22 healthy dogs of different breeds, age and weight. No significant influence of either time spent in the chamber or daytime was found for most respiratory variables but a significant dog effect was detected for most variables. A significant body weight effect was found on tidal volume and peak flow values (P<0.05). Response to carbachol was not reproducible and always associated with side effects. Nebulisation of histamine induced a significant increase in respiratory rate, peak expiratory flow, peak expiratory flow/peak inspiratory flow ratio and PENH (P<0.05). The response was reproduced in each dog at different concentrations of histamine. Sedation with acepromazine+buprenorphine had little influence on basal measurements and did not change the results of histamine challenge. It was concluded that BWBP is a safe, non invasive and reliable technique of investigation of lung function in dogs which provides new opportunities to characterise respiratory status, to evaluate airway hyperresponsiveness and to assess therapeutic interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of in-line curvature sensors on a garment are used to monitor the thoracic and abdominal movements of a human during respiration. These results are used to obtain volumetric tidal changes of the human torso in agreement with a spirometer used simultaneously at the mouth. The curvature sensors are based on long-period gratings (LPGs) written in a progressive three-layered fiber to render the LPGs insensitive to the refractive index external to the fiber. A curvature sensor consists of the fiber long-period grating laid on a carbon fiber ribbon, which is then encapsulated in a low-temperature curing silicone rubber. The sensors have a spectral sensitivity to curvature, d lambda/dR from similar to 7-nm m to similar to 9-nm m. The interrogation technique is borrowed from derivative spectroscopy and monitors the changes in the transmission spectral profile of the LPG's attenuation band due to curvature. The multiplexing of the sensors is achieved by spectrally matching a series of distributed feedback (DFB) lasers to the LPGs. The versatility of this sensing garment is confirmed by it being used on six other human subjects covering a wide range of body mass indices. Just six fully functional sensors are required to obtain a volumetric error of around 6%. (C) 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Preliminary results are given for a long period grating sensing array scheme based upon a derivative spectroscopy interrogation technique for Human Respiratory Plethysmography with simultaneous measurements of a spirometer, reasonable agreement with recorded volumetric changes was found.